HomeMy WebLinkAboutPRIME47_ARCH DWGS WITH FDC NOTESRELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM��_
14300 Clay Terrace Blvd.
Carmel, Indiana 46032
�%�j FIRST FLOOR LIFE SAFETY PLAN
� North SCALE: 3/8" = 1'-0"
USE GROUP: GROUP A-2,
CONSTRUCTION TYPE: II-B, FULLY SPRINKLERED
OWNER: ARCHITECT: CONTRACTOR:
dRCHITEQS FORUM
8555 Nor[M1 River Roaa, Suite 12�
Intlianapolis, Indiana 46240
[P]li].042.8500
�F� 3O.84Z.88]]
CODE REQUIREMENTS SHEETINDEX
ALLWORKUNDERTHISCONTRACTSHALLCOMPLVWITHTHE COVERTITLESHEET/COOEREQUIREMENT$
PROVISIONS OF THE SPECIFICATIONS 8 DRHW INGS AND SHNLL
SATISFYALLAPPLICABLECODES,ORDINHNCES,A.OA.,HNO qRCHITECTURAL
REGULATIONSOFALLGOVERNINGBOOIESINVOLVED. qp01 SITEPLAN
ALL PERMITS AND LICENSES NECESSARV FOR THE PROPER H1�0 DEMOLITION PLANS
EXECUTIONOFTHEWORKSHALLBESECUREDAN�PNI�FOR A�00 FLOORPLHNS
BYTHECONTRACTORINVOLVED. P300 ELEVATIONS
HJ�O WALLSECTIONS
THEFOLLOWINGCODESANDREGl1LATIONSARECURRENTLY P500 DOORSCHE�ULEANDDETqILS
ME200 MECHANICHL PLAN 8 ELECTRICHL PLNN
ADOPTED BY THE STATE OF IN�IANA AT THE TIME A Bl11LDING
PERMIT IS APPLIED FOR'.
BUILOINGCODE INOIANABUILDMGCODE2014
(INTERNATIONAL BUILDING CODE 2012
W ITH INDIANA AMENOMENTS)
MECHANICALCOOE INDIANAMECHANICALCODE2016
QNTERNATIONHL MECHANICAL CODE 2012
W ITH INDIqNN NMENOMENTS)
ELECTRICAL CO�E: INOIANA ELECTRICAL COOE 2009
(NATIONAL ELECTRICAL CODE 2008
W ITH INDIHNA AMENOMENTS)
PWMBWG CODE'. INOIANA PWMBWG COOE 2012
QIMFORM PW MBING CODE 2006)
FlRECODE' INDIANAFlRECO�E20t4
QNTERNATIONHL FIRE GOOE 2012
W ITH INDIHNA NMENOMENTS)
ENERGY CODE INDIANH ENERGV CONSERVATION CODE 2010
(HSHRAE 90.1-200] WITH INOIANAAMENDMENTS)
FUELGASCOOE INOIANAFUELGASCO�E2014
QNTERNATIONHL FUEL GAS CODE 2012
W ITH INDIHNA NMENOMENTS)
ACCESSIBILI71' CODE'. INDIANH BUILDWG CODE, CHAPTER 11
Icc�ANsIA„"1998ACCE5518LEANDUSAeLE LIFE SAFETY LEGEND
BUILDINGS AND FHQLITIES
EP ELECTRICAL PnNEL LOCATION
CODE SUMMARY ex exi*-eui�oiNcsrnia�ocanon
GROSSSQUAREFOOTAGE: FE FiaeexrwcuisHea�ocnnoN
ovERnu auaowc sF - uNKNowN �
EXIT SIGNAGE LOCATION
E%ISTWGTENANTSPFGE- 94005F
TOTALEXISTING - 90005F � EMERGENCVLIGHTING
TOTAL RENOVATION SQUARE FOOTAGE: PROJECT LOCATION
FIRSTFLOOR - 410SF
TOTAL - 410SF
CONSTRUCTION TYPE: �
II-B EXISTING FULLV SPRWKLERED
OCCUPANCY: �aouan-zaEsrnuRnNr
OCCUPANT LOA� CALCOLATION (PER TABLE 1004.1):
TOTAL ASSEMBLY FLOOR AREA '. 410 SF / 15 = 2] �
Tolal = 2] � �
EGRESS:
REpUIRED PROVIDEO
TENANT 2]OCCUPANTSX.15 405" 3fi"
�
Z
W
�
W
�
O
�
�
�
�
Z
Q
Z
� W
• • �
J C
W �
� �
� �
Q ,
V °�°
� O
W �
� �
�_ �
DATE: Qrj�Q��2O
L J
OUT�
02 ENLARGED SITE PLAN
Q0�1 SCALE: 3116" = 1'-0" North
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
r
City of Carmel
�un��\i lo•rvalM��'
DATE: Qrj�Q��2O
>
� �� � / A
0
PLAN NOTES
Oi NEW CONSTRUCTION'.ENCLOSEDTERRACE
O FABRICAWNWGCANOPY.
O EXISTINGEMERIORPATIOTOREMAIN.
O EXTEND EMERIOR RAILING TO REMAW.
OEXISTINGENTRYTOREMHM.
�
I
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
r
City of Carmel
�un��\i lo•rvalM��'
DATE: Qrj�Q��2O
DEMOLITION PLAN
SCALE: 1/2" = 1'-0"
GENERAL DEMOLITION NOTES
A. COOR�INATE EXTENT OF DEMOLITION WORK WITH ALL NEW
CONSTRUCTION. PS INDICHTEO IN CONTRNCT �OCUMENTS.
B. THESEDEMOLITIONNOTESREPRESENTSURVEVEDSPACESBEFORE
DEMOLITION WOHK. LOCATION OF CASEWORK, COl1NTER5, ETC.
W ITHIN THESE OOCIIMENT$ MFV NOT BE COMPLETELV FCCURNTE.
C. FlELDVERIFYEXACTSIZESHN�LOCATIONOFALLEXISTINGWORK
PRIORTOCONSTRUQION. CONTAQTHEARCHRECTINTHEEVENT
OF CONFLICTS.
D. CONTRHCTORSHHLLPROVIDEALLTEMPORARVPHRTITIONSAND
�OORS AS DEEMED NECESSARY BY ARCHITECT AND OW NER TO
AVOID MIGRATION OF OUST INTO ADJOINING AND OCCl1PIED AREAS.
E. MHKEHLLDEMOLITIONCLEANANDCOMPLETEHNOINAMHNNER
SUITHBLE TO HCCEPT NEW FlNISHES ANDIOR SURFHCES.
F. qLL DEMOLITION ITEMS SHNLL BE CONSIDERE� PROPERTV OF THE
OWNER UNTIL VERIFICATION HAS BEEN MAOE AS TO REMS TO BE
RETAINED, PRIOR TO REMOVHL FROM THE SITE. HLL REMS NOT TO
BE RETAMED SHALL BE REMOVED FROM THE SITE BV THE
CONTRACTOR.
G. WHENDEMOLITIONCHUSESOREXPOSESDAMAGETOEXISTWG
SLAB. FLOOR, WHLL OR CEILING SURFACES WHICH W ILL REMHIN
EXPOSEO IN THE FlNISHED WORK, THE CONTRHCTOR SHALL REPAIR
AND LEVEL Sl1CH CONDITIONS HS REpUIRED.
H. REMOVEEXISTINGFLOOR,WALLANDCEILWGFlNISHES WHERE
INDICATED. PROTECTALLEXISTMG INTERIORFlNISHESTOREMHIN.
L WHEREHNVE%ISTINGPIPINGOROUCRNORNINFLOORS.WALLSOR
CEILINGS IS TO BE REMOVED OR RELOCHTED, FILL IN PENETRATION
OPENINGS FLUSH W ITH HNO OF THE SAME MHTERIHLS.
J. REMOVPL OF ANV PSBESTOS IS THE RESPONSIBILITY OF THE
OWNER. NOTIFVTHEARCHITECTIFSUCHMATERIALISDISCOVERED
DURWG DEMOLITION OPER4TION5.
K. DASHE�LWESIN�ICATETOREMOVEWALLS,�OORS,FRAMESAND
NSSOQqTEDITEMSCOMPLETE
L CONTRHCTORTOCOOROINATEEXTENTOFDEMOLITIONWORK
REQUIRED TO MATCH FINISH FLOOR ELEVHTION ON EHCH SI�E OF
WALL TO BE DEMOLISHED.
DEMOLITION LEGEND
-----� DASHEOLWEINOICATESTOREMOVEEXISTMG
WALL CONSTRl1CTION, DOOR 8 WINDOW SYSTEM,
CASEWORK, FlXTURES, HNO RAILING COMPLETE.
DEMOLITION PLAN NOTES
Oi E%ISTING CONCRETE PAVER FLOORING TO REMHIN. CONTRHCTOR
TO PROVI�E HND INSTALL HROEX (OR HPPROVED EQUPL)
CONCRETELEVELINGSVSTEMTOACCOMMODATENEW
CONSTRUCTION AND FlNISHES.
O REMOVE E%ISTING DOOR, FRAME, AND HARDWARE COMPLETE.
VERIFV OWNER'S INTENT OF ITEMS TO BE RETHINE�, PRIOR TO
REMOVAL FROM THE SITE.
O EHISTING RAILWG TO BE REMOVEO TO ACCOMMODNTE NEW PATIO
LAVOUT. VERIFY OWNER'S IMENT OF ITEMS TO BE RETHWEO,
PRIOR TO REMOVAL FROM THE SITE.
O EXISTINGFIREOEPARTMENTCONNECTIONTOBERELOCATED.
O5 EXISTING ACCORDION �OOR ASSEMBLV HN� NSSOqqTED
HARDWARE TO BE RELOCATED. PROTECT DURING ALL PHHSES OF
CONSTRUCTION. REFERENCE FLOOR PLAN FOR HODITIONHL
WPoRMATION.
O EXISTINGAWMINl1MSTOHEFNONT5V5TEMTOBERELOCATEO.
PROTECT �URING HLL PHASES OF CONSTRUCTION. REFERENCE
FLOOR PLAN FOR N��ITIONAL WFORMATION.
EXISTIN6 CONSTRUCTION
SHOWN BEVOND �
8" F.V.OPENING 8"
CLEAR WIDTH CLEAR
� � �
� NEW OVERHEAD DOOR
Oj PLAN DETAIL North
Q20� SCALE: 1" = 1'-0"
rlKt YKV I tl.l IUIV rUl. I.VIVIVtI.I IVIV NV I tJ
1. 4" GROOVED SCHEDULE 10 GALVANIZED PIPE, COUPLINGS & FITTINGS
2. THE ELEVATION OF CENTER LINE OF PIPE AND FIRE DEPARTMENT
CONNECTION IS APPROXIMATELY 30" A.F.F. (MAINTAIN CURRENT
ELEVATION)
3. EXISTING 4"X5"" STORZ TYPE FIRE DEPARTMENT CONNECTION TO BE
RELOCATED TO NEW EXTERIOR WALL AS SHOWN.
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
r
City of Carmel
�un��\i lo•rvalM��'
DATE: Qrj�Q��2O
01
A300
FLOOR PLAN
SCALE: 1/2" = 1'-0"
SEALANTANDBACKER
BOTH SIDES
E%ISTING CONSTRUCTION
SHOWNBEVOND
1'-110" I
� • O' " ' ' \ Di%
SOLID SURFACE COUNTER TOP
RELOCATEDAWMINUM STOREFRONT
SVSTEM. MODIFV AS REpUIRED TO
ACCOMMODATE NEW CONSTRl1CTION.
RELOCATED ACCORDION �OOR ASSEMBLV
EXISTING FIRE DEPARTMENT
CONNECTION TO BE E%TENDED.
(FIELD VERIFV E%ACT
LOCATION). PROVIDE SEALANT
AROUND WALL OPENING.
/
/
GENERALPLAN NOTES
A. ALLWORKSHALLBEPERFORMEOINSTRICTCOMPLIANCEWITHALL
APPLICHBLE CODE$ LAWS AN� OR�INHNCES.
B. ALL�IMENSIONSAREFROMFACEOFSTU�.ORCOWMNCENTERLINE.
HNY �IMENSIONS NOT SHOWN OR �EEMED QUESTIONABLE HRE TO BE
VERiFlED BY ARCNITECT. DO NOT SCALE DRAW WGS.
G CONTqGTRESPEGTNEUTILITYGOMPANYFOREXACTLOCAT10NOF
SERVICESPRIORTOSTARTOFCONSTRUCTION. PROTECTANY
EXISTING SERVICE �URING CONSTRUCTION.
0. REFERTOMEP�RHWINGSPoRHLLMECHANICHLPWMBINGHN�
ELECTRICALRE�UIREMENTS.
E SEEWALLTV�ELEGENOFORWALLCONSTRUCTION.
F PROVIDEFlRETREATEDWOODBLOCKiNGSUFGORTATALLSURFACE
MOUNTED ITEMSAS REp01RED.
G. POORANDFRAMENUMBERSCORRESPONDTOROOMNUMBERS.
WHERE MORE THAN ONE �OOR OCCURS IN A ROOM, A SUFFI%HHS BEEN
ADDEO Q.E 100H). REFER TO �OOR SCHEDULE.
H. CAULKNLLJUNCTURESBETWEEN�IFFERENTMNTERIALS-TYPICALQ.E.
STOREFRONT AN� GYGSUM WALLBOAR�).
i. ALLSTEELSTU�SARETOBEBRAGE�ACCORDWGTO
MANOFACTURERS LIMITING HEIGHT OR L/ OVER 200.
J. ALLMETALSTUDWALLSWHICHEXTENDTODECKSHALLBE
CONSTRUCTE� W ITH A CONTINUOUS SLIP TRHCK AT TOP OF WALL.
TRACK SHALL BE SIZED TO NLLOW PoR MINIMUM �ECK DERECTION OF
�n•-
K EACHCONTRACTORSHALLGROVIpEALLBARRICA�ES,ETG.AS
REpUIRE� BV LAW, CO�E OR ORDINANCE AND AS OTHERWISE
REQUIRE�_
L REMOVEALLTRHSHAN��EBRISFROMTHEJOBSREDAILY.
M. PROVI�EWNLLMOUNTEDFIREEXTINGUISHERSHND/ORCABINETSHS
REQUIRE�BYLOCHLCO�E.
WALL TYPE LEGEND
�/�l� — 3-5/8" X 22 GA. METAL STUDS AT 16" O.C.
WITH 1I2" SHEATHING EACH SIDE AND
SOUND ATTENUATION BLANKETS M EACH
STUD CAVITV. FlNISH TO MATCH EXISTING.
HLL WALL TYPES SHALL BE W i UNLE55 NOTED OTHERW ISE.
FOR WALL HEIGHTS, REFERENCE REFLECTEO CEILWG GLANS.
PROVIDE MOISTURE RESISTANT GYPSUM BOARO AT AL V W ET"
LOCnTION$.
PLAN NOTES
Oi FABRICAWNINGABOVE.
O EXISTINGHCCOR�IONDOORPSSEMBLYANDASSOCIATED
HAR�WARE TO BE RELOCNTEO AS SHOWN. REFERENCE
ELEVATIONS AND SECTIONS FOR AODITIONHL INFORMHTION.
C norusEo.
Oa EXISTINGDOORTOBEREMOVED.WFlLLCAVITYTOALIGNANO
MNTCH EXISTING.
O5 EXISTING FI2E �EPH2TMENT CONNECTION TO BE EXTEN�EO
THROUGH H�JHCENT EXTERIOR COLUMN. REFER TO 3/A400 FOR
MORE MFORMNTION.
O6 EXISTINGAWMINUMSTOREFRONTTOBERELOCATEDASSHOWN.
Oi NEWSERVICECOUNTER.REFERT03IA000PoRMORE
MFORMATION.
Oa EXISTINGRHILINGTOREMHM.
O EXTEND E%ISTING FIRE SPRINKLER SVSTEM INTO NEW ENCLOSEO
TERRHCESPACEASREQUIRED.GENERALCONTRACTORTO
PROVIDE NEW FlRE SPRMKLER HENDS. INTEGRATE NEW SPRINKLER
LWES INTO EXISTING SPRINKLER SYSTEM. FlELO VERIFY EXISTING
CON�ITIONS.
ID EXISTING CONCRETE PHVER FLOORING TO REMAIN. CONTRACTOR
TO PROVIDE AND INSTHLL ARDEX (OR APPROVE� E�UAL)
CONCRETE LEVEL WG SYSTEM TO HCCOMMODATE NEW
CONSTRUCTION ANO FLOOR FlNISH.
NOTE: MAINTAIN 5'-0" MIN. PATHWAY
AROUND PERIMETER OF EXTERIOR
PATIO
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
r
City of Carmel
�un��\i lo•rvalM��'
DATE: Qrj�Q��2O
EXISTING CONSTRUCTION
NEW LOCATION OF FIRE
DEPARTMENTCONNECTION.
(FlELD VERIFV EXACT LOCATION)
�Z EXTERIOR ELEVATION
Q30� SCALE: 1/2" = 1'-0"
EXISTING C(
NEW LOC/
DEPARTMENT
(FIELD VERIFV EXA�
ONSTRUCTION
iTUD FRAMING
fION
JG
TCH EXISTING
STRUCTION
:E COUNTER
VIDE
REQUIRED.
O� SERVICE COUNTER ELEVATION
Q30� SCALE: 1/2" = 1'-0"
EXISTING CONSTRUCTION
TO REMAIN
h BOTTOM OF EXISTING CEILING
� + 1 fi'-2" AEF. (F.V)
SOLID SURFACE COUNTER
TOP
EXISTING FIRE DEPARTMENT
CONNECTION TO BE
EXTENDED. (FIELD VERIFY
EXACT LOCATION)
EXISTING CONSTRUCTION
TO REMAIN
RELEA5E0 FOR CONSTRIICTI�N a�� sECTioN
Su6jec��ocompliancewithallregula�ions :ALE:$/4"=1'-�"
of S�a�e antl Local Codes
r
City of Carmel
�un��\i lo•rvalM��'
DATE: Qrj�Q��2O
�
�i
�
BLOCKING
WALL CONSTRUCTION:
-3-5/8" METAL STUD FRAMING
-5/8" GPYSUM. PAINTED.
EXISTING CONCRETE PAVER
FLOORING TO RECEIVE
ARDEX (OR APPROVED
EQUAL)CONCRETE FLOOR
LEVELING SYSTEM. PREPARE
SURFACE TO ACCEPT NEW
FINISHES.
� RNISH FLOOR
+ p" AF.F.
EXISTING CONSTRUCTION
TO REMAIN
�
ING
EXISTIN FIF
CONNE TIOI
EXTEND D.I
EXACT L CP
EXISTIN CC
TO REM IN
h BOTTOM OF EXISTING CEILING
4 +1g'-2"AF.E(RV)
1/ALL CONSTRUCTION:
1 1/2" EIFS
AIR INFILTRATION BARRIER,
�ULLY TAPED
1/2" SHEATHWG
3 5/8" METAL STUD FRAMING
R-19 BATT INSULATION
VAPOR BARRIER
5/8 GYPSUM WALLBOARD
FINISH TO MATCH EXISTING)
!EW WALL CONSTRUCTION
"O ALIGN WITH FACE OF
XISTING.
>OLID SURFACE COUNTER
-OP
;ABINET. PROVIDE
tLOCKING AS REQUIRED.
:XISTING CONCRETE PAVER
�LOORWG TO RECEIVE
\RDEX (OR APPROVED
:QUAL) CONCRETE FLOOR
.EVELING SYSTEM.
'REPARE SURFACE TO
\CCEPT NEW FINISHES.
FINISH FLOOR
+0" AEF.
02 WALL SECTION
Q4�0 SCALE: 3/4" = 1'-0"
EXISTING CONSTRUCTION
TO REMAIN
SEALANT AND BACKER
ROD BOTH SIDES
2x WOOD BLOCKING
WALL CONSTRUCTION:-
-1 1/2" EIFS
-AIR INFILTRATION
BARRIER,FULLY TAPED
-1/2" SHEATHING
-3 5/8" METAL STUD
FRAMING
-R-19 BATT INSULATION
-VAPOR BARRIER
-5/8 GYPSUM
WALLBOARD (FINISH TO
MATCH EXISTWG)
RELOCATED EXISTING -
STOREFRONT ASSEMBLY
EXISTING CONSTRUCTION
SHOWNBEYOND
RELOCATED EXISTING
ACCORDION DOOR
ASSEMBLY
EXISTING CONCRETE
PAVER FLOORING TO
RECEIVE ARDEX (OR
APPROVED EQUAL)
CONCRETE FLOOR
LEVELING SYSTEM.
PREPARE SURFACE TO
ACCEPT NEW FINISHES
NEW GRADE BEAM
�
�
26
�FABRIC AWNING
�FLASHING
'-p SEALANT AND BACKER ROD
> BOTH SIDES
0
w
�
a
>
0
w
LL
EXISTING CONCRETE
SIDEWALK
h FINISH FLOOR
. . p . .. 4 +0"AF.F.
O� WALL SECTION
Q4�� SCALE: 3/4" = 1'-0"
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
r
City of Carmel
�un��\i lo•rvalM��'
DATE: Qrj�Q��2O
DOOR AND HARDWARE SCHEDULE GENERAL HARDWARE NOTES
N0. ROOM SIZE DOOR FRAME DETAIL UL HARDWARE REMARKS
NAME RATING TYPE A. HARDWARE SUPPLIER TO VERIFY HARDWARE SCHEDULE W/OWNER.
MAT'L ELEV. GLASS LOUV. MAT'L ELEV. HEAD JAMB SILL g, ALL DIMENSIONS ARE NOMINAL. GLAZING CONTRACTOR TO SUBMIT SHOP DRAWINGS
101A TERRACE EXISTINGF.V. AL - T - AL H1/A500 Ji/A500 51/A500 - - EXISTINGACCORDIONDOORASSEMBLY FORREVIEWBYARCHITECT.
101 B TERRACE 6'-10" x 8'�0" F.V. AL - T - AL � - 3/A200 - - - OVERHEAD DOOR
HARDWARE LEGEND
AL ALUMINUM
Door Schedule Notes: �� GLASS
HM HOLLOW METAL
1. ALL NEW DOORS ARE TO MATCH EXISTING FINISH P PLASTIC
PL PLASTIC LAMINATE
5 STEEL
T TEMPERED
ALTERNATE BID wo w000
101A TERRACE (2)3'-0"X8'-0" AL D1 T - AL F2 H1 J1 S1 - 1 STOREFRONT HARDWARE SCHEDULE
1016 TERRACE (2�3'-0" X 8'�0" AL Di T - AL F2 Hi J1 Si - 1 STOREFRONT PROVIDE HARDWARE IN SETS ACCORDING TO THE
DOOR TYPES FRAME TYPES STANDARD DOOR LOCATION STANDARD FRAME FOLLOWING SCHEDULE:
PROVIDE BEST LOCKING SYSTEM OR APPROVED EQUAL.
DOORWIDTH ROUGHOPENING ROUGHOPENING HARDWARE FINISH TO BE US26D.
�� p„ ooRwio 2, 2. DOORWIDTH 2„ ALL DOORS TO RECEIVE 3 HINGES AND WALL OR DOOR
� STOP UNLESS NOTED OTHERWISE.
TO DOOR 4.
z �, �, CLEARANCE ^' � HARDWARE SET 1(BY ALUMINUM DOOR MANUFACTURER)
" �� �� 4" MINIMUM MANUFACTURERS STANDARD INCLUDING:
x wa c� w� c�
o � o � o � 3 BALL BEARING BUTT HINGES
� g � g 18" MINIMUM 2. 1 SURFACE MOUNTED DOOR CLOSER
CLEARANCE 1 PANIC EXIT DEVICE
TO DOOR 1 THRESHOLD
1 SET WEATHER STRIPPING
D 1 F� FZ 12" MINIMUM ry A 1 DOOR SWEEP
ALUMINUM FRAME CLEARANCE 1 KEYED CYLINDER BY HARDWARE SUPPLIER
ALUMINUM FRAME WITH PAINTED
FULL LIGHT REFERENCE SCHEDULE TO DOOR
114" CLEAR
TEMPERE� GLASS
ANODRE� AW MINUM
GLAZINGSYSTEM —
MEDIUM STILE ALUMINUM
ENTRANCE DOOR
DOORSWEEP
ALUM.THRESHOLDTO MATCH LJ
WIDTH OF STOREFRONT MAX.
3I8"HIGH �
� .° 9 .�,. Q e .
�
�
a, �
s� SILL C� STOREFRONT
A5.0 Scale: 3" = 1'-0"
H,,,, HEAD/JAMB C� STOREFRONT
A5.0 Scale: 3" = 1'-0"
RELEA5E0 FOR CONSTRIlCTION
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
r
City of Carmel
�un��\i lo•rvalM��'
�
L J
ELECTRICAL PLAN //Nortn
SCALE: 1/2•• = 1•_0•• �
�
�� �
MECHANICAL PLAN
SCALE: 1/2" = 1'-0"
GENERALNOTES
A. ALLWORKSHALLBEPERFORFIEDMSTRIQCOMPLIANCEWITHALL
APPLICABLE CODE, LAWS, AND ORDINANCES.
B. THIS WORK SHALL WQUDE ALL HEATING, VENTILATING AND AIR
CON�ITIONING SYSTEMS REQUIRED AS INDICATED ON THE �RAW INGS, AND
MCLUDES BUT IS NOT LIMRED TO HEATER, FANS, FILTEPS, CONTINUOUS
DURS, DAMVERS, GRILLES, REGISTERS, DIFFWERS, �UQ INSULATIOq AND
ALLACCESSORY REMS REQWRED FOR COMGLETE AND OPERABLE SVSTEMS.
G ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST
A��ITION OF THE INDIANA MECHANICAL CODE.
D. ALL DUCTWORK SHALL BE CONSTROQED AND INSTALLED IN
ACCOR�ANCE WITH SMACNA STANDAR�S FOR THE ttPE OF �UCTWORK TO
BE USED. ALL JOINTS SHALL BE SEALED WITH APPROVE� SEALANL EXPOSEO
DUQWORK SEAMS AN� SEALING SHALL BE SMOOTH WITH NO E%CESS
MATERIAL ON SEAM115 AND JOINTS.
E. E%POSEDSUPPLY�UCTWORKSHALLBEROUNDSHEETMEfALOFTHE
PROVER GAUGE FOR THE DURSRE aN� AIR VOLUME HANDLE� WITH 2"
E%TERIOR INSUL4TION WITH VAPOR JACKET BRACED AS REQUIFED FOR THE
DUR SIZE AND AIR VOLUME HANDLE�.
E CONCEALEDSECONDARVSUPGLYDUCTWORKORRUNOUTDUQSSHALLBE
ROUND SHEET METAL EXTERNALLV INSULATED EX<EPT FOR THE LAST 5
FEET. THE DIFFUSfR CONNfQION SHALL 6E MADE WITH INSOLATED
FLE%IBLE DOQ. NO FLE%16LE DUQ RUNS SHALL EXCEED 6 FEET. ALL ROUND
SECONDARY OOCTS SHALL 6E SENRELY SUPPORTED WITHOUT SAGS Oft
KINKS AND TO HAVE LOCKING QUADRANTTAKEOFF DAMPER CONNEQION AT
MAIN TRUCN.
4 ALL WCTWOFK SHALL BE SENkELV HONG AN� FAAENE� TO PkIMAkY AN�
SECON�AFV 4FOQOkAL MEM8EP5 ONLY.
H. PkOVI�E ALL NECE55ARY ISOLATORS, CONNEQORS, �MIPERS AN� VOWME
CONTkOLS FOF A COMPLEfE ANO CONTkOLLABLE MECHA W CAL SYAEM.
L GRILLES AN� OIFFOSEkS SHALL BE AS NOTE� ON PLAN. PkOVI�E ALL
NECESSAkY SPIN�INS, TAKEOFFS, �AMPEkS� SUPPOFTS� CONNERORS� AN�
MISG ITEMS FOR A COMPLETf INSTPLLATION.
1. STpRTUP PND B4LPNCING SHALL BE COMPLETED IMMf�IATELY BEFORE
OCNP4NCY OF THE FqCILItt.
HVAC PLAN NOTES
O VkOVIpE AND INSTALL NEW CARRIER FB4CNF p3010 NW 208V SINGLE PHASE
ELEQRIC (OR APPROVE� EQUAL) FAN COIL UNIT WITH PROGRAMMABLE
THERMOSTAT. CONNEQ TO E%ISTWG ELEQRICAL PANEL PROVIDE OE�ICATE�
❑RCUIT AS REQUIREO.
O NEW THEkMOSTAT LOCATION.
O PROVIDE AN� INSTALL NEW CARRIER Z4ABB330AOW3 2.5 TON �OR APPROVED
EQOAL� AIR HANDLING UNIT. UNIT TO BE MOUNTED ABOVE EXISTING
VESTIBULE. VROVIDE ADDITIONAL STRURURAL SUPPORTS AS REQUIPED FOR
SENRE MOUNTIN4CONNEQ TO EXISTING ELERWCAL PANEL. PROVIDE
OE�ICATEO QkC01T AS kEQ01kE�.
HVAC SYMBOL LEGEND
rvEw oucr wonx
�NEW GANAN¢E� SPIRAL DOCTWORH
v—�
�� F�Exia�E oucT
� z.iHvacoirrusea
O THEPMOSTAT
GENERAL ELECTRICAL NOTES
A. ALL WORK SHALL BE PERFORMED IN STRIQ COMFLIANCE WITH ALL NATIONAL,
STATf, AND LOCAL APPLICABLf CODfS, lAWS AND OR�INANCfS.
B. ALL 40 VOLT, 20 AM11P CIRCOITS OVfR 60' M LfNGTH SHALL Bf #10 AWG,
OVfR 95' SHALL Bf #8, OVfR 145' SHALL Bf k6.
G CONDOITSYSTfM115HALLBffMTABOVfMAMLfVfLCfILING.CONTRAQOR
MAY OSf HOSPITAL GRADf MC CABLf FOR BRANCH CIRNITS ABOVf
ACCESSIBLE CEILING. ALL HOMERUNS TO THE PANEL SHALL BE EMT CONOOIT.
D. ALLELEQICALDEVICECOLORSSHALLMATCHEXISTMGCOLOR.
E CONTRAQORSHALLCOORDINATEWITHALLOTHERTRADESTOAVOID
CONFLIQS OF SPACE.
E CONTRAQORSHALLCOORDINATETHEE%AQLOCATIONOFALLOEVICES
WITH ALLTRADES PRIORTO ROOGH�IN. E%AQ LOCATION TO BE DETERMMED
IN THE FlELD.
6 CONTkAQORSHALLC00R�INATEWITHTHEMECHAWCALAN�PWMBING
CONTkAQORS FOR E%AQ LOCATIONS OF EQUIPMENT PRIOR TO ROUGH�IN.
H. SHAREONEUTRAL$SHALLNOTBEPEkMITfE�.
I. "H' CLIPS ARE NOTACCEPrABLE FOk JUNQION BO%SUPPOkTING.
J. RECEPTACLESSHALLBEAMA%IMUMOFHB'AEF.TOTHECENTEROF
�EVICE, UNLESS OTHERWISE NOTE�.
K. SWRCHESSHALLBEAMA%IMUM�48"A.F.F.TOTHETOVOFDENCE,UNLE55
OTHERWISE NOTE�.
L. WHERE DENCES ARE INSTALLED IN FIRE WALLS, ALL BOXES SHALL BE RATED
AND SEALED FOR INSTALLATION IN FIRE WALL.
ELECTRICAL POWER PLAN NOTES
O NEW ELEQRICAL RECEPTAQE TO BE CONNERE� TO E%ISTING ELERRICAL
PANEL CONTRAQOR TO FlEL� VERIFY EXAQ LOCATION.
O NfW TELfVI510N LO<ATION. PROVI�E ALL REQUIRfD CONNEQIONS.
MOUNT RECEPTAQE AT �84" AEE COOR�INATE FlNAL LOCATION WITH
OWNER.
Oi VROVIDE NEW CEILING MOONTED FAN WITH INTEGRATED LIGHT FIXTURE.
COORDINATE FlNAL LOCATION WITH OWNER. CONNECT TO E%ISTING
ELEQRICAL PANEL.
Oa NO ELEQRiCqL WORN iN TrviS AREA.
'ION FDC CONNECTION NOTES
IEDULE 10 GALVANIZED PIPE, COUPLINGS & FITTINGS
�F CENTER LINE OF PIPE AND FIRE DEPARTMENT
PROXIMATELY 30" A.F.F. (MAINTAIN CURRENT
ELEVATION)
3. EXISTING 4"X5"" STORZ TYPE FIRE DEPARTMENT CONNECTION TO BE
RELOCATED TO NEW EXTERIOR WALL AS SHOWN.
DATE: Qrj�Q��2O