Loading...
HomeMy WebLinkAbout1 Copper Run LAYOUTFrame Bay In FieldHTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26Use This Dimension For Girder PlacementHTU26HTU26HTU26HTU26HTU26TOE NAIL2x4 Ledger2x4 LedgerHTU26HTU26HTU26HTU26TG01T01T02T03T04T05T06T07T08TG02T09AT09T10T11T12T14T15T16T17TG03TG04GE01T18T18T18J02J02J02J02J02J02J02J02J02J02J02J03J03J03J03J03J03J04TG05J05TG06J07J09GE02GE06GE03GE08TG07GE07T20J11J10J08J 1 3 A J 1 2 AJ13J12 V01V02V03V04GE09V05V06V07V08V09V10V11V13PB02PB03T13(2)M01(3)M02(4)PB01(11)J01(5)J06(15)T21(4)T22(2)21-01-0011-02-003-00-0012-09-0012-10-0815-01-0820-00-0048-00-0048-00-0012-06-033-10-081-11-002-00-002-00-002-00-002-00-002-00-002-00-002-00-004-00-002-00-002-00-002-00-002-00-001-10-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-01-002-00-002-00-002-00-002-00-002-00-002-00-002-00-003-00-002-00-002-00-002-00-002-00-002-00-002-00-001-09-082-00-002-00-002-00-002-00-002-00-0056-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-06-008-00-007-11-003-00-002-00-002-00-001-10-08 2-00-003-00-002-00-001-09-002-00-001-03-082-00-002-00-002-00-002-00-002-00-002-00-002-00-001-10-082-00-002-00-002-00-002-00-001-04-002-10-002-00-008-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-10-0859-00-0048-00-002-00-002-00-002-00-00HANGER SCHEDULESYM QTY DESCRIPTION SYM QTY DESCRIPTIONA- H2.5A A- LTHJRB- HGUS26-2 B- LUS24C - HGUS26-2-2 C - LUS26-2D - HGUS28-2 D - LUS410E- HTU26 E- MUS26F - LTHUL F - THA422-2PULTE HOMES1COPPERRUN-CASTLETONNC3MAddress:Salesperson:Scale:Job Number: B20001079 Drawn by:Katherine SelvaDate: 04/15/2020 Lot Number: 1 Designed by:Katherine SelvaTRUSS PLACEMENT GUIDENOTES:DO NOT CUT OR MODIFY TRUSSES.TRUSSES ARE SPACED 24" ON CENTER UNLESS NOTED OTHERWISE.REFER TO THE INDIVIDUAL TRUSS DESIGN DRAWINGS FOR THE LOCATION OF LATERALBRACING AND MULTY-PLY CONNECTION REQUIREMENTS.PER ANSI TPI 1-2002 THE TRUSS ENGINEER IS RESPONSIBLE FOR TRUSS TO TRUSSCONECTIONS AND TRUSS PLY TO PLY CONNECTIONS. THIS PLACEMENT PLANRECOMMENDS TRUSS TO BEARING CONNECTIONS AND TRUSS TO BEAM CONNECTIONSWHICH SHALL BE REVIEWED BY THE BUILDING DESIGNER TO RESOLVE ALL ROOF FORCESADEQUATELY TO THE FOUNDATION.ALL TRUSS TIES TO BE INSTALLED BEFOREO.S.B. IS APPLIED TO ROOFDO NOT CUT TRUSSES! TRUSSES CUT BY ANY TRADE / SUB-CONTRACTOR WITHOUT FIRST RECEIVING PERMISSION ANDDIRECTION FROMPROBuild, (317) 834 5380, SHALL BE CONTRACTOR / BUILDER RESPONSIBILITY! NO EXCEPTIONS3D VIEW 13D VIEW 2CUSTOMER:JOB NAME & MODEL: