Loading...
HomeMy WebLinkAboutE1-1�Inregrai�d 1�Fnnineerinp Consvltants,lnc. 9700 ROCNSIDE RD. SURE 790 CLEVELAND.OX 44125 PHONE:21G90L6711 FA%:216A01-6712 NELSOI� Nelm Architecture, Inc. a licensed affiliate 30 West Monroe Street - Suite 200 Chicago, IL 6060&2409 Phone: (312)263-6605 (312)2]fi-4340 OWNER'S PROJECT MANAGER Jones Lang LaSalle Alex Gsneros 540 W. Madison St, Suit eIL9-540-04-55 Chicago, IL 60661 T: 773.502.5562 E: alex.cisneros@am.jll.com MEPENGINEER Integrated Engineering ConsWtants, Inc (IEC) Tim Vlning 9700 Rockside Road, Suite 290 Cleveland, OH 44125 T: 216.901.6711 E: tim.vining@iec-inc.cc GENERALCONTRACTOR Mid America Contracting, Inc. Tyler Crawford 107 N. Main Street, Suite 3A Columbia, [L 62236 T: 618.977.9255 E: tic@midamericacontracting.com 3RD FLOOR ELECTRICAL POWER DEMOLITION PLAN 1�q„ = 1,-0•• RELEA5E0 FOR CONSTRIlCTION Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��. DATE: Qrj�Q�j�2O r�-6��---r-� i X XLX--- I I I / � �\ �III I( i � I _--_i 'f k_�ii I I� ���� � T � II V �� � \I I �� I�i � � I I IL�_�� L_�J ��� i� %� V / \/ I �—�� / II / II / r �� II� 'I �f= ��, //� �i `�� �, ���� �i x rs,� � , i _ �' _�,_ ��II I iX' —=JL__ � ix� � GENERAL DEMOLITION NOTES: 1. THESE DRAWMGS ARE DIAGRAMMATIC ONLY AND ARE TO BE USED AS A GUIDELME ONLY FOR THE SCOPE OF DEMOLITION WORN. THE WNTRACTOR SHALL V51T THE PROJECT SRE DURING THE BID PHASE TO VERIFY THE ExACT WNDITIONS AN� SCOPE OF WORK REQUIRED FOR A COIAPLEiE AND MCLUSIVE DEMOLITION PACKAGE. 2. THE WNTRACTOR SHALL BE HELD i0 HAVE ExAIAMED THE PREMISES AND SRE SO AS TO COIAPARE THEM WITH THE CONTRACT DOCUMENTS AND TO HAVE SATISFlED HIIASELF AS TO iHE CONDITIONS OF THE PREMISES, THE SITE, ANY OBSTRUCTIONS. THE ACTUAL LEVELS, ACCESS PANELS, AND ALL OiHER ExISTMG CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FlELD, SHALL CHECK LOCATION OF AND WNNECTION TO EXISTING FAQLITIES, AND SHALL ASSUME ALL RESPONSIBILIN FOR SAME. 3. THE CONTRACTOR SHALL COOR�INATE WITH THE TENANT AND/OR BUILDING IAANAGEMENT ALL IMERRUPTION OF ELECTRICAL SERVICES WITHIN THE TENANT SPACE AND/OR BUILDMG. 4. ALL E%ISTING LUMINAIRES AND ASSOQATED CONTROLS, ELECiRICAL EQUIPMENT, WIRING DEVICES. FlRE AIARM DEVICES, EiC. NOT INDICATED ON THIS PLAN SHALL BE ENISTING TO REMNN, UNLE55 SPEQFlCALLY NOTED OTHERWISE. 5. FOR ALL RENOVATION/REMODELMG WORK, INCLUDMG ALL AREAS OF NO OR MINIMAL WORK, EXISiING ELECiRICAL SERVICES SHALL BE IAAINTAWED TO LUMINAIRES, EQUIPIAENT, WIRING DEVICES, EiC. (POWER, LIGHTMG, ETC.), iHAT ARE REQUIRED TO BE IAAINTAWED. THE CONiRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THESE SERVICES, EQUIPMENT, WIRING DEVICES THAT ARE E%ISTMG TO REMAIN, WHETHER OR NOT INDICATED ON THE PUNS. 6. DISCONNECT AND REIAOVE ALL ENISTING ELECTRICAL EQUIPA�ENT, WIRING DEVICES, TELECOM DEVICES, BIANK COVER PLATES, ETC. LOCATED IN WALLS/PARTITION$ IABELED AS 'TO BE REIAOVED". REIAWE ALL EKISTING BRANCH CIRCUITING (WNDUCTORS AND WNDUIT) BACK TO IAST ACTNE DEVICE (OR SOURCE IF NO ACTNE DEVICES REMAIN). 7. ALL ELECTRICAL LUTAINAIRES, EQUIPMENi, WIRING DEVICES, TELECOMMUNICATIONS VOICE/DATA CABLING ETC. SHALL BE REA�OVED COMPLETE, BACK TO SOURCE, (PANELBOARD, TERMINAL BOARDS, ETC.), INCLUDING ALL BRANCH qRWITMG, (CONDUCTORS AND CONDUIT), FEEDERS, SUPPORTS, JUNCTION BOXES, PULL BOXES, ETC. 8. MAINiAIN OR PROVIDE TEMPORARY ELECTRICAL SERVICES. SUCH A$ LIGHiING AND POWER IN ALL AREAS OF DEIAOLITION AND SURROUNDING AREAS NOT IN �EMOLITION. 9. THE CONTRACTOR SHALL COORDINATE WRH THE ARCHRECTURAL, MECHANICAL HVAC, AND PLUMBING DEIAOLITION DRAWINGS FOR ALL EQUIPMENT BEING DEMOLSHED, AND SHALL DISCONNECT AND REIAWE COIAPLETE THE ELECTRICAL SERVICES TO ALL EQUIPMENT AND WIRING DEVICES. 10. EQUIPMENT AND WIRING DEVICES INDICATED AS 'KR", (EXISTING TO BE RELOCATED), SHALL BE STORED FOR RE—USE AS INDICATED "XN", (NEW LOCATION OF ENISTING RELOCAiED DEVICE), ON NEW PIAN DRAWINGS. DEVICES SHALL BE CLEANED, LUMINNRES RE—IAMPED PER SPEQFlCATIONS, AND BALLAST REPIACED WHERE FOUND TO BE INOPERABLE. iL ERISTING FlRE AURM DEVICES THAT ARE 'RM", (ERISTING TO REA�AIN), SHALL BE PROTECiED FROM CONSTRUCTION DAMAGE AND DIRT. THE FlRE ALARIA SYSTEM SHALL BE KEPT OPERABLE DURING CONSTRUCTION. 12. ANY CIRWITS FEEDING THROUGH EQUIPMENT OR DEVICES THAT ARE BEING DEMOLISHED, REWORKED, OR RELOCATED, AND FEEDING OTHER EQUIPMENT/DEVICES THAT REMAIN ARE TO BE MAINTAMED. 13. ALL CUTTING AND PATCHING OF WALLS, CEILINGS, OR FLOORS iHAT ARE DISiURBED BY DEIAOLITION SHALL BE REiURNED i0 THEIR ORIGINAL WNDITION. REFER TO THE ARCHRECTURAL DOWMENT$ FOR EKACT SPECIFlCATION REQUIREMENTS. PATCH FLOOR TO ORIGINAL CONSTRUCTION SPEQFlCATIONS AND U.L FlRE RATMG LISiINGS FOR ALL FLOOR IAOUMED DEVICES SUCH AS FLOOR BOXES, (FlRE RATED) POKE—iHR0UGH5, ETC. WHICH HAVE BEEN REMOVED. 14. ALL EQUIPMENT AN�/OR DEVICES THAT ARE REMOVED AN� NOT RE—USED SHALL BE TURNED WER TO THE TENANT AND/OR BUILDING IAANAGEMENT OR DISPOSED OF PER THEIR DIRECTION. 15. ALL MATERIAL TO BE DISPOSED SHALL BE �ONE UNDER STRICT ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL CODE REOUIREMENiS. DEMOLITION PLAN CODED NOTES: xx � CIRWITING SERVING QUAD RECEPTACLES ARE TO BE MAINTAINED FOR FUTURE USE. REFER TO SHEEf E3-1 FOR MORE INFORMATION. �2 PATCH CORE DRILL TO ORIGINAL FLOOR SPEGFICATIONS AND FIRE RATING. Q SECURItt CAMERA TO BE RELOCATED. SECURItt VENDOR TO EXTEND/REWORK CONDUIT AS REDUIRED. REFER TO SHEEf EJ-1 FOR MORE INFORMATION. PRO]EQ LOCATtON Key Plan: 0 4' 8' 16' \ \ i Scale: --- � - ConsWtant'. M ERRI LL � A BANK OF AM ERICA COMPANY ❑ient. INW-044 BofA Indianapolis MLWM Expansion & Refresh, 3rd Floor 510 96th Street Indianapolis, IN 46240 Projcct TiHc & Address: 3RD FLOOR ELECTRICAL POWER DEMOLITION PLANS SheetTiHe�. PE1180p515 �•�" •�, �• �o t STHTEOF ; ¢� %�'2. � Seal: Proj. No'. 19.0004]36.000 Designer'. ERO;MBM �rawn By: TGV Reviewed By: A1M Pmject Manager'. M]L qppmved By: NM E1-1 na mwems�orvs nmo mmo�r�oms wusr oe cHecKeo nrvo vea�F�eo ON 9TE BY THE CONTRAQOP AND 50B-CONTRAQORS PRIOR TO PEFFOkMMG THE WOFK. THE PRO]ECT MHNAGEk SHALL RE NOTIFIED IN WNIIINC OI ANYIJISCNtVBNCItS VNION 10 VHOCttIJINC WIIH IHt WOHK. � rve�sory won�owroe, uczozo nu a�sHTs aeseaveo �� 3RD FLOOR ELECTRICAL POWER DEMOLITION PLAN