Loading...
HomeMy WebLinkAboutS 001 0Layout Name 50 Gramercy Description 9799 B Created June 21, 2019 Revised March 31, 2020 Builder David Weekley Homes Sales Rep Kas Oganowski Designer Blake Sorg Contract Lumber 200 Schofield Drive Columbus , OH 43213 614.751.1109 2nd Flr. I Joist (Flush) Label Description Width Depth Qty Plies Pcs Length J1 LPI 20Plus 2.5 14 4 4-8-14 J3 LPI 20Plus 2.5 14 1 17-9-12 J3 LPI 20Plus 2.5 14 12 17-9-6 J7 LPI 20Plus 2.5 14 11 21-9-12 J9 LPI 20Plus 2.5 14 3 17-9-12 J10 LPI 20Plus 2.5 14 2 22-9-12 F2 LPI 20Plus 2.5 14 1 22-9-12 LVL/LSL (Flush) Label Description Width Depth Qty Plies Pcs Length F1 LP-LVL 2900Fb-2.0E 1.75 14 2 6-0-0 F6 LP-LVL 2900Fb-2.0E 1.75 14 1 2 2 22-0-0 LVL/LSL (Dropped) Label Description Width Depth Qty Plies Pcs Length DB4 LP-LSL 1.35E 3.5 7.25 1 12-0-0 DB3 LP-LVL 2900Fb-2.0E 1.75 14 1 3 3 20-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 LP APA Rated OSB 1.125 X 14 1.125 14 12 12-0-0 Lumber (Dropped) Label Description Width Depth Qty Plies Pcs Length D1 SP #2 1.5 5.5 6 4-0-0 D2 SP #2 1.5 5.5 2 2 4 4-0-0 DB1 SP #2 1.5 9.25 1 2 2 6-0-0 DB2 SP #2 1.5 9.25 1 2 2 18-0-0 Hanger Beam/Girder Supported Member Label Pcs Description Skew Slope fasteners fasteners H1 1 IUS1.81/14 (Max) 14 10d 2 10dx1 1/2 H2 8 Unknown Hanger H3 16 IUS2.56/14 (Max) 14 10d 2 10dx1 1/2 2nd Flr. Design Method ASD (USA) Building Code IBC/IRC 2015 Floor Loads Live 40 Dead 10 Deflection Joist LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Deflection Girder LL Span L/ 480 TL Span L/ 240 LL Cant 2L/ 480 TL Cant 2L/ 240 Decking Decking OSB 23/32 APA Rated Sturd- I-Floor Fastener Nailed & Glued9'2"ADJUST PLUMBING TO AVOID JOIST FLANGE 10" HOLE CHASE 10" HOLE CHASE(3) 2x612" 12"24"24" X 24" 6K/8K START LAYOUTSE EMPIEZA AQUI16" O.C.24" O.C.SE EMPIEZA AQUISTART LAYOUTSE EMPIEZA AQUISTART LAYOUTE1N E1N A3 A3 A7 A7 A7 A3J1 @ 24"J9 @ 24" J3 @ 24" 2 X J3 J3 @ 24"J7 @ 16"2 X J10F1 ( 1 ply ) F1 ( 1 ply ) DB3 ( 3 ply )DB4 ( 1 ply )F6 ( 2 ply )DB2 ( 2 ply )DB1 ( 2 ply ) F2 ( 1 ply )D1 ( 1 ply )D1 ( 1 ply ) D1 ( 1 ply ) D1 ( 1 ply ) D1 ( 1 ply )D1 ( 1 ply )D2 ( 2 ply ) D2 ( 2 ply )PS H3H1 H3General Notes - It is the sole responsibility of the builder/installer to follow this layout exactly. Notify Contract Lumber of any discrepancies between this layout and field conditions. Contract Lumber is not liable for any field changes without prior approval. - Refer to details in the installation guide prior to construction ROOF GIRDER TRUSSD1 ( 1 ply )D1 ( 1 ply )D1 ( 1 ply ) D1 ( 1 ply )D1 ( 1 ply ) D1 ( 1 ply )D1 ( 1 ply ) D1 ( 1 ply )D1 ( 1 ply )D1 ( 1 ply ) D4 ( 1 ply )D4 ( 1 ply ) Roof Lumber Label Description Width Depth Qty Plies Pcs Length D1 SP #2 1.5 5.5 10 4-0-0 D4 SP #2 1.5 7.25 2 4-0-0 Version 19.80.180 Powered by iStruct This layout is to be used as an installation guide only. It is meant to be used in conjunction with the architectural and structural drawings, not to replace them 04/15/20 Mike Sheeks