HomeMy WebLinkAboutA200_ FLOOR PLAN Rev.0RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
r
City of Carmel
�un��\i lo•rvalM��'
EXISTIN6 CONSTRUCTION
SHOWN BEVOND �
8" F.V.OPENING 8"
CLEAR WIDTH CLEAR
� � �
� NEW OVERHEAD DOOR
Oj PLAN DETAIL North
Q20� SCALE: 1" = 1'-0"
01
A300
FLOOR PLAN
SCALE: 1/2" = 1'-0"
SEALANTANDBACKER
BOTH SIDES
E%ISTING CONSTRUCTION
SHOWNBEVOND
1'-110" I
� • O' " ' ' \ Di%
SOLID SURFACE COUNTER TOP
RELOCATEDAWMINUM STOREFRONT
SVSTEM. MODIFV AS REpUIRED TO
ACCOMMODATE NEW CONSTRl1CTION.
RELOCATED ACCORDION �OOR ASSEMBLV
EXISTING FIRE DEPARTMENT
CONNECTION TO BE E%TENDED.
(FIELD VERIFV E%ACT
LOCATION). PROVIDE SEALANT
AROUND WALL OPENING.
/
/
GENERALPLAN NOTES
A. ALLWORKSHALLBEPERFORMEOINSTRICTCOMPLIANCEWITHALL
APPLICHBLE CODE$ LAWS AN� OR�INHNCES.
B. ALL�IMENSIONSAREFROMFACEOFSTU�.ORCOWMNCENTERLINE.
HNY �IMENSIONS NOT SHOWN OR �EEMED QUESTIONABLE HRE TO BE
VERiFlED BY ARCNITECT. DO NOT SCALE DRAW WGS.
G CONTqGTRESPEGTNEUTILITYGOMPANYFOREXACTLOCAT10NOF
SERVICESPRIORTOSTARTOFCONSTRUCTION. PROTECTANY
EXISTING SERVICE �URING CONSTRUCTION.
0. REFERTOMEP�RHWINGSPoRHLLMECHANICHLPWMBINGHN�
ELECTRICALRE�UIREMENTS.
E SEEWALLTV�ELEGENOFORWALLCONSTRUCTION.
F PROVIDEFlRETREATEDWOODBLOCKiNGSUFGORTATALLSURFACE
MOUNTED ITEMSAS REp01RED.
G. POORANDFRAMENUMBERSCORRESPONDTOROOMNUMBERS.
WHERE MORE THAN ONE �OOR OCCURS IN A ROOM, A SUFFI%HHS BEEN
ADDEO Q.E 100H). REFER TO �OOR SCHEDULE.
H. CAULKNLLJUNCTURESBETWEEN�IFFERENTMNTERIALS-TYPICALQ.E.
STOREFRONT AN� GYGSUM WALLBOAR�).
i. ALLSTEELSTU�SARETOBEBRAGE�ACCORDWGTO
MANOFACTURERS LIMITING HEIGHT OR L/ OVER 200.
J. ALLMETALSTUDWALLSWHICHEXTENDTODECKSHALLBE
CONSTRUCTE� W ITH A CONTINUOUS SLIP TRHCK AT TOP OF WALL.
TRACK SHALL BE SIZED TO NLLOW PoR MINIMUM �ECK DERECTION OF
�n•-
K EACHCONTRACTORSHALLGROVIpEALLBARRICA�ES,ETG.AS
REpUIRE� BV LAW, CO�E OR ORDINANCE AND AS OTHERWISE
REQUIRE�_
L REMOVEALLTRHSHAN��EBRISFROMTHEJOBSREDAILY.
M. PROVI�EWNLLMOUNTEDFIREEXTINGUISHERSHND/ORCABINETSHS
REQUIRE�BYLOCHLCO�E.
WALL TYPE LEGEND
�/�l� — 3-5/8" X 22 GA. METAL STUDS AT 16" O.C.
WITH 1I2" SHEATHING EACH SIDE AND
SOUND ATTENUATION BLANKETS M EACH
STUD CAVITV. FlNISH TO MATCH EXISTING.
HLL WALL TYPES SHALL BE W i UNLE55 NOTED OTHERW ISE.
FOR WALL HEIGHTS, REFERENCE REFLECTEO CEILWG GLANS.
PROVIDE MOISTURE RESISTANT GYPSUM BOARO AT AL V W ET"
LOCnTION$.
PLAN NOTES
Oi FABRICAWNINGABOVE.
O EXISTINGHCCOR�IONDOORPSSEMBLYANDASSOCIATED
HAR�WARE TO BE RELOCNTEO AS SHOWN. REFERENCE
ELEVATIONS AND SECTIONS FOR AODITIONHL INFORMHTION.
C norusEo.
Oa EXISTINGDOORTOBEREMOVED.WFlLLCAVITYTOALIGNANO
MNTCH EXISTING.
O5 EXISTING FI2E �EPH2TMENT CONNECTION TO BE EXTEN�EO
THROUGH H�JHCENT EXTERIOR COLUMN. REFER TO 3/A400 FOR
MORE MFORMNTION.
O6 EXISTINGAWMINUMSTOREFRONTTOBERELOCATEDASSHOWN.
Oi NEWSERVICECOUNTER.REFERT03IA000PoRMORE
MFORMATION.
Oa EXISTINGRHILINGTOREMHM.
O EXTEND E%ISTING FIRE SPRINKLER SVSTEM INTO NEW ENCLOSEO
TERRHCESPACEASREQUIRED.GENERALCONTRACTORTO
PROVIDE NEW FlRE SPRMKLER HENDS. INTEGRATE NEW SPRINKLER
LWES INTO EXISTING SPRINKLER SYSTEM. FlELO VERIFY EXISTING
CON�ITIONS.
ID EXISTING CONCRETE PHVER FLOORING TO REMAIN. CONTRACTOR
TO PROVIDE AND INSTHLL ARDEX (OR APPROVE� E�UAL)
CONCRETE LEVEL WG SYSTEM TO HCCOMMODATE NEW
CONSTRUCTION ANO FLOOR FlNISH.
NOTE: MAINTAIN 5'-0" MIN. PATHWAY
AROUND PERIMETER OF EXTERIOR
PATIO
DATE: Qrj�Q��2O