HomeMy WebLinkAboutSouthill A Q1421009
Carter-Lee Bldg (Moorseville).
July 31, 2012.My license renewal date for the state of Indiana is
Pages or sheets covered by this seal:
SOUTHILL ELEV. A
Taimur Shamali, PE
The truss drawing(s) referenced below have been prepared by ProBuild East under my direct supervision
based on the parameters provided by
The seal on these drawings indicate acceptance of professional engineering responsibility solely for the
truss components shown. The suitability and use of this component for any particular building is the
responsibility of the building designer, per ANSI/TPI-2002 Sec. 2.
Re:
thru I4601335I4601302
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ProBuild - East Region
January 20,2011
Job
Q1421009
Truss
GE1
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601302
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:24 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:30.3
1-5
5-9
2-8
5-12
4-13
3-14
6-11
7-10
Sheet Front
Full Sheathing
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1
2
3
4
5
6
7
8
9
14 13 12 11 10
4x6
2x4 2x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
10-0-0
10-0-0
-0-11-4
0-11-4
5-0-0
5-0-0
10-0-0
5-0-0
10-11-4
0-11-4
0-4-134-6-130-4-1310.00 12
Plate Offsets (X,Y): [2:0-2-1,0-1-0], [8:0-2-1,0-1-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.09
0.05
0.05
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
0.00
0.00
0.00
(loc)
8
8
8
9
l/defl
n/r
n/r
n/a
n/r
L/d
180
120
n/a
120
PLATES
MT20
Weight: 45 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 10-0-0.
(lb) - Max Horz 2=-136(LC 3)
Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 13, 14, 11, 10
Max Grav All reactions 250 lb or less at joint(s) 2, 8, 12, 13, 14, 11, 10
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 14, 11,
10.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GE2
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601303
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:25 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:52.4
1-4
4-7
2-8
4-8
5-83-8
9-1011-12
11-13
14-15
14-1617-18
19-20
21-22
23-24 25-27
26-27
28-30
29-30 31-32
33-34
35-36
6-8
Sheet Front
Left Option 10-4-0
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1
2
3
4
5
6
7
8
4x6
5x6
5x12
5x6
10-0-0
10-0-0
10-4-0
0-4-0
20-0-0
9-8-0
-0-11-4
0-11-4
5-1-15
5-1-15
10-0-0
4-10-1
14-10-1
4-10-1
15-4-14
0-6-13
20-0-0
4-7-2
20-11-4
0-11-4
0-4-138-8-130-4-1310.00 12
Plate Offsets (X,Y): [2:0-1-6,Edge], [6:0-1-6,Edge], [8:0-6-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.43
0.78
0.23
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.17
-0.45
0.03
0.05
(loc)
2-8
2-8
6
2-8
l/defl
>999
>521
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 135 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud *Except*
4-8: 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-5-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)2=853/0-3-8, 6=853/0-3-8
Max Horz 2=-267(LC 3)
Max Uplift 2=-172(LC 5), 6=-172(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-958/192, 3-4=-747/210, 4-5=-747/210, 5-6=-958/192
BOT CHORD 2-8=-121/681, 6-8=-48/681
WEBS 4-8=-111/588, 5-8=-258/226, 3-8=-258/225
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=172, 6=172.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GE3
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601304
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:25 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:49.6
2-24
1-7
7-13
12-14
14-24
7-19
6-20
5-21
4-22
3-23
8-18
9-17
10-16
11-15
Sheet Front
Full Sheathing
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1
2
3
4
5
6
7
8
9
10
11
12
13
24 23 22 21 20 19 18 17 16 15 14
3x8
4x6
3x8 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
12-11-0
12-11-0
-0-11-4
0-11-4
6-5-8
6-5-8
12-11-0
6-5-8
13-10-4
0-11-4
0-9-07-2-80-9-012.00 12
Plate Offsets (X,Y): [11:0-0-0,0-0-0], [14:0-2-4,0-0-0], [24:0-2-4,0-0-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.29
0.14
0.16
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
-0.01
0.00
0.00
(loc)
13
13
14
13
l/defl
n/r
n/r
n/a
n/r
L/d
180
120
n/a
120
PLATES
MT20
Weight: 78 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 12-11-0.
(lb) - Max Horz 24=203(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 14, 20, 21, 22, 18, 17, 16 except 24=-133(LC 3), 23=-143(LC 4),
15=-130(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 20, 21, 22, 18,
17, 16 except (jt=lb) 24=133, 23=143, 15=130.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GE4
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601305
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:26 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:70.7
2-13
5-6
6-7
4-13
6-13
8-13
2-3
9-10
15-16
15-17
18-19
18-20
5-21
21-22
23-2425-26
27-28
29-31
30-31
32-34
33-34
7-36
35-36
37-38 39-40 41-42
10-13
1-5
3-14 9-12
Sheet Front
Left Option 10-4-0
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1
2
3
4
5
6
7
8
9
10
11
14 13 123x8
3x4
3x4
4x6
5x8
4x8
3x8
3x4
3x4
4x8
5x6 5x6
10-4-0
10-4-0
11-0-0
0-8-0
22-0-0
11-0-0
-0-11-4
0-11-4
5-5-12
5-5-12
11-0-0
5-6-4
16-6-4
5-6-4
16-6-8
0-0-4
22-0-0
5-5-8
22-11-4
0-11-4
0-9-011-9-00-9-012.00 12
Plate Offsets (X,Y): [2:0-3-8,Edge], [2:3-2-8,0-1-14], [3:0-1-12,0-2-0], [5:0-3-0,0-3-0], [7:0-3-0,0-3-0], [9:0-1-12,0-2-0], [10:0-4-1,Edge], [10:3-2-1,0-1-8], [13:0-4-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.54
0.59
0.44
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.10
-0.26
0.03
0.06
(loc)
13-14
13-14
10
13-14
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 194 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
3-14,9-12: 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud *Except*
15-16,29-31: 2 X 4 SPF No.2
SLIDER Left 2 X 4 SPF Stud 4-0-13, Right 2 X 4 SPF Stud 4-0-13
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-9-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)2=936/0-3-8, 10=936/0-3-8
Max Horz 2=360(LC 4)
Max Uplift 2=-166(LC 5), 10=-166(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1071/146, 3-4=-853/227, 4-5=-756/242, 5-6=-635/277, 6-7=-635/277,
7-8=-756/242, 8-9=-853/227, 9-10=-1071/146
BOT CHORD 2-14=-155/633, 13-14=-155/633, 12-13=-25/633, 10-12=-25/633
WEBS 4-13=-282/262, 6-13=-190/613, 8-13=-282/262
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=166, 10=166.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GE5
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601306
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:28 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:65.2
4-15
15-26
2-43
15-4214-4413-4512-4611-4710-489-498-507-516-525-53
3-54
16-41 17-39 18-38 19-37 20-36 21-35 22-34 23-33 24-32 25-31
27-30
1-4
26-2928-4040-43
Sheet Front
Full Sheathing
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1 2
3
4 5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30
3x6
4x6
3x6
3x4
3x6 3x6
3x4
34-0-0
34-0-0
-0-11-4
0-11-4
17-0-0
17-0-0
34-0-0
17-0-0
34-11-4
0-11-4
0-4-510-3-50-4-57.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.16
0.06
0.09
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
0.00
0.01
0.00
(loc)
28
28
28
29
l/defl
n/r
n/r
n/a
n/r
L/d
180
120
n/a
120
PLATES
MT20
Weight: 225 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud *Except*
15-42,14-44,13-45,12-46,16-41,17-39,18-38: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 15-42, 14-44, 13-45, 16-41, 17-39
REACTIONS All bearings 34-0-0.
(lb) - Max Horz 2=315(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 2, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 39, 38, 37, 36,
35, 34, 33, 32, 31, 30, 28
Max Grav All reactions 250 lb or less at joint(s) 2, 42, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 41, 39,
38, 37, 36, 35, 34, 33, 32, 31, 30, 28
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-279/203, 13-14=-31/266, 14-15=-31/271, 15-16=-31/266
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 44, 45, 46, 47,
48, 49, 50, 51, 52, 53, 54, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 28.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GE6
Truss Type
GABLE
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601307
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:29 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:66.6
2-12
4-5
5-6
3-13
5-11
7-9
3-11
7-11
14-1516-17
16-18
19-20
19-21
22-23
22-24
4-25
25-2627-2829-3031-3233-34
35-36
37-38 39-41
40-41
42-44
43-44
45-47
46-47
6-49
48-49 50-51 52-53 54-55 56-57
58-59
8-1010-12
1-4 6-8
Sheet Front
Right Option 5-0-0
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1 2
3
4
5
6
7
8
13 12 11 10 93x12
3x6
5x10 MT18H
3x6
3x8
3x6
5x6
5x6
3x6
3x12
8-8-13
8-8-13
17-0-0
8-3-3
25-3-3
8-3-3
29-0-0
3-8-13
34-0-0
5-0-0
-0-11-4
0-11-4
8-8-13
8-8-13
14-2-5
5-5-8
17-0-0
2-9-11
25-3-3
8-3-3
34-0-0
8-8-13
0-4-510-3-50-4-57.00 12
Plate Offsets (X,Y): [2:1-0-1,0-0-14], [4:0-3-0,0-3-0], [6:0-3-0,0-3-0], [8:1-0-1,0-0-14]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.70
0.92
0.33
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.14
-0.46
0.12
0.18
(loc)
8-9
8-9
8
8-9
l/defl
>999
>875
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT18H
Weight: 250 lb
GRIP
197/144
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
1-4,6-8: 2 X 4 SYP No.1
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
3-13,7-9: 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud *Except*
14-15,37-38: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-4-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-7-15 oc bracing.
WEBS 1 Row at midpt 3-11, 7-11
REACTIONS (lb/size)2=1414/0-3-8, 8=1347/0-3-8
Max Horz 2=323(LC 4)
Max Uplift 2=-277(LC 5), 8=-225(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2199/362, 3-4=-1496/300, 4-5=-1364/345, 5-6=-1364/344, 6-7=-1496/299,
7-8=-2203/369
BOT CHORD 2-13=-313/1788, 12-13=-313/1788, 11-12=-313/1788, 10-11=-194/1793, 9-10=-194/1793,
8-9=-194/1793
WEBS 3-13=0/370, 5-11=-126/905, 7-9=0/371, 3-11=-740/301, 7-11=-746/307
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are MT20 plates unless otherwise indicated.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=277, 8=225.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GE7
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601308
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:30 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:57.4
5-13
13-21
2-34
13-3512-3611-3710-389-39
8-407-416-424-433-44
14-33 15-32 16-31 17-30
18-29 19-28 20-27 22-26 23-251-5 21-24
24-34
Sheet Front
Full Sheathing
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1 2
3
4 5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25
3x6
4x6
3x6
3x4
3x6
3x4
30-1-4
30-1-4
-0-11-4
0-11-4
15-0-0
15-0-0
30-1-4
15-1-4
30-11-4
0-10-0
0-4-59-1-50-3-97.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.13
0.09
0.09
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
0.00
0.01
-0.00
(loc)
1
1
24
1
l/defl
n/r
n/r
n/a
n/r
L/d
180
120
n/a
120
PLATES
MT20
Weight: 181 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud *Except*
13-35,12-36,11-37,14-33,15-32: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 13-35
REACTIONS All bearings 30-1-4.
(lb) - Max Horz 2=286(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 2, 36, 37, 38, 39, 40, 41, 42, 43, 44, 33, 32, 31, 30, 29, 28,
27, 26, 25
Max Grav All reactions 250 lb or less at joint(s) 2, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 33, 32, 31, 30,
29, 28, 27, 26, 25, 24
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 1-4-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 36, 37, 38, 39,
40, 41, 42, 43, 44, 33, 32, 31, 30, 29, 28, 27, 26, 25.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GR1
Truss Type
ROOF TRUSS
Qty
1
Ply
3
SOUTHILL ELEV. A
Job Reference (optional)
I4601309
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:49:09 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:70.7
1-4
4-5
1-11
4-12
6-12 6-103-123-131-2
7-8
5-9
8-11
1
2
3
4
5
6
7
8
9
13 12 11 1014151617181920 21 22 23
8x16
6x6
6x6
4x8
3x6
4x8 10x10
3x12
3x8
3x12
3x8 8x16
6x6
6x6
5-6-12
5-6-12
11-0-0
5-5-4
16-5-4
5-5-4
22-0-0
5-6-12
5-6-12
5-6-12
11-0-0
5-5-4
16-5-4
5-5-4
22-0-0
5-6-12
22-11-4
0-11-4
0-9-011-9-00-9-012.00 12
Plate Offsets (X,Y): [1:Edge,0-4-8], [8:Edge,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.55
0.38
0.73
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.09
-0.22
0.05
0.08
(loc)
10-12
10-12
8
10-12
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 483 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 6 SYP DSS
WEBS 2 X 4 SPF No.2 *Except*
6-10,3-13: 2 X 4 SPF Stud
SLIDER Left 2 X 10 SYP No.1 3-8-15, Right 2 X 10 SYP No.1 3-8-15
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1=9393/0-3-8, 8=10035/0-3-8
Max Horz 1=-368(LC 3)
Max Uplift 1=-1542(LC 6), 8=-1666(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-9624/1581, 2-3=-9550/1627, 3-4=-6662/1260, 4-5=-6474/1262, 5-6=-6659/1227,
6-7=-9504/1630, 7-8=-9580/1584
BOT CHORD 1-14=-1145/6672, 14-15=-1145/6672, 15-16=-1145/6672, 13-16=-1145/6672,
13-17=-1145/6672, 17-18=-1145/6672, 12-18=-1145/6672, 12-19=-1014/6625,
11-19=-1014/6625, 11-20=-1014/6625, 10-20=-1014/6625, 10-21=-1014/6625,
21-22=-1014/6625, 22-23=-1014/6625, 8-23=-1014/6625
WEBS 4-12=-1586/8900, 6-12=-2889/697, 6-10=-630/3975, 3-12=-2958/702, 3-13=-630/4040
NOTES
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-4-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=1542, 8=1666.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1332 lb down and 238 lb up at
0-9-4, 1571 lb down and 257 lb up at 2-9-4, 1571 lb down and 257 lb up at 4-9-4, 1571 lb down and 257 lb up at 6-9-4, 1571 lb
down and 257 lb up at 8-9-4, 1571 lb down and 257 lb up at 10-9-4, 1571 lb down and 257 lb up at 12-9-4, 1571 lb down and 257
lb up at 14-9-4, 1571 lb down and 257 lb up at 16-9-4, 1331 lb down and 238 lb up at 18-9-4, and 1331 lb down and 238 lb up at
20-9-4, and 1068 lb down and 144 lb up at 21-10-4 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
LOAD CASE(S) StandardContinued on page 2
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GR1
Truss Type
ROOF TRUSS
Qty
1
Ply
3
SOUTHILL ELEV. A
Job Reference (optional)
I4601309
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:49:09 2011 Page 2 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-4=-60, 4-9=-60, 1-8=-20
Concentrated Loads (lb)
Vert: 12=-1571(B) 8=-1068(B) 14=-1332(B) 15=-1571(B) 16=-1571(B) 17=-1571(B) 18=-1571(B) 19=-1571(B) 20=-1571(B) 21=-1571(B) 22=-1331(B) 23=-1331(B)
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
Job
Q1421009
Truss
GR2
Truss Type
ROOF TRUSS
Qty
1
Ply
2
SOUTHILL ELEV. A
Job Reference (optional)
I4601310
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:32 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:43.9
1-3 3-5
2-4
3-6
2-2 4-4
1
2
3
4 5
6
5x8
8x10 8x10 2x4
6-5-8
6-5-8
12-11-0
6-5-8
-0-11-4
0-11-4
6-5-8
6-5-8
12-11-0
6-5-8
13-10-4
0-11-4
0-9-07-2-80-9-012.00 12
Plate Offsets (X,Y): [2:0-3-15,Edge], [4:0-3-15,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.98
0.90
0.11
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.03
-0.07
0.01
0.03
(loc)
4-6
4-6
4
2-6
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 137 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SYP No.1
BOT CHORD 2 X 6 SPF No.2
WEBS 2 X 4 SPF Stud
WEDGE
Left: 2 X 10 SYP No.1, Right: 2 X 10 SYP No.1
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)2=2789/0-3-8, 4=2789/0-3-8
Max Horz 2=215(LC 4)
Max Uplift 2=-610(LC 5), 4=-610(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2764/578, 3-4=-2764/578
BOT CHORD 2-6=-208/1341, 4-6=-208/1341
WEBS 3-6=-49/547
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=610, 4=610.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 936 lb down and 166 lb up at
22-5-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-360(F=-300), 3-5=-360(F=-300), 2-4=-20
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
GR3
Truss Type
ROOF TRUSS
Qty
1
Ply
2
SOUTHILL ELEV. A
Job Reference (optional)
I4601311
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:32 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale: 3/8"=1’
1-3 3-5
2-4
3-6
1
2
3
4
5
6
7x16 MT18H
4x8 4x8 2x4
5-0-0
5-0-0
10-0-0
5-0-0
-0-11-4
0-11-4
5-0-0
5-0-0
10-0-0
5-0-0
10-11-4
0-11-4
0-4-134-6-130-4-1310.00 12
Plate Offsets (X,Y): [2:0-2-2,0-2-0], [4:0-2-2,0-2-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.70
0.34
0.08
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.01
-0.03
0.01
0.01
(loc)
4-6
4-6
4
2-6
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT18H
Weight: 81 lb
GRIP
197/144
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 6 SPF No.2
WEBS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)2=2235/0-3-8, 4=2235/0-3-8
Max Horz 2=-134(LC 3)
Max Uplift 2=-506(LC 5), 4=-506(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2196/443, 3-4=-2196/443
BOT CHORD 2-6=-199/1252, 4-6=-199/1252
WEBS 3-6=-5/379
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=506, 4=506.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 853 lb down and 172 lb up at
49-2-5 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-360(F=-300), 3-5=-360(F=-300), 2-4=-20
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
M1
Truss Type
ROOF TRUSS
Qty
2
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601312
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:32 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:36.1
2-13
1-7
7-8
8-13
6-9
5-10
4-11
3-12
Sheet Front
Full Sheathing
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1
2
3
4
5
6
7
13 12 11 10 9 8
3x6
3x6
2x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
6-0-0
6-0-0
-0-11-4
0-11-4
6-0-0
6-0-0
2-2-35-8-37.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.78
0.44
0.10
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
0.00
-0.00
-0.00
0.00
(loc)
1
1
8
2
l/defl
n/r
n/r
n/a
n/r
L/d
180
120
n/a
120
PLATES
MT20
Weight: 38 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 6-0-0.
(lb) - Max Horz 13=176(LC 5)
Max Uplift All uplift 100 lb or less at joint(s) 13, 8, 10, 11 except 12=-625(LC 5)
Max Grav All reactions 250 lb or less at joint(s) 8, 9, 10, 11, 12 except 13=600(LC 5)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-251/20
NOTES
1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable requires continuous bottom chord bearing.
4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 8, 10, 11
except (jt=lb) 12=625.
8) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
S1
Truss Type
ROOF TRUSS
Qty
3
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601314
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:33 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:57.4
4-5 5-7
2-14
6-13
9-123-15
3-13
3-12
5-12
8-12
8-11
1-4 7-10
13-1412
3
4
5
6
7
8
9 10
15 14 13
12
11
3x6
5x8
3x6
3x8 3x6
3x8
12x12
3x12
1.5x4 6x8
5x12
3x6
1.5x4
7-8-13
7-8-13
16-5-0
8-8-3
22-9-15
6-4-15
30-0-0
7-2-1
-0-11-4
0-11-4
7-8-13
7-8-13
15-0-0
7-3-3
16-5-0
1-5-0
22-9-15
6-4-15
30-0-0
7-2-1
30-11-4
0-11-4
0-4-59-1-50-4-54-5-37.00 12
4.00 12
Plate Offsets (X,Y): [2:0-8-1,0-0-6], [6:0-4-7,Edge], [9:0-4-4,0-1-8], [12:0-6-0,0-3-11]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.72
0.83
0.90
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.27
-0.73
0.56
0.22
(loc)
11-12
11-12
9
11-12
l/defl
>999
>487
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 139 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
1-4,7-10: 2 X 4 SYP No.1
BOT CHORD 2 X 4 SPF No.2 *Except*
9-12: 2 X 4 SYP No.1
WEBS 2 X 4 SPF Stud *Except*
3-13,3-12: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-7-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-13
REACTIONS (lb/size)2=1253/0-3-8, 9=1253/0-3-8
Max Horz 2=279(LC 4)
Max Uplift 2=-250(LC 5), 9=-250(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1926/308, 3-4=-2189/264, 4-5=-2072/302, 5-6=-2684/375, 6-7=-2855/371,
7-8=-2959/335, 8-9=-4113/504
BOT CHORD 2-15=-251/1561, 14-15=-254/1555, 13-14=-254/1555, 12-13=-95/913, 11-12=-331/3627,
9-11=-333/3642
WEBS 3-15=0/360, 3-13=-1722/300, 3-12=-65/1744, 5-12=-166/2103, 8-12=-986/420,
8-11=0/316
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=250, 9=250.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
S2
Truss Type
ROOF TRUSS
Qty
4
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601315
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:33 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:54.2
4-5 5-6
2-11 8-11
5-11
7-11
7-10
3-11
3-12
1-4 6-9
1
2
3
4
5
6
7
8 9
12
11
10
3x6
5x8
3x6
3x12 3x12
6x10
3x6
1.5x4
3x6
1.5x4
7-10-9
7-10-9
15-0-0
7-1-7
22-1-7
7-1-7
30-0-0
7-10-9
-0-11-4
0-11-4
7-10-9
7-10-9
15-0-0
7-1-7
22-1-7
7-1-7
30-0-0
7-10-9
30-11-4
0-11-4
0-4-59-1-50-4-54-10-137.00 12
4.00 12
Plate Offsets (X,Y): [2:0-4-4,0-1-8], [8:0-4-4,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.94
0.87
1.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.34
-0.88
0.77
0.29
(loc)
11
11-12
8
11-12
l/defl
>999
>403
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 123 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
1-4,6-9: 2 X 4 SYP No.1
BOT CHORD 2 X 4 SYP No.1
WEBS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 8-0-2 oc bracing.
WEBS 1 Row at midpt 7-11, 3-11
REACTIONS (lb/size)2=1253/0-3-8, 8=1253/0-3-8
Max Horz 2=279(LC 4)
Max Uplift 2=-250(LC 5), 8=-250(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4059/667, 3-4=-2822/298, 4-5=-2713/337, 5-6=-2713/360, 6-7=-2822/321,
7-8=-4059/488
BOT CHORD 2-12=-604/3591, 11-12=-601/3582, 10-11=-316/3582, 8-10=-319/3591
WEBS 5-11=-171/2313, 7-11=-1096/482, 7-10=0/316, 3-11=-1096/471, 3-12=0/316
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=250, 8=250.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
S2A
Truss Type
ROOF TRUSS
Qty
3
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601316
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:34 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:57.4
4-5
5-7
2-14
13-14
6-11
9-12
3-15
3-14
5-14
6-14
8-13
8-11
1-4
7-10
1 2
3
4
5
6
7
8
9 10
15
14
13
12 11
3x6
5x8
3x6
3x12
4x10
6x10
4x8
3x6
1.5x4
6x10
5x16 MT18H
6x10
7-10-9
7-10-9
15-0-0
7-1-7
20-11-0
5-11-0
30-0-0
9-1-0
-0-11-4
0-11-4
7-10-9
7-10-9
15-0-0
7-1-7
20-11-0
5-11-0
25-2-11
4-3-11
30-0-0
4-9-5
30-11-4
0-11-4
0-4-59-1-50-4-54-10-132-11-37.00 12
4.00 12
Plate Offsets (X,Y): [2:0-4-4,0-1-8], [9:0-0-5,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.95
0.88
0.76
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.35
-0.86
0.73
0.29
(loc)
12
12
9
12
l/defl
>999
>413
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT18H
Weight: 128 lb
GRIP
197/144
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
1-4: 2 X 4 SYP No.1
BOT CHORD 2 X 4 SPF No.2 *Except*
2-14,13-14: 2 X 4 SYP No.1
WEBS 2 X 4 SPF Stud *Except*
5-14,8-13: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 8-2-2 oc bracing. Except:
10-0-0 oc bracing: 11-13
WEBS 1 Row at midpt 3-14, 8-11
REACTIONS (lb/size)2=1264/0-3-8, 9=1276/0-3-8
Max Horz 2=-279(LC 3)
Max Uplift 2=-243(LC 5), 9=-236(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4105/640, 3-4=-2868/271, 4-5=-2758/309, 5-6=-2840/333, 6-7=-3700/382,
7-8=-3773/367, 8-9=-2008/330
BOT CHORD 2-15=-580/3633, 14-15=-578/3625, 13-14=-205/3484, 11-13=-49/1139, 6-13=0/348,
9-11=-177/1675
WEBS 3-15=0/315, 3-14=-1091/472, 5-14=-145/2372, 6-14=-960/351, 8-13=-207/3096,
8-11=-1865/224
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=243, 9=236.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
S3
Truss Type
ROOF TRUSS
Qty
2
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601317
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:34 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale: 3/16"=1’
4-7 7-9
2-16
15-16 8-13
11-14
3-17
5-17
5-16
6-16
7-16
7-15
12-15
10-15
10-121-4
9-11
1 2
3
4
5
6
7
8
9
10
11
17
16
15
14 13 12
3x6
4x8
3x6
4x10
8x8
2x4
2x4
4x8
3x4
1.5x4
3x4
1.5x4
4x8
8x10
3x6
7-10-9
7-10-9
15-0-0
7-1-7
20-11-0
5-11-0
27-2-11
6-3-11
34-0-0
6-9-5
-0-11-4
0-11-4
5-6-1
5-6-1
10-3-0
4-9-0
15-0-0
4-9-0
17-0-0
2-0-0
20-11-0
3-11-0
27-2-11
6-3-11
34-0-0
6-9-5
0-4-510-3-50-4-54-10-132-11-37.00 12
4.00 12
Plate Offsets (X,Y): [2:0-1-2,Edge], [11:Edge,0-0-2], [12:0-3-8,0-2-0], [15:0-2-8,0-3-4], [16:0-4-0,0-3-11]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.82
0.92
0.91
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.37
-0.97
0.69
0.34
(loc)
16-17
16-17
11
16-17
l/defl
>999
>418
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 152 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2 *Except*
2-16: 2 X 4 SYP No.1
WEBS 2 X 4 SPF Stud *Except*
7-16,7-15: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-11-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-0-12 oc bracing. Except:
10-0-0 oc bracing: 13-15
REACTIONS (lb/size)2=1431/0-3-8, 11=1370/0-2-2 (input: 0-1-8)
Max Horz 2=323(LC 4)
Max Uplift 2=-269(LC 5), 11=-214(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4825/868, 3-4=-4520/701, 4-5=-4451/722, 5-6=-3518/462, 6-7=-3449/550,
7-8=-2834/471, 8-9=-2770/374, 9-10=-2873/341, 10-11=-2343/361
BOT CHORD 2-17=-841/4284, 16-17=-556/3835, 15-16=-80/2177, 8-15=-291/217, 11-12=-213/1935
WEBS 5-17=-62/492, 5-16=-678/322, 7-16=-364/2492, 7-15=-352/762, 12-15=-237/2121,
10-15=-46/464, 10-12=-753/166
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) WARNING: Required bearing size at joint(s) 11 greater than input bearing size.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=269, 11=214.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
SGE6
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601318
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:35 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale: 3/16"=1’
4-5
5-7
2-15
14-15 6-13
9-13
3-16 3-15
5-15
6-15
12-14
8-14
8-12
5-17
17-18
19-20
19-21
15-2223-2425-26
27-28
3-29
16-30
31-32
33-34
35-37
36-37
38-40
39-40 41-42
43-44
45-46
46-48
47-48
49-51
50-51 52-53
54-55
56-57 11-58
10-597-9
Sheet Front
Right Option 5-0-0
1 Ply 1/2 BLUE DOW RYLAND 8 FT
1 2
3
4
5
6
7
8
9
16
15
14
13 12
11 10
3x6
6x8
3x6
3x12
8x8
3x8
3x6
4x10
3x6
3x8
5x12
3x6
2x4
2x4 8x8
7-10-9
7-10-9
15-0-0
7-1-7
20-11-0
5-11-0
27-2-11
6-3-11
29-0-0
1-9-5
34-0-0
5-0-0
-0-11-4
0-11-4
8-10-9
8-10-9
14-2-5
5-3-12
17-0-0
2-9-11
20-11-0
3-11-0
27-2-11
6-3-11
34-0-0
6-9-5
0-4-510-3-50-4-54-10-132-11-37.00 12
4.00 12
Plate Offsets (X,Y): [2:0-1-2,0-0-3], [9:0-0-11,Edge], [12:0-3-8,0-1-8], [15:0-4-0,0-3-11], [17:0-1-12,0-0-12], [37:0-1-12,0-0-12], [40:0-1-12,0-0-12], [46:0-2-0,0-2-8], [48:0-1-12
,0-0-12], [51:0-2-0,0-2-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.95
0.96
0.85
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.30
-0.79
0.59
0.27
(loc)
15-16
15-16
9
2-16
l/defl
>999
>459
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 223 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
4-5: 2 X 4 SYP No.1, 1-4: 2 X 4 SYP 2400F 2.0E
BOT CHORD 2 X 4 SPF No.2 *Except*
2-15: 2 X 4 SYP No.1, 9-13: 2 X 4 SYP 2400F 2.0E
WEBS 2 X 4 SPF Stud *Except*
5-15: 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
7-3-6 oc bracing: 2-16
7-6-8 oc bracing: 15-16.
REACTIONS All bearings 4-3-8 except (jt=length) 2=0-3-8.
(lb) - Max Horz 2=323(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 11 except 2=-272(LC 5), 9=-167(LC 6),
10=-212(LC 9)
Max Grav All reactions 250 lb or less at joint(s) 10 except 2=1368(LC 1), 9=999(LC
1), 11=619(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4526/765, 3-4=-3249/414, 4-5=-3116/459, 5-6=-2132/384, 6-7=-2455/391,
7-8=-2556/357, 8-9=-1832/340
BOT CHORD 2-16=-708/4009, 15-16=-740/3913, 14-15=-152/2243, 11-12=-192/1486, 10-11=-192/1486,
9-10=-192/1486
WEBS 3-16=0/394, 3-15=-1032/514, 5-15=-257/2406, 6-15=-457/253, 12-14=-216/1586,
8-14=-24/643, 8-12=-861/190
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 1-4-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except (jt=lb)
2=272, 9=167, 10=212.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
PLYWOOD SHOWN IS NOT PART OF COMPONENT DESIGN.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
ST1
Truss Type
ROOF TRUSS
Qty
10
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601319
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:50:31 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:56.4
4-5
5-7
2-12
6-11
9-11
3-13
5-13 5-12
10-12
8-12
8-10
1-4 7-9
1-4
1
2
3
4
5
6
7
8
9
13
12
11 10
14
4x8
4x6
3x6
3x8
2x4
3x6
3x6
2x4
5x6
6x16
3x6
3x12
2-3-8
2-3-8
9-10-4
7-6-12
17-5-0
7-6-12
23-5-11
6-0-11
30-0-0
6-6-5
30-1-4
0-1-4
-0-11-4
0-11-4
2-3-8
2-3-8
8-7-12
6-4-4
15-0-0
6-4-4
17-5-0
2-5-0
23-5-11
6-0-11
30-1-4
6-7-9
30-11-4
0-10-0
0-6-69-1-50-3-91-0-07.00 12
Plate Offsets (X,Y): [4:0-4-0,Edge], [9:0-5-10,0-2-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.84
0.91
0.67
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.24
-0.68
0.30
0.25
(loc)
2-13
2-13
9
2-13
l/defl
>999
>526
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 162 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
1-4: 2 X 6 SYP DSS
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud *Except*
5-13,5-12: 2 X 4 SPF No.2
OTHERS 2 X 6 SYP DSS
LBR SCAB 1-4 2 X 6 SYP DSS one side
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-9-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-7-15 oc bracing. Except:
1 Row at midpt 6-12
REACTIONS (lb/size)1=1193/0-3-8, 9=1188/0-3-8
Max Horz 1=-276(LC 3)
Max Uplift 1=-196(LC 5), 9=-199(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-543/184, 2-3=-2152/383, 3-14=-2101/464, 4-14=-2086/469, 4-5=-2053/499,
5-6=-1632/395, 6-7=-1592/310, 7-8=-1692/278, 8-9=-1985/331
BOT CHORD 2-13=-337/1912, 12-13=-59/1133, 6-12=-264/168, 9-10=-191/1625
WEBS 3-13=-683/355, 5-13=-299/1024, 5-12=-216/786, 10-12=-184/1565, 8-12=-324/202
NOTES
1) Attached 11-6-9 scab 1 to 4, front face(s) 2 X 6 SYP DSS with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at
1-3-3 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-0-0; starting at 8-11-1 from end at joint 1, nail 2 row(s) at 7" o.c. for 2-6-15.
2) Unbalanced roof live loads have been considered for this design.
3) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=196, 9=199.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
T4
Truss Type
ROOF TRUSS
Qty
7
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601320
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:36 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:52.4
1-4 4-7
2-8
4-8
5-83-8
6-81
2
3
4
5
6
7
8
4x6
5x6
5x12
1.5x4 1.5x4
5x6
10-0-0
10-0-0
20-0-0
10-0-0
-0-11-4
0-11-4
5-1-15
5-1-15
10-0-0
4-10-1
14-10-1
4-10-1
20-0-0
5-1-15
20-11-4
0-11-4
0-4-138-8-130-4-1310.00 12
Plate Offsets (X,Y): [2:0-1-6,Edge], [6:0-1-6,Edge], [8:0-6-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.43
0.78
0.23
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.17
-0.45
0.03
0.05
(loc)
6-8
6-8
6
2-8
l/defl
>999
>521
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 79 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud *Except*
4-8: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-5-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)2=853/0-3-8, 6=853/0-3-8
Max Horz 2=267(LC 4)
Max Uplift 2=-172(LC 5), 6=-172(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-958/192, 3-4=-747/210, 4-5=-747/210, 5-6=-958/192
BOT CHORD 2-8=-121/681, 6-8=-48/681
WEBS 4-8=-111/588, 5-8=-258/226, 3-8=-258/225
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=172, 6=172.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
T4A
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601321
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:36 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:52.4
1-4 4-7
2-8
4-8
5-83-8
6-81
2
3
4
5
6
7
8
4x6
5x6
5x12
1.5x4 1.5x4
5x6
10-0-0
10-0-0
20-0-0
10-0-0
-0-11-4
0-11-4
5-1-15
5-1-15
10-0-0
4-10-1
14-10-1
4-10-1
20-0-0
5-1-15
20-11-4
0-11-4
0-4-138-8-130-4-1310.00 12
Plate Offsets (X,Y): [2:0-1-6,Edge], [6:0-1-6,Edge], [8:0-6-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.43
0.78
0.23
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.17
-0.45
0.03
0.05
(loc)
6-8
6-8
6
2-8
l/defl
>999
>521
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 79 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF Stud *Except*
4-8: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-5-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)2=853/0-3-8, 6=853/0-3-8
Max Horz 2=267(LC 4)
Max Uplift 2=-172(LC 5), 6=-172(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-958/192, 3-4=-747/210, 4-5=-747/210, 5-6=-958/192
BOT CHORD 2-8=-121/681, 6-8=-48/681
WEBS 4-8=-111/588, 5-8=-258/226, 3-8=-258/225
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=172, 6=172.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
T4B
Truss Type
ROOF TRUSS
Qty
4
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601322
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:36 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:54.6
1-4
4-7
1-9
4-8
5-8
4-10
3-10
1-2
6-9
1
2
3
4
5
6 7
10 9 8
4x6
3x6 3x4
1.5x4
3x4
1.5x4
5x6
3x4
3x4
3x6
6-9-5
6-9-5
13-2-11
6-5-6
20-0-0
6-9-5
5-1-15
5-1-15
10-0-0
4-10-1
14-10-1
4-10-1
20-0-0
5-1-15
20-11-4
0-11-4
0-3-88-8-130-4-1310.00 12
Plate Offsets (X,Y): [1:0-2-13,0-0-6], [6:0-6-3,0-0-14]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.30
0.39
0.23
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.05
-0.14
0.02
0.04
(loc)
6-8
6-8
6
6-8
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 87 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
5-8,3-10: 2 X 4 SPF Stud
SLIDER Left 2 X 4 SPF Stud 3-0-14
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-7-7 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1=779/0-3-8, 6=848/0-3-8
Max Horz 1=-278(LC 3)
Max Uplift 1=-117(LC 5), 6=-171(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-961/153, 2-3=-809/175, 3-4=-859/282, 4-5=-882/280, 5-6=-1000/176
BOT CHORD 1-10=-112/669, 9-10=-6/464, 8-9=-6/464, 6-8=-39/689
WEBS 4-8=-162/408, 4-10=-164/375
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=117, 6=171.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
T5
Truss Type
ROOF TRUSS
Qty
6
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601323
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:37 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:67.2
4-5 5-6
2-13
5-12
7-12
7-10
3-12
3-14
1-4 6-9
8-1111-1312
3
4
5
6
7
8 9
14 13 12 11 10
3x6
5x10 MT18H
3x6
3x12
3x6 3x8
3x6
1.5x4
3x6
1.5x4 3x6
3x12
8-8-13
8-8-13
17-0-0
8-3-3
25-3-3
8-3-3
34-0-0
8-8-13
-0-11-4
0-11-4
8-8-13
8-8-13
17-0-0
8-3-3
25-3-3
8-3-3
34-0-0
8-8-13
34-11-4
0-11-4
0-4-510-3-50-4-57.00 12
Plate Offsets (X,Y): [2:1-0-1,0-0-14], [8:1-0-1,0-0-14]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.68
0.89
0.33
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.14
-0.45
0.12
0.16
(loc)
8-10
8-10
8
2-14
l/defl
>999
>891
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT18H
Weight: 139 lb
GRIP
197/144
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
1-4,6-9: 2 X 4 SYP No.1
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
7-10,3-14: 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-5-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-10-2 oc bracing.
WEBS 1 Row at midpt 7-12, 3-12
REACTIONS (lb/size)2=1413/0-3-8, 8=1413/0-3-8
Max Horz 2=315(LC 4)
Max Uplift 2=-276(LC 5), 8=-276(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2197/362, 3-4=-1494/298, 4-5=-1362/343, 5-6=-1362/344, 6-7=-1494/299,
7-8=-2197/362
BOT CHORD 2-14=-301/1786, 13-14=-301/1786, 12-13=-301/1786, 11-12=-158/1786, 10-11=-158/1786,
8-10=-158/1786
WEBS 5-12=-123/902, 7-12=-740/301, 7-10=0/370, 3-12=-740/300, 3-14=0/370
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=276, 8=276.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
T5A
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601324
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:37 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:66.0
3-4 4-5
1-11
4-10
6-10
6-8
2-10
2-12
1-3 5-7
7-99-11
1
2
3
4
5
6
7
12 11 10 9 8
3x6
5x10 MT18H
3x6
3x12
3x6 3x8
3x6
1.5x4
3x6
1.5x4
3x12
3x6
8-8-13
8-8-13
17-0-0
8-3-3
25-3-3
8-3-3
34-0-0
8-8-13
8-8-13
8-8-13
17-0-0
8-3-3
25-3-3
8-3-3
34-0-0
8-8-13
0-4-510-3-50-4-57.00 12
Plate Offsets (X,Y): [1:1-0-1,0-0-14], [7:1-0-1,0-0-14]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.71
0.94
0.33
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.15
-0.48
0.12
0.18
(loc)
7-8
7-8
7
7-8
l/defl
>999
>846
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT18H
Weight: 136 lb
GRIP
197/144
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
1-3,5-7: 2 X 4 SYP No.1
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
6-8,2-12: 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-4-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-4-14 oc bracing.
WEBS 1 Row at midpt 6-10, 2-10
REACTIONS (lb/size)1=1352/0-3-8, 7=1352/Mechanical
Max Horz 1=-312(LC 3)
Max Uplift 1=-226(LC 5), 7=-226(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2212/370, 2-3=-1504/302, 3-4=-1372/347, 4-5=-1372/347, 5-6=-1504/302,
6-7=-2221/372
BOT CHORD 1-12=-321/1800, 11-12=-321/1800, 10-11=-321/1800, 9-10=-197/1812, 8-9=-197/1812,
7-8=-197/1812
WEBS 4-10=-128/915, 6-10=-759/310, 6-8=0/373, 2-10=-747/307, 2-12=0/371
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=226, 7=226.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
T5B
Truss Type
HOWE
Qty
2
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601325
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:38 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:66.6
2-12
4-5 5-6
3-13
5-11
7-9
3-11 7-11
8-1010-12
1-4 6-8
1 2
3
4
5
6
7
8
13 12 11 10 93x12
3x6
3x6
5x10 MT18H
3x6
1.5x4
3x6
3x8 1.5x4
3x6
3x6
3x12
8-8-13
8-8-13
17-0-0
8-3-3
25-3-3
8-3-3
34-0-0
8-8-13
-0-11-4
0-11-4
8-8-13
8-8-13
17-0-0
8-3-3
25-3-3
8-3-3
34-0-0
8-8-13
0-4-510-3-50-4-57.00 12
Plate Offsets (X,Y): [2:1-0-1,0-0-14], [8:1-0-1,0-0-14]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.70
0.92
0.33
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.14
-0.46
0.12
0.18
(loc)
8-9
8-9
8
8-9
l/defl
>999
>875
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT18H
Weight: 137 lb
GRIP
197/144
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2 *Except*
1-4,6-8: 2 X 4 SYP No.1
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
3-13,7-9: 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-4-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-7-15 oc bracing.
WEBS 1 Row at midpt 3-11, 7-11
REACTIONS (lb/size)2=1414/0-3-8, 8=1347/0-3-8
Max Horz 2=323(LC 4)
Max Uplift 2=-277(LC 5), 8=-225(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2199/362, 3-4=-1496/300, 4-5=-1364/345, 5-6=-1364/344, 6-7=-1496/299,
7-8=-2203/369
BOT CHORD 2-13=-313/1788, 12-13=-313/1788, 11-12=-313/1788, 10-11=-194/1793, 9-10=-194/1793,
8-9=-194/1793
WEBS 3-13=0/370, 5-11=-126/905, 7-9=0/371, 3-11=-740/301, 7-11=-746/307
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=277, 8=225.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
T6
Truss Type
ROOF TRUSS
Qty
8
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601326
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:38 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:92.2
4-6
6-7
13-14
11-13
3-15
3-13 5-13
5-12 6-12 8-12
8-10
2-16
2-15
1-4
7-9
9-11
1 2
3
4
5
6
7
8
9
16
15
14
13 12 11 10
3x6
5x8
3x6
4x6
6x8
3x6
3x6
5x6
3x8
4x8
3x6
1.5x4
3x12
6x8 4x8
8-4-5
8-4-5
16-5-2
8-0-13
23-0-0
6-6-14
31-3-3
8-3-3
40-0-0
8-8-13
-0-11-4
0-11-4
8-4-5
8-4-5
16-5-2
8-0-13
23-0-0
6-6-14
31-3-3
8-3-3
40-0-0
8-8-13
2-2-315-7-30-4-55-3-147.00 12
4.00 12
Plate Offsets (X,Y): [2:0-3-8,Edge], [9:0-0-5,Edge], [16:1-0-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.86
0.84
0.60
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.21
-0.62
0.33
0.22
(loc)
13-15
13-15
9
13-15
l/defl
>999
>772
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 184 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SYP No.1 *Except*
6-7,7-9: 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2 *Except*
9-11: 2 X 4 SYP No.1
WEBS 2 X 4 SPF No.2 *Except*
3-15,5-13,8-10: 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-8-5 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-5-5 oc bracing.
WEBS 1 Row at midpt 3-13, 5-12, 8-12
REACTIONS (lb/size)16=1658/0-5-8, 9=1591/Mechanical
Max Horz 16=419(LC 4)
Max Uplift 16=-309(LC 5), 9=-245(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3164/700, 3-4=-3077/632, 4-5=-2948/677, 5-6=-1933/479, 6-7=-1837/491,
7-8=-1971/446, 8-9=-2694/456, 2-16=-1636/472
BOT CHORD 15-16=-479/427, 14-15=-811/2759, 13-14=-794/2795, 12-13=-522/2522, 11-12=-297/2216,
10-11=-297/2216, 9-10=-297/2216
WEBS 3-15=-447/205, 5-13=-208/1038, 5-12=-1300/473, 6-12=-311/1427, 8-12=-755/307,
8-10=0/386, 2-15=-394/2436
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Refer to girder(s) for truss to truss connections.
5) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
16=309, 9=245.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
T7
Truss Type
HOWE
Qty
10
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601327
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:38 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:56.0
4-5 5-6
2-11
5-10
7-10
5-12
3-12
1-4 6-9
8-111
2
3
4
5
6
7
8 9
12 11 10
3x6
4x8
3x6
4x8
3x6 3x4
1.5x4
3x4
1.5x4
4x8
10-1-14
10-1-14
19-10-2
9-8-5
30-0-0
10-1-14
-0-11-4
0-11-4
7-8-13
7-8-13
15-0-0
7-3-3
22-3-3
7-3-3
30-0-0
7-8-13
30-11-4
0-11-4
0-4-59-1-50-4-57.00 12
Plate Offsets (X,Y): [2:0-1-1,Edge], [8:0-1-1,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.70
0.87
0.29
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.24
-0.70
0.08
0.16
(loc)
2-12
2-12
8
2-12
l/defl
>999
>513
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 110 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
WEBS 2 X 4 SPF No.2 *Except*
7-10,3-12: 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-3-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)2=1253/0-3-8, 8=1253/0-3-8
Max Horz 2=-278(LC 3)
Max Uplift 2=-250(LC 5), 8=-250(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1861/330, 3-4=-1664/343, 4-5=-1548/383, 5-6=-1548/383, 6-7=-1664/343,
7-8=-1861/330
BOT CHORD 2-12=-272/1532, 11-12=-51/1022, 10-11=-51/1022, 8-10=-146/1532
WEBS 5-10=-163/674, 7-10=-422/292, 5-12=-163/674, 3-12=-422/292
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=250, 8=250.
5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
V1
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601328
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:39 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:63.3
1-4 4-7
1-9
4-11
3-12
2-13
5-10
6-8
7-9
1
2
3
4
5
6
7
13 12 11 10 9 8
3x4
4x6
3x4
3x6
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
20-7-2
20-7-2
10-3-9
10-3-9
20-7-2
10-3-9
10-3-912.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.22
0.10
0.19
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
7
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 84 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud *Except*
4-11: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-11
REACTIONS All bearings 20-7-2.
(lb) - Max Horz 1=312(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 7 except 1=-105(LC 3), 12=-248(LC 5), 13=-201(LC 5),
10=-248(LC 6), 8=-201(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 7, 11 except 12=340(LC 9), 13=272(LC 1), 10=340(LC 10),
8=272(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-330/179, 6-7=-280/104
WEBS 3-12=-258/298, 5-10=-258/297
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb)
1=105, 12=248, 13=201, 10=248, 8=201.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
V2
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601329
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:39 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:58.3
1-3
3-5
1-7
3-8
2-9 4-6
5-7
1
2
3
4
5
9 8 7 63x8
4x6
3x8
3x6 1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
18-3-2
18-3-2
9-1-9
9-1-9
18-3-2
9-1-9
9-1-912.00 12
Plate Offsets (X,Y): [1:0-6-1,Edge], [5:0-2-9,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.31
0.24
0.15
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 69 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud *Except*
3-8: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-8
REACTIONS All bearings 18-3-2.
(lb) - Max Horz 1=-275(LC 3)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 9=-311(LC 5), 6=-310(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=423(LC 9), 6=423(LC 10)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-9=-299/337, 4-6=-299/336
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
9=311, 6=310.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
V3
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601330
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:39 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:49.2
1-3
3-5
1-5
3-7
2-8 4-6
1
2
3
4
5
8 7 63x4
4x6
3x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
15-11-2
15-11-2
7-11-9
7-11-9
15-11-2
7-11-9
7-11-912.00 12
Plate Offsets (X,Y): [1:0-1-8,0-1-8], [5:0-0-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.20
0.13
0.15
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 59 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud *Except*
3-7: 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 15-11-2.
(lb) - Max Horz 1=239(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-258(LC 5), 6=-258(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=352(LC 9), 6=352(LC 10)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-255/288, 4-6=-255/287
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
8=258, 6=258.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
V4
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601331
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:39 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:42.2
1-3 3-5
1-5
3-7
2-8 4-6
1
2
3
4
5
8 7 63x4
4x6
3x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
13-7-2
13-7-2
6-9-9
6-9-9
13-7-2
6-9-9
6-9-912.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.20
0.11
0.13
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 49 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 13-7-2.
(lb) - Max Horz 1=-202(LC 3)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-218(LC 5), 6=-217(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=298(LC 9), 6=298(LC 10)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-224/254, 4-6=-224/253
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
8=218, 6=217.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
V5
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601332
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:40 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:35.4
1-3 3-5
1-5
3-7
2-8 4-61
2
3
4
5
8 7 63x4
4x6
3x4
1.5x4 1.5x4
1.5x4
1.5x4
1.5x4
11-3-2
11-3-2
5-7-9
5-7-9
11-3-2
5-7-9
5-7-912.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.20
0.11
0.11
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
5
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 38 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 11-3-2.
(lb) - Max Horz 1=166(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-205(LC 5), 6=-205(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=282(LC 9), 6=282(LC 10)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-225/257, 4-6=-225/256
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
8=205, 6=205.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
V6
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601333
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:40 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:29.2
1-2 2-3
1-3
2-4
1
2
3
42x4
4x6
2x4 1.5x4
8-11-2
8-11-2
4-5-9
4-5-9
8-11-2
4-5-9
4-5-912.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.40
0.21
0.06
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 28 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1=201/8-11-2, 3=201/8-11-2, 4=256/8-11-2
Max Horz 1=-129(LC 3)
Max Uplift 1=-64(LC 6), 3=-64(LC 6)
Max Grav 1=201(LC 1), 3=201(LC 1), 4=257(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
V7
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601334
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:40 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:22.2
1-2 2-3
1-3
2-4
1
2
3
4
2x4
4x6
2x4 1.5x4
6-7-2
6-7-2
3-3-9
3-3-9
6-7-2
3-3-9
3-3-912.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.21
0.11
0.03
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 20 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1=144/6-7-2, 3=144/6-7-2, 4=183/6-7-2
Max Horz 1=-92(LC 3)
Max Uplift 1=-46(LC 6), 3=-46(LC 6)
Max Grav 1=144(LC 1), 3=144(LC 1), 4=184(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
Job
Q1421009
Truss
V8
Truss Type
ROOF TRUSS
Qty
1
Ply
1
SOUTHILL ELEV. A
Job Reference (optional)
I4601335
7.140 s Oct 1 2009 MiTek Industries, Inc. Thu Jan 20 08:47:40 2011 Page 1 CARTER-LEE BUILDING COMPONENTS, MOORESVILLE, IN 46158
Scale = 1:9.2
1-2
2-3
3-4
1-4
1
2 3
4
3x4
3x4 3x4
3x4
4-3-2
4-3-2
1-3-12
1-3-12
2-11-6
1-7-10
4-3-2
1-3-12
1-3-121-3-1212.00 12
Plate Offsets (X,Y): [2:0-1-8,Edge], [3:0-1-8,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING
Plates Increase
Lumber Increase
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2006/TPI2002
CSI
TC
BC
WB
(Matrix)
0.07
0.07
0.00
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 10 lb
GRIP
197/144
LUMBER
TOP CHORD 2 X 4 SPF No.2
BOT CHORD 2 X 4 SPF No.2
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-3-2 oc purlins, except
2-0-0 oc purlins: 2-3.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1=142/4-3-2, 4=142/4-3-2
Max Horz 1=-32(LC 3)
Max Uplift 1=-18(LC 5), 4=-18(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone;
cantilever left and right exposed ; Lumber DOL=1.15 plate grip DOL=1.15
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and
referenced standard ANSI/TPI 1.
8) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss TC w/ 2-10d nails.
LOAD CASE(S) Standard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 BEFORE USE.
Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component.
Applicability of design paramenters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown
is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the
erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding
fabrication, quality control, storage, delivery, erection and bracing, consult
ProBuild - East Region
50 Twosome Drive, Suite #5
Moorestown, NJ 08057
ANSI/TPI1 Quality Criteria, DSB-89 and BCSI1 Building Component
available from Truss Plate Institute, 281 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
January 20,2011
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3
-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T, I or Eliminator bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI1.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative T, I, or Eliminator bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2006 MiTekfi All Rights ReservedWEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ER-5243, 9604B,9730, 95-43, 96-31, 9667ANER-487, NER-56195110, 84-32, 96-67, ER-3907, 9432AJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3
-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T, I or Eliminator bracingif indicated.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI1: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBS50 Twosome Drive, Suite #5Moorestown, NJ 08057Pro-Build - East Region