Loading...
HomeMy WebLinkAboutA1-12 � z v / 5 � �< � / � 0 0 � vl / 0 e 0 s w / � / a / ¢ � / $ / £ / L o� ¢ z �� / ¢ z 3 s 0 �/ w/ 3 /f a / a / a ll Al E a `O 3 E L f� z u i a ALIGN � � �i 3RD F 1�q.. _ 1._Q�, C�'1 � ► I � :7e1 �K�] ► � � :7aC� f�] . PLAN - PHASE II OPEN OFFICE 03.101 1 CONF � % �. / / /� COFFEEBAR �� WB / 104 � 03.105 we ALiGN / � ¢� 103 U ` � 9A ��� � � 03.105 OFFICE wa � � /� I:���Z�]�Ej1�31��11�'! PEft �IREQION FROM CBRE/1LL, HLTHOUGH THE GC IS NOT RESPONSIBLE FOR PRONRING THE PRODlIQS BELOW, THE GC IS RESPONSIBLE FOR ASSIST W G W ITH SCHEDULING AND MANAG W G THESE BACVENDORS • TYCOSENRIT' • TECHNOLOGV�TBOD) . CABLINGVENDOR • AV • BRFNDING . ART • KNOLL& OTHERFURNiTURE-CORVORATECONCEVTS • CFRPET,RESILIEMFLOOR&RESILIENTBFSE-TNNDUS PER �IREQION FNOM CBRE/1LL, THE GC IS RESVON518LE FOR PRONRIN6 PRO WQS FROM AND SCHEDULING & MANNGINGTHESEBACVENDORS: • �EMOUNTABLEOFFlCEFRONTDEALER . TELAIDWHRESOUN� RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel � �u't1�\i �JYv;�IRA�� . DATE: Qrj�Q�j�20 CONSTRUCTION PLAN LEGEND: NOT IN CONTRnQ EXISrMG PFRTifION TO REMAIN NEW CONSTRULTION ROOMNNME ROOMN ROOMTHG E CENTERLINE �� EXISRNG DOOR TO REMAM WB � FlRE RETARDANT WALL BLOCKING; IN-WALL FOR NEW PARTITIONS;SURFACE MOUNTED,FIMSHED 6RNDE (OPTIONNL) FOR EXISTING PARTITIONS PNRTRION TVPE KEYNOTES: � 100. RELOCATED WOOD DpOR, FRAME & 61A55 FRONT SVSfEM. 101. PROVIDE AND INS�ALL NEW WATERLINE CONNEQION FOR APPLIANCES. SEE EQUIPMENT PL4N FOR APPLINIVCE SPECIFlCATION NND ENGINEERIN6 DRAWIf FOR DETAILS. 1W. NEW RECESSED FEC UBINET; REFER TO EQUIPMENT SCHEDULE (AN-5) AN� PARTITION TVPES (AS-1) FOR Fl1RTHER MFO. 103. RELOCATED DOOR, FRAME AND HARDWARE. 104. RELOCATED 6LASSFRONT SVSTEM;RECONFIGUREAS REQUIRED. % WB CONFERENCE 03201 � j/OFFICE / xxxx / /j --------_� /////// 1/a" = 1'-0" CONSTRUCTION PLAN GENERAL NOTES 1. CONFLIQS BEfWEEIV SITE CONDITf01V5 FND DRNWIIV65 SHALL 8E BROUGHT TO THE IMMEDIFTE FTTENTION OF THE NRCHITEQ. L ALL WORK SHALL BE ERELTED NND INSTHLLED PWMB, LEVEL, SQUARE HND TRUE AND IN PROPER HLIGNMENT, U.N.O. 3. ALL DIMENSIONS ARE TO FINISH CONSTRUQION, U.N.O. DIMENSIONS NOiED "HOLD" MUSr BE ACCUR4TELY MNINTAMED, AND SHNLL NOT VARY MORE THAN t 1/8" WITHOUT WRITTEN INSTRUQION FROM ARCHIIEQ. "ALIGN" MEANS TO ACNRATELY LOCATE FINISHED FACES IN THE SAME PLANE. DIMENSIONS NOTED'YLEAR" ARE MINIMUM DIMENSIONS WHICH MUST BE MNIfYrAINED WITHOUT EXCEPTION. DIMENSIONS MARKED t MEAN A VARIANCE NOT GREATER THHN 1 INCH, VERIFY DIMENSIONS EXCEEDW6 TOLERANCE WITH THE ARCHITEQ. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE Fm6H FnCE OF WALL BELOW SILL, LLN.O. 4. ALL IXISTING FLOORS, PARTITIONS, DEMISMG WALLS, AND CORRIDOR WALLS TO REMAW ARE TO BE PATCHED AND REPAIRED TO MATCH ADJACENT SURFACES. 5. PATCH AT FLL NEW AND EXISTING PEIVEfRHTIONS AT FLOOR AND CEILIIV6 SLABS, WALLS FND SHARS, SFAL NBANDONDED GENEfR4T10N5 AT FLOORS, WALLS AND SHAFfS TO MHINTAM FIRE/SMOKE AND ACOUSTICAL RATINGS. PATCH FIREPROOFING AT ALL NEW AND EXISTING LOCATIONS WITH EXPOSED SfRUQURAL SrEEL. 6. ALL GL455 SHALL BE CLEAR TEMPERED. GL4ZING TONG MARKS SHNLL NOT BE VISIBLE. CLFAN & POLISH ALL GLA55 PRIOR TO PRO]ECT DELNERY. Z ALL MFILL OF DOORS/WALLS/OPENINGS SHFLL MATCH AND BE FLUSH WITH EXISfIN6 AD]ACENT PARTITION CONSrRl1CrION. 8. WHERE PARTITIONS ARE HTTHCHED TO CURTAM WALL, CENTER PHRTRIONS ON WINDOW MULLIONS, PERPENDICULAR TO PERIMETER WALL, U.N.O. WNSTRUQION TO MNTCH BUILDING STNNDFRD, 9. PARTITION DEPTH AT FIRE E%TINGUISHER CABINET LOCNTIONS SHNLL ACCOMMODATE FULL CONCEALMENT OF RECESSED CABINETS OR PARTIAL CONCEALMENT OF SEMI-RECESSED CABINETS AS SPEQFIED BV THE MANUFAQURER. 10. ALL PARTITfONS NBUTT[NG COLUMNS NRE TO NLIGN WITH THE FFCE OF THE CO W MN, U.N.O. 11. WHERE NEW PARTITIONS ABUT EXISTM6 SURFACES, REMOVE EXISfIN6 CORNER BEA� AND PROVIDE SMOOTH FMISH AT INTERSECTION. 12, nLL GVPSUM BOARD PAftTITI0N5 SHALL BE TAPED AND SANDED SMOOTH WITh' NO VISIBLE JOINTS. PROVIDE LEVEL 9 FMISH, U.N.O. 13. ALL EXPOSED 6VPSUM BOARD ED6E5 TO HAVE METAL EDGE TRIM. 14. WNTRACTOR SHALL COORDINATE REVIEW OF THE PARTITION LAVOUT WITH THE ARCHIfECT PRIOR TO PNRTIDON INSrALLNTION. 15. ACOUSTICAL(SOUNDd50LATI0N)PARTITIONSSHALL BESEALED FOR FULL HEI6HT TO PREVEIVT PASSA6E OF AIR80RNE SOUND. TNPE AND FIMSH FLL GYPSUM WALLBONRD JOINTS NND FN4ENER5 QNCLUDMG ABOVE SUSPENDED CEILING). CAULK AT PERIMETER AND SEAL AT ALL PENETRATIONS. 16. PROVIDE 6ROUNDS FND BLOCKIN6 IN MEfAL STUD WALL FRAMING FOR SUPPORT OF CASEWORK, SHELFSTNNDARDS, N/V DEVICES, FURNITURE, ETC. ALL CONCFALED LUMBER AND BLOCKIN6 TO BE FIRE TREATED. COORDINATE BLOCKIN6 REQUIREMENTS WRH FURNITURE & AV INSTALLERS. WHERE BLOCKIN6 OR ADDCfIONAL SNDS NRE REQUIRED AT EXISTING PARTITIONS, THEV NRE TO BE PATCHED AND REPAIRED.SEECONSTRUCTION PLANSFOR WALLMOUNTED MARKERBOARD, MONITORS & PROJEQION SCREENS; PROVIDE BLOCKIN6 PER MNNUFFQURERS'REQUIREMENTS. 1]. ALL WNGED DOORS TO BE 4" FROM NEAREST PERPENDINLNR PFRTITION, U.N.O. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF ]AMB. HLL DOORS SHNLL HAVE 1'-6" CLEFR ON THE STRIKE/PULL SIDE OF DOOR AND 1'-0 CLEAR ON THE STRIKE�PUSH SIDE (IF THEY HAVE BOTH A LATCH AND A CLOSER) VERIFV AND ADVISE ARCHREQ OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. 18. THE CONTRFGTOR SHNLL ESrABLISH F 9NGLE FLOOR ELEVATfON THAT IS TO BE USED TO SET THE TOP OF ALL DOORS SUCH THAT THE TOP OF ALL DOORS OF THE SFME HEIGHT WILL ALIGN REGARDLESS OF VARIATIONS IN THE FLOOR SLAB OR FINISHED FLOOR THICKNESS. 19. PROVIDE DOUBLE STUDS FT DOOR ]AMBS. INSrALL NDDIDONNL ST11D51N EXISRNG PARTITIONS HT NEW DOOR OPEMNGS M ORDER TO PROVIDE DOUBLE STUDS AT ]AMBS. 20. 6YPSUM WALLBOARD AT BOTH SIDES OF ALL PARTITIONS WITH PLUMBING ROUGH-IN (E.G.BATHROOMS, PFNTRY, ]ANITOR'S CLOSEf, WET COLUMNS) SHALL BE WATER-RESISTANT. SCOPENOTES A. NEW PARTIT[ON CONSTftUCrION TO BE 6" ABOVE CEILIN6 WITH 2y" OR 35/" MTL SNDS (TO MATCH EX6TING), SOUND BATT, %" GVP BOARD, SOUND BATT ABOVE CEILING TO EXTEND 2'-0" FROM EACH SIDE OF PFRTITION, UNO. B. REUSE EXISTING DOORS, FRAMES AND HNRDWARE AS NVAILNBLE IF REUSE OF EXISTING FRAMES & STOREFRONT IS NOT FEA96LE, PROVIDE PRICM6 TO CREATE NEW TO MATCH. �nca� aw�__' r -J �--+ L_� L_� Key Plan. aRo�Ecr �ocnnoN 4 6�16 � Scale: N E LSOI� Nelco Architecture, Inc. a licensed affiliate 30 West Monroe Street - Suite 200 Chicago,IL 60603-2409 Phona (312J263-6605 (312)2]6-4340 OWNER'S PRO]ECT MANAGER Jones Lang LaSalle Alex Cisneros 540 W. Madison St, Suit eIL4-540-04-SS Chicago, IL 60661 T: 77350L5562 E: alex.cisneros@am.jlLmm MEP ENGINEER Integrated Engineering Consultants, Inc (IEC) Tim Vining 9700 Rockside Road, Suite 290 Cleveland, OH 44125 T: 216.901.6711 E: tim.vining@ierinccc GENERALCONTRACTOR Mid America Contractinq, Inc. Tyler Crawford 107 N. Main Street, Suite 3A Columbia, IL 62236 T: 618.977.9255 E: tic@midamericacontracting.mm ConsulWnt: MERRILL�,i A BANK OFAMERICA COMPANY Client INW-044 BofA Indianapolis MLWM Expansion & Refresh, 3rd Floor 510 96th Street Indianapolis, IN 46240 Projec[ Title & Atltlress: 3RD FLOOR CONSTRUCTION PLAN Sheet Title: 0326.2020 5eal: Proj. Na: 19.0004]36.000 Designer. ERO;MBM Drawn By: ERO Reviewed By: M]L Projec[Manager. MJL Approvetl ey: VPD A1-1 nu o�wErvs�orvs arvo corvo�norvs nusT aE cnEaEo nrvo vEa�F�Eo oN ArE m'ine[orviun[ioenn�osu�{Omikneioxsvxiovio PERFORMING THE WOFK THE P0.0]KT MANAGER SHALL BE NOTIFIE� IN wwnrvc oF nrvr o�scaEanrvnEs aa�oa To aRocEEom� wrrry mE wonK. OO NEISON WORLDWIDE, LLC 2W0 nLL RIGMTS RESERVED