HomeMy WebLinkAboutAN-4.2N. INSTALL WOODWORK PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS.
SHIM AS REQUIRED WITH CONCEALED SHIMS. INSTALL TO A TOLERANCE OF 1/8 INCH IN
8'-0" FOR PWMB HND LEVEL (MCWDING TOPS) AND WRH NO VARIATIONS M
FLUSHNE55 OF A�]OINING SURFACES.
0. SCRBE FND Clfr WOODWORK TO FIT FDJOMING WORK NND REFIMSH NT SURFACES
OR REFFIR DNMAGED FMISH AT NT.
P. FIRERETARDANT TREATED WOOD: HANDLE, STORE, AND MSTALL FIRERETARDANT
TREATE� WOOD TO COMPLV WITH RECOMMENDATIONS OF CHEMICAL TRFATMENT
MANUFAQURER INCLUDIN6 THOSE FOR ADHESIVES WHERE THEY ARE USED TO INSTFLL
WOODWORK.
Q. NNCHOR WOODWORK TO ANCHORS OR BLOCIaNG BUILT IN OR DIRECTLY NTTACHED TO
SUBSTRATES. SECURE TO GROUNDS, STRIPPIN6 AND BLOCKIN6 WITH COUNTERSUNK,
CONCEALED FASTENERS AND BLIND NAILIN6 AS REQUIRED FOR A COMPLEfE
INSTALL4TION. EXCEPT WHERE GREFINISHED MATCHING FNSrENER HENDS ARE
REQUIRED, USE FINE FIMSHMG NHIL$ FOR EXPOSED NANNG, COUNTERSUNK AND
FILLED FLUSH WITH WOO�WORK AND MATCHIN6 FINAL FINISH WHERE TRANSPARENT
FIMSH 6 MDICFTED.
R. NLTERNATESPKIESANDFlN6HESGRNDESTOBESUBMITTEDFORCOSTSAVINGSAS
NPPROPRIATE.
DIVISION 7- THERMAL & MOISTURE PROTECTION
07200 INSULATION
H. SOUND ATTENUATING FIRE BATTS: USG "THERMHFIBER" SAF6. 251bs/[aft.
B. POUR-IN-PLACE UREfHANE FONM: FOMO PRODUCTS "HANDI FOAM" QUICK NRE FOAM
F161].
C. SPRAY-FOAM INSUL4TION: DOW INDUSTRIES "STVROFOAM" SPRNY POLYl1REfHANE
wnn.
D. THERMAL BARRIER FILM COATING: Flame Seal-Tb -(NQUEOUS BFSED RESIN) SPRNY
NPPLIED FIRE PROTECTIVE INTUMESCENT COATING
0)2J0 FIRESTOPPING
N. PENETRATIONS THROUGH FLOORS AND FIRE-R4TED PARTI1lON5 (SHFFf WALLS, STNIR
ENCLOSURES, ETCJ SHALL BE COMPLETELV FIRESTOPPED TO MAINTAIN CODE REQUIRED
FIRE-RATiN6.
1. HILTI SINGLE COMPONENT SILICONE EL45rOMER SENLNNT, ONE COMPONENT
CERNMIC BASE PURV FRLER, OR TWO COMPONENT FOAM, AS REQUIRED BY
LOCATION OFPENETRATION.
2. USG "THERMAFlBER FlRE/SMOKE-STOP SYSTEM". 2-t/2" UNFACED "THERMAFlBER"
SAFING FWCTION FR MTO OPEMNG AROUND PIPE, TOPPED WITH A T' LAYER OF
"THERMAFlBER SMOKE SENL" COMPOUND (AT WFLLS, NPPLV 2" OF COMPOUND ON
BOTH 9DE5 OF WALL). UL 165, 2 HND 3 HOUR FIRE RHTMG.
B. SUBMR PRODUQ DATA FOR REVIEW.
0]900 IOIPoTSEALANTS
1e1�_\�JAGI�1[UP4AM��_1:b11�[S�]CIiASQI}�IP'c1�.'la_1C1P1�
B. AT WINDOW AND DOOR FRAMES QNTERIOR) AND CASEWORK: WHITE IATEX CAULK
(PAINTABLE).
G AT 6LA55 STOPS (WINDOWS AND DOORS): CLEAR SILICONE SFALANT.
D. AT KITCHEN RXTURES: MILDEW RESISTANT SILICONE SEALANT. COLOR TO
MATCHGROUT.
E. NON-HARDENING ACOUSTICAL SEALANT AND INSULATION AT ALL PENETRATIONS
THROUGH ACOUSTICAL PARTITIONS.
DIVISION 7- DOORS AND WINDOWS
08200 WOODDOORS
H. SOLID CORE AND VENEER IS TO MATCH HRCHIIECT'S SPECIFICHTION - PROVIDE SAMPLE.
B. TOLERANCES:
1. WARP SHALL NOT BE CONSIDERED N DEFEQ UNLE55 if E%CEEDS 1/91NCH IN THE
PLANE OF THE DOOR ITSELF. FOR �OORS 1-3/4INCH OR THICKER, WARP SHALL NOT
E%CEED 1/4INCH IN DOORS 3'-6" x]'-0" OR SMALLER, NOR SHALL R EXCEED 1/4 MCH
IN DOORS 3'-6" x]'-0" SEQION OF LARGER DOORS. WARP IS ANY DISTORTION W
THE DOOR ITSELF AND DOES NOT REFER TO THE RELATIONSHIP OF THE DOOR TO
THE FRFME ]FMB, OR AWACENT DOORS. WARP IS MEASURED BV PLNCING F
STRAIGHT EDGE ON CONCAVE FACE AND DETERMMMG THE MAXIMUM DISTNNCE
FROM STRAIGHT ED6E TO THE DOOR FACE.
C. HANDLING, FINISHING, AND INSTALLATION INSfRUCRONS:
1. STORE DOORS FLAT ON F LEVEL SURFFCE IN DRV, WELL VENTILATED BUILDING.
COVER DOORS TO KEEP QEAN AND AVOID DISCOLORATION WITH AN OPAQUE
COVERM6 WHICH DOES NOT PERMIT LIGHT TO PENETRATE COVERING MUST ALLOW
AIR CIRCULATION. IF DOORS ARE TO BE SfORED MORE THAN A WEEK ALL EDGES
MUST BE SENLED,
2 DOORS SHOl1LD NOT BE SUB]ECTED TO EXTREMES OF HEAT, DRY OR HUMID
CONDITION. RELATNE HUMIDITY SHOULD NOT BE LE55 THAN 30% OR 6REATER
THAN 60 % .
3. HNNDLE WITH CLENN GLOVES AND DO NOT DRA6 DOOR NCRO55 ONE FNOTHER OR
NCRO55 OTHER SURFACES.
4. THE UTNTV OR STRULTURAL STRENGTH OF THE DOORS MUST NOT BE IMPAIRED M
THE FITTING OF THE DOOR, THE APPLICATION OF HARDWARE, OR CUTTING AND
NLiERING FOR LI6HT5, LOWERS, PANELS OR FNV OTHER SPECIAL DETNILS.
5. USE THREE HINGES FOR DOORS ]'-6" IN HEIGHT OR LE55, FOUR HINGES ON DOORS
OVER 7'-6". ALLOWING A FITTIN6 VARIANCE OF 1/B INCH AT EACH SI�E AND AT THE
TOP,
6. CAREFULLY SEAL NLL EDGES IMMEDIATELY ARER FITTING MCW DING AREAS ROl1TED
FOR CONCEALED CLOSURES AND OTHER HARDWARE.
7. BEFORE FINISHING, THE FINISHER MUST �0 N THOROUGH FINAL SANDING OVER ALL
SURFACES USMG l50 GRIT SANDPNPER, DEPENDIN6 ON ALL SPECIES, AND M
COMl1NQI0N WITH A HAND BLOCK OR ORBITAL SANDER IN ORDER TO REMOVE ALL
SNFFS, HFNDLIN6 MARKS, SCRFTCHES, RA6ED GRAM, BURNISHES AND EFFECTS OF
EXPOSURE TO MOISTURE THAT MAY OCCUR DURING HANDLING, UNLOADING AND
STORFGE.
8. IMMEDIATELY ARER FRTING AND BEFORE HANGMG, THE ENTIRE DOOR INCWDING
TOP AND BOTTOM ED6E5 MUST RECENE TWO COATS OF GOOD QUALITV LACQUER.
9. SOME WOODS, PARTINLARLY OAK, CONTNIN CHEMIULS WHICH REAQ WITH IRON
OR SOME FlMSHING MNTERIFLS. DO NOT USE SrEEL WOOL ON OAK DOORS.
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
�
�u't1�\i �JYv;�IRA�� .
DATE: Qrj�Q�j�20
10.D0 NOT USE SfEEL WOOL OR WATER BASED FINISHES ON FIRE RATED DOORS.
11.DOORS PREFlMSHED ATTHE FNQORV SHOULD BE CHECKED FGFINST FPPROVED
FINISH SAMPLE PRIOR TO HANGING (INSfALIATION OF PREFIMSHED DOORS SHALL
CONSTifUTEACCEPTANCE).
D. MAMTENANCE: A COMPLETE AND CONTINUOUS FMISH M114 BE MAMTAMED ON NLL
SURFACES OF THE DOOR.
E. CONDITIONS:
1. DOORS SHOULD BE MFNUFACRIRED ACCORDING TO WARNOCK-HERSEY'S FND U.L.'S
E%ALTING SPEQFICATIONS AND CARRY THEIR CERTIFICATION IABELS.
2. 90 MMUTE DOORS MUST CARRV 0.L CLASSIFICATION AND c0.L
08700 HARDWARE
1. SEE HARDWARE SCHEDULE FOR HARDWARE SPEQFIG4TION.
08800 GLAZING
H. IMERIOR GIA55 DOORS:
1. GLA55 AT DOORS AND INTERIOR WINDOWS. SAFEfY GLA55 (LAMINATED OR
TEMPERED).
L CLEAR FLOAT: %a " THICKNE55, TYPE I(TR4NSPARENT GLA55, FL4T), CLA55 1,
QUHLITY q3.
B. INTERIOR GLA55 PANELS:
1. CLENR: 3/8" CLEAR LFMMNTED OR TEMPERED SAFEfY GV55. TYPE I(TRANSPARENT
GLA55, FIAT), CLA55 1, QUALITV q3.
2. GLAZING CHANNELS: CONCFALED AT 9LL HND HFAD. E%TRUDED ALUMINUM FOR 3/8"
THICK GIA55. SETTING BLOCKS AND GASKETS. FIMSH: CLEAR ANODIZED, SATIN
LUSTRE. SUBMIT CATALOG CUT AND MATERIAL SAMPLE FOR REVIEW.
DIVISION 9 - FINISHES
09000 GENERAL
H. SEE FINISHES SCHEDULE AND FINISHES LEGEND FOR FlNISH MHTERIALS.
B. INSTALLATION MATERIALS AND PROCEDURES SHALL CONFORM STRICTLV WITH
MANUFAQURERS MSTRUQIONS AND RECOMMENDATIONS.
C. CONTRNCrOR SHNLL PERFORM ALL MANUFNCNRER'S RECOMMENDED INCfIAL
MAMTENANCE PROCEDURES FOR ALL NEW FIMSHES.
D. PRIOR TO INSTALLATION OF FINISHES, CONTRACTOR SHALL REVIEW AND TEST NLL
SUBSTRFTES FOR COMPLINNCE WITH MNNUFFCTURER'S RECOMMENDFTIONS. WHEN AN
EXISRNG SUBSrRATE DOES NOT COMPLY WIfH MANUFFQURER'S RECOMMENDNTIONS,
THE CONTRACTOR SHALL SUBMR A SCOPE HND COST PROPOSNL FOR THE WORK
REQUIRED TO BRING THE SUBSfRATE INTO COMPLINNCE, PRIOR TO THE SfART OF
CONSTRUGTION.
09250 GYPSUM BOARD
H. DRVWALL CONSTRUQION, MHTERIAL AND WORKMHNSHIP PER ANSI A9].1 AND
UNITED STATES GYPSUM CO. SPECIFICATfONS WITH CORNER BFADS,'7" BEADS AND
"L" BFADS FND ALL NCCESSORIES. THREE SKIM COATS OF COMPOUND ON NLL JOINTS,
FASTENERS AND METAL FLANGES. TEMPERATURE IN WORK SPACES SHALL BE
MAMTAINED ABOVE 65 DEGREES F. BOTH DAY AND NI6HT, BEGMNW6 24 HOURS
BEFORE THE START OF INSTALLATION. OBTAIN ALL COMPONENTS AND MATERIAL OF
THE DRYWFLL SYSTEM FROM A SINGLE MANUFNQURER.
B. DRVWALL ASTM C36, 5/8" THICKNE55, FIRECODE TVPE'C', TAPERED ED6E5, REGULAR
NND WFTER RE56TNNT (GREEN) GR4DE5. SAG-RE95TFNT TYPE FOR CERING SURFNCES.
[ABUSE RESISTnNT GYPSUM FBER PANELS:
UNITED STATES GYPSUM CO. "FIBEROCK
VM".] SCREW (1%6) FASTENERS; WALLS @ 8" O.C., CEILING @]" O.C.
C TAPABLE MEfAI 7' eEAD: USG SERIES 200, OR EQUAL
D. RIGID VINYL 7' BEAD: USG RP SERIES, OR EQUAL FOR USE AT FLUMMUM MULLIONS
AND TRIM.
E. GYPSUM BOARD FMISH: SMOOTH
F. WATER RESIS�ANT (6REEN) 6RADE 6W8 AT BATHROOMS (ALL WALLS) AND AT PLUMeING
WALLS (BOTH 9DE5), e.g. AT SINKS, DRINKING FOUNTNINS, etc.
G. HT ACOUSTICHL PARTITIONS, SEf THE END OF THE INNER IAYER OF GVPSUM BOARD IN
A CONTINUOUS HFAW BEAD OF ACOU54CAL SFALANT SEf AD]ACENT TO THE STUD
TRNCK RUNNER, AT TOP AND BOTTOM OF THE PNRTCfION, ON FACH SIDE OF THE STUDS.
09300 CERAMICTILE
A. INSTALLATION SHALL COMPLY WITH THE FOLLOWIN6 TILE COUNQL OF AMERIU (TCA)
MEfHODS AND WIfH THE RECOMMENDATIONS OF THE TILE SUPPLIERS AND
MANUFACTURERS. SEE FINISH SCHEDULE FOR M4ALLNTION METHOD.
1. THIN SET: F113
2. MUD SET: Flll (CONCRETE SL4B)
3. BOND COAT (FLOORS HND WHLLS): LATEX-PORTLAND CEMENT MORTAR. (ANSI
N118.9).
4. GROUT: (WALLS) LATEX-PORTLAND CEMENT, 1p6" JOINT THICKNE55, COLOR:
WHIfE
5. SILICONE SFAIANT: MILDEW-RE56TANT, COLOR TO MATCH GROIfr. INSTNLL
NROUND PLUMBMG FIXTl1RE5, SLFTE SADDLES, EfC.
09500 ACOUSTICALTILECEILING
N. LEVEL CEILING TO WITHIN 1/B" IN 10' IN BOTH DIRECTIONS. SCRIBE AND NT PANELS
TO FIT FCCURNTELY.
B. SUBMR SHMPLE PER BNC GUIDLINES. SUBMR ALTERNATE FOR SOUND ATTENUATION.
G ACOUSTIUL TILE CEILIN6 6RID TO BE SUPPORTED WITH No. 12 5WG GALVANIZED
STEEL WIRE, TWISGTfED TO STEEL ]OISTS OR NPPROVED HANGER QIPS. SPACING: 98"
o.c MNXIMUM ON MAM Rl1NNER5, AD]ACENT TO CRO55 TEE IMERSELTIONS. ONE
HAN6ER WIRE TO OCNR AT ALL FOUR CORNERS OF LI6HT FIXTURES, AT MID SPAN OF
CROSS TEES AD]ACENT TO 4' LI6HT FIXTUftES AND AIR DUQ OUTLEfS, AND AD]ACENT
TO FACH MAIN RUNNER SPLICE INSTALLATION AND MATERIALS SHALL CONFORM
TO ASTM C 636-96. INSTALLATION AND MATERIALS IN AREA REpUIRING SEISMIC
RESTRAINT (IBC SEISMIC DESIGN CATEGORV C(SEISMIC ZONES 0-2) OR
CATEGORIES D, E OR F(SEISMIC ZONES 3& 4)) SHALL CONFORM TO ASTM E
580-00
D. PROVIDE ONE (i) FULL CARTON OF EACH TYPE OF ACOUSTICAL CBLWG
TILE (EXCLUDIN6 METAL MFlLL PANELS), IN ADDITION TO ANV REMAINDER
CARTONS FROM THE INSTALLATION, TO THE OWNER AS "ATTIC STOCK". STORE
ON THE SITE, AS DIRECTED BV THE OWNER.
09650RESILIENT FLOORING AND ACCESSORIES
A. SHEET FLOORING: INSTALL OVER EXISTING CONCRETE. INSTALLATION
MATERIALS AND PROCEDURES SHALL CONFORM STRICTLV WITH
MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS FLASH PATCH TO
PROVIDE A SMOOTH, FLAT AND LEVEL SUBSTRATE USING
AROEX #SD-F "FEATHER FINISH" PORTLAND CEMENT BASE� PATCHING
MATERIALS
(NOT GVPSUM BASED PATCH WG MATERIALS). SUBSTRATE TO BE DRV, CLEAN
AN� FREE OF FOREIGN MATERIALS AN� ADHESNE RESI W E PRIOR TO
INSTALLATION. MAXIMUM SLOPE OF 1I8" PER 4 FEET.
1. CONTRACTORSHALLPERFORMINITIALMAINTENANCEQNITIALCLEANING
THEN CONSOLIDATION TREATMENT) PROCEDURES AFTER FLOORING
INSTALLATION AS RECOMMENDED BV MANUFACTURER. TILE GRAINS MUST BE
ALTERNATEDi80DE6REES.ADHESIVE'.MANUFACTURER'SRECOMMENDED
AOHESNE, WSTALLEO WITH RECOMMENDED NOTCHED TROWEL.
2. SCRBE AND CUT SHEET FLOORING TO BUTT TIGHTLV TO VERTICAL
SURFACES. INSTALL SHEET FLOORING SQUARE WITH ROOM.
B. RUBBER BFSE: 9" HIGH X 1/8" GNUGE THICK. STRFIGHT OR COVE BNSE, AS MDICFTED.
SUBMIT SAMPLES FOR REVIEW. USE ROLLED GOODS TO MINIMIZE SFAM ]OINTS. NO
MORE THAN 1 SEAM PER WALL, 1T MINIMUM BETWEEN SEAMS IF MORE THAN 1 SEAM
REQUIRED. PRE-FORMED CORNERS. NO ]OINTTO BE WITHIN ONE FOOT OF AN OUTSIDE
CORNER.
C VINYL REDl1QNG STRIP: SUBMIT SAMPLE FOR REVIEW. LOCATE REDUCMG STRIP AT
HIN6E 9DE OF ]AMB. PROVIDE AT ALL TRANSITIONS FROM NEW VCT TO E%ISTW6 VCT
OR EXPOSED CONCRETE, (UNLE55 NOTED OTHERWISE) AND NT TR4NSITIONS FROM
CARPEf TO VCT (WHERE NOTED). SIMILAR TO
]OHNSONITE "REOUCER" MODEL #RRS-C AT VQ; "ED6E GUARD" MODEL #E.G.-G or H
(9ZE AS REQUIRED BY CARPET) AT CARPET. COLOR TO MATCH BHSE (U.N.O.)
D. WSTALLATION:
1. ADHESIVES: USE ONLY LOW ODOR, LOW VOC, NON-TOXIC, WFTER-BASED
ADHE9VE5. SUBMIT CATALOG NTS WITH VOC RATINGS FOR REVIEW. ACCEPrABLE
PRODUQS INCW DE BUT ARE NOT LIMITED T0:
a. NMERICFN FORMUL4TING antl MFNl1FACRIRING (AFM) "SFFECOAT 3 in 1".
�ia.�si.eseo
b. CHICA60 ADHESIVE PRODUQS COMPANY "CHAPCO SAFE-SEf". 600.621.@20
c ROBERTS 800.923.996]
E VENTIL4TION: PROVIDE MA%IMUM MECHANICAL VENTIIATION WITH MN%IMUM Ol1T5IDE
AIR DURING INSfALLATION AND FOR A PERIOD OF R HOURS AFfER COMPLETION.
F PROVIDE ONE (1) FULL CNRTON OF EACH COLOR AND TVPE OF VCr FND VINYL BFSE, IN
ADDRION TO REMAINDER CARTONS FROM THE MSTALIATION, TO THE OWNER
AS "ATTIC STOCK". STORE ON THE 9TE, A$ DIRECTED BY THE OWNER.
09680 CARPET
A. GLUE DOWN INSTALLATION OVER EXISTING CONCREfE. FLASH PFTCH FLOOR AS
REQUIRED FOR SMOOTH INSTALLATION.
6. SEAM$ AT ROLL GOODS ARE TO BE SEFLED WITH SEAM SFALER.
C. CARPET, FDHESIVES AND PNDS ARE TO CARRY THE INDOOR AIR QUALCfV (IAQ) LFBEL
FROM THE CARPET AND RUG INSTRUTE (CRI).
D. INS�ALLATION:
L MSTALLNTION BY MANUFNQURER'S CERTIFIED DENLER. PROVIDE MANl1FACRIRER'S
WHRR4NTEE FOR MATERIAL AND INSTNLLATION.
2. ADHESIVES: USE ONLY LOW ODOR, LOW VOC, NON-TOXIC, WFTER-BASED
ADHESIVES. SUBMIT CATALOG NTS WITH VOC RFTINGS FOR REVIEW. ACCEPrABLE
PRODUQS INCLUDE BUT ARE NOT LIMCfED T0:
a. AMERICAN FORMUTATIN6 and MANUFACTURIN6 (AFM) "SAFECOAT ALMI6HTY"
]14.]81.6860
b. CHICH60 ADHESNE PRODUCTS COMPANV "CHAPCO SAFE-SET". 800b21A220
c BENTLEY"HEFLTHGUNRD".818333.9585
3. VENTIL4TION: PROVIDE MW(IMUM MECHAMG4L VENTILNTION WITH MA%IMUM
OUT9DE NIR DURING INSTNLLATION HND FOR N PERIOD OF ]2 HOURS ARER
COMPLEf10N.
4. COMPLY WITH MANUFAQURER'S RECOMMENDATIONS FOR SEAM LOCATIONS AND
DIREQION OF CFRPEf; MNINTAIN UNIWRMITV OF CNRPEf DIRECTION AND LAY OF
PILE AT DOORS, CENTER SEHMS 11NDER DOORS. DO NOT PLACE SEAMS IN DIRELTION
OF TRAFFIC.
4. COMPLY WITH MANUFAQURER'S RECOMMENDATIONS FOR DIRECIION OF CARPEf
TILE; MAINTAIN UMFORMITY OF G4RPET DIRERION AND LAY OF PILE (UNLE55
NOTED OTHERWISE).
5. EXTEND CARPEf UNDER OPEN-BOTTOMED OBSTRUCI]ONS NND UNDER REMOVABLE
FIANGES AND FURNISMNGS.
E. MAINTENANCE PROGRAM: MANUFAQURER'S CERTIFIED DEALER TO SUBMIT A PROPOSAL
FOR N VFARLV CNRPET MNINTENANCE PROGRAM.
UlI•ZI�IM:1:1 J i� 11 � i
A. CARPET TILE MSTALIATION OVER E%ISTMG CONCRETE OR VCT FLOORING. Fl1LL
COVERAGE WITH RELEASABLE ADHE9VE. FLASH PHTCH FLOOR AS REQUIRED FqR
SMOOTH INSTALLATfON.
B. CARPET, FDHESNES AND PNDS ARE TO CARRY THE MDOOR AIR QUALITY (IAQ) IABEL
FROM THE CNRPET FND RUG INSrCfUTE (CRI).
C. INSrALLNTION:
L M4ALIATION BY MANUFHCTURER'S CERTIFIED DENLER. PROVIDE MANl1FACTURER'S
WARRANTEE FOR MATERIAL AND tNSTnLLATt01V.
2. ADHESIVES: USE ONLY LOW ODOR, LOW VOC, NON-TOXiC, WATER-BASED
ADHESIVES. SUBMIT CATALOG CUTS WITH VOC RFTINGS FOR REVIEW. NCCEPrABLE
PRODUQS INCLUDE BUT ARE NOT LIMITED T0:
a. AMERICAN FORMULFTIIV6 and MANUFFGTURIN6 (AFM) "SNFECOFT NLMI6HTY"
]14J81.686
b. CHIU60 ADHESNE PRODUQS COMPANV "CHAPCO SAFE-SET". 800.621.0220
c BENTLEY "HEFLTHGl1NRD". 818333.9585
3. VENTIL4TION: PROVIDE MA%IMUM MECHANICAL VENTIIATION WITH MA%IMUM
OUT9DE HIR DURING INSTHLLATION AND FOR H PERIOD OF J2 HOURS AFfER
COMPLEfION.
DIVISION 26 - ELECTRICAL
4. COMPLV WITH MANUFAQURER'S RECOMMENDATIONS FOR DIREGTION OF CARPEf 260000 GENERAL
TILE; MHINTAW UNIFORMITV OF CHRPET DIREQION AND LAV OF PILE (UNLE55 q, q�� ELEQRICAL WORK TO BE PERFORMED BY A LICENSED ELECrRICINN, WHO SHFLL
NOTED OTHERWISE). qRRANGE FOR AND OBTAIN FLL REQUIRED PERMITS, NPPROVFLS, INSPKTIONS AND
5. EXTEN�CARPETUNDEROPEN-BOTTOMEDOBSTRUCTIONSANDUNDER SI6N-OFFS.
REMOVABLE FLANGES AND FIIRNISHINGS. g, qLL ELEQRIUL WORK SHALL eE DONE IN NCCOR�ANCE WITH THE CURRENT NATfONNL
09900 PAMTING ELECrWCAL CODE.
A.PREPARATION FOR EXECUTION OF RNISHES: WSPECT ALL SURFACES TO BE C. HLL OUTLETS IN BATHROOMS, IaTCHENS, AND HT THE E%TERIOR ARE TO BE GROUND
FINISHED. NOTIFVTHEARCHITECTOFANVDEFECTS,IMPROPER FAULTINSULATED.
WORKMANSHIP OF MATERIALS OR CONDITIONS UNSUITABLE FOR FINISHING.
ABSENCE OF NOTIFICATION CONSTITUTES ACCEPTANCE OF ALL SURFACES. D. INSTALL FIXTURES AS PER MANUFACTURER'S SPEQFICATIONS.
THE RESPONSIBILITY OF THE RNAL APPEARANCE, AND WANES ANY
SUBSEQUENT CLAIM TO THE CONTRARV. E. PROVIDE WIRING FOR POWER FND CONTROL OF ALL NEW OR RELOCATED EQUIPMENT,
HPPLIANCES, AND HVAC EQUIPMENT. ELECTRICIAN TO VERIFY ALL WIRING/RECEPTHCLE
B. REFER TO FINISH SCHEDULE, DRAWING A052, FOR PAINT COLORS AND REQUIREMENTS. FINFL CONNECTIONS TO MOTORS TO BE FLEXIBLE STEEL CONDUIT.
MANUFACTURERS.
E NLL WORK SHALL BE COORDINFTED WITH THE OTHER TR4DE5 TO AVOID CONFLIQS.
C.OBTAIN BLOCK FlLLER$ PRIMERS AND UNDERCOAT MATERIALS FOR EACH
COATING SVSTEM FROM THE SAME MANUFACTURER AS THE FlNISH COAT. G. NLL NECESSARY QITTING AND PNTCHMG FOR THE WORK TO BE PERFORMED BY THIS
CONTRHCTOR.
D. ALL NEW AND EXISTING SURFACES ARE TO BE PAINTED, UNLESS NOTED
OTHERWISE. COMPLV WITH MANUFACTURER'S WRITTEN WSTRl1CTIONS FOR H. ALL MATERIALS AND WORKMANSHiP SHALL eE GUNRANTEED FOR A PERiOD OF ONE YEAR
SURFACE PREPARATION, ENVIRONMENTAL AND SUBSTRATE CONDITIONS, FROM THE DATE OF FINAL NCCEPTANCE OF THIS WORK.
PRODUCT MIXING ANo APPLICATION. PRE-RNISHEo METAL SURFACES
(ALUMINUM, BAKED ENAMEL, ETC.) ARE NOT TO BE PAINTED (U.N.OJ.
E.COVERALLSURFACESWITHDROPCLOTHES. REMOVEALLFINISHINGITEMS
SUCH AS ESCUTCHEONS, ELECTRICAL PLATES, ETC., AND STORE IN SAFE
PLACE ON SITE.
F. UPON COMPLETION, 1 TO 2 GALLONS OF ALL RNISHING MATERIALS USED
HEREIN SHALL BE STOREO ON THE SITE, AS DIRECTED BV THE OWNER.
G. PREPARATION:
1. EXIS�IN6 PLASTER AND DRVWALL:
REMOVE NLL PEELING AND SCNLING PAMT. SAND FREAS THOROUGHLY TO FFATHER
EDGES SMOOTH WITH HDJNCENT Sl1RFACES. CRACKS, HOLES AND BLEMISH NREAS
HRE TO BE FILLED HND SANDED FWSH WITH AD]ACENT AREAS. GLOSSY SURFHCES
SHOULD BE DULLED BY SANDIN6 LIGHTLV WITH A#00 SANDPAPER.
2. DRVWALL: NLL SURFACES MUST BE FREE OF SANDING DUST NND JOINT TREFTMENT
CEMENT SHOULD BE THOROUGHLY DRV. DAMAGED OR DEFECTIVE SURFACES ARE TO
BE REPAIRED BV SPAIXLING, OR BV OTHER APPROPRIATE MEASURES FS DEEMED
NECESSARY BV THE nRCHITECT. STEEL CORNER BEADS ARE TO BE COATED WRH A
SEALER/PRIMER BEFORE APPLVMG FlNISH COAT.
3. W00�: ALL SURFACES SHOULO BE DRV AND SANOED SMOOTH, FREE OF LOOSE DIRT,
DUST NND OiL PUTTY NLL NAILHOLES, CRNCKS, NND BLEMi5HE5 FFfER
UNDERCOFTER HAS BEEN FPPLIED. KNOTS ARE TO BE COATED WITH KNOT SEALER.
4 E%ISTING METAL REMOVE NLL PEELING AND SCNLING PAINT. SAND NREAS
THOROUGHLV TO FFATHER EDGE$ SMOOTH WITH AD]ACENT SURFFCES. HOLES AND
BLEMISH ARFAS FRE TO 8E FILLED NND SANDED FLUSH WITH AWACENT AREAS.
GLOSSV SURFACES SHOULD BE DULLED BV SNNDING LIGHTLV WITH #00 SNNDPFPER.
HLL SURFACES SHOULD BE DRV, FREE OF LOWE DIRT, DUST HND OIL.
5. EXISTIN6 MASONRY, CMU NN� CONCRETE: REMOVE ALL PEELIN6 AND SCALIN6 PNINT
TO A SOUND SUBSTRATE. REMOVE ALL MILDEW. REMOVE PRIOR APPISCATIONS OF
CEMENT BlvSED PNINT NND MULTIPLE CONTS OF PAINT IN AN ADVANCED STNTE OF
DETERIORATION. REMOVE OLD CR.4IXED AND LOOSE CAULKING AND REPLACE WITH
SILIWNE $EALANT. FILL OR REPOMT ALL STRUQURAL CRAIXS AND CREVICES WITH
NPPROPRIATE PATCHING COMPOUNDS. SURFNCES MUST BE CLEAN AND FREE OF ALL
WAX, GRFASE, OIL, DIRT, LOOSE OR FLAKMG MATERINL, ACID SUBSTANCES AND
SOAP DEPOSITS.
H.FWISHES:
1. MATERIAL NSTOM COLORS, BEST QUALIfV GRADE.
L WALLS: 1 COHT LATE%PRIMER (NEW GWB ONLY); 2 COATS LATIX, EGGSHELL.
3. WOOD FOR OPNQUE FINISH FND MEfFL: 1 COFT LFTEX PRIMER (NEW SURFFCES
ONLY); 2 COHTS HCRYLIC LATE%.
9. WOOD (SrAIN): INTERIOR 6RNDE PENETRNTIN6 SrAIN, TWO CONTS, MATCH
NRCHITEQS SAMPLE TWO COAT NCRVLIC VNRMSH, SNTM FMISH. SUBMif FMISH
SAMPLE.
5. CEILINGS (GWB/PLFSTERJ: 1 COAT L4TEX PRIMER; 2 CONTS L4TEX FL4T.
09950 WALLCOVERING:
A. PREPARE AND PRIME SURFACE (RLL VOIDS, ETC.) AND INSTALL WALL COVERING
PERMANUFACTURER'SRECOMMENDATIONS.
& FlNISH CLASS'A', RAME SPREAD RATING 10', SMOKE DEVELOPED FACTOR 20.
P11�FY21��il1[N�A
1. PRIMER AND PASTE SHALL BE FORMALDEHVDE FREE AND SHALL HAVE A LOW
VOC CONTENT. ROMAN ADHESIVES Inc (800.3565595), OR APPROVED EQUAL.
2. VENTILATION: PROVIDE MAXIMUM MECHANICAL VENTILATION WITH MAXIMUM
OUTSIDE AIR DURING INSTALLATION AND FOR A PERIOD OF ]2 HOURS AFTER
COMPLETION.
0. SUBMIT SAMPLE FOR REVIEW.
10520 FIRE EXTINGUISHERS AND CABINETS
N. SUBMif CATALOGl1E NT FOR REVIEW.
B. INSTALL PER MANUFALTURER'S RECOMMENDATIONS. SEE MNNUFAQURER5 LITER4TURE
FOR REQUIRED CLEARANCES AND BLOCKING.
G SEE EQUIPMENT SCHEDULE FOR MANUFACTUftER AND MODEL NUMBER
DIVISION 11-EQUIPMENT
11450 APPLIANCES
H. SUBMIT CATALOGUE NTS OF ALL HPPLIANCES FOR REVIEW.
B. INSTALL PER MANUFARURER'S RECOMMENDATIONS. SEE MANUFAQURER'S LITERATURE
FOR REQUIRED QFARNNCES, UTILITV ROUGHMG REQUIREMENTS AND LOCATIONS.
PROVIDE ALL REQl1IRED UTILITY AND PWMBING CONNECTIONS.
C SEE EQUIPMENT SCHEDULE FOR MANUFAQURERS AND MODEL NUMBERS
DIVISION 12 - FURNISHINGS
122000 WINDOW TREATMENT
H. SEE FINISH PIANS FOR WINDOW TREATMENT.
NOT USED
NOT USED
DIVISION 22 - GLUMBING
224000 PLUMBING FIXTURES
NOT USED
I. CONTRACTOR TO FURNISH AND MSTALL BOXES, FITTINGS, DEVICES, R4CEWAYS,
CONDUQORS, CONNEQIONS, MFG. ACCESSORIES, ADAPTERS, AND ALL OTHER
MATERIALS, EQUiPMENT AND LABOR EQUIPMENT NECESSARY FOR A COMPLETE
ELECrRICALINSrALLNTION.
]. HLL CONDUITS TO BE CONCEALED UNLE55 OTHERWISE NOTED.
K. CONTRFCTOR SHALL MAINTAM WNTINUITV OF ALL ELECTRICAL SVSTEMS TO FLL AREFS
NOT COVERED BY THIS RENOVATION AND SHALL PROVIDE 48 HOURS NOTICE TO
BUILDING MNNAGEMENT AND TENNTNT OF ANY PLANNED INTERRUPTIONS TO POWER OR
SIGNALSVSTEMS.
L TEST $VSfEM FOLLOWING INSTALLATION OF FIXTURES. SVSTEM SHALL BE FREE OF
SHORT CIRNITS AND GROUNDS AND SHNLL SHOW INSULNTION RESISTFNCE BETW EEN
CONDUQORS NND GROUND ON MNXIMUM LOND NOT LE55 THAN REQUIREMENTS OF THE
ELELTWCAL CODE.
M. FD� TVPEWRITTEN LABELS TO PANEL DIRECTORIES INDICATING CIRCUITS USED FOR
THIS wORK, IN A MnNNER nCCEPTABLE TO THE ARCHITEQ AND TENANT.
N. UPON COMPLEf10N OF ELEQRICAL WORK, THE CONTRFQOR SHNLL Fl1RNI5H THE
TENNNT WITH REPRODUCBLE SET OF AS-BUILT DR4WIN65 WHICH SHALL SHOW THE
FOLLOWING MFORMATION:
1. LOCATION OF ALL RECEPTACLES, SWITCHES, LIGHT FIXTURES, AC UMTS, MOTORS,
EfC.
L ROUTING AND DESIGNATION OF ALL BRNNCH aRCUITS.
3. LOCATION OF ALL JUNCTION BO%ES ANO PULL BO%ES.
4. WIRE SIZE WHERE WIRE LARGER THAN 2 k121S USED
DEVICES
A. POWER TEL/DATA WALL OURET OEVICES AND PLATES SHALL BE WHITE,
MOUNTED WITH THE CENTERLINE AT 18" a.f.C, UNLESS NOTED OTHERWISE.
COLORCOOERECEPTACLES:PERBACSTANDARD
B. SWITCH DEVICES AND PLATES SHALL BE WHITE, MOUMED WITH THE
CENTERLWEAT4'-0"a.ff.,UNLESSNOTEDOTHERWISE DOORRELEASEPUSH
BUTTONS SHALL BE MOUNTED WITH THE CENTERLINE AT 3'-2" a.f.f.
G FIRE ALARM STROBE AND SPEAKER DEVICES AND PLATES SHALL BE W HITE.
D. FLOOR BOXES SHALL BE AS FOLLOWS:
7. AT POKE THRU'S:
a. RACEWAY COMPONENTS #RC-]0�-6-A, (WITH TILE GASKET AT HARD FLOORS).
TEL OR DATA: RACEWAV COMPONENTS NRC-9�0-FF-025, WITH 1-014" KNOCKOUT
IN TOP OF HO1151NG, (AND TILE GASKET AT HARD FLOORS).
NOTE: OMIT BARRIERS AN�'CA' ADAPTER.
E FOR OUTLETS:
1. ATPOKETHRU'S:
a. R4CEWAVCOMPONENTS#RG]�0-A(DUPLEX)AN�#RC-900-A(OUAD),(WITH
TILE GASKET AT HARD FLOORS). COORDINATE WITH AMPS.
b. NOTE: FOR SPEqAL PURPOSE RECEPTACLES, SUBSTITUTE SURFACE MTD.
HOUSING (SUCH AS #FlT-200 SERIES) WITH APPROPRIATE FlTTINGS. TEL OR
OATA'. RACEWAV COMPONENTS #RG9�0-A-M-D, (WITH TILE GASKET AT HARO
FLOORS). "
END OF SPECIFICATIONS
,
N E LSOI�
Nelco Architecture, Inc.
a licensed affiliate
30 West Monroe Street - Suite 200
Chicago,IL 60603-2409
Phona (312J263-6605
(312)2]6-4340
OWNER'S PRO]ECT MANAGER
]ones Lang LaSalle
Alex Cisneros
540 W. Madison St, Suit eIL4-540-04-SS
Chicago, IL 60661
T: 77350L5562 E: alex.cisneros@am.jlLmm
MEP ENGINEER
Integrated Engineering Consultants, Inc (IEC)
Tim Vining
9700 Rockside Road, Suite 290
Cleveland, OH 94125
T: 216.901.6711 E: tim.vining@ierinccc
GENERALCONTRACTOR
Mid America Contractinq, Inc.
Tyler Crawford
107 N. Main Street, Suite 3A
Columbia, IL 62236
T: 618.977.9255 E: tic@midamericacontracting.mm
ConsulWnt:
MERRILL�,i
A BANK OFAMERICA COMPANY
Client
INW-044 BofA Indianapolis MLWM
Expansion & Refresh, 3rd Floor
510 96th Street
Indianapolis, IN 46240
Projec[ Title & Atltlress:
SPECIFICATIONS
Sheet Title:
0326.2020
Seal:
Proj. Na: 19.0004]36.000 Designer. ERO;MBM
Drawn By: ERO Reviewed By: M]L
Projec[Manager. MJL Approvetl ey: VPD
AN-4.2
nu o�wErvs�orvs arvo corvo�norvs nusT aE cnEaEo nrvo vEa�F�Eo
oN ArE m' i ne [ory i un[i oe nn�o su�{Om i kneioxs vxiov i o
PERFORMING THE WOFK THE P0.0]KT MANAGER SHALL BE NOTIFIE� IN
WRITING OF ANY �6CFEPANCIES PFIOR TO PP�CEE�ING 4VRH THE WOFK.
OO NEISON WORLDWIDE, LLC 2W0 nLL RIGMTS RESERVED