Loading...
HomeMy WebLinkAboutM100.0CEILING WALL FLOOR T COLD AIR RETURN HVAC KEY FLOOR SUPPLY REGISTER WALL SUPPLY REGISTER CEILING SUPPLY REGISTER EXTERIOR WALL EXHAUST VENT THERMOSTAT DRYER BOX G W GAS SHUT-OFF KEY PLUMBING KEY MAIN WATER SHUT-OFF ICE MAKER BOX LAUNDRY BOX FROST PROOF HOSE BIB CLEAN OUT TILE-IN DRAIN FLOOR DRAIN ELECTRICAL KEY REF. OUTLET MICRO.OUTLET DW POWER SUPPLY HOOD VENT POWER SUPPLY GB POWER SUPPLY DIMMER SWITCH SURFACE MOUNT LIGHT FIXTURE 6" RECESSED CAN LIGHT 4" RECESSED CAN LIGHT 6" RECESSED CAN/FAN UNIT EXHAUST FAN ONLY EXHAUST FAN W/ LIGHT WALL MOUNTED SCONCE / LIGHT CEILING FAN LOW VOLTAGE LIGHT SMOKE DETECTOR MOTION SENSOR CEILING SPEAKER LOW VOLTAGE LIGHTING SWITCH GARBAGE DISPOSAL SWITCH COUNTERTOP AIR SWITCH SINGLE POLE SWITCH LOW VOLTAGE TRANSFORMER 220/240V OUTLET EXTERIOR OUTLET GFCI OUTLET 110V OUTLET GAS COOKTOP CLOTHS DRYER OUTLET 4-WAY SWITCH 3-WAY SWITCH 3068 3068 40682668 26682668 26682068 6068 246870682468 WALLWALLWALLWALL WALLWALL WALLR 4'-5 1/8"10'-7"9'-11"3'-2"7'-9 1/2" 8'-9 3/4" 1'-4" 6'-6"7'-11"2'-1"3'-2"7'-8"2'- 1 1" 2'-11 7/8"11'-3 5/8"19'-3 1/2"6'-11 1/2" 3'4'-11 1/8"3'-6 7/8" 5' 3'-7 5/8" BASEMENT E1E1 M.E.P PLAN NOTES REPLACE EXISTING SCONCE INSTALL NEW CAN LIGHT INSTALL NEW EXHAUST FAN INSTALL NEW SWITCH ROUTE HVAC TO NEW LOCATION SMOKE DETECTORS AND CO DETECTORS WILL BE BROUGHT UP TO THE NEW INDIANA STATE ADOPTED IN2020 RESIDENTIAL CODE E1E1 E2E2 E3E3 E4E4 E5E5 E6E6 E1E1 E2E2 E3E3 E4E4 E5E5 E6E6 E2E2 E3E3 E4E4 E4E4 E4E4 E5E5 E5E5 2X10 FLOOR JOIST EXTENSION (SEE ENGINEER DETAILS) E6E6 Nieman's ResidenceInterior Remodel1603 Springmill Ponds CircleCarmel, IN 46032Date:Revision: 5 SHEET OF 11 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts and ideas, forming a part of the plans, and the selection and arrangement thereof Copright 2018 by Custom Living, Inc., Indianapolis IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans, or their content, without the prior written permission of Custom Living. Inc is strictly prohibited. PROPOSED M.E.P PLAN SCALE: 1/4" = 1'CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462204/27/2020 DATE: GENERAL M.E.P NOTES HVAC Contractor is responsible for engineering calculation necessary for correct sizing of new equipment and ducwork being supplied,fabricated and installed for the project. HVAC ductwork being installed in unconditioned areas to be insulated and sealed per current Building Code Standards. HVAC contractor to start up, test and balance new equipment and ductwork to assure proper operation of new systems. Final plumbing materials selected may have an affect on the final Plumbing Material and Installation Budgets. Owners understand that if additonal plumbing, electrical or ductwork is foun in walls being deleted that is not included on the plans there will be a Change Order during construction to relocate as necessary. Owners understand that during mechanical rough-ins there will be times when the water service will be shut of to areas in the home. Plumbing and Lighting fixtures supplied by Owner will not be Warrantied by Custom Living Plumbing and Lighting fixtures supplied by Owner must be selected and onsite prior to start of Mechanical Rough-In's [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] DESIGNER: EMMA MAXWELLE: emma@customlivingusa.comC: 574.292.244104/29/20 Mike Sheeks