HomeMy WebLinkAboutGN010.0 - ENERGY CERTIFICATEIndiana 2�2� Perfarman�e �ompliance Praperty 4359 PRAIRIE FALCQN dR ZI�NSVILLE, IN 4fi077 Madel: HERON Community: WATERFR�NT AT UVE� WWC053 {AS DE5IGNED} WATERFRONTAT UVEST CLAY 53 11D5 11 D2.4.12 11 D2.5 11 D2.5 11 D4.1 PAandatory Checklist 11 D3.6 11 D3.6.1 ❑rganixatian TSI Energy Solutions Matthew Timmons 6uilder PALJL SHDDPMAN H�ME 6LJILaING GRDUP Annual Energy Cost Design Heating Cooling Water Heating Mechanical Ventilatian SubTotal - Used to determine GomplianGe Lights & Appliances wlout Ventilation �nsite generation Total Indiana 2020 Performance $1,483 $2�8 $197 $�0 $1,989 $889 $fl $2,878 Requirements � � � � � � � � Performance-based compliance passes by 3.9°:0 Air Leakage Testing Area-weighted a�erage fenestration SHGC Area-weighted average fenestration U-Factor Lighting Equipment Efficiency hlandatory code requirements that are not checked by Ekotrope must be met. hlechanical Ventilation Rate hlechanical Ventilation Efficacy Inspe�tion 5tatus Results are projected + TS��nergyS�lutir�ns As aesigned $1,438 $265 $197 $10 $1,911 $889 $0 $2,8�� Air sealing is 5.00 AGH at 50 Pa. It must not exceed 5.0� ACH at 5a Pa. Design ex�eeds requirements fvr Indiana 2n2� Perfvrmance compliance �hy 3.9°Io. As a 3rd party extension of the code jurisdi�tion utilizing these reports. I certify that this energy code complian�e document has been created in accordan�e with the requirements of Chapter 4 of the adopted Intemational Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certiTy that the building design des�ribed herein is consistent with the building plans, specifications, and other �al�ulations submitted �tiith the permit application. If rating is Confirmed, I �ertiT}� that the address referenced above has been inspected.+tested and that the mandatory pro�isions of the IECC have 6een installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Drganization f�latthew Timmons TSI Energy Solutians Signature: aate: 1!23!20 at 3:26 Pf�1 Ekotrope RATER - Version 3.1,a.2342 Indiana 202� Performance compliance results calculated using Ekotrope RATER's energ}� and code compliance algorithm, including appropriate amendments. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are 6ased on data entered 6y Ekotrope users. Ekotrope disclaims all lia6ility for the information shown on this report. 4359 P RAI RL E FALC� N D R Building Features Ceiling Atti�, R-38 Aboae Grade Walls R-1fi Foundation Walls R-1� Framed Floor NIA Slab R-�.� Perimeter, R-0.0 Under linfiltration 5 ACH50 Ii��Ci�Cal ZI�NSVILLE, IN �G��� Builder: PAIJL SH�OPMAN HOME 6UILOING �R�UP Duct Supply R-6.0, Return R-10.0 Duct Leakage to Outside 5 CFM251 10� ft2 Tatal auct Leakage 8 CFM251 10� ft2 (Post-Canstructiony Heating Furnace • hlatural Gas • 92.1 AFIJE Cooling Air Canditianer • Electri� • 13 SEER Water Heating Water Heater • Natural Gas •�.64 Energy Factar Window U-Value: 0.29, SHGC: 0.41 as a 3r� paity extei;si�n of t�e ecde jur,sd,c�,en Gt,lizii;g these repats, I cert,fy that �his zneryy cedz cc�ipliai;ce d�cu�iei:t �as been created in acceraa�ce �rrith ��e reqGire��2nts of Chapter 4 of the adopted International Energy Conservation Code dased on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent �tiith the building plans: specifications. and other calculations submitted with the permit application. If rating is Confrmed: I certiTy that the address referenced above has been inspected.+tested and that the mandatory provisions of the IECC hawe been installed to meet or exceed the intent ofthe IECC or vrill be verifed as such by another party. Name: Matthew Timmons S i g�natu re: arganizat'ion: TSI Energy Soluti�ns Date: 1123120 at 3:26 PM Ekotrope RATER - Version 3.'1.0.2342 Indiara 2C2ii vertiiicate cam� ance ras.alts calculated using Ekotrope RATER's energy and code compliance algorithm. includina appropriate ainendments. Ekot-ooe P,.=,TE4 is a�ESNETHcc-edited HERS Ratirg Tool ?,I resul:s are based on data an:e-ed o: =ho:rope �.sers. EE:o�r���e .: a=1a -is all lial: -.: i� t a in-c ma:ic� a�o::n o� :I� a r=��c �. Energy �ode Inspectian Checklist Praperty 4359 PRAIRIE FALCQN dR ZI�NSVILLE, IN 4fi077 Madel: HERON Community: WATERFR�NT AT UVE� WWC053 {AS DE5IGNED} WATERFRONTAT UVEST CLAY 53 �eneral Building Informatian Canditioned Area �sq ft} Canditioned Volume (�ubic ft) Insulated 5hell Area (sq fty ❑rganixatian TSI Energy Solutions Matthew Timmons 6uilder PALJL SHDDPMAN H�ME 6LJILaING GRDUP 4,361 45,282 10,266 Inspe�tion 5tatus Results are projected + TS��nergyS�lutir�ns The building energy model in Ekotrope reflects the building assemhlies and energy features listed below. Sometimes energy features will change in the field fram what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. 51ab � � � Name: BSMT�1,175 s.f., 64 ft. exterior perimeter} R-Q perimeter insulation, R-� under slab insulation. Name: CRAWL�F12 s.f., 82 ft. exterior perimeter� R-0 perimeter insulation, R-� under slab insulatian. Name: CRAWL�1,399 s.f., 124 ft. exterior perimeter} R-0 perimeter insulation, R-� under slab insulatian. Framed Flvar None Present Fvundatian Wall � Name: C�NDlAM6 UNFIN (Exterior Perimeter [ft]: 42, HeightAbove Grade [ft]: 1, ❑epth 6elow Grade [ft]: 8} R-10 continuous insulation, R-0 cavity insulatian Insulation Grade: I Feet from top af wall to tap of insulation: 0, Feet from top of wall to bottam of insulation: 4 � Name: C�NDlGAR UNFIN (Exterior Perimeter [ft]: 22, HeightAbove Grade [ft]: 1, ❑epth 6elaw Grade [ft]: 8} R-10 continuous insulatian, R-a cavity insulatian Insulation Grade: I Feet from top af wall to tap of insulation: 0, Feet from top of wall to bottom of insulatian: 4 � Name: CRAWLIAMB 1�Exterior Perimeter [ft]: 51, Height Above Grade [ft]: 1, aepth Below Grade [ft]: 2} R-10 continuous insulatian, R-0 cavity insulation Insulatian Grade: I Fully insulated (tap to hottom} Energy �ode Inspectian Checklist Praperty 4359 PRAIRIE FALCQN dR ZI�NSVILLE, IN 4fi077 Madel: HERON Community: WATERFR�NT AT UVE� WWC053 {AS DE5IGNED} WATERFR[JNTAT UVEST CLAY 53 ❑rganixatian TSI Energy Solutions Matthew Timmons 6uilder PALJL SHDDPMAN H�ME 6LJILaING GRDUP Inspe�tion 5tatus Results are projected + TS��nergyS�lutir�ns � Name: CRAWLIAMB ��Exterior Perimeter [ft]: 124, HeightAbove Grade [ft]: 1, aepth Below Grade [ft]: 2y R-10 continuous insulation, R-0 cavity insulation Insulation Grade: I Fully insulated (top to hottom} � Name: CRAWLIGARAGE 1(Exterior Perimeter [ft]: 31, HeightAbove Grade [ft]: 1, ❑epth Belaw Grade [ft]: 2} R-10 continuous insulatian, R-0 cavity insulatian Insulation Grade: I Fully insulated (tap to hottom} Abvve �rade Wall � Name: C�NDlAM6 �1,953 s.f.} R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I � Name: C�N DlGAR �477 s.f. y R-Q continuous insulatiQn, R-13 cavity insulation Insulation Grade: I Rim Jaist � � Ravf IVame: C�N DlAM 6�217 s.f. y R: 13.575 Name: C�NDlGAR �53 s.f.� R: 13.575 � Name: MAI N�3,186 s.f. y R-27.�5 continuaus insulation, R-1 D.15 �avity insulation Insulation Grade: I ❑paque Daar � Name: FR�NT (24 s.f.} U: 0.476 2 Energy �ode Inspectian Checklist Praperty 4359 PRAIRIE FALCQN dR ZI�NSVILLE, IN 4fi077 Madel: HERON Community: WATERFR�NT AT UVE� WWC053 {AS DE5IGNED} WATERFR[JNTAT UVEST CLAY 53 � Name: GARAGE (2� s.f.} U: 0.182 � Name: GARAGE (22 s.f.} U: 0.182 �lazing ❑rganixatian TSI Energy Solutions Matthew Timmons 6uilder PALJL SHDDPMAN H�ME 6LJILaING GRDUP Inspe�tion 5tatus Results are projected � Name: FR�NT (96 s.f.}, U: D.290, SHGC: 0.41, �rientation: S�UTH_EAST � Name: BACK (169 s.f.}, Ll: D.29D, SHGC: 0.41, Drientation: NORTH_WEST � Name: SLIDER (96 s.f.), U: 0.29fl, SHGC: 0.41, CJrientatian: NDRTH_WEST � Name: SLIDER (96 s.f.J, U: 0.290, SHGC: 0.41, Orientation: NDRTH_WEST � Name: BSMT [31 s.f.}, U: 0.290, SHGC: 0.41, Orientation: NORTH_WEST � Name: LEFT (45 s.f.}, Ll: D.290, SHGC: 0.41, �rientatian: SDUTH_UVEST � Name: RIGHT �43 s.f.}, lJ: 0.290, SHGC: D.41, ❑rientation: NDRTH_EAST 5kylight Nane Present Mechanical Ventilativn � Mechanical ventilation system rated for, and capable of, praviding cantinuous �entilation. System shall include automatic timing controls. System type: Exhaust �nly, 24 hrslday, 121Natts. Mechanical Equiprnent � HEATING • Natural Gas • 100°Io Heating Laad @ 9�.1 AFIJE + TS��nergyS�lutir�ns 3 � CD�LING • Ele�tric � 100°Io Cooling Load @ 13 SEER Energy �ode Inspectian Checklist Property ❑rganixatian Inspe�tion 5tatus 4359 PRAIRIE FALCQN aR TSI Energy Solutions Results are projected ZI�NSVILLE, IN 4fi077 Matthew Timmons Madel: HERON Community: WATERFR�NT AT UVE� 6uilder PALJL SHDDPMAN WWC053 {AS DE5IGNED} H�ME 6LJILaING WATERFRONTAT UVEST CLAY 53 GRDUP � Water Heating • Natural Gas • 100°Io Hot Water Load a� 0.64 Energy Fa�tor Air Leakage Cvntrvl � Test Status: Blawer-door tested Hause is air-sealed as to achieve 3,774 CFM50 �5.00 ACH50} ar less at final blower-doar test. Infiltration Requirements for IECC in Climate Zone 5 2a09 IECC Infiltration limit for the design home is 7 ACHS�. 2a12 IECC Infiltratian limit for the design home is 3 ACHS�. 2a15 IECC Infiltration limit f�r the design hame is 3 ACHS�. Duct Leakage Duct 5ystem 1 NOT entirely within conditioned space, testing required Leakage to ❑utside spe�ified as: 5 CFM251 1 DD ft2 Total Leakage spe�ified as: 8 CFM251 1D� ft2 �Post-Constru�tion} Duct Leakage Cvde Requirements fvr IECC 2a09 IECC: Postconstruction Leakage Test: auct Leakage ta Dutdoors �= 8 CFM251 100 sq ft CFR. Rough in Test with AHU: Total auct Leakage �= fi CFM251 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage �= 4 CFM251 1 a0 sq ft CFA. 2a12 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Tatal au�t Leaka�e �= 4 CFM25 ! 100 sq ft CFA. Rough in Test with AHU: Total auct Leakage c= 4 CFM251 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage �= 3 CFM251 1 a0 sq ft CFA. 2015 Performance Path �Cost Compliance}: + TS��nergyS�lutir�ns Leakage testing is required UNLESS all ducts and air handlers are lo�ated entirely within the thermal envelope. There is no passlfail threshold for duct leakage on the performance path. Praject Nates Building 5ummary Property 4359 PRAIRIE FALCON DR ZIDNSVILLE, IN 46077 h9odel: HERDN Communitv: 4"JATERFRDNT A7 VJEST CLAY 53 1NWC053 [AS DESIGNEDI �'+IA7ERFRaNTA.T :"dEST CL.4Y 5? General Building Infvrmation Number Df Bedrecr�s Number Of Floors Conditioned FlaorArea [sq. ft.] Unconditioned; atta�hed garage7 Conditioned Valume [�u. ft.] Total Units in Building Residence Type Flaar Number Madel Cammunity Climate Zone I Foundatian Wall Name COND.+AIr1B IJNFIN CCiND.`ia.s,� JyFIN C�'•„'—`F.';1E ' CRR�NL+AIr1B 2 CRA4"JL+GARAGE 1 Organ ization TSI Energy Solutians I,�atthew Timmons Builder PAUL SHaaPP�1AN HOf�1E BUIL�ING GRDIJP Inspectian Status Results are proje�ted 4 2 4;361 Yes 45;282 1 5ingle family detached HERON WATERFRaNTRT WEST CLAY 53 5A Library Type Height Above Grade Depth Below Grade R-10 Draped, 4f[ 1 8 R-10 Draped, 4f[ 1 8 R-10 Draped, Full 1 2 R-10 Draped, Full 1 2 R-10 Draped, Full 1 2 Foundatian Wall Library List Name Feet From Vh�all Top To Feet From Wall Top Ta Gontinuous Insulation Continuous Insulation Top Battam R-1� Draped, 4R o a R-1� Draped, Full N.+A N+'A Perimeter 42 22 51 124 31 Is Fully Insulated Cantinuous R•value No 10.0 � Yes 10.00 r TSICner�,�S�l�atir�ns Locatian Enclosing Exposed Exterior Conditioned Space Exposed Exterior Conditioned Space Exposed Exterior Conditioned Crawlspace Exposed Exterior Conditioned Crawlspace Exposed Exterior Conditioned Crawlspace Cavity R•value Effective Insulation R• �alue N.'A N.+A N.'A N.+A � Building 5ummary Property 4359 PRAIRIE FALCON DR ZIDNSVILLE, IN 46077 h9odel: HERDN Communitv: 4"JATERFRDNT A7 VJEST CLAY 53 1NWC053 [AS DESIGNEDI �'+IA7ERFRaNTA.T 4"JEST CLAY 53 � Slab Name Lihrary Type BSf�1T Llninsulated CRAti^!L Llninsulated CRAti^!L Llninsulated Organ ization TSI Energy Solutians I,�atthew Timmons Builder PAUL SHaaPP�1AN HOf�1E BUIL�ING GRDIJP Perimeter FloorGrade CarpetR Exposed 5urtaceArea Location Enclosing Masonry Area S4 Below Grade 1.23 � 1.175.D f[� Exposed Exterior Conditioned Spa�e 82 BeloU: Grade 1.2° � 612.D f[� Exposed Exterior Conditioned Crawlspa�e 124 Below Grade 1.23 � 1,399.D f[� Exposed Exterior Conditioned Crawlspa�e Slab Lihrary List Name Wall Construction 51ab Completely� llnderslah Perirneter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated ��food Frame ? Dther No 0 0 D No 6.00 Framed Flvar Framed Flvar Library List Rim Jvist Name CaN D.'APv16 CaN D.'GAR None Present Inspectian Status Results are proje�ted r TSICner�,�S�l�atir�ns None Present Library Type G1 R-13. R-3.0 G1 R-13. R-3.0 5 u rta ce A rea 217. � ft� 53. � ft� Lflcation Exposed Exterior Unconditioned. atta�hed garage � Building 5ummary Property 4359 PRAIRIE FALCON DR ZIDNSVILLE, IN 46077 h9odel: HERDN Communitv: 4"JATERFRDNT A7 VJEST CLAY 53 1NWC053 [AS DESIGNEDI �'+IA7ERFRaNTA.T :"dEST CL.4Y 5? Rim J�ist Library List Name G1 R-13. R-3.0 Wall Organ ization TSI Energy Solutians I,�atthew Timmons Builder PAUL SHaaPP�1AN HOf�1E BUIL�ING GRDIJP Effective Insulation R•value 13. 575 Inspectian Status Results are proje�ted r TSICner�,�S�l�atir�ns Name Liqrary Type Surtace Colar SurtaceArea Location C�ND.`Ah16 G1 R-13 BATT, R-3.0 I�ledium 1,953.D ft� Exposed Exterior CaND.'GAR G1 R-13 Gar4^Jalls h�ledium 477.D f[� Unconditioned. atta�hed garage Wall Library List = Name Effective R-value G1 R-13 6ATT. R-3.0 15.12 G1 R-13 GarVJalls 11.141 Glazing Name LiGrary Type Wall Assignment Foundation Wall O�erhang Depth Dverhang Ft To Overhan Ft To Assignment Tap �ottom BACK LI-29. SHGC-.41 COND.+AI;1B D � � BSh�1T lJ-.29. SHGC-.41 COND.+AP;1E C� 0 0 FRDNT 11-.29. SHGC-.41 COND.+AP;1E C� o 0 LEFT 11-.29. SHGC-.41 COND.+AI;1B D � � RIGHT 11-.29. SHGC-.41 COND.+A1;1E ,, � � SLIDER 11-.29. SHGC-.41 COND.+AI;1B D � � SLI6ER 1J-29. SHGC-.41 COND.+AP;1B ,. 0 0 Drientation SurfaceArea Northt�+est Northwest Southeast Southtivest Nor[heast Northwest Northtivest 169.� ft� 31.0 ft� 96.� ft� a5.o n= 43.� ft� 96.� ft� 96.0 ft� 3 Building 5ummary Property 4359 PRAIRIE FALCON DR ZIDNSVILLE, IN 46077 h9odel: HERDN Communitv: 4"JATERFRDNT A7 VJEST CLAY 53 1NWC053 [AS DESIGNEDI �'+IA7ERFRaNTA.T :"dEST CL.4Y 5? Glazing Library List Name 11-.29. SHGC-.41 Skylight Skylight Library List Organ ization TSI Energy Solutians I,�atthew Timmons Builder PAUL SHaaPP�1AN HOf�1E BUIL�ING GRDIJP 5hgc D.41 None Present None Present apaque Davr Name Library Type Wall Assignment Foundation Wall Assignment FRDNT 4"Joad Door COND.+AIr9B GARAGE Fiberglass+'Steel COND.+GAR Door GARAGE Fiberglass+'Steel COND.+GAR Door 4paque Dvvr Library List Name Fiberglass.+Steel Door 4"Joad Door Effective L!•factar �.182 �.476 Inspectian Status Results are proje�ted L! •fa cto r o.2sa r TSICner�,�S�l�atir�ns Emittance Solar SurfaceCalor SurtaceArea Lacation Aqsorptance �.9 0.75 f•;ledium 24.6 f[� Exposed Exterior �.9 0.75 f•;ledium 24.6 f[� Exposed Exterior �.9 0.75 f•;ledium 22.6 ft� Exposed Exterior 4 Building 5ummary Property 4359 PRAIRIE FALCON DR ZIDNSVILLE, IN 46077 h9odel: HERDN Communitv: 4"JATERFRDNT A7 VJEST CLAY 53 1NWC053 [AS DESIGNEDI �'+IA7ERFRaNTA.T :"dEST CL.4Y 5? Rovf Insulati�n Organ ization TSI Energy Solutians I,�atthew Timmons Builder PAUL SHaaPP�1AN HOf�1E BUIL�ING GRDIJP Inspectian Status Results are proje�ted Name Liqrary iype Attic ExteriorArea [s.f.] Clay or Concrete Roof 5urtace Color Tiles f•;1AIN R-38 Blo�tin. GR1 3.212 No F;ledium R�of Insulatian Lihrary List Name Has Radiant 8arrier Effective R-value R-38 Blown, GRi Na 38.268 Whale House Infiltrativn Infiltratiors Measuremant Type 5 ACH at 50 Pa Blo�tier-daor tested 5helter Class 4 r TSICner�,�S�l�atir�ns Surtace Area 3.186. � f[� Location Atti� Mechanical Ventila�ion * Ventilation Type Ventilation Rate [ft' f Dperationai haurs per day Fan Watts Runs once every three Energy Recavery Percent Minute] hours Exhaust Only 81.1 2d 12 No 0 Lighting °I Interior Fluarescent �<� Interior LED Lighting �: Exterior Fluarescent 'o Exterior LEO Lighting °� Garage Fluarescent �<� Garage LED Lighting Lighting Lighting Lighting 90 Q 9D � 90 0 �nsite Generation � None Present � Building 5ummary Property Organ ization 4359 PRAIRIE FALCON DR TSI Energy Solutians ZIDNSVILLE. IN 46077 I,�atthewTimmons h9odel: HERDN Communitv: 4"JATERFRDNT A7 VJEST CLAY 53 Builder PAUL SHaaPP�1AN HOf�1E 1NWC053 [AS DESIGNEDI BUIL�ING GRDIJP �'+IA7ERFRaNTA.T :"dEST CL.4Y 5? ❑nsite Generation Library List None Present 5olar Generativn � � None Present Solar Generativn Library List None Present Conditivning Equipment Name Liqrary Type CdDLI NG HEATI NG ��Iater Heating CA13NA�S� 9125A481D6S21 RGiPV56S`N Inspectian Status Results are proje�ted r TSICner�,�S�l�atir�ns Heating Percent Load Cooling Parcant Load Hot Water Percent Load 0°n 100°n 0°n 1 DO I 01 0°I D°o D°o 10C�=o Equiprnent Type: 9125A48'IOQS21 Fuel Ty;�e fVatural Gas Distributian Type Farced Air MatorType PSG {Single Speed} Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 93 Use default EAE No EAE [kWh] 756 IEquiprnent Type: CAI3NAQG4 Fuel Ty�e Electric Disiri�utian Type Farced Air MatorType PSG {Single Speed} Caoling Efficiency 13 SEER Cooling Capa�ity [kBtu.�h] 582 Location Conditioned Space Conditioned Space Conditioned Space .'�i Building 5ummary Property Organ ization 4359 PRAIRIE FALCON DR TSI Energy Solutians ZIDNSVILLE. IN 46077 I,�atthewTimmons h9odel: HERDN Communitv: 4"JATERFRDNT A7 VJEST CLAY 53 Builder PAUL SHaaPP�1AN HOf�1E 1NWC053 [AS DESIGNEDI BUIL�ING GRDIJP �'+IA7ERFRaNTA.T :"dEST CL.4Y 5? I Equiprnent Type: RG1PV54S*N Fuel Ty;�e Distri�utian Type Hot Water Efficien�y Tank Capacity {gal.} Hot Water Capa�ity [kBtu,'h] Recavery Efficiency Inspectian Status Results are proje�ted Natural Gas Hydranic Delivery 0.64 Energy Factar 5� 4[3 0.84 �Distributian System '�is�r�u�atio�-� Type Heating Equipment Coaling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply DuctArea [ftz] Return Duct Area [ftz] Leakage ta Outdaars TotalLeakage Total Leakage Duct Test Conditions Use Default Flaw Rate Duct 1 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 2 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 3 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 4 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 5 Duct Lacation Percent 5upply Rrea Percent ReturnArea Duct 6 Duct Lacation Percent 5upply Rrea Percent ReturnArea Geiling Fan IHas Ce��in[� Fan Cfm Per Wari Farced Air HEATIh1G CODLING 4361 4 � �o 1177.47 872.2 5 CFIv125 ? 14� ftZ 348.88 GFM25 Post-Canstruction Yes Attic {well vented; under insulation} 0 5� Conditioned 5pace �oo 5[? Conditianed 5pace 4 0 Conditianed 5pace 0 0 Conditianed 5pace 0 ❑ Conditianed Space 0 0 f�o �oo r TSICner�,�S�l�atir�ns Building 5ummary Property 4359 PRAIRIE FALCON DR ZIDNSVILLE, IN 46077 h9odel: HERDN Communitv: 4"JATERFRDNT A7 VJEST CLAY 53 1NWC053 [AS DESIGNEDI �'+IA7ERFRaNTA.T :"dEST CL.4Y 5? Water Distrihutian 4^Jater Fixture Type 5tandard Use Default Hot'�ti'ater Pipe Length No Hot Water Pipe Length [ft] 45 At Least R3 Pipe Insulatian7 No Hot Water Recirculation System7 N❑ Recirculation System Pipe Loop Length [ft] 10 Drain Water Heat Re�overy? No Clothes Dryer 'Fuel Tyae Cef Field Utilization Clvthes Washer Label E�ier�y �atinu Electric Rate Annual Gas Gost Gas Rate Capacity Imef Appliances and Gontrals Programr�a�le thermastat? Dishwasher Size Dishwasher Efficiency Range'Duen Fuel Canvectian Dven7 Ilnductian Range9 RefEigerator Consumption N�teS Inspectian Status Results are proje�ted Organ ization TSI Energy Solutians I,�atthew Timmons Builder PAUL SHaaPP�1AN HOf�1E BUIL�ING GRDIJP Electric 2.617 Timer Contrals ?��4 k'��rh Year S0.68?kWh 523.00 54.58rTherm 2.874 0.33053 Yss Standard 27� kWh Electric ND IVD �Q9 kWhlYear r TSICner�,�S�l�atir�ns :3