Loading...
HomeMy WebLinkAboutM1-1�Inre��arcd 1�Engineenn� Consultan2s,lnc. 9700 ROCNSIDE RD. SUITE 790 CLEVELAND,OX 44125 PHONE:1169014711 FAX:216901�6712 NELSOI� Nelm Architedure, Inc. a licensed affliate 30 West Monroe Street - Suite 200 Chicago, IL 6060&2409 Phone: (312�263-6605 (312) 216L340 3RD FLOOR MECHANICAL HVAC DEMOLITION PLAN va.. = r-n„ 3RD FLOOR MECHANICAL HVAC DEMOLITION PLAN ira.. _ i._�.. MECHANICAL HVAC DEMOLITION PLAN GENERAL NOTES: 1. MECHANICAL HVAC CONTRACTOR SHALL COORDINATE ANY NECESSARY SHUTDOWNS WITH BUIL�ING/MANAGEMENT. 2 MECHANICAL HVAC CONTRACTOR SHALL PERFORM A FlEL� SURVEY PRIOR TO COMMENCING WITH DEMOLITION. NOTIFY ARCHRECT/ENGWEER OF ANY DISCREPANCIES FOUND FOR DIRECiION PRIOR TO COMMENCMG WITH DEIAOLITION. 3. ANY E%ISTING SYSTEMS AND/OR EQUIPMENT NOTED AS E%ISTING TO REMAIN SHALL BE FIELD VERIFIED FOR DEFICIENCIES. NOTIFY ARCHITECT AND ENGWEER OF ANY DEFICIENCIES DISCOVERED. 4. E%ISTING EQUIPMENT TO BE RELOCATED SHALL BE INSPECTED PRIOR TO RELOCATION. NOTIFY ARCHITECT AND ENGINEER OF ANY DEFICIENCIES DISCOVERED. 5. MECHANICAL HVAC CONTRACTOR SHALL REFER TO ALL SHEEfS CONTAINED IN DRAWING SEf FOR COMPLETE SCOPE OF WORK. ttPICAL DEfAILS, INSTALLATION REOUIREMENTS AND GENERAL BWLDING STANDARDS ARE REFERENCED AND APPLICABLE TO THESE CONTRACT DOCUMENTS. 6. IT IS THE INTENT TO REUSE DUCiWORK WHERE PRACTICAL WNTRACTOR MAY REUSE �UCT TAPS OF EQUAL SIZE. ANY EXISTING WNDITIONS THAT VARY SHALL BE BROOGHT TO THE ATfENTION OF THE ARCHITECT/ENGINEER PRIOR TO FABRICATION OR INSTALLATION OF NEW HVAC SYSTEMS. MECHANICAL HVAC DEMOLITION PLAN CODED NOTES:OO � RELOCATE E%ISTING DEFUSSER/GRILL. QQ RELOCATE EXISTING THERMOSTAT. QQ REMOVE EXISTING �UCPNORN TO THE POINT IN�ICATE� ON �RAWING. � REMOVE ALL HVAC EQUIPMENT FROM THIS PRIVATE OFFICE AREA WITHOUT AFFECTING SERVICE TO A�JACENT OFFlCES. OWNER'S PROJECT MANAGER ]ones Lang LaSalle Alex Cisneros 590 W. Madison St, Suit eIL4-590-04-55 Chicago, IL 60661 T: 773.502.5562 E: alex.cisneros@am.jll.com MEPENGINEER Integrated Engineering Consultants, Inc (IEC) Tlm Vining 9700 Rockside Road, Suite 290 Cleveland, OH 44125 L 216.901.67ll E: tim.vining@lec-inc.cc GENERALCONTRACTOR Mid America Contracting, Inc. Tyler Crawford 107 N. Main Street, Suite 3A Columbia, IL 62236 T: 618.9779255 E: tic@midameriwcontracting.com ConsWtant MERRILL� A BANK OF AMERICA COMPANY Client INW-044 BofA Indianapolis MLWM Expansion & Refresh, 3rd Floor 510 96th Street Indianapolis, IN 46240 PmjeQ TiHe & Fddress: 3RD FLOOR MECHANICAL DEMOLITION HVAC PLANS SheetTiHe: PE118005�5 •� ;• �o �t STATE OF : o- / W 2. / Seal: RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel � �u't1��i �JYV;�If}A�,, DATE: Qrj�Q�j�2O PROJEC�LOCATION Key Plan: 4 8�16 � 5cale'. Pmj.No: 19A�04]36�00 Designee ERO;MBM �rawn By: BRP Revicwctl By. HHH Pmjcct Managcr. MJL qpproved By: HHH M1-1 ALL �IMENSIONS AN� LON�ITIONS MI14 BE p1ELKED AND VEFIFIE� ON SRE 6Y THE CONTRPQOF AND SUB-CONTRAQOPS PNIOR TO FCRFORMING TI IC WOPK. TI IC PROJCR MANAGCR SI IALL 9C NOTIFlC� IN W WTIN6 OF ANV �ISCREPANC[ES PFIOR TO PROCEE�ING WRH THE WORK. Oc NELSON WOkLDWIDE, LLC IDID ALL RiGlf15 kESERVED �ias. �s..czx —