Loading...
HomeMy WebLinkAboutCOP 001 - Plot Plan�ig'!�-�c.�� h�— /�- Z-t� Z� "BASE HOUSE STANDARD �EATURES" IVIODEL: CASTLETON 9' FULL 8A5EMENT - ONE WINDOW WELL 3 CAR SIDET ENTF2Y GARAGE 5'X7' DECK BRICK WRAP "SELECTEDFEATURES" ELEV NC3M - LEFT HAND COVEREDPORCH (2) WIN�OW WElLS * Conc Flatwork Sq. Ft = ±2,421 Public Walk Sq Ft = ±211 Sod Sq Yds = ±545 Seeding Sq Ft = ±6,218 *{Dri�e, Apron, 3' Walk, Patio, Stoops) (PORCH NOT INCLUDED) �oT # � ±16,037 SF PAD 893.3 PER PLAN MFFE 893.9 PER PLAN MFPG 893.9 PER PLA�! MLAG 893.4 P�R PLAN Note: il I �1 �� Front Yard - 25' Side Yard - 4' 5Y Aggregate - 19' Min. 5iruciure separation - 1 D' Min Rear Yard - 25' 3' Ser�ice walk io street may need modified due to water meter pii locaiion. Note: J �� , �,,,"� ��.,,, ,.-`'������ � ��°o "'. . � ��C����,15TER�4'���;� � No. ; S0557 : STATE OF : . . ��. �'. !NDIA�P'� �:� .,� q�y'�' ��.�0 ��. ''�., . _S lJ .++`� The lowest elevation to have gravity sanitary sewer service must be more than one (1) foot above the lowest top of casting ele�ation of either the first upstream or downstream manhole on the main line sewer to which the connection is made. Flood Hazard Nate: Lot Number 1 lies within Flood Hazard Zone "X" (UNSHADED)per the scaled location on the Flood Insurance Rate IVlaps for Hamilton County, Indiana (Community Panel 18057CO245G, dated November i 9, 2014). Note: This document has baen prepared for the benefit of the parties indicated hereon, for the express use of obtaining a residential building pe�mit. This document has been prepared and based upon the construction documents, record drawings, and additional information prepared for this development by others. This document is not based upon a field survey and Coor Consulting does not warrant the accuracy or completaness of this information. O c�o��a��o�g � O��c� �c�r��oc�c��� D ) c� o r� p o r� ��� o� 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA {888) 593-2667 (765) 345-5943 FAX#: (765} 345-5692 ❑ATF- [14113120 JOB #2{}18-115_001 REVISIONS: Contractor should verify site specific information depicted hereon with the appraved construction pfans for this development in regards to sidewalk and handicap ramp placement, widths, and canstruction. Contractor should verify site specific infarrctation in regards to erosion control placement and materials. Also, Contractar should reference Architectural plans for foundatian orientation and dimensions. Unless otherwise stated hereon, no fnformation pertafning to but not The contractorlowner shauld verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the infarmation contained hereon shouid be immediately reported ta COOR Consulting & Land 5ervices, Gorp.; failure to do so would result in the contractorlowners assumption of liability. Note: Unless otherwise stated hereon, no information pertaining to but not limited to, fluctuating water tables elevations, soil types, and conditions within the building areas of this development haue been pra�ided andlor referenced on said documents. With the excavation of the praposed structure foundations, certain care and obsenrations shouid be made in regard to such conditions as soil types and fluctuating water tables. During the excavation process shauld any unsuifabla soils or ground water be witnessed, fhe builder shall he immediately notified for further exam3nation and consultation. At the builders discretion, additional construction techniques may be necessary to aileviate future problems. COPPER RUN PL4T PLAN �.c. �, SLIDE 932 Prepared For: IN57R. #k2019042699 �Fu lt�e � � Gar. FFE � 893.9 1st Flr FFE = 895.7 TOW = 894.7 Bsmt FFE = 885.9 Drive Slope = ±2.7% LOT#'[ 93060 CHENILLE DRIVE CARMEL, IN 46074 Pulte Homes of Indiana �::: : \::::� :� ... ���ar�c��l �lo��� �c��OC�a � " �0' Contractor should verify sump pii location with Field Manager. Note: 4 y� � � Min. � � � � � il� Min. *�' . �} ?, � ? Min.