HomeMy WebLinkAboutS100WILLIAML.KAUFH O L Z
A RCHITECTUP
91
04
A6.0
03
A6.0
03
A6.0
02
A6.0
1101
D3.0
12
D3.0
12
D3.0
1111
11DN
01-03
FP1
04
A6.0
11
10/20
D3.0
261
251
10
D3.0
01
D3.0
519'0"x7'0" O.H. GARAGE DOOR 16'0"x7'0" O.H. GARAGE DOOR251
251251
FLR BRKHB HB112 2
110
51
51
22
14221 6068 SGD 6010 T2860 SH2860 SH
5060 P
210682668OWNER'S SUITE
PWDRFOYER
TWO-CAR GARAGE
WOOD RAILING
LINE OF SECOND FLOOR ABOVE
LINE OF SECOND
FLOOR ABOVE
LINE OF SECOND
FLOOR ABOVE
15'-012"5'-812" 512" 14'-212" 19'-5"
512" 5'-812"512"
10'-8"3'-11"512"14'-9"612" 2'-11"
ARCHED
OPENING
6'-0"
TO NOSING
5'-0"3'-9" 5'-6"
2'-112"
15'-012"
3'-4" 5'-5"16'-1"4'-312" 5'-1"3'-7" 1'-11" 6'-7"3'-0"3'-1"ARCHED OPN'G3'-634"3'-634" 19'-3"3'-634" 714" 6'-912" 714"LINE OF SECOND
FLOOR ABOVE
RADON PIPE
2x4 PAD OUT FOR
HVAC AND PLUMBING
FRAMER'S NOTE
SET T/ GARAGE WALL IN FRONT
OF BEAM AT 9'-212" ABV. T/ FDN.
20'-8" 2'-0" 8'-3" 7'-734" 6'-3"LENGTH OF 3412"h WALL5'-414"6'-3"
TO CABINET 3412"h. 2x4 WALLS- SEE DTL. 01/A6.1
KITCHEN (2)16685'-612"7'-412" 6010 PTEMP24682468OWNER'S
BATH
WIC
8'-3"
3'-4"4'-712" 11'-1012" 1'-6"2'-5"
EGRESS
3060 SH
EGRESS
3060 SH
EGRESS3060 SHHANDRAIL 6'-6" 6'-8"19'-512"6'-312" 1'-8"
TWO-STORY
FAMILY ROOM ACTIVE16'-412"
BALLOON FRAME WALL
3'-212" 3'-0"ARCH. OPEN'G.5 12"3'-21 2"
20-MIN.266814'-1012" 7'-112"
1'-7"
3060 SH
3060 SH
3060 SH
EGRESS
3060 SH
EGRESS
3060 SH
MORNING ROOM26682468
2468
2868 PKT65'' x 84 1/2'' R.O.5'-212" 2468DRYERWASHER
LAUNDRY
GUEST
BATH
2'-612" 5'-0" 4'-0"912"4'-6"2'-2" 1'-512" 4'-5" 3'-0" 1'-0" 1'-6" 2'-312" 11'-812"3'-0" 2'-312" 5'-9" 10'-312"
OPENING
3'-1034"1'-6"
1'-6"
GUEST
SUITE
2450 SH30682450 SH
2860 SH
2860 SH
2860 SH
6'-1078"28
6
8
THIRD-CAR GARAGE
2860 SH
2860 SH2850 SH
2850 SH
1'-23 4" 1'-23 4" 6'-318" 2668512"℄
℄℄1'-81 4"
℄
℄
45°1'-6"℄2'-114"℄℄
℄℄℄2'-11"℄
3010 T℄12" TRANSOM
OVER DOOR (2)26687'-614"6'-034" STUDY 13'-7"512"5'-2"
1'-6"3'-312" 2'-412"7'-2"3'-634"SET T/ WINDOWS @
8'-103 4" ABV. T/ FDN.
SET T/ WINDOWS @
7'-103 4" ABV. T/ FDN.
ADD'T SHOWER
HEAD4'-438"TO ℄ RANGE HOOD /OPT. MICROWAVEFLUSH
BEAM
FRAMERS NOTE:
FRAME GARAGE WALLS @
9'-2 1/2"h. FROM T/FDN
1'-912"512"20-MIN.HIP GIRDER TRUSS ABOVE(2) JACK STUDS
FLUSH BEAM NOTE:
USE (2) 13 4" x 16" MICRO-LAM LVL's
- w/ (4) 2x4 JACK STUDS @ GUEST STE END
& (2) 2x6 JACKS STUDS @ FAM RM END
-SET BTM/ BEAM FLUSH w/ BTM/ FLR JSTS
SPANDREL BEAM NOTE:
USE (2) 2x12's w/ 12" PLYWOOD
FLITCH AS SPANDREL BEAM
- SET FLUSH w/ 2nd FLR. JOISTS
(3) JACK STUDS
(3) JACK STUDS
(2) JACK STUDS
(2) JACK STUDS 3'-1"ARCHED OPN'G 12'-212" 246824684'-10"10'-212"
3'-0" 3'-012"
3'-212"5'-212"℄
1'-6"
1'-8"
℄512" (4) 2x6 JACK
STUDS
12'-1012" 1'-834"7'-0"NO DROPPED HDR @ SHWR DR1'-834" (3) JACK STUDS
BETWEEN WDW'S
FRAMER'S NOTE
SET T/ GARAGE WALL AT 10'-212"
ABV. T/ FDN.21'-0"7"8'-9"
FLUSH BEAM NOTE:
USE (3) 13 4"x20" MICRO-LAM LVL's
- FASTEN PLIES w/ (4) ROWS 16d
NAILS @ 12"o.c.
- SET T/ BEAM FLUSH w/ T/ FLOOR JOISTS
- w/ (4) 2x6 J.S. EACH SIDE
- EXTEND BEAM TO FULLY COVER JACK
STUDS
- PROVIDE 2x4 KING STUD @ EACH SIDE
OF JACK STUDS, SEE DTL. 04/D3.0
45 8"
PAD DOWN UNDERSIDE OF LVL 3 12"
@ MONO TURSSES 1012" 8'-812" 1012" - REFER TO DETAILS, SHEET D5.1
16'-0"w. x 12'-0"d. COVERED DECK
NOTE:
VENT MICROWAVE / RANGE
HOOD TO EXTERIOR
- DROP CEILING TO 8'-1"
10'-7 1/2"w. x 5'-6"d. CONCRETE PORCH
918" 918"
2x4 FLAT
FRAME WALL
16" O.C.
WALL OVEN
FRAME T/ OP'NG
@ 83 14" A.F.F.
FRAME T/ OP'NG
@ 83 14" A.F.F.
VENT FAMILY ROOM
FIREPLACE THROUGH
ATTIC TRUSSES
5'-23 4"2'-812" 7'-43 4" 2'-111 4" 8'-81 4" 3'-012" 3'-012" 6'-23 8" 3'-012" 7'-03 8" 3'-012" 3'-73 4" 1'-6" 9'-0"1'-6"
15'-4"40'-8" 12'-0"
68'-0"17'-814" 8'-014" 13'-1012" 5'-8" 6'-4"2'-0" 39'-7" 12'-0"53'-7"2'-83 4"10'-2" 7'-3" 4'-512" 4'-512" 2'-1114" 2'-1112" 3'-412" 3'-412" 6'-912" 3'-412" 4'-112"
32'-0"24'-0" 12'-0"
68'-0"2'-1034" 16'-0" 2'-814" 3'-212" 18'-912"21'-7" 22'-0" 10'-0"53'-7"OVERBROOK FARMSREASON FOR PLOT: PLOT DATE:Job No.
Sheet No.IN HOMESITE NO.OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVEDFISCHER HOMES, Inc.JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:3/9/2020 12:25 PM# OBF011040000MITCHELL WISE4009 BEAR CREEK WAYLELAND57-442-LELAND COASTAL CLASSIC WITH BRICK & STONECARMEL, IN10405/2017-------- ------------ --------------------------------fieldspecchange@fischerhomes.comREVISED BY:---- THERESA WISEARCH. SPECIALIST:SAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.comFischer Homes Indianapolis II, LLC----A3.0
1 X
XX
2 X
3 X
4 X
5 X
6 X
7 X
8 X
9 X
10 X
11 X
12 X
13 X
14 X
15 X
16 X
17 X
18 X
19 X
20 X
21 X
22 X
23 X
24 X
LEGEND - STRUCTURAL HEADERS and BEAMS:
(1) 2x12 Header
(2) 2x12 Header
(2) 2x12 Header - w/ 12" Plywood Flitch ⅊
(3) 2x12 Header
(1) 2x10 Header
(2) 2x10 Header
(2) 2x10 Header - w/ 12" Plywood Flitch ⅊
(3) 2x10 Header
(1) 2x8 Header
(2) 2x8 Header
(2) 2x8 Header - w/ 12" Plywood Flitch ⅊
(3) 2x8 Header
(1) 13 4" x 1114" LVL Header
(2) 1 3 4" x 1114" LVL Header
(3) 1 3 4" x 1114" LVL Header
(4) 1 3 4" x 1114" LVL Header
(1) 1 3 4" x 914" LVL Header
(2) 1 3 4" x 914" LVL Header
(3) 1 3 4" x 914" LVL Header
(4) 1 3 4" x 914" LVL Header
(1) 1 3 4" x 714" LVL Header
(2) 13 4" x 714" LVL Header
(3) 13 4" x 714" LVL Header
(4) 1 3 4" x 714" LVL Header
NOTE: Bold number identifies header type, small
number in corner identifies # of jack
studs on each side of header / beam.
- No. of jack studs will vary - refer to plan.
No. of Jack Studs, ea. side
Header Type
0 No Header
25 X
26 X
27 X
28 X
(1) 2x12 Header
w/ (1) Jack Stud @ each side of each window
(2) 2x12 Header
w/ (1) Jack Stud @ each side of each window
(1) 2x10 Header
w/ (1) Jack Stud @ each side of each window
(2) 2x10 Header
w/ (1) Jack Stud @ each side of each window
29 X
30 X
(1) 1 34" x 14" LVL Header
(2) 134" x 14" LVL Header
31 X
32 X
(1) 1 34" x 16" LVL Header
(2) 134" x 16" LVL Header
33 X
34 X
(1) 1 34" x 18" LVL Header
(2) 1 34" x 18" LVL Header
35 X
36 X
(1) 1 34" x 20" LVL Header
(2) 1 34" x 20" LVL Header
FLOOR PLAN NOTE:
1. ALL EXTERIOR WALLS SHALL BE
FRAMED @ 16" o.c.
2. INTERIOR WALLS SHADED AS
INDICATES INTERIOR LOAD BEARING WALL TO
BE FRAMED @ 19.2" o.c. (UNLESS OTHERWISE
NOTED ON PLAN)
- ALIGN JOISTS w/ STUDS.
3. INTERIOR WALLS SHADED AS
INDICATES INTERIOR WALLS TO BE FRAMED
@ 16" o.c.
SCALE = 1'-0"
FIRST FLOOR FRAMING PLAN
1/4"01
ROOM OPENING HEADER NOTE:
8'-1" 1st FLOOR PLATE HEIGHT: FRAME ALL 1st FLOOR
ROOM OPENING HEADERS AT 81 1 4"* OFF SUBFLOOR FOR
ALL FLOOR MATERIALS
9'-1" 1st FLOOR PLATE HEIGHT: FRAME ALL 1st FLOOR
ROOM OPENING HEADERS AT 93 1 4"* OFF SUBFLOOR FOR
ALL FLOOR MATERIALS
10'-1" 1st FLOOR PLATE HEIGHT: FRAME ALL 1st FLOOR
ROOM OPENING HEADERS AT 105 14"* OFF SUBFLOOR FOR
ALL FLOOR MATERIALS
WINDOW HEADER NOTE:
* UNLESS OTHERWISE NOTED ON PLANS
8'-1" PLATE HEIGHT: FRAME ALL WINDOW HEADERS AT
81 14"* OFF SUBFLOOR FOR ALL FLOOR MATERIALS
9'-1" PLATE HEIGHT: FRAME ALL WINDOW HEADERS AT
93 14"* OFF SUBFLOOR FOR ALL FLOOR MATERIALS
10'-1" PLATE HEIGHT: FRAME ALL WINDOW HEADERS AT
105 1 4"* OFF SUBFLOOR FOR ALL FLOOR MATERIALS
* UNLESS OTHERWISE NOTED ON PLANS
04/17/20
William Hohlt