HomeMy WebLinkAboutOBF-104 Seal Truss Drawings16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). March 12,2020 Liu, Xuegang Pages or sheets covered by this seal: I40589667 thru I40589741 My license renewal date for the state of Indiana is July 31, 2020. B19902043 FISCHER OBF-104 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss CG01 Truss Type Diagonal Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589667 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:16 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-GkAwYtyZ1TjvVMNVGNw9yjlQAv?fK4eRbH4CTJzblW1 Scale = 1:15.5 1 2 3 4 7 6 52x4 2x4 2x4 2x4 2-8-7 2-7-14 -1-9-10 1-9-10 2-7-7 2-7-7 2-8-7 0-1-0 1-0-02-4-12-6-06.66 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.23 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)7=0-5-3, 6=Mechanical Max Horz 7=73(LC 27) Max Uplift 7=-40(LC 8), 6=-19(LC 5) Max Grav 7=233(LC 1), 6=67(LC 15) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 40 lb uplift at joint 7 and 19 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 65 lb down and 90 lb up at 0-3-4 on top chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-14, 5-7=-20 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss CG02 Truss Type Diagonal Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589668 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:17 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-kxjJmDzBomrm7Wyhq5ROVxHbwILw3Xtaqxpm?lzblW0 Scale = 1:15.5 1 2 3 4 7 6 52x4 2x4 2x4 2x4 2-8-7 2-7-14 -1-9-10 1-9-10 2-8-7 2-8-7 1-0-02-3-122-6-06.66 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.23 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)7=0-5-3, 6=Mechanical Max Horz 7=72(LC 5) Max Uplift 7=-39(LC 8), 6=-18(LC 5) Max Grav 7=232(LC 1), 6=67(LC 15) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 39 lb uplift at joint 7 and 18 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 65 lb down and 90 lb up at 0-3-4 on top chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-14, 5-7=-20 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss CG03 Truss Type Diagonal Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589669 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:18 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-C7HhzZzpY4zckgXtNoyd28qmgig8o_7k3bZJXBzblW? Scale = 1:18.8 1 2 3 4 7 6 5 8 9 2x4 2x4 2x4 2x4 3-10-12 3-10-3 -1-9-10 1-9-10 3-9-12 3-9-12 3-10-12 0-1-0 1-0-03-0-03-1-156.66 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.23 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-5-3, 6=Mechanical Max Horz 7=91(LC 5) Max Uplift 7=-58(LC 8), 6=-36(LC 8) Max Grav 7=248(LC 1), 6=121(LC 34) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint 7 and 36 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 43 lb up at 1-5-11, and 42 lb down and 83 lb up at 1-5-13 on top chord, and 3 lb down and 1 lb up at 1-5-11, and 11 lb down and 18 lb up at 1-5-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-14, 5-7=-20 Concentrated Loads (lb) Vert: 8=21(F) 9=4(F=3, B=1) March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss CG04 Truss Type Diagonal Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589670 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:19 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-hJr3Bv_RJO6TMq54xVTsaMNxQ60QXRNtIFIs4ezblW_ Scale = 1:18.8 1 2 3 4 7 6 5 8 9 2x4 2x4 2x4 2x4 3-10-12 3-10-3 -1-9-10 1-9-10 3-10-12 3-10-12 1-0-02-11-123-1-156.66 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.23 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-5-3, 6=Mechanical Max Horz 7=91(LC 27) Max Uplift 7=-58(LC 8), 6=-36(LC 8) Max Grav 7=246(LC 1), 6=121(LC 34) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint 7 and 36 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 43 lb up at 1-5-11, and 42 lb down and 83 lb up at 1-5-13 on top chord, and 3 lb down and 1 lb up at 1-5-11, and 11 lb down and 18 lb up at 1-5-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-14, 5-7=-20 Concentrated Loads (lb) Vert: 8=21(B) 9=4(F=1, B=3) March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss CG05 Truss Type Diagonal Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589671 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:20 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-9WPROE?34hEK__gGVD?57Zv6AWMfGud1Wv2Qb4zblVz Scale = 1:18.8 1 2 3 4 7 6 5 8 9 2x4 2x4 2x4 2x4 3-10-14 3-10-5 -1-9-10 1-9-10 3-10-14 3-10-14 1-0-02-11-123-2-06.66 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.23 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-5-3, 6=Mechanical Max Horz 7=91(LC 5) Max Uplift 7=-58(LC 8), 6=-36(LC 8) Max Grav 7=247(LC 1), 6=121(LC 34) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint 7 and 36 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 43 lb up at 1-5-11, and 42 lb down and 82 lb up at 1-5-14 on top chord, and 3 lb down and 1 lb up at 1-5-11, and 11 lb down and 18 lb up at 1-5-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-14, 5-7=-20 Concentrated Loads (lb) Vert: 8=21(B) 9=4(F=1, B=3) March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss CG06 Truss Type Diagonal Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589672 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:21 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-dizpca0hr?MBb8FS3wWKfnSGwwir?LtAlZnz7WzblVy Scale = 1:18.8 1 2 3 4 7 6 5 8 9 2x4 2x4 2x4 2x4 3-10-14 3-10-5 -1-9-10 1-9-10 3-9-14 3-9-14 3-10-14 0-1-0 1-0-03-0-13-2-06.66 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.23 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-5-3, 6=Mechanical Max Horz 7=91(LC 25) Max Uplift 7=-58(LC 8), 6=-36(LC 8) Max Grav 7=248(LC 1), 6=122(LC 34) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 58 lb uplift at joint 7 and 36 lb uplift at joint 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 43 lb up at 1-5-11, and 42 lb down and 82 lb up at 1-5-14 on top chord, and 3 lb down and 1 lb up at 1-5-11, and 11 lb down and 18 lb up at 1-5-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-14, 5-7=-20 Concentrated Loads (lb) Vert: 8=21(F) 9=4(F=3, B=1) March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss CG07 Truss Type Diagonal Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589673 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:21 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-dizpca0hr?MBb8FS3wWKfnSGJwja?LtAlZnz7WzblVy Scale = 1:11.3 1 2 3 4 7 6 53x12 2x4 2x4 1-3-15 1-3-12 -2-6-11 2-6-11 1-1-7 1-1-7 1-3-15 0-2-8 1-1-31-5-141-8-05.15 12 Plate Offsets (X,Y)-- [2:0-0-9,0-1-4], [7:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.00 (loc) 7 7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-3-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)7=0-3-10, 5=Mechanical Max Horz 7=60(LC 9) Max Uplift 7=-110(LC 6), 5=-112(LC 1) Max Grav 7=346(LC 1), 5=59(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-365/426 NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 7 and 112 lb uplift at joint 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss GE01 Truss Type Common Supported Gable Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589674 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:23 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Z55a0G1yNccvrRPrALYolCXevjOlTEnTDtG4CPzblVw Scale = 1:41.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 40 41 2x4 2x4 4x6 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-0-0 24-0-0 12-0-0 12-0-0 24-0-0 12-0-0 25-0-0 1-0-0 0-10-124-10-120-10-124.00 12 Plate Offsets (X,Y)-- [30:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.07 0.02 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 20 20 21 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 99 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 24-0-0. (lb) - Max Horz 39=-43(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 39, 21, 31, 32, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24, 23, 22 Max Grav All reactions 250 lb or less at joint(s) 39, 21, 30, 31, 32, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24, 23, 22 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-1-12 to 3-1-12, Exterior(2N) 3-1-12 to 9-0-0, Corner(3R) 9-0-0 to 15-0-0, Exterior(2N) 15-0-0 to 22-0-0, Corner(3E) 22-0-0 to 25-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 39, 21, 31, 32, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24, 23, 22. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss GE02 Truss Type Common Structural Gable Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589675 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:24 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-1HfyEc2a8wkmSb_1k331HP4jH7hlCgfcRX0dkrzblVv Scale = 1:43.0 1 2 3 4 5 8 7 6 21 22 23 24 4x6 4x6 4x6 2x4 3x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 4-11-4 4-11-4 9-10-8 4-11-4 -1-0-0 1-0-0 4-11-4 4-11-4 9-10-8 4-11-4 10-10-8 1-0-0 1-6-86-5-121-6-812.00 12 Plate Offsets (X,Y)-- [6:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.47 0.22 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.00 (loc) 7 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-1-8, 6=0-1-8 Max Horz 8=-145(LC 8) Max Uplift 8=-22(LC 10), 6=-22(LC 11) Max Grav 8=468(LC 18), 6=468(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-370/128, 3-4=-370/128, 2-8=-365/186, 4-6=-365/186 WEBS 3-7=0/250 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 7-10-8, Exterior(2E) 7-10-8 to 10-10-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8, 6. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss GE03 Truss Type GABLE Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589676 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:25 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-VTCKRy3CvEsd4lZEImaGqdcw3X??x2gmgBlBGHzblVu Scale = 1:64.9 1 2 3 4 5 10 9 8 6 11 7 3x4 3x6 2x4 2x4 3x6 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 1-8-85-11-121-11-8 1-11-8 2-0-0 0-0-8 9-2-0 7-2-0 -1-0-0 1-0-0 1-11-8 1-11-8 9-2-0 7-2-8 1-6-810-8-810-2-00-6-812.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.34 0.35 0.40 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.16 -0.05 (loc) 6-7 6-7 6 l/defl >924 >511 n/a L/d 240 180 n/a PLATES MT20 Weight: 60 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6,2-10: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-6 REACTIONS. (size)6=7-2-0, 10=0-1-8, 7=0-3-8 Max Horz 10=292(LC 7) Max Uplift 6=-163(LC 7), 10=-129(LC 6) Max Grav 6=312(LC 17), 10=200(LC 18), 7=420(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-263/92 BOT CHORD 7-8=-269/124, 6-7=-269/124 WEBS 3-8=-271/0 NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 1-10-4, Interior(1) 1-10-4 to 9-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 1-4-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=163, 10=129. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss GE04 Truss Type Common Supported Gable Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589677 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:26 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-zgmifI3qgX_Uiv8QrU6VMq98yxPhgZ6vvrVkokzblVt Scale = 1:56.7 1 2 3 4 5 6 7 8 9 10 11 12 13 26 25 24 23 22 21 20 19 18 17 16 15 14 27 28 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 15-0-0 15-0-0 7-6-0 7-6-0 15-0-0 7-6-0 1-1-08-7-01-1-012.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.07 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-20 REACTIONS.All bearings 15-0-0. (lb) - Max Horz 26=159(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 21, 22, 23, 24, 19, 18, 17, 16 except 26=-176(LC 8), 14=-149(LC 9), 25=-171(LC 10), 15=-163(LC 11) Max Grav All reactions 250 lb or less at joint(s) 26, 14, 20, 21, 22, 23, 24, 25, 19, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-125/252, 7-8=-125/252 WEBS 7-20=-285/114 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-1-12 to 3-1-12, Exterior(2N) 3-1-12 to 4-6-0, Corner(3R) 4-6-0 to 10-6-0, Exterior(2N) 10-6-0 to 11-10-4, Corner(3E) 11-10-4 to 14-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 22, 23, 24, 19, 18, 17, 16 except (jt=lb) 26=176, 14=149, 25=171, 15=163. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss GE05 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589678 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:28 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-w2uT4_54C9ECxCHpzu8zSFENKk5m8U2CM8_rtczblVr Scale = 1:56.2 1 2 3 4 5 6 7 13 12 11 10 9 8 14 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-11-4 8-11-4 0-0-48-11-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.60 0.03 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-8 REACTIONS.All bearings 8-11-4. (lb) - Max Horz 1=236(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 9, 10, 11, 12, 13 Max Grav All reactions 250 lb or less at joint(s) 1, 8, 9, 10, 11, 12, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-337/164 NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-4-4 to 3-7-4, Exterior(2N) 3-7-4 to 5-9-8, Corner(3E) 5-9-8 to 8-9-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 9, 10, 11, 12, 13. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss GE06 Truss Type Monopitch Supported Gable Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589679 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:28 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-w2uT4_54C9ECxCHpzu8zSFEVkk4n8UcCM8_rtczblVr Scale = 1:27.0 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 18 10 3x12 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 11-11-8 11-11-8 0-4-04-1-84-3-134.00 12 Plate Offsets (X,Y)-- [9:0-8-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.12 0.09 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 10-11. REACTIONS.All bearings 11-11-8. (lb) - Max Horz 2=127(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 12, 13, 14, 15, 16, 17, 11 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 12, 13, 14, 15, 11 except 17=299(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 8-8-0, Corner(3E) 8-8-0 to 11-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 12, 13, 14, 15, 16, 17, 11. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss GE07 Truss Type Common Supported Gable Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589680 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:30 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-sR0DUf7LkmUvAWRB4JARXgKsNYnMcPAVqSTyyVzblVp Scale = 1:42.9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 36 37 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 22-0-0 22-0-0 -1-0-0 1-0-0 11-0-0 11-0-0 22-0-0 11-0-0 23-0-0 1-0-0 0-6-06-0-00-6-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.05 0.02 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 19 19 18 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 99 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-0-0. (lb) - Max Horz 2=-74(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 29, 30, 31, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 28, 29, 30, 31, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 8-0-0, Corner(3R) 8-0-0 to 14-0-0, Exterior(2N) 14-0-0 to 20-0-0, Corner(3E) 20-0-0 to 23-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 29, 30, 31, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20, 18. 9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2, 18. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J01 Truss Type Jack-Closed Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589681 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:31 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Kdabi?7zU4cmog0Ne1hg3uszVy5kLpJe26CVUxzblVo Scale = 1:15.5 1 2 3 4 5 9 8 7 6 10 2x4 2x4 3x4 3x4 2x4 2x4 2x4 3x6 2-2-0 2-2-0 4-2-5 2-0-5 -1-0-0 1-0-0 1-6-5 1-6-5 2-2-0 0-7-11 4-2-5 2-0-5 1-0-02-5-12-6-51-5-90-11-81-9-10-8-02-5-112.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-1-8], [6:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.28 0.14 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.02 (loc) 8 8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)9=0-3-8, 6=0-1-8 Max Horz 9=65(LC 5) Max Uplift 9=-56(LC 8), 6=-57(LC 5) Max Grav 9=265(LC 1), 6=180(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 53 lb down and 41 lb up at 1-6-5, and 67 lb down and 40 lb up at 2-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J01 Truss Type Jack-Closed Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589681 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:31 2020 Page 2 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Kdabi?7zU4cmog0Ne1hg3uszVy5kLpJe26CVUxzblVo LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-5=-54, 8-9=-20, 6-7=-20 Concentrated Loads (lb) Vert: 8=-63(B) 10=-31(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J02 Truss Type Jack-Closed Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589682 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:32 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-op8zvL8bFNkdQqbaCkCvc5P9ELSx4IQoHmy20NzblVn Scale = 1:22.3 1 2 3 4 5 9 8 7 6 2x4 3x4 3x4 2x4 2x4 2x4 2x4 3x6 2-2-0 2-2-0 4-2-5 2-0-5 -1-0-0 1-0-0 2-2-0 2-2-0 2-10-5 0-8-5 4-2-5 1-4-0 1-0-03-8-83-10-52-9-00-11-83-0-80-8-03-8-812.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4], [4:0-2-2,0-1-8], [6:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.08 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 -0.02 (loc) 7 8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)9=0-3-8, 6=0-1-8 Max Horz 9=100(LC 7) Max Uplift 9=-13(LC 10), 6=-45(LC 7) Max Grav 9=214(LC 1), 6=138(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J03 Truss Type Jack-Closed Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589683 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:33 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-G0hM7h9D0hsU2_AmmSk89JyKMlm?pmrxWQhcYqzblVm Scale = 1:15.5 1 2 3 4 6 578 2x4 2x4 3x4 2x4 3x6 1-6-5 1-6-5 4-2-5 2-8-0 -1-0-0 1-0-0 1-6-5 1-6-5 4-2-5 2-8-0 1-0-02-5-12-6-52-1-90-3-82-5-112.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-1-8], [5:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.21 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.03 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=72(LC 7) Max Uplift 6=-55(LC 8), 5=-58(LC 5) Max Grav 6=262(LC 1), 5=183(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 54 lb down and 41 lb up at 1-6-5, and 67 lb down and 39 lb up at 2-3-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J03 Truss Type Jack-Closed Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589683 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:33 2020 Page 2 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-G0hM7h9D0hsU2_AmmSk89JyKMlm?pmrxWQhcYqzblVm LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-54, 5-6=-20 Concentrated Loads (lb) Vert: 7=-30(F) 8=-63(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J04 Truss Type Jack-Closed Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589684 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:33 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-G0hM7h9D0hsU2_AmmSk89JyKKloSpmrxWQhcYqzblVm Scale = 1:22.3 1 2 3 4 6 5 2x4 2x4 3x4 2x4 2x4 2-10-5 2-10-5 4-2-5 1-4-0 -1-0-0 1-0-0 2-10-5 2-10-5 4-2-5 1-4-0 1-0-03-8-83-10-53-5-00-3-83-8-812.00 12 Plate Offsets (X,Y)-- [3:0-2-2,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=108(LC 7) Max Uplift 6=-14(LC 10), 5=-46(LC 7) Max Grav 6=214(LC 1), 5=138(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J05 Truss Type Jack-Open Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589685 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:34 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-kCFkK1Arn?_Lf7lyJ9FNhWUXn99EYD55k4R95GzblVl Scale = 1:12.5 1 2 5 3 43x6 1-10-6 1-10-6 -1-0-0 1-0-0 1-10-6 1-10-6 0-8-01-10-151-5-111-10-158.00 12 Plate Offsets (X,Y)-- [2:0-0-13,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=47(LC 10) Max Uplift 5=-12(LC 10), 3=-25(LC 10) Max Grav 5=143(LC 1), 3=35(LC 17), 4=32(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J06 Truss Type Jack-Open Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589686 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:35 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-DOp6YNATYI7CHHK9ttmcEk1iXZUTHgLEzkAidizblVk Scale = 1:12.5 1 2 5 3 43x6 1-10-6 1-10-6 -1-0-0 1-0-0 1-10-6 1-10-6 0-8-01-10-151-5-111-10-158.00 12 Plate Offsets (X,Y)-- [2:0-0-13,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.09 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=47(LC 10) Max Uplift 5=-12(LC 10), 3=-25(LC 10) Max Grav 5=143(LC 1), 3=35(LC 17), 4=32(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J07 Truss Type Jack-Closed Girder Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589687 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:36 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-hbNUljB6JcF3vRvLRaHrmxaplzkN07aNCOwG99zblVj Scale = 1:18.8 1 2 3 4 6 578 3x4 2x4 3x4 3x4 3x8 2-2-5 2-2-5 4-10-5 2-8-0 -1-0-0 1-0-0 2-2-5 2-2-5 4-10-5 2-8-0 1-0-03-1-13-2-52-9-90-3-83-1-112.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-1-8], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.38 0.43 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.04 -0.07 -0.00 (loc) 5-6 5-6 5 l/defl >999 >760 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-5 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=91(LC 28) Max Uplift 6=-62(LC 8), 5=-84(LC 5) Max Grav 6=321(LC 1), 5=262(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 93 lb down and 60 lb up at 2-2-5, and 104 lb down and 48 lb up at 2-11-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J07 Truss Type Jack-Closed Girder Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589687 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:36 2020 Page 2 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-hbNUljB6JcF3vRvLRaHrmxaplzkN07aNCOwG99zblVj LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-54, 5-6=-20 Concentrated Loads (lb) Vert: 7=-79(B) 8=-103(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J08 Truss Type Jack-Closed Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589688 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:37 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-9nxsz2Ck4wNwWbUX?Ho4J96_xM8dlaqXR2fphbzblVi Scale = 1:25.6 1 2 3 4 6 5 2x4 2x4 3x4 3x4 2x4 3-6-5 3-6-5 4-10-5 1-4-0 -1-0-0 1-0-0 3-6-5 3-6-5 4-10-5 1-4-0 1-0-04-4-84-6-54-1-00-3-84-4-812.00 12 Plate Offsets (X,Y)-- [3:0-2-2,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.29 0.17 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-5 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=127(LC 7) Max Uplift 6=-12(LC 10), 5=-54(LC 7) Max Grav 6=237(LC 1), 5=163(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J09 Truss Type Jack-Closed Qty 19 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589689 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:38 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-dzVFAODMrDVn8l2kY?JJsMf9GmUkU14gfiPNE1zblVh Scale = 1:32.4 1 2 3 5 4 3x12 3x4 2x4 -1-0-0 1-0-0 4-10-5 4-10-5 1-0-05-10-55-6-130-3-85-10-512.00 12 Plate Offsets (X,Y)-- [2:0-1-4,0-1-4], [3:0-0-9,0-1-8], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.31 0.18 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=163(LC 9) Max Uplift 5=-1(LC 6), 4=-78(LC 7) Max Grav 5=243(LC 18), 4=200(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J10 Truss Type Jack-Closed Qty 7 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589690 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:39 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-5A3dNkE_cXdemvdw6iqYOaCJrAqwDUKquM8wmTzblVg Scale = 1:32.4 1 2 4 3 3x12 3x4 2x4 4-10-5 4-10-5 1-0-05-10-55-6-130-3-85-10-512.00 12 Plate Offsets (X,Y)-- [1:0-1-4,0-1-4], [2:0-0-9,0-1-8], [4:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.32 0.18 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.00 (loc) 3-4 3-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-3: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-8, 3=0-1-8 Max Horz 4=149(LC 7) Max Uplift 4=-3(LC 6), 3=-78(LC 7) Max Grav 4=199(LC 18), 3=206(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J11 Truss Type Jack-Closed Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589691 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:39 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-5A3dNkE_cXdemvdw6iqYOaCN_Ar8DUKquM8wmTzblVg Scale = 1:18.9 1 2 3 5 4 3x6 2x4 2x4 3-9-7 3-9-7 -1-0-0 1-0-0 3-9-7 3-9-7 0-8-03-2-58.00 12 Plate Offsets (X,Y)-- [2:0-0-13,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=Mechanical Max Horz 5=87(LC 7) Max Uplift 5=-20(LC 10), 4=-28(LC 10) Max Grav 5=201(LC 1), 4=134(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J12 Truss Type Jack-Open Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589692 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:40 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-ZMc?b4EcNrlVN2C6gQMnxnkWaaB_yxaz70uTIwzblVf Scale = 1:12.4 1 2 5 3 43x12 0-10-6 0-10-6 -1-0-0 1-0-0 0-10-6 0-10-6 1-0-01-10-60-6-71-3-151-10-612.00 12 Plate Offsets (X,Y)-- [2:0-1-4,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 0-10-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=41(LC 10) Max Uplift 3=-18(LC 1), 4=-15(LC 10) Max Grav 5=131(LC 1), 3=8(LC 6), 4=17(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J13 Truss Type Jack-Open Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589693 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:41 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-1YANoQFE88tM?CnIE7t0T?HhK_WDhOq6Lgd1qMzblVe Scale = 1:12.4 1 2 5 3 43x12 0-10-6 0-10-6 -1-0-0 1-0-0 0-10-6 0-10-6 1-0-01-10-61-3-151-10-612.00 12 Plate Offsets (X,Y)-- [2:0-1-4,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 0-10-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=41(LC 10) Max Uplift 3=-18(LC 1), 4=-15(LC 10) Max Grav 5=131(LC 1), 3=8(LC 6), 4=17(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J14 Truss Type Jack-Closed Girder Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589694 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:42 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Vlkl0mGsvS?DdMMVnrOF0CqqENnlQq4GaKNaNozblVd Scale = 1:18.8 1 2 3 4 6 578 3x4 2x4 3x4 3x4 3x8 2-2-5 2-2-5 4-10-5 2-8-0 -1-0-0 1-0-0 2-2-5 2-2-5 4-10-5 2-8-0 1-0-03-1-13-2-52-9-90-3-83-1-112.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-1-8], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.38 0.43 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.04 -0.07 -0.00 (loc) 5-6 5-6 5 l/defl >999 >758 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-5 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=91(LC 5) Max Uplift 6=-62(LC 8), 5=-84(LC 5) Max Grav 6=321(LC 1), 5=263(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 93 lb down and 60 lb up at 2-2-5, and 104 lb down and 48 lb up at 2-11-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J14 Truss Type Jack-Closed Girder Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589694 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:42 2020 Page 2 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Vlkl0mGsvS?DdMMVnrOF0CqqENnlQq4GaKNaNozblVd LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-54, 5-6=-20 Concentrated Loads (lb) Vert: 7=-79(B) 8=-103(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J15 Truss Type Jack-Closed Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589695 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:42 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Vlkl0mGsvS?DdMMVnrOF0CqrhNroQq4GaKNaNozblVd Scale = 1:25.6 1 2 3 4 6 5 2x4 2x4 3x4 3x4 2x4 3-6-5 3-6-5 4-10-5 1-4-0 -1-0-0 1-0-0 3-6-5 3-6-5 4-10-5 1-4-0 1-0-04-4-84-6-54-1-00-3-84-4-812.00 12 Plate Offsets (X,Y)-- [3:0-2-2,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.29 0.17 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-5 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=127(LC 7) Max Uplift 6=-12(LC 10), 5=-54(LC 7) Max Grav 6=237(LC 1), 5=163(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J16 Truss Type Jack-Closed Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589696 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:43 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-_xI8D6HVgm73EWxhLYvUZQM3ynC39HJPp_68vFzblVc Scale = 1:18.9 1 2 3 5 4 3x6 2x4 2x4 3-9-8 3-9-8 -1-0-0 1-0-0 3-9-8 3-9-8 0-8-03-2-58.00 12 Plate Offsets (X,Y)-- [2:0-0-13,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=Mechanical Max Horz 5=87(LC 9) Max Uplift 5=-20(LC 10), 4=-28(LC 10) Max Grav 5=201(LC 1), 4=135(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J17 Truss Type Jack-Open Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589697 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:44 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-S7sWRSH7R3FwsgWtvGQj5dvCYBYwukZZ2eshRhzblVb Scale = 1:12.4 1 2 5 3 43x12 0-10-7 0-10-7 -1-0-0 1-0-0 0-10-7 0-10-7 1-0-01-10-71-4-01-10-712.00 12 Plate Offsets (X,Y)-- [2:0-1-4,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 0-10-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=41(LC 10) Max Uplift 3=-17(LC 1), 4=-15(LC 10) Max Grav 5=131(LC 1), 3=8(LC 6), 4=17(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J18 Truss Type Jack-Open Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589698 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:45 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-wJQueoIlBNNnUq54TzxyerRNIbu9dBpiGIbEz7zblVa Scale = 1:12.4 1 2 5 3 43x12 0-10-7 0-10-7 -1-0-0 1-0-0 0-10-7 0-10-7 1-0-01-10-71-4-01-10-712.00 12 Plate Offsets (X,Y)-- [2:0-1-4,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 0-10-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=41(LC 10) Max Uplift 3=-17(LC 1), 4=-15(LC 10) Max Grav 5=131(LC 1), 3=8(LC 6), 4=17(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J19 Truss Type Jack-Closed Qty 6 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589699 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:45 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-wJQueoIlBNNnUq54TzxyerRMBbuYdAfiGIbEz7zblVa Scale = 1:29.1 1 2 3 4 8 7 6 5 3x12 3x4 2x4 2x4 2x4 2x4 2-2-0 2-2-0 4-2-5 2-0-5 -1-0-0 1-0-0 2-2-0 2-2-0 4-2-5 2-0-5 1-0-05-2-54-2-130-11-84-6-50-8-012.00 12 Plate Offsets (X,Y)-- [2:0-1-4,0-1-4], [4:0-0-9,0-1-8], [8:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.27 0.10 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.05 -0.04 -0.02 (loc) 7 7 5 l/defl >939 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 5=0-1-8 Max Horz 8=136(LC 7) Max Uplift 8=-2(LC 6), 5=-70(LC 7) Max Grav 8=217(LC 18), 5=171(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J20 Truss Type Jack-Closed Qty 10 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589700 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:46 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-OW_Gr7JNyhVe5zgG0gTBA2_YC?EPMe3sVyLoWZzblVZ Scale = 1:29.1 1 2 3 5 4 3x12 3x4 2x4 4-2-5 4-2-5 -1-0-0 1-0-0 4-2-5 4-2-5 1-0-05-2-54-10-130-3-85-2-512.00 12 Plate Offsets (X,Y)-- [2:0-1-4,0-1-4], [3:0-0-9,0-1-8], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.25 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=144(LC 7) Max Uplift 5=-3(LC 6), 4=-70(LC 7) Max Grav 5=217(LC 18), 4=171(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J21 Truss Type Jack-Closed Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589701 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:47 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-siYe3TK?j_dVj7ESaO_QjGXlfOa755t?kc4L20zblVY Scale = 1:15.6 1 2 3 4 8 7 6 5 3x6 2x4 2x4 2x4 2x4 2x4 2-2-0 2-2-0 2-9-8 0-7-8 -1-0-0 1-0-0 2-2-0 2-2-0 2-9-8 0-7-8 0-8-02-6-51-10-50-8-08.00 12 Plate Offsets (X,Y)-- [2:0-0-13,0-1-4], [8:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 6 7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 5=Mechanical Max Horz 8=61(LC 7) Max Uplift 8=-19(LC 10), 5=-20(LC 10) Max Grav 8=168(LC 1), 5=92(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J22 Truss Type Jack-Closed Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589702 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:48 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Ku51GpLdUIlMLHpf85VfGT3wSow3qYZ8yGqvaSzblVX Scale = 1:15.6 1 2 3 5 4 3x6 2x4 2x4 2-9-8 2-9-8 -1-0-0 1-0-0 2-9-8 2-9-8 0-8-02-6-58.00 12 Plate Offsets (X,Y)-- [2:0-0-13,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=Mechanical Max Horz 5=68(LC 7) Max Uplift 5=-20(LC 10), 4=-19(LC 10) Max Grav 5=168(LC 1), 4=93(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J23 Truss Type Jack-Open Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589703 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:48 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Ku51GpLdUIlMLHpf85VfGT3w5owZqYZ8yGqvaSzblVX Scale = 1:9.1 1 2 5 4 3 3x6 0-10-6 0-10-6 -1-0-0 1-0-0 0-10-6 0-10-6 0-8-01-2-150-9-111-2-158.00 12 Plate Offsets (X,Y)-- [2:0-0-13,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 4 4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 0-10-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-7-14, 3=Mechanical Max Horz 5=28(LC 10) Max Uplift 5=-21(LC 10), 3=-16(LC 1) Max Grav 5=131(LC 1), 3=10(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss J24 Truss Type Jack-Open Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589704 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:49 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-o5fPU9LFFctDyROrip0uohc5qCGoZ?oIBwZS6uzblVW Scale = 1:9.1 1 2 5 4 3 3x6 -1-0-0 1-0-0 0-10-6 0-10-6 0-8-01-2-150-9-111-2-158.00 12 Plate Offsets (X,Y)-- [2:0-0-13,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 4 4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 0-10-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-7-14, 3=Mechanical Max Horz 5=28(LC 10) Max Uplift 5=-21(LC 10), 3=-16(LC 1) Max Grav 5=131(LC 1), 3=10(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss M01 Truss Type Monopitch Qty 4 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589705 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:50 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-GHDnhVMu0v?4abz1FWX7Lu9DMccwIS2RQZJ?fLzblVV Scale = 1:13.6 1 2 3 5 4 6 2x4 2x4 3x4 2x4 -2-3-0 2-3-0 2-0-0 2-0-0 1-1-82-1-81-10-00-3-82-1-86.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.30 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-5: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=76(LC 9) Max Uplift 5=-63(LC 10), 4=-27(LC 18) Max Grav 5=277(LC 1), 4=33(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -2-3-0 to 0-9-0, Interior(1) 0-9-0 to 1-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss M02 Truss Type Monopitch Qty 8 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589706 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:51 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-lTn9vrNWnD8xClYDpE2Mt6hNU0tn1msbfD2ZBnzblVU Scale = 1:27.0 1 2 3 4 7 6 5 8 9 10 3x12 3x4 3x4 2x4 3x6 2x4 6-3-5 6-3-5 11-11-8 5-8-3 -1-0-0 1-0-0 6-3-5 6-3-5 11-11-8 5-8-3 0-4-04-2-34-3-130-9-44-3-134.00 12 Plate Offsets (X,Y)-- [2:0-1-5,Edge], [4:0-9-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.34 0.37 0.60 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.10 0.01 (loc) 2-7 2-7 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-8, 9=0-1-8 Max Horz 2=114(LC 6) Max Uplift 2=-64(LC 6), 9=-62(LC 10) Max Grav 2=498(LC 1), 9=421(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-812/102, 6-8=-43/318, 4-8=-43/318 BOT CHORD 2-7=-175/722, 6-7=-175/722 WEBS 3-7=0/266, 3-6=-730/194, 4-9=-422/106 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 9. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss M03 Truss Type Monopitch Qty 4 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589707 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:51 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-lTn9vrNWnD8xClYDpE2Mt6hS30yE1vIbfD2ZBnzblVU Scale = 1:13.6 1 2 4 3 2x4 2x4 2x4 2x4 2-0-0 2-0-0 1-1-82-1-81-10-00-3-82-1-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.05 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-8, 3=0-1-8 Max Horz 4=49(LC 7) Max Uplift 4=-3(LC 10), 3=-22(LC 7) Max Grav 4=69(LC 18), 3=65(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss PB01 Truss Type Piggyback Qty 9 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589708 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:52 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-DgLX6BO8YXGopu7QNxZbQJEZZPG1mMAktto6jDzblVT Scale = 1:18.4 2 3 4 6 1 7 8 5 4x6 2x4 2x4 2x4 8-0-0 8-0-0 4-0-0 4-0-0 8-0-0 4-0-0 -0-0-42-7-122-8-00-1-00-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.18 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-0-0. (lb) - Max Horz 1=45(LC 9) Max Uplift All uplift 100 lb or less at joint(s) except 1=-152(LC 17), 5=-134(LC 18), 2=-137(LC 10), 4=-127(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 2=313(LC 17), 4=305(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-3-11 to 3-3-11, Corner(3R) 3-3-11 to 4-8-5, Corner(3E) 4-8-5 to 7-8-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 152 lb uplift at joint 1, 134 lb uplift at joint 5, 137 lb uplift at joint 2 and 127 lb uplift at joint 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss PB02 Truss Type GABLE Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589709 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:54 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-92TIXtPO48WW3CHoUMc3VkJwvDymDFf1LBHDo6zblVR Scale = 1:34.5 2 3 4 5 6 10 9 8 1 11 12 7 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 16-0-0 16-0-0 8-0-0 8-0-0 16-0-0 8-0-0 -0-0-45-3-125-4-00-1-00-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.14 0.10 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 1=-94(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 7, 2, 6, 10, 8 except 1=-112(LC 17) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9 except 10=302(LC 17), 8=301(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-3-11 to 3-3-11, Exterior(2N) 3-3-11 to 5-0-0, Corner(3R) 5-0-0 to 11-0-0, Exterior(2N) 11-0-0 to 12-8-5, Corner(3E) 12-8-5 to 15-8-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2, 6, 10, 8 except (jt=lb) 1=112. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss PB03 Truss Type GABLE Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589710 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:55 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-dF0gkCQ0rSeMgMs?237I2ys4IdIzyjWAZr0mKYzblVQ Scale = 1:28.8 2 3 4 5 6 7 8 12 11 10 1 13 14 9 3x6 3x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 16-0-0 16-0-0 5-0-0 5-0-0 11-0-0 6-0-1 16-0-0 5-0-0 -0-0-43-1-103-4-00-1-00-1-83-0-68.00 12 Plate Offsets (X,Y)-- [4:0-3-0,Edge], [6:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.23 0.10 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 1=-56(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 9, 2, 8, 11, 12, 10 except 1=-120(LC 17) Max Grav All reactions 250 lb or less at joint(s) 1, 9, 12, 10 except 2=293(LC 23), 8=293(LC 24), 11=286(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-3-11 to 3-3-11, Corner(3R) 3-3-11 to 12-8-5, Corner(3E) 12-8-5 to 15-8-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 2, 8, 11, 12, 10 except (jt=lb) 1=120. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T01 Truss Type Roof Special Qty 5 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589711 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:57 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Zd8Q9uRHN3u4wg?NAU9m7NxHGQr_QPwT19WtPRzblVO Scale = 1:42.4 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 10x10 4x8 10x10 10x16 MT18HS 10x16 MT18HS6x16 10x10 10x10 3-2-0 3-2-0 6-0-8 2-10-8 12-0-0 5-11-8 17-11-8 5-11-8 20-10-0 2-10-8 24-0-0 3-2-0 -1-0-0 1-0-0 3-2-0 3-2-0 6-0-8 2-10-8 12-0-0 5-11-8 17-11-8 5-11-8 20-10-0 2-10-8 24-0-0 3-2-0 25-0-0 1-0-0 0-10-124-10-120-10-121-11-04.00 12 4.00 12 Plate Offsets (X,Y)-- [8:0-2-8,Edge], [10:0-1-14,0-0-0], [12:0-7-0,0-3-4], [14:0-7-0,0-3-4], [16:0-1-14,0-0-0], [16:0-2-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.77 0.70 0.95 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.60 -1.13 0.82 (loc) 12-13 12-13 10 l/defl >472 >252 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 89 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud *Except* 7-12,8-11,3-14,2-15: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-13, 4-13 REACTIONS. (size)16=0-3-8, 10=0-3-8 Max Horz 16=-37(LC 11) Max Uplift 16=-102(LC 6), 10=-102(LC 7) Max Grav 16=939(LC 1), 10=939(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-16=-934/184, 2-3=-3302/335, 3-4=-5479/575, 4-5=-2192/259, 5-6=-2192/259, 6-7=-5479/575, 7-8=-3302/335, 8-10=-934/184 BOT CHORD 15-16=-63/251, 14-15=-273/3254, 13-14=-452/4935, 12-13=-452/4935, 11-12=-273/3254, 10-11=-22/251 WEBS 5-13=-14/967, 6-13=-2903/342, 6-12=-47/1247, 7-12=-207/2095, 7-11=-614/94, 8-11=-255/2858, 4-13=-2903/342, 4-14=-47/1247, 3-14=-207/2095, 3-15=-614/94, 2-15=-255/2858 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 15-0-0, Interior(1) 15-0-0 to 22-0-0, Exterior(2E) 22-0-0 to 25-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 16, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 16=102, 10=102. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T02 Truss Type Common Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589712 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:58 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-1qipNESv8N0xXpaajCg?faUXoqIg93odGpFQxtzblVN Scale = 1:42.5 1 2 3 4 5 8 7 6 9 10 11 12 4x6 3x8 MT18HS 3x8 MT18HS2x4 3x8 3x8 4-11-4 4-11-4 9-10-8 4-11-4 -1-0-0 1-0-0 4-11-4 4-11-4 9-10-8 4-11-4 10-10-8 1-0-0 1-6-86-5-121-6-812.00 12 Plate Offsets (X,Y)-- [2:0-4-15,Edge], [4:0-4-15,0-0-0], [6:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.47 0.23 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.07 0.00 (loc) 7 7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 37 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-1-8, 6=0-1-8 Max Horz 8=-144(LC 8) Max Uplift 8=-22(LC 10), 6=-22(LC 11) Max Grav 8=470(LC 18), 6=470(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-373/126, 3-4=-372/126, 2-8=-364/182, 4-6=-364/182 WEBS 3-7=0/252 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 7-10-8, Exterior(2E) 7-10-8 to 10-10-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8, 6. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T03 Truss Type COMMON Qty 5 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589713 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:05:58 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-1qipNESv8N0xXpaajCg?faUXrq6r9?ndGpFQxtzblVN Scale = 1:42.6 1 2 3 4 5 6 7 9 8 10 11 12 13 4x6 5x6 3x8 MT18HS 3x8 2x4 2x4 5x6 11-0-0 11-0-0 22-0-0 11-0-0 -1-0-0 1-0-0 5-7-7 5-7-7 11-0-0 5-4-9 16-4-9 5-4-9 22-0-0 5-7-7 23-0-0 1-0-0 0-6-06-0-00-6-06.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-5], [6:Edge,0-1-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.46 0.98 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.52 0.04 (loc) 6-9 6-9 6 l/defl >999 >501 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 72 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=74(LC 14) Max Uplift 2=-66(LC 10), 6=-66(LC 11) Max Grav 2=865(LC 1), 6=865(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1298/189, 3-4=-986/131, 4-5=-986/131, 5-6=-1298/189 BOT CHORD 2-9=-113/1107, 6-9=-97/1107 WEBS 4-9=0/595, 5-9=-352/162, 3-9=-352/162 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-0-0, Exterior(2R) 8-0-0 to 14-0-0, Interior(1) 14-0-0 to 20-0-0, Exterior(2E) 20-0-0 to 23-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T04 Truss Type PIGGYBACK BASE Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589714 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:00 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-_CqZnwU9f_Gfn7kyrdjTl?ZlSerBdt_vj7kX?mzblVL Scale = 1:77.8 1 2 3 4 5 6 7 8 9 10 11 1213 18 17 16 15 14 27 28 29 30 31 32 33 34 35 36 37 38 39 40 3x6 5x8 5x8 3x6 6x8 3x4 3x8 MT18HS4x6 2x4 3x8 2x4 4x6 2x4 6x8 3x4 3x8 MT18HS 11-0-0 11-0-0 21-9-8 10-9-8 32-7-0 10-9-8 43-7-0 11-0-0 -1-0-0 1-0-0 7-0-0 7-0-0 13-9-8 6-9-8 21-9-8 8-0-0 29-9-8 8-0-0 36-7-0 6-9-8 43-7-0 7-0-0 44-7-0 1-0-0 0-8-09-10-50-8-09-10-58.00 12 Plate Offsets (X,Y)-- [6:0-4-8,0-1-12], [8:0-4-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.97 0.74 0.42 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.38 -0.62 0.11 (loc) 14-16 14-16 12 l/defl >999 >846 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 173 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-16,8-16: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-6-0, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (2-2-0 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-16 REACTIONS. (size)2=0-3-8, 12=0-3-8 Max Horz 2=-182(LC 8) Max Uplift 2=-58(LC 10), 12=-58(LC 11) Max Grav 2=1902(LC 2), 12=1902(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2716/90, 4-6=-2548/111, 6-7=-2217/138, 7-8=-2217/138, 8-10=-2548/111, 10-12=-2716/90 BOT CHORD 2-18=-101/2208, 16-18=-68/1858, 14-16=0/1858, 12-14=0/2201 WEBS 4-18=-329/203, 6-18=-30/738, 6-16=-122/653, 7-16=-494/191, 8-16=-122/653, 8-14=-30/738, 10-14=-329/204 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-6-9, Exterior(2R) 9-6-9 to 18-0-7, Interior(1) 18-0-7 to 25-6-9, Exterior(2R) 25-6-9 to 34-0-7, Interior(1) 34-0-7 to 41-7-0, Exterior(2E) 41-7-0 to 44-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T05 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589715 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:02 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-wbyJCcVPBbWN0RuLy1lxqQf6BRUR5fNCARDe4ezblVJ Scale = 1:83.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 24 23 22 21 20 19 18 17 16 15 33 34 35 36 37 38 39 3x6 6x6 4x6 2x4 2x4 3x8 MT18HS 5x12 2x4 2x4 3x8 MT18HS 5x8 4x8 6x8 3x6 3x6 6x6 3x4 6x10 3x4 2x4 6x8 3x4 1-0-0 1-0-0 2-2-0 1-2-0 9-9-8 7-7-8 18-6-0 8-8-8 26-1-12 7-7-12 33-9-8 7-7-12 43-7-0 9-9-8 -1-0-0 1-0-0 1-0-0 1-0-0 2-2-0 1-2-0 5-11-12 3-9-12 9-9-8 3-9-12 18-6-0 8-8-8 26-1-12 7-7-12 33-9-8 7-7-12 38-7-0 4-9-8 43-7-0 5-0-0 44-7-0 1-0-0 0-8-07-0-37-2-50-8-07-0-38.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-1], [19:0-5-4,0-3-0], [21:0-2-8,0-1-8], [22:0-2-12,Edge], [24:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.95 0.94 0.94 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.41 -0.75 0.22 (loc) 19-21 19-21 13 l/defl >999 >700 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 180 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 8-10,6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 20-22,13-16: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-19: 2x4 SPF No.2 SLIDER Left 2x3 SPF No.2 1-1-1, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-7-3 oc purlins, except 2-0-0 oc purlins (2-2-0 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 19-21. REACTIONS. (size)2=0-3-8, 13=0-3-8 Max Horz 2=-131(LC 8) Max Uplift 2=-35(LC 7), 13=-34(LC 6) Max Grav 2=1810(LC 2), 13=1814(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1086/27, 3-4=-3743/169, 4-5=-3798/210, 5-6=-2763/138, 6-7=-3153/214, 7-9=-3150/215, 9-10=-2813/176, 10-11=-2468/121, 11-13=-2600/113 BOT CHORD 2-24=-135/1606, 21-22=-182/2502, 19-21=-143/2278, 15-17=-23/2035, 13-15=-41/2103 WEBS 7-19=-497/182, 3-24=-1077/89, 22-24=-154/1804, 3-22=-109/1511, 5-22=-107/937, 5-21=-358/140, 6-21=0/655, 6-19=-202/1124, 17-19=-150/2729, 9-19=-97/456, 9-17=-721/222, 10-17=-166/1094, 10-15=0/419 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 1-11-12, Interior(1) 1-11-12 to 5-6-9, Exterior(2R) 5-6-9 to 14-0-6, Interior(1) 14-0-6 to 29-6-10, Exterior(2R) 29-6-10 to 38-0-7, Interior(1) 38-0-7 to 41-7-0, Exterior(2E) 41-7-0 to 44-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 13. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T06 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589716 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:04 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-sz34dHXgjDm5Gl2j4SnPvrkThF92ZcmVelil8XzblVH Scale = 1:84.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 27 26 25 24 23 22 21 20 19 18 17 36 37 38 39 40 41 42 43 3x6 6x6 3x6 3x6 4x6 2x4 2x4 3x6 5x12 2x4 2x4 3x6 5x8 4x8 6x8 3x6 4x6 3x4 5x12 6x6 3x4 3x6 2x4 5x8 3x4 1-0-0 1-0-0 2-2-0 1-2-0 10-4-0 8-2-0 18-6-0 8-2-0 24-7-12 6-1-12 30-9-8 6-1-12 37-1-0 6-3-8 43-7-0 6-6-0 -1-0-0 1-0-0 1-0-0 1-0-0 2-2-0 1-2-0 7-5-12 5-3-12 12-9-8 5-3-12 18-6-0 5-8-8 24-7-12 6-1-12 30-9-8 6-1-12 37-1-0 6-3-8 43-7-0 6-6-0 44-7-0 1-0-0 0-8-09-0-39-2-50-8-09-0-38.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-1], [5:0-2-8,0-1-8], [15:0-3-13,Edge], [22:0-4-4,0-2-8], [25:0-2-12,Edge], [27:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.89 1.00 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.39 -0.64 0.23 (loc) 22-24 22-24 15 l/defl >999 >813 n/a L/d 240 180 n/a PLATES MT20 Weight: 193 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 23-25: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 11-20: 2x4 SPF No.2 SLIDER Left 2x3 SPF No.2 1-1-1, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except 2-0-0 oc purlins (3-5-10 max.): 7-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 15-17. WEBS 1 Row at midpt 8-21, 10-20 REACTIONS. (size)2=0-3-8, 15=0-3-8 Max Horz 2=167(LC 9) Max Uplift 2=-53(LC 10), 15=-52(LC 11) Max Grav 2=1821(LC 2), 15=1819(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1099/30, 3-4=-3792/159, 4-5=-3873/245, 5-7=-2714/107, 7-8=-2385/130, 8-10=-2384/130, 10-11=-2230/129, 11-13=-2314/116, 13-15=-2636/63 BOT CHORD 2-27=-114/1648, 24-25=-124/2402, 22-24=-93/2002, 18-20=0/1870, 17-18=0/2123, 15-17=0/2123 WEBS 8-22=-360/131, 3-27=-1082/68, 25-27=-132/1854, 3-25=-127/1574, 5-25=-180/1153, 5-24=-423/191, 7-24=-38/797, 7-22=-134/735, 20-22=-55/2190, 10-22=-76/295, 10-20=-605/199, 11-20=-132/704, 11-18=-15/511, 13-18=-403/149 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 1-11-12, Interior(1) 1-11-12 to 8-6-9, Exterior(2R) 8-6-9 to 17-0-6, Interior(1) 17-0-6 to 26-6-10, Exterior(2R) 26-6-10 to 35-0-7, Interior(1) 35-0-7 to 41-7-0, Exterior(2E) 41-7-0 to 44-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 15. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T07 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589717 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:06 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-oMBq2zYwFq0pV2B6Btpt_GppO3tl1Wto53BrDPzblVF Scale = 1:89.7 12 3 4 5 6 7 8 9 10 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 35 36 37 38 39 44 40 41 42 43 3x6 6x6 6x6 3x6 4x6 2x4 3x6 3x6 5x12 2x4 2x4 3x6 6x10 4x8 6x10 4x8 2x4 3x4 5x12 3x6 3x6 2x4 5x12 3x4 1-0-0 1-0-0 2-2-0 1-2-0 10-4-0 8-2-0 18-6-0 8-2-0 23-1-12 4-7-12 27-9-8 4-7-12 35-7-0 7-9-8 43-7-0 8-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 2-2-0 1-2-0 10-4-0 8-2-0 15-9-8 5-5-8 18-6-0 2-8-8 23-1-12 4-7-12 27-9-8 4-7-12 35-7-0 7-9-8 43-7-0 8-0-0 44-7-0 1-0-0 0-8-011-0-311-2-50-8-011-0-38.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-1], [14:0-0-0,0-1-13], [21:0-4-0,0-2-8], [24:0-6-4,0-3-0], [26:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.88 0.85 0.71 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.38 -0.61 0.22 (loc) 21-23 21-23 14 l/defl >999 >859 n/a L/d 240 180 n/a PLATES MT20 Weight: 230 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7,10-11: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 22-24,14-17: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 4-25,3-26,24-26,3-24,6-23,19-21,12-18,12-16: 2x3 SPF No.2 SLIDER Left 2x3 SPF No.2 1-1-1, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (4-1-5 max.): 7-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-20, 4-23, 9-21, 9-19, 12-18 REACTIONS. (size)2=0-3-8, 14=0-3-8 Max Horz 2=204(LC 9) Max Uplift 2=-72(LC 10), 14=-72(LC 11) Max Grav 2=1844(LC 2), 14=1882(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1174/70, 3-4=-4276/297, 4-6=-2825/87, 6-7=-2793/248, 7-8=-1943/163, 8-9=-1940/163, 9-10=-1868/166, 10-12=-2189/142, 12-14=-2719/90 BOT CHORD 2-26=-123/1686, 23-24=-440/3940, 21-23=-26/1805, 18-19=0/1739, 16-18=0/2189, 14-16=0/2189 WEBS 4-24=0/628, 3-26=-1204/59, 24-26=-143/2002, 3-24=-323/2206, 4-23=-1640/383, 6-23=-402/252, 19-21=0/1813, 9-19=-506/178, 10-19=-132/441, 10-18=-27/654, 12-18=-652/180, 12-16=0/387, 7-23=-195/1112, 7-21=-108/613 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-12, Interior(1) 2-0-12 to 11-6-9, Exterior(2R) 11-6-9 to 20-0-6, Interior(1) 20-0-6 to 23-6-10, Exterior(2R) 23-6-10 to 32-0-7, Interior(1) 32-0-7 to 41-7-0, Exterior(2E) 41-7-0 to 44-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T08 Truss Type PIGGYBACK BASE Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589718 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:07 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-HYlCFJZY089f7CmIlbL6XUM_CSA6m_TxKjxPlszblVE Scale = 1:83.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 25 24 23 22 21 20 19 18 17 16 34 35 36 37 38 39 40 41 3x6 5x6 5x8 3x6 4x6 2x4 2x4 3x6 2x4 2x4 5x8 5x8 4x8 6x8 3x6 4x6 5x8 3x4 5x12 3x6 2x4 5x8 3x4 1-0-0 1-0-0 2-2-0 1-2-0 10-4-0 8-2-0 18-6-0 8-2-0 24-1-12 5-7-12 29-9-8 5-7-12 36-7-0 6-9-8 43-7-0 7-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 2-2-0 1-2-0 7-11-12 5-9-12 13-9-8 5-9-12 18-6-0 4-8-8 24-1-12 5-7-12 29-9-8 5-7-12 36-7-0 6-9-8 43-7-0 7-0-0 44-7-0 1-0-0 0-8-09-10-50-8-09-10-58.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-1], [7:0-3-8,0-1-12], [10:0-5-12,0-2-0], [14:0-3-13,Edge], [17:0-3-12,0-3-0], [20:0-2-8,0-3-0], [23:0-2-12,Edge], [25:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.87 0.97 0.69 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.39 -0.64 0.22 (loc) 20-22 20-22 14 l/defl >999 >813 n/a L/d 240 180 n/a PLATES MT20 Weight: 202 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 21-23: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 9-20,10-18: 2x4 SPF No.2 SLIDER Left 2x3 SPF No.2 1-1-1, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (3-10-1 max.): 7-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 2-2-0 oc bracing: 14-16. WEBS 1 Row at midpt 8-19, 9-18, 12-17 REACTIONS. (size)2=0-3-8, 14=0-3-8 Max Horz 2=-182(LC 8) Max Uplift 2=-60(LC 10), 14=-59(LC 11) Max Grav 2=1824(LC 2), 14=1817(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1101/36, 3-4=-3799/187, 4-5=-3882/283, 5-7=-2734/129, 7-8=-2160/142, 8-9=-2160/143, 9-10=-2041/143, 10-12=-2235/126, 12-14=-2636/69 BOT CHORD 2-25=-119/1676, 22-23=-103/2385, 20-22=-74/1899, 17-18=0/1796, 16-17=0/2124, 14-16=0/2124 WEBS 8-20=-294/115, 3-25=-1098/72, 23-25=-136/1885, 3-23=-152/1607, 5-23=-209/1197, 5-22=-490/212, 7-22=-70/907, 7-20=-123/640, 18-20=-31/2013, 9-20=-73/267, 9-18=-550/192, 10-18=-134/573, 10-17=-16/561, 12-17=-512/161, 12-16=0/251 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 1-11-12, Interior(1) 1-11-12 to 9-6-9, Exterior(2R) 9-6-9 to 18-0-7, Interior(1) 18-0-7 to 25-6-9, Exterior(2R) 25-6-9 to 34-0-7, Interior(1) 34-0-7 to 41-7-0, Exterior(2E) 41-7-0 to 44-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T09 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589719 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:09 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-Dxtzg?boYlPNMWwht0NacvRNhGtgEsIEn1QWqkzblVC Scale = 1:71.6 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 25 26 27 28 29 30 31 32 6x6 3x8 6x8 3x4 6x8 3x4 3x6 3x4 2x4 3x8 2x4 6x6 3x4 2x4 3x6 10-9-7 10-9-7 19-9-8 9-0-1 28-9-9 9-0-1 39-7-0 10-9-7 -1-0-0 1-0-0 5-6-8 5-6-8 10-9-7 5-3-0 19-9-8 9-0-1 28-9-9 9-0-1 34-0-8 5-3-0 39-7-0 5-6-8 0-8-07-8-37-10-50-8-07-8-38.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.62 0.90 0.80 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.42 0.10 (loc) 14-16 14-16 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 153 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7,7-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-15: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-14,8-14: 2x4 SPF No.2 SLIDER Left 2x3 SPF No.2 1-6-0, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-6 oc purlins, except 2-0-0 oc purlins (4-4-9 max.): 5-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)11=0-3-8, 2=0-3-8 Max Horz 2=139(LC 9) Max Uplift 11=-26(LC 11), 2=-42(LC 10) Max Grav 11=1630(LC 2), 2=1675(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2359/101, 4-5=-2206/96, 5-6=-2299/125, 6-8=-2297/125, 8-9=-2209/100, 9-11=-2362/106 BOT CHORD 2-16=-127/1909, 14-16=-86/1794, 12-14=0/1796, 11-12=-34/1913 WEBS 5-16=0/524, 5-14=-155/723, 6-14=-590/216, 8-14=-155/722, 8-12=0/528 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-6-9, Exterior(2R) 6-6-9 to 15-0-6, Interior(1) 15-0-6 to 24-6-10, Exterior(2R) 24-6-10 to 33-0-7, Interior(1) 33-0-7 to 36-7-0, Exterior(2E) 36-7-0 to 39-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T10 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589720 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:10 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-h7QLuLcQJ3XE_gVtQjup96_ZugIUzQzO0h93MAzblVB Scale = 1:71.4 1 2 3 4 5 6 7 8 9 10 11 12 17 16 15 14 13 26 27 28 29 30 31 32 33 34 35 36 37 38 39 3x6 6x6 6x6 3x6 3x6 6x8 3x4 4x6 2x4 3x8 2x4 4x6 2x4 6x8 3x4 3x6 10-0-8 10-0-8 19-9-8 9-9-0 29-6-8 9-9-0 39-7-0 10-0-8 -1-0-0 1-0-0 7-0-8 7-0-8 13-9-7 6-9-0 19-9-8 6-0-1 25-9-9 6-0-1 32-6-8 6-9-0 39-7-0 7-0-8 0-8-09-8-39-10-50-8-09-8-38.00 12 Plate Offsets (X,Y)-- [9:0-0-0,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.52 0.61 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.44 0.09 (loc) 15-17 15-17 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 158 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-15,8-15: 2x4 SPF No.2 SLIDER Left 2x3 SPF No.2 1-6-0, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-2 oc purlins, except 2-0-0 oc purlins (4-0-7 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-15 REACTIONS. (size)12=Mechanical, 2=0-3-8 Max Horz 2=175(LC 9) Max Uplift 12=-46(LC 11), 2=-63(LC 10) Max Grav 12=1686(LC 2), 2=1731(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2438/98, 4-6=-2301/133, 6-7=-1862/154, 7-8=-1862/154, 8-10=-2304/137, 10-12=-2441/102 BOT CHORD 2-17=-109/2002, 15-17=-40/1620, 13-15=0/1621, 12-13=-23/1969 WEBS 4-17=-295/203, 6-17=-62/712, 6-15=-97/540, 7-15=-393/143, 8-15=-97/539, 8-13=-64/716, 10-13=-297/203 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-6-9, Exterior(2R) 9-6-9 to 18-0-6, Interior(1) 18-0-6 to 21-6-10, Exterior(2R) 21-6-10 to 30-0-7, Interior(1) 30-0-7 to 36-7-0, Exterior(2E) 36-7-0 to 39-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T11 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589721 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:12 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-dWY5J0dhrgnyDzfGY8wHEX3tMTwsRJGgU?eAR3zblV9 Scale = 1:80.8 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 25 26 27 28 29 30 31 32 33 34 3x6 6x6 6x6 3x6 3x8 MT18HS 5x8 3x4 2x4 3x6 3x4 3x6 2x4 5x8 3x4 3x8 MT18HS 8-6-8 8-6-8 19-9-8 11-3-0 31-0-8 11-3-0 39-7-0 8-6-8 -1-0-0 1-0-0 8-6-8 8-6-8 16-9-7 8-3-0 22-9-9 6-0-1 31-0-8 8-3-0 39-7-0 8-6-8 0-8-011-8-311-10-50-8-011-8-38.00 12 Plate Offsets (X,Y)-- [8:0-0-0,0-0-0], [12:0-2-8,0-1-8], [16:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.65 0.87 0.40 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.45 -0.71 0.09 (loc) 12-14 14-16 11 l/defl >999 >665 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 170 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 6-7: 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 4-16,9-12: 2x3 SPF No.2 SLIDER Left 2x3 SPF No.2 1-6-0, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-2 oc purlins, except 2-0-0 oc purlins (4-5-1 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-16, 6-14, 7-14, 7-12 REACTIONS. (size)11=Mechanical, 2=0-3-8 Max Horz 2=212(LC 9) Max Uplift 11=-62(LC 11), 2=-79(LC 10) Max Grav 11=1737(LC 18), 2=1786(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2540/95, 4-6=-2585/302, 6-7=-1570/152, 7-9=-2589/304, 9-11=-2543/96 BOT CHORD 2-16=-123/2154, 14-16=0/1530, 12-14=0/1496, 11-12=0/2039 WEBS 4-16=-444/306, 6-16=-247/1068, 6-14=-34/413, 7-14=-35/412, 7-12=-248/1073, 9-12=-447/307 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-6-9, Exterior(2R) 12-6-9 to 27-0-7, Interior(1) 27-0-7 to 36-7-0, Exterior(2E) 36-7-0 to 39-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T12 Truss Type PIGGYBACK BASE Qty 4 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589722 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:13 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-5i6TWMeJb_vpr7ES6rSWmlc4otJ7An2qifOjzVzblV8 Scale = 1:77.2 1 2 3 4 5 6 7 8 9 10 11 12 17 16 15 14 13 26 27 28 29 30 31 32 33 34 35 3x6 6x10 6x10 3x6 5x12 3x4 3x6 3x6 2x4 3x4 3x6 2x4 5x12 3x4 3x6 10-0-8 10-0-8 19-9-8 9-9-0 29-6-8 9-9-0 39-7-0 10-0-8 -1-0-0 1-0-0 8-0-8 8-0-8 15-9-8 7-9-0 23-9-8 8-0-0 31-6-8 7-9-0 39-7-0 8-0-8 40-7-0 1-0-0 0-8-011-2-50-8-011-2-58.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-13], [6:0-5-12,0-1-4], [7:0-5-12,0-1-4], [11:Edge,0-1-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.55 0.61 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.41 0.08 (loc) 13-15 13-15 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 166 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 4-17,9-13: 2x3 SPF No.2 SLIDER Left 2x3 SPF No.2 1-6-0, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-4 oc purlins, except 2-0-0 oc purlins (5-3-15 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15, 7-15 REACTIONS. (size)2=0-3-8, 11=0-3-8 Max Horz 2=-206(LC 8) Max Uplift 2=-73(LC 10), 11=-73(LC 11) Max Grav 2=1756(LC 17), 11=1756(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2468/103, 4-6=-2369/198, 6-7=-1600/159, 7-9=-2369/198, 9-11=-2468/103 BOT CHORD 2-17=-120/2086, 15-17=0/1535, 13-15=0/1517, 11-13=0/1987 WEBS 4-17=-394/246, 6-17=-135/895, 6-15=-36/349, 7-15=-36/349, 7-13=-135/895, 9-13=-394/246 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-6-9, Exterior(2R) 11-6-9 to 28-0-7, Interior(1) 28-0-7 to 37-7-0, Exterior(2E) 37-7-0 to 40-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T13 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589723 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:14 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-ZvgskifxMH1gSHpefZzlJy8ESHaqv7YzxI7HVyzblV7 Scale = 1:71.8 1 2 3 4 5 6 7 8 9 10 11 12 17 16 15 14 13 26 27 28 29 30 31 32 33 6x6 3x8 6x8 3x4 3x6 3x4 2x4 3x8 2x4 6x6 3x4 2x4 6x8 3x4 3x6 10-9-8 10-9-8 19-9-8 9-0-0 28-9-9 9-0-0 39-7-0 10-9-8 -1-0-0 1-0-0 5-6-8 5-6-8 10-9-8 5-3-0 19-9-8 9-0-0 28-9-9 9-0-0 34-0-8 5-3-0 39-7-0 5-6-8 40-7-0 1-0-0 0-8-07-8-37-10-50-8-07-8-38.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.62 0.90 0.80 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.42 0.10 (loc) 15-17 15-17 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 155 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7,7-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E *Except* 14-16: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-15,8-15: 2x4 SPF No.2 SLIDER Left 2x3 SPF No.2 1-6-0, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-7 oc purlins, except 2-0-0 oc purlins (4-4-10 max.): 5-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 11=0-3-8 Max Horz 2=-143(LC 8) Max Uplift 2=-42(LC 10), 11=-42(LC 11) Max Grav 2=1674(LC 2), 11=1674(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2358/99, 4-5=-2205/95, 5-6=-2297/122, 6-8=-2296/122, 8-9=-2205/95, 9-11=-2358/99 BOT CHORD 2-17=-122/1909, 15-17=-81/1794, 13-15=0/1794, 11-13=-5/1908 WEBS 5-17=0/524, 5-15=-155/722, 6-15=-590/216, 8-15=-155/722, 8-13=0/524 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-6-9, Exterior(2R) 6-6-9 to 15-0-6, Interior(1) 15-0-6 to 24-6-10, Exterior(2R) 24-6-10 to 33-0-7, Interior(1) 33-0-7 to 37-7-0, Exterior(2E) 37-7-0 to 40-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T14 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589724 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:16 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-WHoc8OgBuvHOiby1n_?DONEbO5LuN8SGPccNaqzblV5 Scale = 1:71.8 1 2 3 4 5 6 7 8 9 10 11 12 13 18 17 16 15 14 27 28 29 30 31 32 33 34 35 36 37 38 39 40 3x6 6x6 6x6 3x6 3x6 6x8 3x4 4x6 2x4 3x8 2x4 4x6 2x4 6x8 3x4 3x6 10-0-8 10-0-8 19-9-8 9-9-0 29-6-8 9-9-0 39-7-0 10-0-8 -1-0-0 1-0-0 7-0-8 7-0-8 13-9-8 6-9-0 19-9-8 6-0-1 25-9-9 6-0-1 32-6-8 6-9-0 39-7-0 7-0-8 40-7-0 1-0-0 0-8-09-8-39-10-50-8-09-8-38.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.52 0.61 0.32 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.27 -0.44 0.09 (loc) 16-18 16-18 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 160 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-16,8-16: 2x4 SPF No.2 SLIDER Left 2x3 SPF No.2 1-6-0, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-3 oc purlins, except 2-0-0 oc purlins (4-0-7 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-16 REACTIONS. (size)12=0-3-8, 2=0-3-8 Max Horz 2=-180(LC 8) Max Uplift 12=-63(LC 11), 2=-63(LC 10) Max Grav 12=1730(LC 2), 2=1730(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2437/96, 4-6=-2300/131, 6-7=-1861/152, 7-8=-1861/152, 8-10=-2300/131, 10-12=-2437/96 BOT CHORD 2-18=-101/2008, 16-18=-35/1619, 14-16=0/1619, 12-14=0/1965 WEBS 4-18=-295/203, 6-18=-62/712, 6-16=-97/540, 7-16=-393/143, 8-16=-97/540, 10-14=-295/203, 8-14=-62/712 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 9-6-9, Exterior(2R) 9-6-9 to 18-0-6, Interior(1) 18-0-6 to 21-6-10, Exterior(2R) 21-6-10 to 30-0-7, Interior(1) 30-0-7 to 37-7-0, Exterior(2E) 37-7-0 to 40-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T15 Truss Type HIP Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589725 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:17 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-_TM_MkhpfCPFJkXDLhWSxbmk5Ud16aXQdGMx6GzblV4 Scale = 1:81.5 1 2 3 4 5 6 7 8 9 10 1112 17 16 15 14 13 26 27 28 29 30 31 32 33 34 35 3x6 6x6 6x6 3x6 3x8 MT18HS 5x8 3x4 2x4 3x6 3x4 3x6 2x4 5x8 3x4 3x8 MT18HS 8-6-8 8-6-8 19-9-8 11-3-0 31-0-8 11-3-0 39-7-0 8-6-8 -1-0-0 1-0-0 8-6-8 8-6-8 16-9-8 8-3-0 22-9-9 6-0-1 31-0-8 8-3-0 39-7-0 8-6-8 40-7-0 1-0-0 0-8-011-8-311-10-50-8-011-8-38.00 12 Plate Offsets (X,Y)-- [13:0-2-8,0-1-8], [17:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.65 0.87 0.40 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.45 -0.71 0.09 (loc) 13-15 13-15 11 l/defl >999 >665 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 171 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 6-7: 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 4-17,9-13: 2x3 SPF No.2 SLIDER Left 2x3 SPF No.2 1-6-0, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-2 oc purlins, except 2-0-0 oc purlins (4-5-2 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-17, 6-15, 7-15, 7-13 REACTIONS. (size)11=0-3-8, 2=0-3-8 Max Horz 2=-216(LC 8) Max Uplift 11=-79(LC 11), 2=-79(LC 10) Max Grav 11=1786(LC 18), 2=1786(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2539/95, 4-6=-2584/302, 6-7=-1570/150, 7-9=-2584/302, 9-11=-2539/95 BOT CHORD 2-17=-115/2160, 15-17=0/1535, 13-15=0/1495, 11-13=0/2035 WEBS 4-17=-444/306, 6-17=-247/1068, 6-15=-34/413, 7-15=-34/413, 7-13=-247/1068, 9-13=-444/306 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-6-9, Exterior(2R) 12-6-9 to 27-0-7, Interior(1) 27-0-7 to 37-7-0, Exterior(2E) 37-7-0 to 40-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss T17 Truss Type PIGGYBACK BASE Qty 5 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589726 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:19 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-wsTlnQj4BqfzZ2hcS6Yw00s?NIMXaUXi5ar2A9zblV2 Scale = 1:72.6 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 25 26 27 28 29 30 31 32 33 34 3x6 6x10 6x10 3x6 3x6 5x8 3x4 3x6 2x4 3x4 5x12 3x4 3x6 2x4 3x6 10-0-8 10-0-8 15-9-8 5-9-0 19-9-8 4-0-0 23-9-8 4-0-0 29-6-8 5-9-0 39-7-0 10-0-8 -1-0-0 1-0-0 8-0-8 8-0-8 15-9-8 7-9-0 23-9-8 8-0-0 31-6-8 7-9-0 39-7-0 8-0-8 0-8-011-2-50-8-011-2-58.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-13], [6:0-5-12,0-1-4], [7:0-5-12,0-1-4], [11:0-0-0,0-2-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.99 0.61 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.41 0.08 (loc) 12-14 12-14 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 8-11: 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 4-16,9-12: 2x3 SPF No.2 SLIDER Left 2x3 SPF No.2 1-6-0, Right 2x3 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (5-3-15 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-14, 7-14 REACTIONS. (size)11=Mechanical, 2=0-3-8 Max Horz 2=202(LC 9) Max Uplift 11=-57(LC 11), 2=-74(LC 10) Max Grav 11=1710(LC 2), 2=1756(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2469/103, 4-6=-2370/198, 6-7=-1601/161, 7-9=-2372/198, 9-11=-2470/104 BOT CHORD 2-16=-128/2081, 14-16=0/1529, 12-14=0/1518, 11-12=-11/1989 WEBS 4-16=-394/246, 6-16=-135/895, 6-14=-36/349, 7-14=-37/348, 7-12=-135/896, 9-12=-392/244 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 11-6-9, Exterior(2R) 11-6-9 to 28-0-7, Interior(1) 28-0-7 to 36-7-0, Exterior(2E) 36-7-0 to 39-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss TG01 Truss Type HIP GIRDER Qty 1 Ply 2 FISCHER OBF-104 Job Reference (optional) I40589727 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:21 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-sFbVC5kKjRvgoMr_aXbO5RxNz5yB2Gt?YuK8F2zblV0 Scale = 1:82.7 1 2 3 4 5 6 7 8 9 10 11 12 1314 26 25 24 23 22 21 20 19 18 17 16 15353637383940 41 42 43 44 45 46 47 48 5x8 3x6 3x8 2x4 3x6 3x8 MT18HS 5x12 2x4 2x4 3x8 MT18HS 5x8 4x6 5x8 5x8 4x8 2x4 3x4 6x10 2x4 4x6 4x8 5x8 3x4 5x6 1-0-0 1-0-0 2-2-0 1-2-0 6-9-8 4-7-8 12-7-12 5-10-4 18-6-0 5-10-4 24-6-12 6-0-12 30-8-12 6-2-0 36-9-8 6-0-12 43-7-0 6-9-8 -1-0-0 1-0-0 1-0-0 1-0-0 2-2-0 1-2-0 6-9-8 4-7-8 12-7-12 5-10-4 18-6-0 5-10-4 24-6-12 6-0-12 30-8-12 6-2-0 36-9-8 6-0-12 43-7-0 6-9-8 44-7-0 1-0-0 0-8-05-1-45-2-50-8-05-1-48.00 12 Plate Offsets (X,Y)-- [5:0-4-0,0-1-9], [11:0-3-0,0-2-3], [13:0-3-13,Edge], [15:0-2-8,0-2-0], [20:0-5-12,0-3-0], [24:0-5-8,0-3-0], [26:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.85 0.99 0.89 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.45 -0.73 0.24 (loc) 18-19 18-19 13 l/defl >999 >717 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 344 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 20-22,13-17: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 18-20: 2x4 SPF No.2 SLIDER Left 2x3 SPF No.2 1-1-1, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-11 oc purlins, except 2-0-0 oc purlins (4-2-12 max.): 5-11. BOT CHORD Rigid ceiling directly applied or 8-6-9 oc bracing. REACTIONS. (size)2=0-3-8, 13=0-3-8 Max Horz 2=95(LC 7) Max Uplift 2=-869(LC 5), 13=-870(LC 4) Max Grav 2=2885(LC 1), 13=2885(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2173/684, 3-4=-6583/2145, 4-5=-4909/1661, 5-6=-4066/1408, 6-7=-7466/2642, 7-9=-7445/2635, 9-10=-6524/2305, 10-11=-3438/1186, 11-13=-4283/1426 BOT CHORD 2-26=-857/2510, 23-24=-1899/5644, 21-23=-2253/6363, 20-21=-2253/6363, 16-18=-1910/5533, 15-16=-1910/5533, 13-15=-1120/3482 WEBS 4-24=-359/1121, 7-20=-313/120, 3-26=-2081/716, 24-26=-1025/2997, 3-24=-1005/3029, 4-23=-1608/539, 5-23=-825/2371, 6-23=-2857/1086, 6-21=-189/579, 6-20=-530/1385, 18-20=-2245/6382, 9-20=-413/1114, 9-18=-953/353, 10-18=-487/1291, 10-16=-193/561, 10-15=-2718/1045, 11-15=-737/2064 NOTES-(13-14) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=869, 13=870. Continued on page 2 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss TG01 Truss Type HIP GIRDER Qty 1 Ply 2 FISCHER OBF-104 Job Reference (optional) I40589727 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:21 2020 Page 2 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-sFbVC5kKjRvgoMr_aXbO5RxNz5yB2Gt?YuK8F2zblV0 NOTES-(13-14) 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 160 lb down and 77 lb up at 2-10-4, 118 lb down and 65 lb up at 4-10-4, 138 lb down and 90 lb up at 6-10-4, 138 lb down and 90 lb up at 8-10-4, 138 lb down and 90 lb up at 10-10-4, 138 lb down and 90 lb up at 12-10-4, 138 lb down and 90 lb up at 14-10-4, 138 lb down and 90 lb up at 16-10-4, 138 lb down and 90 lb up at 18-7-4, 138 lb down and 90 lb up at 20-10-4, 138 lb down and 90 lb up at 22-8-13, 138 lb down and 90 lb up at 24-8-13, 138 lb down and 90 lb up at 26-8-13, 138 lb down and 90 lb up at 28-8-13, 138 lb down and 90 lb up at 30-8-13, 138 lb down and 90 lb up at 32-8-13, 138 lb down and 90 lb up at 34-8-13, 138 lb down and 90 lb up at 36-8-13, and 118 lb down and 66 lb up at 38-8-12, and 163 lb down and 78 lb up at 40-8-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-54, 5-11=-54, 11-14=-54, 25-27=-20, 20-24=-20, 19-31=-20 Concentrated Loads (lb) Vert: 20=-118 23=-118 21=-118 18=-118 16=-118 15=-118 35=-160 36=-118 37=-118 38=-118 39=-118 40=-118 41=-118 42=-118 43=-118 44=-118 45=-118 46=-118 47=-118 48=-163 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 FISCHER OBF-104 Job Reference (optional) I40589728 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:23 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-pdjFcnmaF2AO1f?NhydsAs0njvnkWA4I0CpFJwzblV_ Scale = 1:50.9 1 2 3 5 467891011 12 13 5x12 5x12 5x12 5x8 5x8 5-0-11 5-0-11 9-11-5 4-10-10 15-0-0 5-0-11 7-6-0 7-6-0 15-0-0 7-6-0 1-1-08-7-01-1-012.00 12 Plate Offsets (X,Y)-- [1:0-1-0,0-1-0], [1:0-2-0,0-5-11], [3:0-1-0,0-1-0], [3:0-2-0,0-5-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.58 0.40 0.84 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.13 0.02 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 200 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x3 SPF No.2 WEDGE Left: 2x6 SPF No.2, Right: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-3-8 Max Horz 1=146(LC 28) Max Uplift 1=-246(LC 9), 3=-271(LC 8) Max Grav 1=6205(LC 2), 3=6688(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-6568/323, 2-3=-6627/326 BOT CHORD 1-5=-168/4419, 4-5=-116/2973, 3-4=-143/4462 WEBS 2-4=-205/4901, 2-5=-199/4761 NOTES-(10-11) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=246, 3=271. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1651 lb down and 66 lb up at 1-9-1, 1689 lb down and 82 lb up at 3-9-1, 1671 lb down and 77 lb up at 5-9-1, 1660 lb down and 77 lb up at 7-9-1, 1675 lb down and 77 lb up at 9-9-1, and 1675 lb down and 77 lb up at 11-9-1, and 1675 lb down and 77 lb up at 13-9-1 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).Continued on page 2 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 FISCHER OBF-104 Job Reference (optional) I40589728 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:23 2020 Page 2 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-pdjFcnmaF2AO1f?NhydsAs0njvnkWA4I0CpFJwzblV_ LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 1-3=-20 Concentrated Loads (lb) Vert: 4=-1444(B) 6=-1444(B) 7=-1444(B) 8=-1444(B) 10=-1444(B) 12=-1444(B) 13=-1444(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss TG03 Truss Type Hip Girder Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589729 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:24 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-HqHeq7mC0MIFfpZZFf85j3ZvnJ6aFfkSEsYorNzblUz Scale = 1:70.4 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10161718192021222324 25 26 5x12 4x8 5x12 4x8 5x10 MT18HS3x8 6x6 4x6 2x4 6x10 3x8 5x10 MT18HS 4x8 7-9-7 7-9-7 15-10-1 8-0-10 23-8-15 7-10-14 31-9-9 8-0-10 39-7-0 7-9-7 -1-0-0 1-0-0 7-9-7 7-9-7 15-10-1 8-0-10 23-8-15 7-10-14 31-9-9 8-0-10 39-7-0 7-9-7 40-7-0 1-0-0 0-8-05-9-45-10-50-8-05-9-48.00 12 Plate Offsets (X,Y)-- [2:0-1-5,0-2-0], [3:0-7-4,0-2-12], [4:0-2-8,0-2-0], [7:0-7-4,0-2-12], [8:0-1-5,0-2-0], [13:0-2-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.75 0.49 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.28 -0.49 0.11 (loc) 12-13 12-13 8 l/defl >999 >965 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 219 lb FT = 20% GRIP 197/144 244/190 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 3-13,7-12: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-0 oc purlins, except 2-0-0 oc purlins (2-7-15 max.): 3-7. BOT CHORD Rigid ceiling directly applied or 7-9-3 oc bracing. WEBS 1 Row at midpt 4-12 REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-107(LC 27) Max Uplift 2=-799(LC 5), 8=-799(LC 4) Max Grav 2=2922(LC 35), 8=2922(LC 36) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4504/1359, 3-4=-5536/1779, 4-6=-5529/1776, 6-7=-5529/1776, 7-8=-4506/1360 BOT CHORD 2-15=-1151/3716, 13-15=-1156/3735, 12-13=-1786/5627, 10-12=-1057/3685, 8-10=-1052/3665 WEBS 3-15=-261/1003, 3-13=-850/2316, 4-13=-488/197, 6-12=-462/179, 7-12=-847/2306, 7-10=-263/1007 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=799, 8=799. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 242 lb down and 104 lb up at 3-10-3, 143 lb down and 74 lb up at 5-10-3, 164 lb down and 98 lb up at 7-10-4, 164 lb down and 98 lb up at 9-10-4, 164 lb down and 98 lb up at 11-10-4, 169 lb down and 98 lb up at 13-10-4, 169 lb down and 98 lb up at 15-10-4, 169 lb down and 98 lb up at 17-10-4, 169 lb down and 98 lb up at 19-9-8, 169 lb down and 98 lb up at 21-8-13, 169 lb down and 98 lb up at 23-8-13, 169 lb down and 98 lb up at 25-8-13, 164 lb down and 98 lb up at 27-8-13, 164 lb down and 98 lb up at 29-8-13, 164 lb down and 98 lb up at 31-8-13, and 143 lb down and 74 lb up at 33-8-13, and 242 lb down and 104 lb up at 35-8-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss TG03 Truss Type Hip Girder Qty 2 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589729 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:24 2020 Page 2 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-HqHeq7mC0MIFfpZZFf85j3ZvnJ6aFfkSEsYorNzblUz 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-54, 7-9=-54, 2-8=-20 Concentrated Loads (lb) Vert: 14=-143 15=-143 13=-151 12=-151 10=-143 11=-143 16=-242 17=-143 18=-143 19=-151 20=-151 21=-151 22=-151 23=-151 24=-143 25=-143 26=-242 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss TG04 Truss Type Half Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589730 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:25 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-l0q01TnrngQ6Hz8mpNfKFH5AqjYD_HjbTWIMNpzblUy Scale = 1:11.2 1 2 3 4 6 57 3x4 2x4 2x4 2x4 2x4 1-1-0 1-1-0 2-0-0 0-11-0 -2-3-0 2-3-0 1-1-0 1-1-0 2-0-0 0-11-0 1-1-81-8-01-4-80-3-81-8-06.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.35 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-6: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=65(LC 35) Max Uplift 6=-76(LC 8), 5=-128(LC 28) Max Grav 6=261(LC 1), 5=53(LC 40) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb) 5=128. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 49 lb down and 130 lb up at 1-1-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss TG04 Truss Type Half Hip Girder Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589730 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:25 2020 Page 2 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-l0q01TnrngQ6Hz8mpNfKFH5AqjYD_HjbTWIMNpzblUy LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-4=-54, 5-6=-20 Concentrated Loads (lb) Vert: 7=38(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V01 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589731 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:26 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-DCOOFpoTYzYzu7jyM4AZoUeOv6sXjjGkiA1vvFzblUx Scale = 1:42.3 1 2 3 4 5 8 7 6 11 12 9 103x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-4 0-0-4 13-2-15 13-2-11 6-7-8 6-7-8 13-2-15 6-7-8 0-0-46-7-80-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.14 0.14 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 44 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-2-7. (lb) - Max Horz 1=115(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-148(LC 10), 6=-148(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=311(LC 17), 8=363(LC 17), 6=363(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-4-4, Exterior(2R) 3-4-4 to 9-10-12, Exterior(2E) 9-10-12 to 12-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=148, 6=148. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V02 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589732 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:27 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-hPymS9p5IHgqWHI8wnioLiBX5WDQSA4uwqnTRhzblUw Scale = 1:34.1 1 2 3 4 5 8 7 6 9 10 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 10-6-11 10-6-11 10-6-15 0-0-4 5-3-8 5-3-8 10-6-15 5-3-8 0-0-45-3-80-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.30 0.10 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-6-7. (lb) - Max Horz 1=-91(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-161(LC 10), 6=-161(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=316(LC 17), 6=316(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-268/266, 4-6=-268/266 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-4-4, Exterior(2R) 3-4-4 to 7-2-12, Exterior(2E) 7-2-12 to 10-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=161, 6=161. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V03 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589733 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:28 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-9bW8gVpj3boh8RtLUVD1tvjhbwXoBeo19UW0_8zblUv Scale = 1:26.4 1 2 3 4 5 6 2x4 4x6 2x4 2x4 0-0-4 0-0-4 7-10-15 7-10-11 3-11-8 3-11-8 7-10-15 3-11-8 0-0-43-11-80-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.38 0.22 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-10-7, 3=7-10-7, 4=7-10-7 Max Horz 1=-66(LC 6) Max Uplift 1=-29(LC 11), 3=-29(LC 11) Max Grav 1=158(LC 1), 3=158(LC 1), 4=218(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-4 to 3-4-4, Exterior(2R) 3-4-4 to 4-6-12, Exterior(2E) 4-6-12 to 7-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V04 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589734 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:28 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-9bW8gVpj3boh8RtLUVD1tvjkxwZrBeC19UW0_8zblUv Scale = 1:18.5 1 2 3 4 2x4 4x6 2x4 2x4 0-0-4 0-0-4 5-2-15 5-2-11 2-7-8 2-7-8 5-2-15 2-7-8 0-0-42-7-80-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.09 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-2-7, 3=5-2-7, 4=5-2-7 Max Horz 1=-42(LC 6) Max Uplift 1=-18(LC 11), 3=-18(LC 11) Max Grav 1=99(LC 1), 3=99(LC 1), 4=137(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V05 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589735 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:29 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-dn4XtqqLquwYlaSX2CkHQ7GxfKvSw5iBO8GZWazblUu Scale = 1:9.2 1 2 3 2x4 3x4 2x4 0-0-4 0-0-4 2-6-15 2-6-11 1-3-8 1-3-8 2-6-15 1-3-8 0-0-41-3-80-0-412.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-6-7, 3=2-6-7 Max Horz 1=-17(LC 8) Max Uplift 1=-2(LC 11), 3=-2(LC 11) Max Grav 1=69(LC 1), 3=69(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V06 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589736 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:30 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-5_ev4ArzbC2PNk1jbwFWyKp2ZkF5fY2Kdo?720zblUt Scale = 1:25.5 1 2 3 4 5 8 7 6 9 10 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-6 0-0-6 12-2-10 12-2-4 6-1-5 6-1-5 12-2-10 6-1-5 0-0-44-0-140-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.29 0.10 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-1-14. (lb) - Max Horz 1=-69(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=273(LC 17), 6=273(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 8-8-14, Exterior(2E) 8-8-14 to 11-8-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V07 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589737 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:31 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-aACHIWscMWAG?ucv9dmlVYLFs7b6O?sTrSlgaTzblUs Scale = 1:15.0 1 2 3 4 2x4 4x6 2x4 2x4 0-0-6 0-0-6 6-2-10 6-2-4 3-1-5 3-1-5 6-2-10 3-1-5 0-0-42-0-140-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.19 0.12 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-1-14, 3=6-1-14, 4=6-1-14 Max Horz 1=-32(LC 6) Max Uplift 1=-16(LC 10), 3=-21(LC 11) Max Grav 1=103(LC 1), 3=103(LC 1), 4=182(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V08 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589738 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:31 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-aACHIWscMWAG?ucv9dmlVYLCS7b7O?FTrSlgaTzblUs Scale = 1:17.6 1 2 3 5 4 2x4 2x4 2x4 2x4 2x4 8-5-6 8-5-6 0-0-42-9-134.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.34 0.12 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-4-10, 4=8-4-10, 5=8-4-10 Max Horz 1=78(LC 9) Max Uplift 4=-12(LC 10), 5=-53(LC 10) Max Grav 1=93(LC 1), 4=111(LC 1), 5=343(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-250/250 NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V09 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589739 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:32 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-2MmfVstE7pI6d2B6jLH_2luFxXoa7SSd46UE7vzblUr Scale = 1:14.0 1 2 3 2x4 2x4 2x4 6-5-6 6-5-6 0-0-42-1-134.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.87 0.61 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-4-10, 3=6-4-10 Max Horz 1=57(LC 7) Max Uplift 1=-18(LC 6), 3=-27(LC 10) Max Grav 1=200(LC 1), 3=200(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V10 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589740 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:33 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-WYJ1jCtsu7QzECmIH2oDazRZHxEtsvimJmEnfLzblUq Scale = 1:10.1 1 2 3 2x4 2x4 2x4 4-5-6 4-5-6 0-0-41-5-134.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.32 0.23 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-4-10, 3=4-4-10 Max Horz 1=36(LC 7) Max Uplift 1=-12(LC 6), 3=-17(LC 10) Max Grav 1=126(LC 1), 3=126(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902043 Truss V11 Truss Type Valley Qty 1 Ply 1 FISCHER OBF-104 Job Reference (optional) I40589741 8.240 s Feb 7 2020 MiTek Industries, Inc. Thu Mar 12 07:06:33 2020 Page 1 Builders First Source, mooresville,in ID:2gAH6Ie8OEPy5riD?OS3YTzKGpp-WYJ1jCtsu7QzECmIH2oDazRdYxHtsvimJmEnfLzblUq Scale = 1:6.8 1 2 3 2x4 4x6 2-5-6 2-5-6 0-0-40-9-134.00 12 Plate Offsets (X,Y)-- [2:0-1-4,0-0-7], [2:0-11-1,0-1-13], [3:0-1-4,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 7.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-5-6 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-4-10, 3=2-4-10 Max Horz 1=15(LC 7) Max Uplift 1=-5(LC 6), 3=-7(LC 10) Max Grav 1=52(LC 1), 3=52(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). March 12,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths