HomeMy WebLinkAboutL-302_ADLSIL L I N O I S S T R E E T MEG(849.45) MEG(849.32) LP 850.00 849 851 85184884984684584 9 848847850851LP 850.50 LP 850.25 TR 851.20 BR 850.70 851 TR 851.25 BR 850.75TR 851.20 BR 850.70 FLUSH /MEG (849.55) MEG (849.05) TW 850.50 TW 849.00 TW 847.50 TS 848.00 BS 846.00 TS 845.65 BS 844.15 847846845849848848847846 LP 847.25850.585 0 850MEET & MATCH EXISTING GRADES AT TOP OF EXISTING CURB, TYP. MEET & MATCH EXISTING GRADES AT TOP OF EXISTING CURB, TYP. MEET & MATCH EXISTING GRADES AT TOP OF EXISTING CURB, TYP. 849 GABION WALL, SEE DETAIL A1 849850.5 TOP OF POND ELEV: 850.50 LP 848.90 LP 848.75 849850849850 851 850 849 8 5 0 8 5 1 HP 852.00 TR 850.50 BR 850.00 850849MEG(849.45) MEG(849.32) LP 850.25 TR 851.20 BR 850.70 851 FLUSH /MEG (849.55) MEG (849.05)849848847846850.5850LP 848.90 LP 848.75 850 850849TC 851.00 BC 850.50 COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO ARCHITECTS, INC. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO ARCHITECTS, INC. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. SHEET TITLE SHEET NUMBER SHEET ISSUE PROJECT NO. SEAL | DATE L-302 SITE GRADING PLAN - SOUTH 1 ADLS Intake 11/16/19 2 Issued for 100% DD 03/01/19 3 ADLS Revision 03/08/19 4 ADLS Revision 04/15/19 5 ADLS Cycle 3 Resubmittal 06/11/19 6 ADLS Cycle 5 Resubmittal 09/18/19 7 ADLS Addendum 1 04/01/20 09/18/19 A5 L-302 SITE GRADING PLAN - SOUTH 1"=30'-0" Owner Mechanical / Electrical Engineer Civil Engineer Architect / Landscape Architect 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 RATIO Architects, Inc. 11460 N Meridian Street Carmel, IN 46032 317-705-5050 ZP Investments, LLC ZP Investments, LLC Office North Illinois ST Carmel, IN 46032 Structural Engineer 10 ShoShone Dr. Carmel, IN 46032 317-324-6024 18087.001 3850 Priority Way S. Dr #204 Indianapolis, IN 46240 317-571-8795 Heapy Engineering 530 E. Ohio Street G Indianapolis, IN 46204 317-655-7777 Civil and Environmental Consultants, Inc. CE Solutions MATCHLINE - SEE L-301 I L L INO I S S T R E E T ( PU B L I C R IG H T -O F -W A Y ) MATCHLINE - SEE L-301 PROPERTY LINE SETBACK LINE 1.COORDINATE ALL WORK WITH OTHER DESIGN DISCIPLINES. 2.CONTRACTOR SHALL VERIFY ALL VERTICAL AND HORIZONTAL DIMENSIONS AND FIELD CONDITIONS PRIOR TO STARTING WORK. CONTRACTOR IS RESPONSIBLE FOR ALL FIELD DIMENSIONS. IF CONTRACTOR FINDS ANY DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD DIMENSIONS OR CONDITIONS, CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY. 3.PARTICIPATE IN THE PRE-INSTALLATION CONFERENCE FOR THE GRADING AND DRAINAGE SCOPE OF THE WORK, ACCORDING TO THE PROJECT SPECIFICATIONS, PRIOR TO COMMENCEMENT. 4.EXISTING AND PROPOSED UTILITIES THAT ARE SHOWN ARE FOR REFERENCE ONLY. REFER TO THE SITE SURVEY FOR EXISTING UTILITIES AND VERIFY IN THE FIELD. REFER TO THE SITE ELECTRICAL PLAN FOR THE PROPOSED LIGHTING AND OUTLETS. 5.TYPICAL MAXIMUM SIDEWALK CROSS SLOPES ARE 2% (1/4" PER 1'-0"). TYPICAL MAXIMUM SIDEWALK LONGITUDINAL SLOPES ARE 5% (1'-0" PER 20'-0"). 6.WHERE NEW PAVED SURFACES ADJOIN EXISTING PAVED SURFACES, MEET EXISTING GRADE. 7.DRAINAGE DESIGN SHOWN IS CONCEPTUAL. PLEASE SEE CIVIL DRAWINGS FOR MORE COMPLETE AND DETAILED STORMWATER DRAINAGE DESIGN. SITE GRADING PLAN GENERAL NOTES: 5 CONSTRUCTION LIMITS 6 7