HomeMy WebLinkAboutE0-1WIRING (OUTLET) DEVICE SYMBOL LEGEND
SYMBOL
LLU
�
�X
0
DESCRIPTION
DUPLE% RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDWG ttPE MOUNTED
AT 18" AFF UNLE55 NOTED OTHERWISE
DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDING ttPE
AIOUNTED AT 18" AFF UNLESS NOTED OTHERW6E
RECEPiACLE SYMBOL WITH ADDITIONAL SUBSCRIPi DESIGNATES IYPE OR SPEqFIC
REQUIREMENTS AS FOLLOWS:
"+48" RECEPiACLE MOUNTE� AT HEIGHT INDICATED
8" POWER AN� TELECOM FIRE RATE� PONE-THROUGH �EVICE LEGRAND EVOWTION SERIES
wBATCP. COOR�INATE ALL REQUIREO DEVICE MOUNTING PLATES AN� COVERS WITH A/V
VEN�OR �RAWINGS PRIOR TO PURCHASE ORDER.
� FWSH FLOOR MOl1ME0 POWER ANO TELECOM FIRE RATED POKE-THROUGH �EVICE WITH
FURNITURE FEE� COVER/FIANGE HUBBELL SYSTEM ONE, 3/4" CON�UIT STEM FOR POWER
nNo i-i/z°coNouir sTEM Foa onrn; qsiaFe wiTH EirHER qsisaFFaRs covER/F�nNCE(FOR
caRv�r) oR qsisPF�raRs covEa/F�aNCE (FOR ri�E). aRovmE oNE i-i�z° coNouir (FOR
TELECOM) BELOW fL00R TO NEAREST WALL AN� EXiEN� TO 17' ABOVE ACCESSIBLE CEILING
OF FLOOR. VERIFY COLOR OF COVER PUIE WITH ARCHITECT. PROVIDE ALL NECESSARY
APPURTENANCES INCLU�ING WHIP IF REQUIRE� AND MAKE FINAL CONNECTIONS TO SYSTEMS
NRNITURE.
FIRE ALARM SYMBOL LEGEND
0�
0
COMBINATION AUDIBLE/VISUAL (HORN/STROBE) SIGNALING DEVICE
VISUAL (STROBE) ONLY SIGNALING DEVICE
LIGHTING CONTROLS SYMBOL LEGEND
SYMBOL
�
�,
OS
oEscRiPrioN
LIGHT SWITCH. SINGLE POLE, 20 AA�PERE, 120/277 VOLT, iHP.
LIGHi SWITCH. '%" INDICATES THE FOLLOWING:
"a" CONTROL OF INDICATED LUMINAIRES
'VD" WALLBOx PIR VAVANCY SENSOR WITH 0-10V DIMMING.
ACUItt CONTROLS: WSX PDT-D-VA-WH
"M" LOW VOLTAGE A�OMENTARY CONTACT SWIiCH FOR OCCUPANCY SENSOR OVERRIDE.
ACUItt CONTROLS
"D" WALL SWRCH WITH RAISE/LOWER (BRIGHTEN/DIM) CONTROL. ACUIN
CONTROLS. ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY PARTS AND
WSTALL PER IAANUFACTURERS REOUIREMENiS FOR A COMPLETE AND WORKING
SYSTEM.
CEILING MOUNTED DOAL TECHNOLOGY OCCOPANCY SENSOR.
ACUIN CONTROLS: CMR-PDT-10
LIGHTING SYMBOL LEGEND
SYMBOL
F2A
�°
A1
❑
F3
�NL
DESCRIPTION
RECESSE� OR SURFACE MOUNTED 2'x4 WMINAIRE. "XR/XN" IN�ICATES WMINARE TO BE
REUSED AN� RECLOACTEO; "a' IN�ICATES SWITCH CONTROL REFER ID WIAINAIRE SCHEDULE
FOR AD�ITIONAL MFORMATION.
RECESSED OR SURFACE MOUNTED 2'x2' LUMINAIRE. "A1" INDICATES IYPE; "a' INDICATES
SWITCH CONTROL. REFER TO LUMINNRE SCHEDULE FOR ADDITIONAL MFORIAATION.
RECESSEO �OWN LIGHT OR SURFACE MOUMED CYLIN�ER. "XR/HN" IN�ICAiES WMINARE TO
BE REUSED ANO RELOCATED. REFER TO WMINAIRE SCHE�ULE FOR AO�ITIONAL MFORMATION.
LUMINAIRE WIRE AS A NIGHT LIGHT.
LUMINAIRE SCHEDULE
LAMPS MANUFACTURER
iYPE WATfAGE VOLTAGE DESCRIPTION AND CATALOG REMARNS
Na. IYPE NUTABER
LED 7x4' RECESSE� WMINAIRE WITH STEEL HOUSING AN� CENTER CLEAR ACRYLIC LITHONIA:
F�A - 350PK 32 UNV �IFFUSER. 0-10V DIMMWG �RIVER STANDAR�. �2ViL4-40L-ADP-EZI-LP835
SAA�E AS IYPE °F2A" EXCEPT 2' X 2' LITHONIA LIGHTING:
F'� B _ LE� 33 UNV �2V1L2-40L-ADP-EZI-LP835
3500'K
SAME AS IYPE "F2B° E%CEPT WITH EMERGENCY BATfERY PACK LIiHONIA LIGHiING:
F'z B E _ LED 33 UNV �2WL2-40L-A�P-EZI-LP835-EL14L
3500'N
LED RECESSE� OPEN DOWNLIGHT WITH 4" SQUARE APERTURE, SELF-FLANGED GOTHAM:
F3 _ LED p� UNV SEMI-SPECUTAR, MATfE-�IFFUSE LOWER REFLECTOR, AN� 0-10V DIMMING DRIVER �EV04SQ-35/10-AR-L�-MVOLT-GZI-TRW
3500'K STAN�ARD.
EXIT SIGN TO MATCH EXISTING POLYCARBONATE WITH SILVER FACES EXIT SIGN IN ttPE, MATCH EXISTING
MATCH SiYLE, LETiERING COLOR, POWER REOUIREMENTS EfC. COOR�INAiE WITH ARCHITECT
�AI - EXISTING 5 UNV pRIOR TO PURCHASE ORDER. WOR�INATE CHEVRONS, AN� MOl1NTING ttPE WITH
LIGHTING PVJJS PLANS.
1. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILINGS ttPES, LUMINAIRE COLORS, LENGTHS, TRIMS, FINISHES, MOUNTING HARDWARE, CONFIGURATIONS AND HEIGHTS OF SUSPENDED WMINAIRES, EfC. WITH ARCHITECT PRIOR TO ANY
ROUGH-MS AND PLACING FINAL PURCHASE ORDERS.
2. VERIFY FINAL LUMINAIRE LOCATIONS WITH OTHER CEILING MOUNTED EQUIPMENT SUCH AS DIFFUSERS, FIRE AIARM DEVICES, SPEAKERS, ETG WITH ARCHITECTURAL RCP (REFLECTED CEILING PLANS).
3. VERIFY EXACT HEIGHT AND LOCATIONS OF ALL WALL MOUNTED AND PENDANT/CABLE MOUNTED LUMINAIRES WITH ARCHITECTURAL ELEVATIONS PRIOR TO ANY ROUGH-IN.
4. LUMINAIRES SHALL NOT BE SUPPORTED FROM SUSPENDED CEILING SUPPORTS UNLESS ADDITIONAL CEILING FRAMING AND SUPPORTS ARE ADDED BY THE CEILING CONTRACTOR ACCORDING TO MANUFACTURER'S RECOMMENDATIONS LLL.
LISTINGS, AND ANY APPLICABLE STATE OR LOCAL CODES.
5. CONNECTIONS TO RECESSED LUMINAIRES SHALL BE MADE WITH MINIMUM 1/2° FLEXIBLE METAL CONDUIT (FMC) FROM FI%TURE TO OUTLEf BO%. LENGTH OF FMC SHALL NOT E%CEED 6'.
6. AT THE WNCLUSION OF THE WORK, EACH LUMINNRE MUST BE CLEANED PER MANUFACTURER'S INSTRUCTIONS, E�UIPPED WITH THE PROPER ttPE, NUMBER OF lAMPS, INCLUDING KELVIN TEMPERATURE AND WATfAGE, AND ALL IN GOOD
OPERATING CONDITION.
ALL LIGHTING CONTROL �EVICES AND WMINARES MUST BE
PURCHASE� THROUGH SWTf CRAWFORD OF BOR�ER STATES
ELECTRIC OR JAY MELR OF WALTERS WHOLESALE ELECTRIC C0.
SCOTf CRAWFORD: 8fi4-556-6402
eoROER srnTEs E�Ecmic
E: BOA�BOR�ERSTATES.COM
JAY MELR: 714-412-19fi4
WALiERS WHOLESALE ELECTRIC C0.
E: JAY.MELFl�WALTERSWHOLESALECOM
RELEA5E0 FOR CONSTRIlCTION
Su6jec��o compliance with allregula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM��.
DATE: Qrj�Q�j�2O
AS REQUIREDPOWER
3/4'C TO ACCE55 FACR 3/4"C TO FACP (FIRE AIARM CONTROL PANEL)
CONiROL PANEL JB
MD CEILING
CARD READER/ELECTRIC STRIKE DETAIL
TO
CR
CR FLUSH IAOUMED BACK BOR ON SECURE SIDE OF DOOR FOR CARD READER.
MOUNi PER ADA REQUIREMENTS.
FACR FIRE AIARM CONTROL RELAY FOR DOOR RELEASE.
�B JUNCTION BO% 8" X 10" W/CWER, ON SECURE SIDE OF SPACE 6" ABOVE
ACCESSIBLE CEILING.
ES ELECTRIC STRME CONCEALED WITHIN DOOR FRAME.
MD MOTION DETECTOR
FLOOR
POWER DISTRIBUTION EQUIPMENTSYMBOL LEGEND
SYMBOL DESCRIPTION
� 208Y/120 VOLT, 30, 4 WIRE BRANCH CIRWIT PANELBOARD
DEMOLITION ANNOTATION LEGEND
"g" DENOTES ExISTMG DEVICE/EQUIPMENT i0 BE REIAOVED IN ITS ENTIREIY INCLUDMG JUNCTION
BOXES, CONDUITS AND CIRCUITRY, ETC. COMPLETE, BACK TO SOURCE OR NERT ACTNE DEVICE
BEMG MAINTAMED ON CIRCUIT.
°XR" DENOTES EXISTING �EVICE/EOUIPAIENT i0 BE RELOCATED IN IT$ ENTIREIY. MAINTAIN ALL
BRANCH CIRWIT WIRING, CONDUIT, ETC. FOR RELOCATION TO NEW LOCATION ('%N") AS
INDICAiED ON 'NEW WORK" DRAWINGS.
°%N" DENOTES NEW LOCATION OF EXISTMG RELOCATED (°NR') DEVICE/EQUIPMENT. REWORK ALL
BRANCH CIRCUIT WIRING, CONDUIT, ETC. i0 NEW LOCAiION A$ REQUIRED.
"%M" DENOTES EXISiING DEVICE/E�UIPA�ENT TO BE MAINTAMED.
TYPICAL DEVICE MOUNTING
A
FlRE AIARM AUDIBLENISUAL AND
VISUAL ONLY SIGNALING DEVICES
RECEPTA0.E5 BEHIND
REFRIGERATORS AND
VENDING MACHMES
�WALL TELEPHONES
FIRE AIARM MANUAL PULL STAiION
LIGHTING CONiROLS (CONFIRM MOUNTING HEIGHT
�.� WITH LOCAL CO�E REQUIREMEMS)
� VOLUME CONTROLS
� A DI�OR BACKSPLASHTERTOP �
� � � � � RECEPTACLES IN MECH�ELEC
SPACES AND AUTACENT TO � � �
LAVATORIES �' p
� �� RECEPTACLES BEHIN�
�` �OIAESTIC WASHERS
� nNo oRrERs
�GENERAL PURPOSE � �
RECEPTA0.E5
M � � �'� R�ECE TACLES SERVING �
�ISHWASHER AN�
� GARBAGE �ISPOSAL
NOTES:
1. ALL MOUNTING HEIGHiS SHALL BE MEASURED FROIA FlNISHED FLOOR TO THE CEMERLWE OF DEVICE
EXCEPT FIRE AURM SiROBE LIGHT.
2. NO WIRING DEVICE OUTLET BOXES SHALL BE MOUMED BACK TO BACK.
3. ALL IAOUNTING DEVICES SHALL BE INSTALLED AT MOUNTING HEIGHiS AS INDICATED ON THIS DETAIL
UNLESS OTHERWISE NOTED.
4. FOR ALL ELEVATIONS (WHERE APPLICABLE), CASEWORK DEfAILS, FIRE WALLS, SMOKE WALLS, LOCATION
OF COUNTERTOP RECEPTACLES, LIGHTING FI%TURE SWITCHES, TELEPHONE OUTLEfS, EQUIPMENT
ROUGH-INS, HEADWALLS, EfG, SEE ARCHITECTURAL DRAWINGS WHERE NO ARCHITECTURAL ELEVATIONS
OR DEfAILS OCCUR, THE ELECTRICAL CONTRACTOR SHALL USE PRACTICAL MEANS AND MEfHODS AS
WELL AS HIS FIELD KNOWLEDGE TO LOCATE DEVICES IN THE BEST SUITED AND MOST PRACTICAL
LOCATIONS FOR THE DEVICE.
SINGLE DOOR SECURITY DETAIL SCALE:NONE
NpTES;
1. CARD READER PROVIDE� BY TENANi'$ SEWRIN VENDOR ELECTRIC STRIKE PROVIDED BY DOOR
HARDWARE VENDOR.
Z WORK TOTPROVIDE�ATCOA�PLRETE OPERATIONALNDOORSPERSALL STATE ND LOCALRCODE R EQUIREA�ENTS.
3. COORDINATE WIiH iENANT'S SECURIN VENDOR PRIOR TO ANY ROUGH-IN THE EXACT REQUIREMENTS
FOR ALL CONDUITS, �EVICE BACK BOX SIZES LOCATIONS, MOUNTING HEIGHT$ ETC COORDINATE WIiH
FIRE AIARM CONTRACTOR AN� VENDOR FOR {'IRE AIARM INTERFACE POINTS AS REOUIRED.
�Inregrared
1�En�'meerinp
Consvdtants,lnc.
9700 ROCNSIDE RD.SURE790
CLEVELAND.OX 44125
PHONE:21G90L6711
FA%:216A01-6712
GENERAL ELECTRICAL NOTES
1. ALL 'BUIL�ING STAN�AR�S" ANO/OR "BUILDING SPECIFICATIONS" SHALL BE CONSI�ERED AN INiEGRAL PART OF
THESE OOCUMENTS AN� THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN A COPY OF THESE DOCUMENTS
AN� COMPLY WITH ALL REQUIREMENTS, STAN�AROS, AND SPEQFICATIONS CONTAINED WITHIN.
2 THESE DRAWINGS ARE GENERALLY �IAGRAMMATIC AND ARE IMENDE� TO CONVEY THE SCOPE OF WORK AN�
INDICATE GENERAL ARRANGEMENT OF LIGHTING FIX�URES, DEVICES, CONTROLS, ELECTRICAL FIXTURES, MOTORS,
PANELBOARDS, EOUIPMEM, EfC. THE LOCATIONS OF ALL ITEMS SHOWN ON THESE �RAWINGS OR CALLEO FOR IN
THE SPECIFICATIONS THAT ARE NOT OEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE. THE EXACT LOCATIONS
NECESSARY TO SECURE THE BEST CON�ITIONS AND RESULTS MOST BE �EfERMINE� AT THE PROJECT. ALL
LOCATIONS OF WORK EXPOSEO TO VIEW ARE SUBJECT TO APPROVAL OF THE ARCHRECT PRIOR TO ROUGH-WS.
3. THE ELECTRICAL WNTRACTOR SHALL VERIFY EXISTING CONDITIONS TO WSl1RE iHAT ALL NEW WORK WILL FIT IMO
THE EXISTING STRUCTURE AN� CON�ITIONS IN THE MANNER INTEN�E� AN� AS SHOWN ON THE �RAWINGS. THE
CONTRACTOR SHALL NOTIFY THE ARCHRECT/OWNERS REPRESENTATNE PRIOR TO ANY ROUGH-INS, FABRICATIONS,
OR PERFORIAMG ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFlCATION SHALL BE IN THE FORM OF A
RFl, INCW�MG A DRAWING OR SKEiCH INDICATING FlELD MEASUREMENTS AN� NOTES RELATED TO THE AREA.
4. ANY DISCREPANCIES BEiWEEN DRAWINGS AND SPECIFlCATIONS SHALL BE PROMPTLY BROUGHT TO THE ATTENTION
OF THE ENGMEER FOR CIARIFlCATION DURING THE BIDDING PERIOD. NO ALLOWANCE SHALL SUBSEOUENTLY BE
MADE TO THE CONTRACTOR BY REASON OF MS FAIWRE TO HAVE BROUGHT SAI� DISCREPANCIES TO THE
ATfENT10N OF THE ENGMEER DURING THE BIDDING PERIOD OR OF ANY ERROR ON THE CONTRACTOR'S PART.
5. ALL EOUIPIAENT SHALL BE INSTALLED IN A NEAT, PROFESSIONAL AND WORKIAANLME MANNER, RECTILWEAR TO
FINISHES AND BWLDING SiRUCTURE.
6. ALL COMPONENTS SHOWN ON THE RISER ONE-LINE DIAGRAMS BUT NOT ON THE PIAN OR VICE VERSA SHALL BE
INCWDE� AS IF SHOWN ON BOTH. /
�. REr�R ro nRcwTEcruan� E��vnnoNs ro oERivE E�cr �ocanoNs oF n�� aECEPrnc�s, ouT��rs�dncKs,
SWITCHES, WALL AND PENDANT/CABLE MOUNTED LUMINAIRES, ETG LUMINAIRES AND CEILING MOUNTED EQUIPIAENT
SHALL BE COORDINATED WITH THE ARCHRECTURAL RCP (REFLECTED CEILING PLANS).
8. ALL CIRCUITING SHALL BE RUN CONCEALED UNLE55 SPECIFlED OTHERWISE.
9. ALL RACEYVAYS RUNNING THROUGH BUILDING EXPANSION JOINTS SHALL BE EQUIPPED WITH APPROPRIATE
EXPANSION FITfINGS.
1Q CON�UIT HOME RUNS SHOWN ON THE DRAWING WITH MORE THAN (3) CURRENT CARRYING CONDUCTORS ARE
SHOWN DWGRAA�ATICALLY. THIS CONTRACTOR SHALL NOT INSTALL MORE THAN (3) CURRENT CARRYING CONDUCTORS
IN A RACEWAY UNLESS NATIONAL ELECiRIC CODE (N.EC), ARTICLE 310.15 DERATING FACTORS ARE APPLIED.
11. ALL LIGHTING AND GENERAL POWER BRANCH CIRCUITS SHALL INCLU�E A SEPARATE NEUTRAL CONDUCTOR, UNLESS
SPEpFlCALLY INDICATED OTHERW6E.
12. THE ELECTRICAL CONTRACTOR SHALL REFER i0 THE ELECTRICAL SPECIFlCATIONS FOR ACCEPTABLE CONDUIT
IYPES/LOCATIONS. ALL CONDUIT SIZES ON THE �RAWINGS ARE BASED ON THE CURRENT AOOPTE� EDITION OF THE
N.EG WNDUIT FlLL TABLES FOR ELECiRICAL MEfALLIC TUBING (E.M.T). WN�UIT SRES SHALL BE REVISED TO
THE SRE REQOIRE�, REIATIVE TO THE ACTUAL CON�UIT NPE TO BE WSTALLE�.
13. IT IS NOT IMEN�ED THAT THE PVilJS INOICATE ALL OBSTRUCTIONS, NECESSARY BENDS, OFFSEfS, AN� Pl1LL
BOXES. IT SHALL BE iHE RESPONSIBILIIV OF THE WNTRACTOR TO INSTALL HIS WORK TO CONFORM TO N.EC.
REQUIREMENTS, THE STRUCTURE, MAINTAIN HEADROOM AN� KEEP OPENINGS AN� PASSAGEWAYS CLEAR. REFER TO
THE ARCHITECTURAL �RAWINGS FOR ALL �IMENSIONS AS REQOIRE�.
14. IT IS NOT INTEN�E� THAT THE PIANS INOICATE ALL WNDOIT ROUTES, PULL BOHES, JUNCTION BOXES, EfC.
CONTRACTOR SHALL BE RESPONSIBLE FOR �EfERMINING ACTUAL CONOUIT ROUTING, QUANTItt AN� LOCATION OF
POLL BOXES WITHIN ACCES9BLE LOCATIONS.
15. PROVI�E SCREW-COVER PULL BOXES IN CON�UR RUNS AS RWUIRED TO LIMIT THE NUMBER OF BENDS TO NO
MORE iHAN FOUR (4) 90' OR 360 DEGREES iOTAL. SIZE PULL BORES IN ACCORDANCE WIiH NEC, ARTI0.E
31428. DOCUMENT ON RECORD DRAWINGS, SIZE AND LOCATION OF PULL BORES USED W FEEDER CONDUIT
RUNS.
16. WHERE MULTIPLE DEVICES OF THE SAME ttPE/SttLE ARE SHOWN NE%T TO EACH OTHER, GANG TOGEfHER IN A
SINGLE COVER PLATE.
17. ALL FWSH MOl1MED PANELBOARDS SHALL HAVE THREE (3), 3/4" CONDUITS SiUBBE� ABOVE ACCESSABLE
CEILINGS FOR FUTURE CIRCUITS.
1fl FIEL� VERIFY THE EXACT LOCAiION OF MECHANICAL HVAC AND PWMBING EQUIPMENT THAT REQUIRE ELECTRICAL
CONNECTIONS WITH RESPECTIVE CONTRACTORS.
19. ALL CIRCUITS INDICATE� ORIGINAiING M EXISTING PANELBOARDS ARE BASE� ON INFORMATION OBTAIN PRIOR TO
ANY DEIAOLITION WORK. IF A CIRCUIT NUMBER(S) IN�ICATE� TO BE RE-USED REMAWS "IN-0SP' AFTER ALL
DEMOLITION WORK IS C0IAPLETED, iER1AINATE HOMERUN ON A SPARE(5) qRCUIT BREAKER IN SAME PANEL OR
PROVIDE A NEW CIRCUIT BRFAKER(S) TO MATCH EXISTING IYPE AN� HOMERUN TO AVAIIABLE SPACE(S) IN SAME
PANEL.
20. ALL CONDUR 9ZES IN�ICAiE� ARE BASED ON ELECTRIC MEfALLIC TUBING (EMT). THE ELECTRICAL CONTRACTOR
SHALL BE RESPONSIBLE FOR PROPERLY SIZING ALL OTHER WNDOITS NPES USED PER NEC REOUIREMENTS.
TELECOMMUNICATION OUTLET SYMBOL LEGEND
SYMBOL DESCRIPTION
V COMBINATION VOICE/DATA OUTLEi (4-n/i6" x 2-1/8" DEEP JUNCTION BO%) COMPLETE
WITH SINGLE GANG DRY WALL RING (VERIFY DRTNALL THICKNE55) MOUMED AT 18' AF.F.
PROVIDE 3/4" CONDUIi WITH MSUTATING BUSHING AND PULLSiRING STUBBED UP 12" INTO
ACCESSIBLE CEILING SPACE.
CIRCUITING AND RACEWAY LEGEND
•691�I:T�71
- HP2/7
�7j�8AWG �10(G), 1'C
LP1�8,10,12
40/3
H��_
N��
XXX/j�,�,�
0
DESCRIPTION
RUN i0 PANEL "HP2", CIRWIT �7 wA A 20A/1P CIRCUIT BREAKER WIiH
'G, j�12(G), 3�4"CONDUIT UNLESS NOiE� OTHERWISE.
TO PANEL "LPi", CIRCUIiS j{'S 8,10,12 VIA A 40A/3P qRCUIT BREAKER
SIZE/QUANil7Y AS INDICATED.
HOME RUN. HASH MARNS INDICATE CONDUCTOR QUANIIY AND lYPES "�" INDICATES
CONOUCTOR SIZE.
CIRCUITING. "XXX" INDICATES PANEL DESIGNATION. 'j�' IN�ICATES CIRCOIT NUMBER.
UNDER FLOOR OR IN-SUB CIRCUITING OR RACEWAY
CIRCUITRY TURNING UP
NELSOI�
Nelm Architecture, Inc.
a licensed affiliate
30 West Monroe Street - Suite 200
Chicago, IL 60603-2409
Phone: (312)263-6605
(312)2]fi-4340
OWNER'S PROJECT MANAGER
Jones Lang LaSalle
Alex Gsneros
540 W. Madison St, Suit eIL9-540-04-55
Chicago, IL 60661
T: 773.502.5562 E: alex.cisneros@am.jlLmm
MEPENGINEER
Integrated Engineering ConsWtants,Inc (IEC)
Tim Vlning
9700 Rockside Road, Suite 290
Cleveland, OH 44125
T: 216.901.6711 E: tim.vining@iec-inc.cc
GENERALCONTRACTOR
Mid America Contracting, Inc.
Tyler CrawfOrd
107 N. Main Street, Suite 3A
Columbia, [L 62236
T: 618.9779255 E: tic@midamericacontrac[ing.com
ConsWtant'.
M ERRI LL �
A BANK OF AM ERICA COMPANY
Cllent.
INW-044 BofA Indianapolis MLWM
Expansion & Refresh, 3rd Floor
510 96th Street
Indianapolis, IN 46240
Projcct TiHc & Address:
ELECTRICAL SCHEDULES, LEGENDS
AND NOTES
SheetTiHe�.
� ' PE1180�515 ^'
• •
�o�t STATEOF ;o-
,i/ 2 „�_",/, ,
(/.'Ol,� �N/"
�
Seal:
Proj. No'. 19.0004J36.000 Designer'. ERO;MBM
�rawn By: T6V Reviewed By: NM
Pmjec[ Manager'. M]L qppmved By: NM
EO-1
na mwems�orvs nmo mmo�r�oms wusr oe cHecKeo nrvo vea�F�eo
ON 9TE BY THE CONTRAQOP AND 50B-CONTRAQORS PRIOR TO
PEFFOkMMG THE WOFK. THE PRO]ECT MHNAGEk SHALL RE NOTIFIED IN
WRITING �F ANY �ISCREPANCIES PRIOR TO PROCEE�ING WITH THE W�RK.
c� rve�mry won�owroe, uc zozo nu a�sHTs aFseaveo