HomeMy WebLinkAboutM002.0 Start HereProducts
PlotID Length Product Plies Net Qty
J1 36' 0"11-7/8" AJS® 150 1 9
J2 22' 0"11-7/8" AJS® 150 1 2
J3 18' 0"11-7/8" AJS® 150 1 15
J4 16' 0"11-7/8" AJS® 150 1 2
J5 12' 0"11-7/8" AJS® 150 1 1
BM1 16' 0"1-3/4" x 9-1/4" VERSA-LAM® 2.0 3100 SP 1 1
DB1 8' 0" 1-3/4" x 9-1/4" VERSA-LAM® 2.0 3100 SP 1 1
DB2 14' 0"1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 3 3
FB1 12' 0"1-3/4" x 11-7/8" VERSA-LAM® 2.0 3100 SP 1 1
DB3 20' 0"1-3/4" x 14" VERSA-LAM® 2.0 3100 SP 2 2
FB2 20' 0"1-3/4" x 16" VERSA-LAM® 2.0 3100 SP 2 2
FB3 12' 0"11-7/8" AJS® 150 1 1
FB4 10' 0"11-7/8" AJS® 150 1 1
FB5 4' 0" 11-7/8" AJS® 150 1 1
Rim 1-1/8" x 11-7/8" BC RIM BOARD OSB 12' 0"1-1/8" x 11-7/8" BC RIM BOARD OSB 1 13
Blocking1 24' 0"11-7/8" AJS® 150 1 1
Connector Summary
PlotID Qty Manuf Product
H1 4 Simpson ITS 2.56/11.88
Thislayout and associated materials list has been prepared based on project plansand/or information provided to Carter-Lee. It remains the responsibilityofthe builderarchitect,designer,or other responsible personsto reviewthis information to assurethat it is appropriate,accurate,complete and complieswithapplicable building codes.GENERAL NOTES1.)READTHE INSTALLATION GUIDE BEFORE FRAMING.2.)ALL WALL SHOWN ARE LOADBEARING UNLESS NOTESOTHERWISE WALLS NOT SHOWN HAVE BEEN CONSIDEREDNON-LOADBEARING3.)UNLESS STATEDOTHERWISE ALL CEILING &ROOF LOADSBRACE DIRECTLYTO LOADBEARING WALLS SUPPORTEDBYFOUNDATION4.)CONTACT YOU LOCAL BUILDERS FIRSTSOURCE LOCATIONBEFORE MAKING ANYALTERATION &ADJUSTMENTS,FAILUREMAYRESULT IN COSTLYREPAIRS
Sheet
1 of 1
OFFSET ONE JOIST UP TO 3" IN
EITHER DIRECTION FOR DRAIN
CLEARENCE, NOT TO EXCEED
SUBFLOOR SPAN RATING
Builder
Pyatt Builders
Layout Name
70 The Grove Largacy
Building Option
Chelsea
Designer
Eric Toussant
Created
4/15/2020
Salesperson
Mike Eder
Design Method - ASD
Building Code - IBC/IRC 2015
FLOORLOADS
Live 40
Dead 12
DEFLECTIONJOIST
LL Span L/ 480
TL Span L/ 240
LL Cant. 2L/480
TL Cant. 2L/ 240
DEFLECTIONGIRDER
LL Span L/ 360
TL Span L/ 240
LL Cant. 2L/360
TL Cant. 2L/ 240
DECKING OSB
23/32 APA Rated
Sturd-I-Floor
FASTENER
Nailed &Glued
Scale: Not To Scale
Carter-Lee
(317)639-5431
GARAGE DOOR HEADERS MUST BE INSTALLED PER APPLICABLE CODES
04/28/20
David Rutti