Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5958 Garden Gate Way truss packet
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. April 29,2020 Liu, Xuegang Pages or sheets covered by this seal: I41135527 thru I41135573 My license renewal date for the state of Indiana is July 31, 2020. 2000824-2000824A Yardley IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss A1 Truss Type ATTIC Qty 16 Ply 1 Yardley Job Reference (optional) I41135527 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:25 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-sXi03DtJ32zZn0aaTN9DD1YLltI?hK76ddVIJJzLu1a Scale = 1:82.2 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 22 19 21 20 23 24 4x6 5x9 4x6 8x16 3x6 6x8 4x6 5x6 10x10 1.5x4 1.5x4 4x6 6x12 MT20HS 5x6 5x6 4x4 12x12 4x4 2x4 6x10 4x6 4x6 4x6 6-9-12 6-9-12 13-4-1 6-6-4 15-9-4 2-5-3 16-5-4 0-8-0 22-8-0 6-2-12 28-2-12 5-6-12 28-10-12 0-8-0 30-8-0 1-9-4 6-9-12 6-9-12 13-4-1 6-6-4 15-9-4 2-5-3 16-5-4 0-8-0 22-0-0 5-6-12 22-8-0 0-8-0 28-2-12 5-6-12 28-10-12 0-8-0 30-8-0 1-9-4 2-8-011-6-1110-6-111-0-011-6-118.00 12 Plate Offsets (X,Y)-- [4:0-5-8,0-2-12], [9:Edge,0-4-0], [12:0-3-8,0-8-0], [15:0-3-8,0-6-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 1-4-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.56 0.87 0.80 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.38 -0.92 0.02 0.20 (loc) 12-14 12-14 23 14 l/defl >949 >397 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT20HS Weight: 330 lb FT = 20% GRIP 197/144 187/143 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x10 SP No.2 *Except* 10-13: 2x10 SP DSS WEBS 2x4 SPF No.2 *Except* 9-22,9-11: 2x6 SPF No.2 3-17,1-18,1-17,6-21,5-21,8-21: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-8-1 max.): 4-9. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 9-22, 3-15, 14-19, 12-20, 4-14, 9-23 JOINTS 1 Brace at Jt(s): 9, 19, 20, 21 REACTIONS. (size)18=Mechanical, 23=0-3-8 Max Horz 18=158(LC 12) Max Grav 18=973(LC 3), 23=1282(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1086/4, 3-4=-991/18, 4-5=-623/6, 5-6=-1149/128, 6-8=-1149/128, 8-9=-584/4, 11-22=-1766/28, 9-22=-1766/28, 1-18=-927/12 BOT CHORD 15-17=-116/882, 14-15=-35/783, 12-14=0/609 WEBS 4-15=-129/916, 1-17=0/843, 12-20=-682/139, 8-20=-605/147, 5-21=-136/543, 8-21=-134/737, 4-14=-844/191, 9-12=-33/3246, 9-23=-1284/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Ceiling dead load (5.0 psf) on member(s). 19-21, 20-21; Wall dead load (5.0psf) on member(s).14-19, 12-20 9) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 12-14 10) Refer to girder(s) for truss to truss connections. 11) Bearing at joint(s) 23 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 12) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 14) Attic room checked for L/360 deflection. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss A1G Truss Type GABLE Qty 1 Ply 1 Yardley Job Reference (optional) I41135528 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:28 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-H6O8hEwBMzL8eUJ98ViwqgAn74R7ur5YKbkzwezLu1X Scale = 1:80.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 39 20 3x6 3x6 3x6 4x4 4x4 4x4 4x4 4x4 6x12 MT20HS 4x6 5x6 5x6 5x6 3x6 2x4 15-9-4 15-9-4 28-2-12 12-5-8 30-2-8 1-11-12 30-8-0 0-5-8 13-4-1 13-4-1 15-9-4 2-5-3 22-0-0 6-2-12 28-2-12 6-2-12 30-8-0 2-5-4 2-8-011-6-118.00 12 Plate Offsets (X,Y)-- [10:0-3-0,0-0-2], [15:0-3-0,0-3-0], [27:0-3-0,0-3-0], [31:0-0-0,0-1-12], [31:0-3-0,0-1-4], [32:0-1-12,0-0-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-R 0.88 0.40 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.01 (loc) - - 20 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 MT20HS Weight: 259 lb FT = 20% GRIP 197/144 148/108 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 19-39: 2x6 SPF No.2, 1-38: 2x4 SPF Stud OTHERS 2x4 SPF No.2 *Except* 6-34,4-35,3-36,2-37: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 10-19. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 19-21, 15-25, 14-26, 13-27, 12-28, 11-29, 9-30, 8-32, 16-24, 17-23, 18-22 REACTIONS.All bearings 30-8-0. (lb) - Max Horz 38=330(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 25, 26, 27, 28, 29, 30, 32, 33, 34, 35, 36, 24, 23, 22 except 38=-858(LC 10), 20=-157(LC 11), 37=-1131(LC 9), 21=-121(LC 8) Max Grav All reactions 250 lb or less at joint(s) 20, 25, 26, 27, 28, 29, 30, 32, 33, 34, 35, 36, 24, 23, 22, 21 except 38=1263(LC 9), 37=855(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-518/339, 2-3=-252/165, 1-38=-611/403 WEBS 2-37=-355/474 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10) Gable studs spaced at 2-0-0 oc. 11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 26, 27, 28, 29, 30, 32, 33, 34, 35, 36, 24, 23, 22 except (jt=lb) 38=858, 20=157, 37=1131, 21=121. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 15) Attic room checked for L/360 deflection. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss G1G Truss Type Common Supported Gable Qty 1 Ply 1 Yardley Job Reference (optional) I41135529 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:31 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-hh4HJGy4fujiVx2jpdFdSIoTvIYK5C1_0ZydWzzLu1U Scale = 1:57.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 25 24 23 22 21 20 19 18 17 16 4x4 3x6 4x4 3x6 5x6 5x6 3x6 4x4 20-11-8 20-11-8 -0-10-8 0-10-8 10-5-12 10-5-12 20-11-8 10-5-12 21-10-0 0-10-8 0-10-09-6-130-10-010.00 12 Plate Offsets (X,Y)-- [2:0-3-15,0-0-2], [5:0-3-0,0-3-0], [11:0-3-0,0-3-0], [14:0-3-15,0-0-2] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.07 0.05 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 14 14 14 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 118 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud *Except* 8-20,7-21,9-19: 2x4 SPF No.2 SLIDER Left 2x6 SPF No.2 -H 1-6-0, Right 2x6 SPF No.2 -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-20 REACTIONS.All bearings 20-11-8. (lb) - Max Horz 2=-183(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 21, 23, 24, 19, 18, 17, 14 except 25=-120(LC 12), 16=-112(LC 13) Max Grav All reactions 250 lb or less at joint(s) 2, 20, 21, 23, 24, 25, 19, 18, 17, 16, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 21, 23, 24, 19, 18, 17, 14 except (jt=lb) 25=120, 16=112. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss G2G Truss Type Common Supported Gable Qty 1 Ply 1 Yardley Job Reference (optional) I41135530 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:33 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-d4B1ky_KBW_QkFB6x2I5XjtpR5E7Z7tHTtRjbrzLu1S Scale = 1:45.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 25 24 23 22 21 20 19 18 17 16 4x4 3x4 4x4 4x6 3x4 4x4 19-8-0 19-8-0 -0-10-8 0-10-8 9-10-0 9-10-0 19-8-0 9-10-0 20-6-8 0-10-8 0-8-07-2-110-8-08.00 12 Plate Offsets (X,Y)-- [21:0-0-0,0-1-12], [21:0-3-0,0-1-4], [22:0-1-12,0-0-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.07 0.02 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 14 15 14 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 94 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-6-0, Right 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-8-0. (lb) - Max Horz 2=-138(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 22, 23, 24, 25, 19, 18, 17, 16, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 20, 22, 23, 24, 25, 19, 18, 17, 16, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 22, 23, 24, 25, 19, 18, 17, 16, 14. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss M1 Truss Type Monopitch Supported Gable Qty 1 Ply 1 Yardley Job Reference (optional) I41135531 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:34 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-5GlPxI_yyp6HMPmIUmpK4xQuqVXCIZhQiXBH7IzLu1R Scale = 1:60.9 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 4x4 3x4 3x6 3x6 4x8 15-4-0 15-4-0 -0-10-8 0-10-8 15-4-0 15-4-0 0-8-010-10-118.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-0-3], [12:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.48 0.23 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 -0.00 -0.00 (loc) 1 1 12 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF Stud *Except* 10-13,9-14: 2x4 SPF No.2 SLIDER Left 2x4 SPF Stud -H 1-5-5 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 11-12, 10-13 REACTIONS.All bearings 15-4-0. (lb) - Max Horz 2=312(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 12, 2, 13, 14, 15, 17, 18, 19, 20 Max Grav All reactions 250 lb or less at joint(s) 12, 2, 13, 14, 15, 17, 18, 19, 20 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-322/206, 3-4=-259/169 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 2, 13, 14, 15, 17, 18, 19, 20. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss M2 Truss Type Monopitch Qty 6 Ply 1 Yardley Job Reference (optional) I41135532 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:36 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-2etAMz0CTRM?biwhcAro9MVDVJ8VmRSj9rgOCAzLu1P Scale: 3/16"=1' 1 2 3 4 5 6 9 8 71415 3x6 4x6 3x6 4x4 3x6 1.5x4 4x6 4x6 7-9-12 7-9-12 15-7-8 7-9-12 -0-10-8 0-10-8 7-9-12 7-9-12 15-7-8 7-9-12 0-8-011-1-00-3-811-1-08.00 12 Plate Offsets (X,Y)-- [2:0-3-5,0-0-3], [6:0-3-14,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.53 0.49 0.31 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.08 -0.20 0.02 -0.08 (loc) 7-9 7-9 2 7-9 l/defl >999 >935 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 71 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-9: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-7, 4-7 REACTIONS. (size)2=0-3-8, 7=0-3-8 Max Horz 2=319(LC 11) Max Uplift 2=-35(LC 12), 7=-133(LC 12) Max Grav 2=686(LC 21), 7=729(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-822/98 BOT CHORD 2-9=-106/666, 7-9=-106/666 WEBS 4-9=0/359, 4-7=-770/198 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 7=133. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss M3 Truss Type Monopitch Qty 2 Ply 1 Yardley Job Reference (optional) I41135533 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:37 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-WrRYaJ1rEkUsDsVtAuM1iZ2QPjTHVrDtOVPxkczLu1O Scale = 1:66.4 1 2 3 4 5 6 7 9 8 10 15 5x6 5x6 4x4 6x8 1.5x4 4x6 4x6 3x6 3x6 8-3-12 8-3-12 16-7-8 8-3-12 -0-10-8 0-10-8 5-7-11 5-7-11 10-11-13 5-4-3 16-7-8 5-7-11 0-8-011-9-07-11-611-9-03-4-28.00 12 5.00 12 Plate Offsets (X,Y)-- [2:Edge,0-0-0], [9:0-3-13,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.39 0.52 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.14 -0.39 -0.33 0.07 (loc) 8-9 8-9 15 8-9 l/defl >999 >509 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 82 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-9,6-9: 2x4 SPF Stud OTHERS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-9-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-8 REACTIONS. (size)2=0-3-8, 15=0-3-8 Max Horz 2=288(LC 9) Max Uplift 2=-9(LC 12), 15=-166(LC 12) Max Grav 2=713(LC 1), 15=662(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1664/217, 4-6=-1331/100, 8-10=-104/555, 7-10=-104/555 BOT CHORD 2-9=-364/1564, 8-9=-163/590 WEBS 4-9=-298/203, 6-9=-131/1178, 6-8=-829/215, 7-15=-664/168 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 15=166. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss M4 Truss Type Monopitch Qty 6 Ply 1 Yardley Job Reference (optional) I41135534 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:38 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-_1?wnf2T?2cjq044jbtGEmbZe6pKEIO0d99UG3zLu1N Scale = 1:66.8 1 2 3 4 5 6 7 9 8 4x6 5x6 4x4 6x8 1.5x4 4x6 4x6 3x6 8-3-12 8-3-12 16-7-8 8-3-12 -0-10-8 0-10-8 5-7-11 5-7-11 10-11-13 5-4-3 16-7-8 5-7-11 0-8-011-9-03-4-28.00 12 5.00 12 Plate Offsets (X,Y)-- [2:Edge,0-0-0], [7:0-3-14,Edge], [9:0-3-13,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.55 0.53 0.48 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.17 -0.45 0.18 0.10 (loc) 8-9 8-9 8 8-9 l/defl >999 >438 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 79 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-9,6-9: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-9-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 7-8, 6-8 REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=340(LC 11) Max Uplift 2=-35(LC 12), 8=-142(LC 12) Max Grav 2=713(LC 1), 8=697(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1667/241, 4-6=-1336/126 BOT CHORD 2-9=-335/1579, 8-9=-179/599 WEBS 4-9=-292/201, 6-9=-110/1197, 6-8=-837/207 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 8=142. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss M5 Truss Type Monopitch Qty 4 Ply 1 Yardley Job Reference (optional) I41135535 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:39 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-SDZI??25mMkaSAfGHJPVn_7klW94zp7Aspu2oVzLu1M Scale = 1:68.4 1 2 3 4 5 6 7 10 9 815 4x6 3x6 4x4 3x6 4x4 1.5x4 5x6 4x4 3x6 8-3-12 8-3-12 16-7-8 8-3-12 -0-10-8 0-10-8 5-7-11 5-7-11 10-11-13 5-4-3 16-7-8 5-7-11 0-8-011-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-1,0-0-3], [7:0-3-14,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.53 0.56 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.37 0.02 -0.10 (loc) 8-10 8-10 8 8-10 l/defl >961 >538 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 82 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-10: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 7-8, 6-8 REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=339(LC 11) Max Uplift 2=-37(LC 12), 8=-141(LC 12) Max Grav 2=713(LC 1), 8=778(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-857/118, 4-6=-730/141 BOT CHORD 2-10=-132/728, 8-10=-106/407 WEBS 4-10=-269/162, 6-10=-52/516, 6-8=-627/183 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb) 8=141. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss M6 Truss Type Monopitch Supported Gable Qty 1 Ply 1 Yardley Job Reference (optional) I41135536 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:40 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-wQ6gCL3jXfsR4KESr0wkKBgvJwa9iIaJ4TebLxzLu1L Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 12 21 20 19 18 17 16 15 14 13 3x6 4x4 4x4 3x4 4x4 3x6 16-4-0 16-4-0 -0-10-8 0-10-8 16-4-0 16-4-0 0-8-011-6-118.00 12 Plate Offsets (X,Y)-- [13:Edge,0-3-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.54 0.25 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 1 1 13 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 102 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF Stud *Except* 11-14,10-15,9-16: 2x4 SPF No.2 SLIDER Left 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 12-13, 11-14, 10-15 REACTIONS.All bearings 16-4-0. (lb) - Max Horz 2=332(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 13, 2, 14, 15, 16, 17, 19, 20 except 21=-105(LC 12) Max Grav All reactions 250 lb or less at joint(s) 13, 2, 14, 15, 16, 17, 19, 20, 21 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-319/207, 4-5=-259/168 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 2, 14, 15, 16, 17, 19, 20 except (jt=lb) 21=105. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss PB1 Truss Type Piggyback Qty 2 Ply 1 Yardley Job Reference (optional) I41135537 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:41 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-Ocg3Ph4LIz_HhUpePkRzsPCChKzoRmHSJ7N9tOzLu1K Scale = 1:13.6 1 2 3 4 5 6 4x4 2x4 2x4 1.5x4 5-6-15 5-6-15 2-9-8 2-9-8 5-6-15 2-9-8 0-4-71-10-50-1-80-4-70-1-88.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.05 0.04 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=4-1-1, 4=4-1-1, 6=4-1-1 Max Horz 2=-32(LC 10) Max Uplift 2=-25(LC 12), 4=-29(LC 13) Max Grav 2=120(LC 1), 4=120(LC 1), 6=143(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss PB2 Truss Type Piggyback Qty 18 Ply 1 Yardley Job Reference (optional) I41135538 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:42 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-soERd15z3H68JdNryRyCPclNRkGtACrcYn7iPqzLu1J Scale = 1:13.5 1 2 3 4 5 3x4 2x4 2x4 5-6-15 5-6-15 2-9-8 2-9-8 5-6-15 2-9-8 0-4-71-10-50-1-80-4-70-1-88.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.05 0.17 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 5 5 4 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=4-1-1, 4=4-1-1 Max Horz 2=-32(LC 10) Max Uplift 2=-19(LC 12), 4=-19(LC 13) Max Grav 2=192(LC 1), 4=192(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss PB3 Truss Type Piggyback Qty 15 Ply 1 Yardley Job Reference (optional) I41135539 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:43 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-L?opqN5bqaE?xny1W9TRxqIW47cgveDlmRsFyGzLu1I Scale = 1:39.1 1 2 3 4 5 6 7 8 14 13 12 11 10 916 15 3x6 3x4 3x6 17-4-0 17-4-0 9-5-0 9-5-0 17-4-0 7-11-0 0-4-76-1-136-3-50-1-80-10-80-1-88.00 12 Plate Offsets (X,Y)-- [5:0-3-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.19 0.14 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 0.00 0.00 (loc) 1 1 9 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 16-3-9. (lb) - Max Horz 2=128(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 13, 11 except 14=-115(LC 12), 10=-228(LC 13), 9=-147(LC 11) Max Grav All reactions 250 lb or less at joint(s) 2, 9 except 13=404(LC 20), 14=383(LC 20), 11=391(LC 25), 10=334(LC 25) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-14=-273/161, 7-10=-280/211 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 11 except (jt=lb) 14=115, 10=228, 9=147. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss PB4 Truss Type GABLE Qty 1 Ply 1 Yardley Job Reference (optional) I41135540 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:45 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-HNwZF27sMCUjA56QeZVv1FNtNxKgMYJ2EkLM09zLu1G Scale = 1:39.2 2 3 4 5 6 7 8 9 10 19 18 17 16 15 14 13 12 11 1 20 4x4 3x4 3x6 17-4-0 17-4-0 9-5-0 9-5-0 17-4-0 7-11-0 6-3-50-11-150-10-80-1-88.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.07 0.04 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-4-0. (lb) - Max Horz 1=127(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 17, 18, 19, 14, 13, 12 except 1=-109(LC 24) Max Grav All reactions 250 lb or less at joint(s) 1, 2, 16, 17, 18, 19, 11, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Bearing at joint(s) 20, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 17, 18, 19, 14, 13, 12 except (jt=lb) 1=109. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T1 Truss Type Common Qty 3 Ply 1 Yardley Job Reference (optional) I41135541 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:46 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-laUyTO8U7VcaoFhcBH18ZSw0WLa35zfBTO5vYbzLu1F Scale = 1:57.4 1 2 3 4 5 6 7 8 9 12 11 102122 4x6 4x8 4x4 3x6 4x4 1.5x4 4x4 1.5x4 4x8 4x4 7-1-0 7-1-0 13-10-8 6-9-8 20-11-8 7-1-0 -0-10-8 0-10-8 5-4-10 5-4-10 10-5-12 5-1-2 15-6-14 5-1-2 20-11-8 5-4-10 21-10-0 0-10-8 0-10-09-6-130-10-010.00 12 Plate Offsets (X,Y)-- [2:0-4-15,0-0-2], [8:0-4-15,0-0-2] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.24 0.41 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.12 -0.20 0.03 0.02 (loc) 10-12 10-12 8 12-15 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 97 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 6-10,4-12: 2x4 SPF Stud SLIDER Left 2x6 SPF No.2 -H 1-6-0, Right 2x6 SPF No.2 -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-183(LC 10) Max Uplift 2=-58(LC 12), 8=-58(LC 13) Max Grav 2=891(LC 1), 8=891(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-983/137, 4-5=-898/225, 5-6=-899/225, 6-8=-983/137 BOT CHORD 2-12=-85/791, 10-12=0/542, 8-10=-4/700 WEBS 5-10=-120/473, 6-10=-256/198, 5-12=-119/473, 4-12=-256/197 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T1R Truss Type Common Girder Qty 1 Ply 2 Yardley Job Reference (optional) I41135542 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:49 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-99945QAMPQ?9fiQBtParB5YOAYbUI89e9MJa9wzLu1C Scale = 1:58.5 1 2 3 4 5 9 8 7 61617181920212223 24 25 26 27 10x10 10x10 6x12 MT20HS 4x8 4x4 4x8 12x12 4x4 4x8 5-2-15 5-2-15 10-5-12 5-2-13 15-8-9 5-2-13 20-11-8 5-2-15 5-2-15 5-2-15 10-5-12 5-2-13 15-8-9 5-2-13 20-11-8 5-2-15 0-10-09-6-130-10-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-4-5], [2:0-0-8,0-1-12], [4:0-0-8,0-1-12], [5:0-1-8,Edge], [6:0-6-4,0-2-0], [7:0-6-0,0-6-4], [9:0-6-4,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.73 0.43 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.11 -0.29 0.05 0.01 (loc) 7-9 7-9 5 9 l/defl >999 >869 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT20HS Weight: 271 lb FT = 20% GRIP 197/144 187/143 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP DSS WEBS 2x4 SPF Stud *Except* 3-7: 2x4 SPF No.2 WEDGE Left: 2x8 SP No.2 , Right: 2x8 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8 (req. 0-6-14), 5=0-3-8 (req. 0-6-5) Max Horz 1=169(LC 11) Max Grav 1=8755(LC 3), 5=8064(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-9290/0, 2-3=-6564/0, 3-4=-6564/0, 4-5=-9242/0 BOT CHORD 1-9=0/7058, 7-9=0/7058, 6-7=0/7021, 5-6=0/7021 WEBS 3-7=0/8037, 4-7=-2733/0, 4-6=0/3306, 2-7=-2782/0, 2-9=0/3370 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) WARNING: Required bearing size at joint(s) 1, 5 greater than input bearing size. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 962 lb down at 0-4-4, 959 lb down at 1-4-4, 959 lb down at 2-8-4, 959 lb down at 4-0-4, 959 lb down at 5-4-4, 959 lb down at 6-8-4, 959 lb down at 8-0-4, 959 lb down at 9-4-4, 959 lb down at 10-8-4, 959 lb down at 12-0-4, 959 lb down at 13-4-4, 959 lb down at 14-8-4, 959 lb down at 16-0-4, 959 lb down at 17-4-4, and 959 lb down at 18-8-4, and 959 lb down at 20-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) StandardContinued on page 2 April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T1R Truss Type Common Girder Qty 1 Ply 2 Yardley Job Reference (optional) I41135542 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:49 2020 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-99945QAMPQ?9fiQBtParB5YOAYbUI89e9MJa9wzLu1C LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 10-13=-20 Concentrated Loads (lb) Vert: 8=-879(B) 7=-879(B) 9=-879(B) 12=-883(B) 16=-879(B) 17=-879(B) 18=-879(B) 19=-879(B) 20=-879(B) 21=-879(B) 22=-879(B) 23=-879(B) 24=-879(B) 25=-879(B) 26=-879(B) 27=-879(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T2 Truss Type Scissor Qty 2 Ply 1 Yardley Job Reference (optional) I41135543 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:50 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-dLjSImB_Ak70Gs?NQ754kI4dxysJ1htnN037hMzLu1B Scale = 1:45.8 1 2 3 4 5 6 7 8 9 10 6x6 4x4 4x6 8x8 1.5x4 1.5x4 6x6 4x4 9-10-0 9-10-0 19-8-0 9-10-0 -0-10-8 0-10-8 5-0-12 5-0-12 9-10-0 4-9-4 14-7-4 4-9-4 19-8-0 5-0-12 20-6-8 0-10-8 0-8-07-2-110-8-03-11-118.00 12 5.00 12 Plate Offsets (X,Y)-- [2:0-0-12,0-1-0], [8:0-2-3,0-1-0], [10:0-4-0,0-3-13] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.47 0.71 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.16 -0.47 0.34 0.09 (loc) 10-17 10-17 8 10 l/defl >999 >506 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 73 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 2-0-0, Right 2x4 SPF Stud -H 2-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-138(LC 10) Max Uplift 2=-64(LC 12), 8=-64(LC 13) Max Grav 2=839(LC 1), 8=839(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2088/237, 4-5=-1716/45, 5-6=-1716/67, 6-8=-2088/205 BOT CHORD 2-10=-242/1844, 8-10=-104/1829 WEBS 5-10=0/1480, 6-10=-360/272, 4-10=-360/245 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T2A Truss Type Scissor Qty 8 Ply 1 Yardley Job Reference (optional) I41135544 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:51 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-6XHrW6Cdx2Ftu0ZZ_qcJGWdovMCZm71xcgogEozLu1A Scale = 1:45.0 1 2 3 4 5 6 7 8 5x6 4x4 4x6 8x8 1.5x4 1.5x4 5x6 4x4 9-10-0 9-10-0 19-8-0 9-10-0 5-0-12 5-0-12 9-10-0 4-9-4 14-7-4 4-9-4 19-8-0 5-0-12 0-8-07-2-110-8-03-11-118.00 12 5.00 12 Plate Offsets (X,Y)-- [1:Edge,0-0-0], [7:Edge,0-0-0], [8:0-4-0,0-3-13] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.45 0.71 0.64 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.16 -0.47 0.34 0.09 (loc) 8-15 8-15 7 8 l/defl >999 >504 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 71 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 2-0-0, Right 2x4 SPF Stud -H 2-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size)1=0-3-8, 7=0-3-8 Max Horz 1=127(LC 11) Max Uplift 1=-48(LC 12), 7=-48(LC 13) Max Grav 1=787(LC 1), 7=787(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2105/250, 3-4=-1726/84, 4-5=-1726/84, 5-7=-2105/248 BOT CHORD 1-8=-261/1846, 7-8=-169/1845 WEBS 4-8=0/1492, 5-8=-367/269, 3-8=-367/244 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 1, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T3 Truss Type FLAT GIRDER Qty 1 Ply 2 Yardley Job Reference (optional) I41135545 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:54 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-W6zz87EVEzdRlTI8fyA0u8FCBZEyzR?NIe1Lq7zLu17 Scale = 1:36.7 1 2 3 4 5 6 12 11 10 9 8 7 13 14 15 16 17 18 19 20 6x6 4x6 6x6 5x12 MT18HS10x10 2x4 4x8 4x8 2x4 10x10 5x6 5x6 4-11-14 4-11-14 9-10-0 4-10-2 14-8-2 4-10-2 19-8-0 4-11-14 4-11-14 4-11-14 9-10-0 4-10-2 14-8-2 4-10-2 19-8-0 4-11-14 6-0-86-0-8Plate Offsets (X,Y)-- [1:0-1-12,0-2-8], [6:0-1-12,0-2-8], [9:0-4-12,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2012/TPI2007 CSI. TC BC WB Matrix-MSH 0.90 0.73 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.09 -0.22 0.04 0.05 (loc) 9-11 9-11 7 9-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 262 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF 1650F 1.5E WEBS 2x4 SPF No.2 *Except* 2-11,3-9,5-8: 2x4 SPF Stud BRACING- TOP CHORD 2-0-0 oc purlins (6-0-0 max.): 1-6, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)12=0-3-8 (req. 0-5-10), 7=0-3-8 (req. 0-5-8) Max Horz 12=-158(LC 32) Max Uplift 12=-434(LC 8), 7=-430(LC 9) Max Grav 12=7138(LC 3), 7=7024(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-12=-5588/379, 1-2=-4771/354, 2-3=-4771/354, 3-5=-4773/355, 5-6=-4773/355, 6-7=-5589/380 BOT CHORD 9-11=-436/6203, 8-9=-436/6203 WEBS 1-11=-448/7210, 2-11=-266/146, 3-11=-2186/162, 3-9=-94/3038, 3-8=-2183/160, 5-8=-265/147, 6-8=-448/7210 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) WARNING: Required bearing size at joint(s) 12, 7 greater than input bearing size. 10) Bearing at joint(s) 12, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=434, 7=430. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T3 Truss Type FLAT GIRDER Qty 1 Ply 2 Yardley Job Reference (optional) I41135545 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:28:54 2020 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-W6zz87EVEzdRlTI8fyA0u8FCBZEyzR?NIe1Lq7zLu17 NOTES- 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1284 lb down and 67 lb up at 0-8-12, 1280 lb down and 71 lb up at 2-8-12, 1280 lb down and 71 lb up at 4-8-12, 1280 lb down and 71 lb up at 6-8-12, 1280 lb down and 71 lb up at 8-8-12, 1280 lb down and 71 lb up at 10-8-12, 1280 lb down and 71 lb up at 12-8-12, 1280 lb down and 71 lb up at 14-8-12, and 1280 lb down and 71 lb up at 16-8-12, and 1282 lb down and 69 lb up at 18-8-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-6=-60, 7-12=-20 Concentrated Loads (lb) Vert: 11=-1231(F) 8=-1230(F) 13=-1235(F) 14=-1231(F) 15=-1231(F) 16=-1231(F) 17=-1230(F) 18=-1230(F) 19=-1230(F) 20=-1232(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T4 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 Yardley Job Reference (optional) I41135546 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:04 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-D1ZlEYMmt1u1y033F3LMIFf5gbofJ8OrbCSsAYzLu0z Scale = 1:65.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 3x6 4x6 3x6 3x6 4x4 3x6 31-8-0 31-8-0 14-9-0 14-9-0 20-3-15 5-6-15 31-8-0 11-4-1 0-8-010-6-02-11-510-6-08.00 12 Plate Offsets (X,Y)-- [4:0-2-2,0-0-0], [5:0-2-0,0-2-4], [5:0-0-0,0-1-12], [10:0-3-0,0-0-2], [13:0-2-0,0-2-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-R 0.13 0.07 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 20 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 195 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF No.2 *Except* 6-34,4-35,3-36,2-37,16-23,17-22,18-21: 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 10-13. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-26, 12-27, 11-29, 9-30, 8-31, 14-25 REACTIONS.All bearings 31-8-0. (lb) - Max Horz 38=224(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 20, 26, 27, 29, 30, 31, 32, 34, 35, 36, 25, 24, 23, 22, 21 except 38=-130(LC 8), 37=-104(LC 12) Max Grav All reactions 250 lb or less at joint(s) 38, 20, 26, 27, 29, 30, 31, 32, 34, 35, 36, 37, 25, 24, 23, 22, 21 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-9=-235/268, 13-14=-238/270 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 26, 27, 29, 30, 31, 32, 34, 35, 36, 25, 24, 23, 22, 21 except (jt=lb) 38=130, 37=104. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T5 Truss Type Piggyback Base Qty 6 Ply 1 Yardley Job Reference (optional) I41135547 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:07 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-ecFutaOfAyGbpToewBv3wuHYcpg9WPaHIAgXntzLu0w Scale = 1:62.4 1 2 3 4 5 6 7 13 12 11 10 9 81819202122 4x6 4x4 5x6 5x6 4x4 3x6 4x6 1.5x4 4x8 4x4 4x4 4x6 3x6 7-6-4 7-6-4 14-9-0 7-2-12 23-7-4 8-10-4 31-8-0 8-0-12 7-6-4 7-6-4 14-9-0 7-2-12 20-3-15 5-6-15 25-10-4 5-6-4 31-8-0 5-9-12 0-8-010-6-02-11-510-6-08.00 12 Plate Offsets (X,Y)-- [1:0-3-4,0-0-3], [4:0-3-0,0-2-3], [5:0-3-12,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.41 0.72 0.48 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.23 -0.42 0.08 0.05 (loc) 9-11 9-11 8 13-16 l/defl >999 >899 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 152 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-13,6-9,7-8: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-6-9 max.): 4-5. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-11, 6-8 REACTIONS. (size)1=0-3-8, 8=0-3-8 Max Horz 1=222(LC 11) Max Uplift 1=-75(LC 12), 8=-53(LC 13) Max Grav 1=1299(LC 19), 8=1312(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1855/224, 3-4=-1355/245, 4-5=-1043/252, 5-6=-1305/271 BOT CHORD 1-13=-141/1591, 11-13=-141/1591, 9-11=-8/945, 8-9=-33/975 WEBS 3-13=0/279, 3-11=-636/190, 4-11=0/411, 5-11=-65/308, 5-9=-74/334, 6-8=-1390/96 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T6 Truss Type Piggyback Base Qty 5 Ply 1 Yardley Job Reference (optional) I41135548 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:11 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-WNUPixR9EBm1I55P91z?4kSEeQ2TSDktCnekwezLu0s Scale = 1:62.3 1 2 3 4 5 6 7 13 12 11 10 9 81819202122 4x6 4x4 5x6 5x6 4x4 3x6 4x6 1.5x4 4x8 4x4 4x4 4x6 3x6 7-6-4 7-6-4 14-9-0 7-2-12 23-5-0 8-8-0 31-5-0 8-0-0 7-6-4 7-6-4 14-9-0 7-2-12 20-3-15 5-6-15 25-8-12 5-4-12 31-5-0 5-8-4 0-8-010-6-03-1-510-6-08.00 12 Plate Offsets (X,Y)-- [1:0-3-4,0-0-3], [4:0-3-0,0-2-3], [5:0-3-12,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.40 0.70 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.39 0.07 0.05 (loc) 9-11 9-11 8 13-16 l/defl >999 >974 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 151 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-13,6-9,7-8: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-7-2 max.): 4-5. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 3-11, 5-9, 6-8 REACTIONS. (size)1=0-3-8, 8=Mechanical Max Horz 1=224(LC 11) Max Uplift 1=-75(LC 12), 8=-51(LC 13) Max Grav 1=1284(LC 19), 8=1300(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1828/222, 3-4=-1330/243, 4-5=-1022/251, 5-6=-1262/267 BOT CHORD 1-13=-141/1569, 11-13=-141/1569, 9-11=-11/923, 8-9=-33/933 WEBS 3-13=0/280, 3-11=-634/190, 4-11=0/397, 5-11=-65/314, 5-9=-70/308, 6-8=-1362/95 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T7 Truss Type Piggyback Base Qty 5 Ply 1 Yardley Job Reference (optional) I41135549 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:14 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-wyAXLzT2X68c9Yq_q9XiiM4lxd3BfaVJvltOXzzLu0p Scale = 1:62.7 1 2 3 4 5 6 7 8 14 13 12 11 10 91920212223 5x6 5x6 4x4 4x6 4x4 3x6 4x6 1.5x4 4x8 4x4 4x4 4x6 3x6 7-6-4 7-6-4 14-9-0 7-2-12 23-5-0 8-8-0 31-5-0 8-0-0 -0-10-8 0-10-8 7-6-4 7-6-4 14-9-0 7-2-12 20-3-15 5-6-15 25-8-12 5-4-12 31-5-0 5-8-4 0-8-010-6-03-1-510-6-08.00 12 Plate Offsets (X,Y)-- [2:0-3-5,0-0-3], [5:0-3-0,0-2-3], [6:0-3-12,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.40 0.70 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.21 -0.39 0.07 0.05 (loc) 10-12 10-12 9 14-17 l/defl >999 >974 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 153 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-14,7-10,8-9: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (5-7-3 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-12, 6-10, 7-9 REACTIONS. (size)2=0-3-8, 9=Mechanical Max Horz 2=231(LC 11) Max Uplift 2=-90(LC 12), 9=-51(LC 13) Max Grav 2=1333(LC 20), 9=1300(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1824/220, 4-5=-1329/242, 5-6=-1021/250, 6-7=-1261/266 BOT CHORD 2-14=-140/1565, 12-14=-140/1565, 10-12=-11/923, 9-10=-33/933 WEBS 4-14=0/279, 4-12=-630/189, 5-12=0/396, 6-12=-65/313, 6-10=-70/308, 7-9=-1361/94 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T8 Truss Type Piggyback Base Qty 2 Ply 1 Yardley Job Reference (optional) I41135550 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:16 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-tLIHmfVI3jOKOs_NyaZAnn9_mRi_7V0cM3MVbszLu0n Scale = 1:66.6 1 2 3 4 5 6 7 8 14 13 12 11 10 91920212223 7x12 MT18HS 4x6 3x4 3x6 4x4 3x6 4x6 1.5x4 4x4 4x8 4x4 6x12 MT20HS3x6 7-6-4 7-6-4 14-9-0 7-2-12 20-3-15 5-6-15 30-8-0 10-4-1 -0-10-8 0-10-8 7-6-4 7-6-4 14-9-0 7-2-12 20-3-15 5-6-15 25-4-4 5-0-4 30-8-0 5-3-12 0-8-010-6-03-7-510-6-08.00 12 Plate Offsets (X,Y)-- [2:0-3-5,0-0-3], [5:0-8-8,0-1-12], [6:0-3-12,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-AS 0.89 0.87 0.40 DEFL. Vert(LL) Vert(TL) Horz(TL) Wind(LL) in -0.37 -0.81 0.07 0.05 (loc) 9-10 9-10 9 14-17 l/defl >999 >451 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT20HS MT18HS Weight: 152 lb FT = 20% GRIP 197/144 148/108 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-14,8-9: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 4-12, 5-10, 7-9 REACTIONS. (size)2=0-3-8, 9=0-3-8 Max Horz 2=237(LC 11) Max Uplift 2=-90(LC 12), 9=-47(LC 13) Max Grav 2=1302(LC 20), 9=1260(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1779/212, 4-5=-1257/240, 5-6=-880/229, 6-7=-1128/234 BOT CHORD 2-14=-139/1528, 12-14=-139/1528, 10-12=-56/1005, 9-10=-45/777 WEBS 4-14=0/309, 4-12=-657/183, 5-12=-44/532, 5-10=-279/96, 6-10=-27/375, 7-9=-1176/125 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss T9 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 Yardley Job Reference (optional) I41135551 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:20 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-l6Xob0Yp6yvltTH8BQe6xdKo32BS3NJCHhKjkdzLu0j Scale = 1:65.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 3x6 3x6 2x4 2x4 3x4 4x4 3x6 4x4 3x6 1-0-0 1-0-0 30-8-0 29-8-0 -0-10-8 0-10-8 14-9-0 14-9-0 20-3-15 5-6-15 30-8-0 10-4-1 0-8-010-6-03-7-510-6-08.00 12 Plate Offsets (X,Y)-- [12:0-3-0,0-0-2], [15:0-2-0,0-2-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.30 0.39 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.03 -0.00 (loc) 1 1-2 21 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 192 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF No.2 *Except* 8-34,6-35,5-36,4-37,18-23,19-22: 2x4 SPF Stud SLIDER Left 2x4 SPF Stud -H 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 12-15. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 15-26, 14-27, 13-29, 11-30, 10-31, 16-25 REACTIONS.All bearings 29-8-0. (lb) - Max Horz 37=235(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 21, 27, 29, 30, 31, 32, 34, 35, 25, 24, 23, 22 except 36=-257(LC 9), 37=-154(LC 8) Max Grav All reactions 250 lb or less at joint(s) 21, 26, 27, 29, 30, 31, 32, 34, 35, 36, 25, 24, 23 except 37=593(LC 21), 22=285(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 10-11=-222/256, 15-16=-224/259 WEBS 4-37=-274/95 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 27, 29, 30, 31, 32, 34, 35, 25, 24, 23, 22 except (jt=lb) 36=257, 37=154. 12) Non Standard bearing condition. Review required. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V1 Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135552 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:23 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-AhDxE2ahPtHKkx0jsYBpZGyNrFIwGl_ezfYNLyzLu0g Scale = 1:7.3 1 2 3 2x4 3x4 2x4 2-1-10 2-1-10 2-1-14 0-0-5 1-0-15 1-0-15 2-1-14 1-0-15 0-0-40-10-130-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.01 0.02 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-1-5, 3=2-1-5 Max Horz 1=11(LC 11) Max Uplift 1=-3(LC 12), 3=-3(LC 13) Max Grav 1=54(LC 1), 3=54(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V1A Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135553 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:24 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-etnJRObJAAPBM4bvQGi26TUXTfek?CunCJIwtOzLu0f Scale = 1:15.8 1 2 3 4 2x4 4x4 2x4 1.5x4 0-0-5 0-0-5 5-4-5 5-4-0 2-8-2 2-8-2 5-4-5 2-8-2 0-0-42-2-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.08 0.04 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-3-11, 3=5-3-11, 4=5-3-11 Max Horz 1=-37(LC 8) Max Uplift 1=-16(LC 12), 3=-21(LC 13) Max Grav 1=106(LC 1), 3=106(LC 1), 4=153(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V1B Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135554 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:25 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-64KhekcxxUX2zEA6_zDHeh1gb3yfkflxQz2UQqzLu0e Scale = 1:24.3 1 2 3 42x4 4x4 2x4 1.5x4 0-0-5 0-0-5 8-6-11 8-6-6 4-3-6 4-3-6 8-6-11 4-3-6 0-0-43-6-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.25 0.13 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-6-2, 3=8-6-2, 4=8-6-2 Max Horz 1=-63(LC 8) Max Uplift 1=-28(LC 12), 3=-36(LC 13) Max Grav 1=180(LC 1), 3=180(LC 1), 4=261(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V1C Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135555 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:27 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-2SSS3QdCT5nmDYKU5OGlk6619teWCZ?EuHXaUjzLu0c Scale = 1:29.9 1 2 3 4 5 8 7 63x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-5 0-0-5 11-9-2 11-8-13 5-10-9 5-10-9 11-9-2 5-10-9 0-0-44-10-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.18 0.10 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-8-8. (lb) - Max Horz 1=-88(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-138(LC 12), 6=-138(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=330(LC 23), 6=330(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-265/177, 4-6=-265/177 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=138, 6=138. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V1D Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135556 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:28 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-Wf0qHleqEPvdqiuhf5n_GJfCHGzGx?VN7xG809zLu0b Scale = 1:39.5 1 2 3 4 5 9 8 7 610113x4 4x4 3x4 3x6 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 14-11-3 14-11-3 14-11-8 0-0-5 7-5-12 7-5-12 14-11-8 7-5-12 0-0-46-2-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.15 0.13 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 50 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-10-14. (lb) - Max Horz 1=-114(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-135(LC 12), 6=-135(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 8=340(LC 19), 9=368(LC 23), 6=368(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-266/177, 4-6=-266/177 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=135, 6=135. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V2 Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135557 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:29 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-_raCU5fS?j1USsTtDpIDpXCOggKWgTTXLb0hZczLu0a Scale = 1:14.1 1 2 3 2x4 1.5x4 1.5x4 3-4-3 3-4-3 0-0-42-2-138.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.11 0.07 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-3-13, 3=3-3-13 Max Horz 1=54(LC 9) Max Uplift 1=-4(LC 12), 3=-23(LC 12) Max Grav 1=109(LC 1), 3=115(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V2A Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135558 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:30 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-S18aiRg4m09K4023mWpSLkkYi4gJPwjgaFlE52zLu0Z Scale = 1:15.6 1 2 3 2x4 1.5x4 1.5x4 3-9-11 3-9-11 0-0-42-6-78.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.16 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-9-5, 3=3-9-5 Max Horz 1=63(LC 9) Max Uplift 1=-5(LC 12), 3=-27(LC 12) Max Grav 1=127(LC 1), 3=134(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V3 Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135559 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:30 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-S18aiRg4m09K4023mWpSLkkaX4g2PwjgaFlE52zLu0Z Scale = 1:11.4 1 2 3 2x4 3x4 2x4 0-0-5 0-0-5 4-2-0 4-1-11 2-1-0 2-1-0 4-2-0 2-1-0 0-0-41-8-130-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.04 0.11 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-1-6, 3=4-1-6 Max Horz 1=-27(LC 10) Max Uplift 1=-7(LC 12), 3=-7(LC 13) Max Grav 1=134(LC 1), 3=134(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V3A Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135560 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:31 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-xEiyvnhiWKHBh9dFKEKiuyHjFU0d8NQppvVodUzLu0Y Scale = 1:21.3 1 2 3 4 2x4 4x4 2x4 1.5x4 0-0-5 0-0-5 7-4-6 7-4-2 3-8-3 3-8-3 7-4-6 3-8-3 0-0-43-0-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.17 0.09 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-3-13, 3=7-3-13, 4=7-3-13 Max Horz 1=-53(LC 8) Max Uplift 1=-24(LC 12), 3=-30(LC 13) Max Grav 1=152(LC 1), 3=152(LC 1), 4=221(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V3B Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135561 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:32 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-PQFL77hLHeP2JJCSuxrxQ9qqKuK8tp?z2YEL9wzLu0X Scale = 1:28.2 1 2 3 42x4 4x4 2x4 1.5x4 0-0-5 0-0-5 10-6-13 10-6-8 5-3-6 5-3-6 10-6-13 5-3-6 0-0-44-4-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.41 0.20 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=10-6-3, 3=10-6-3, 4=10-6-3 Max Horz 1=79(LC 9) Max Uplift 1=-35(LC 12), 3=-45(LC 13) Max Grav 1=226(LC 1), 3=226(LC 1), 4=328(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V3C Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135562 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:33 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-tcpjKTiz2xXvxTneSfNAzNM35HhzcG_6GC_viNzLu0W Scale = 1:36.5 1 2 3 4 5 8 7 63x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-5 0-0-5 13-9-3 13-8-14 6-10-10 6-10-10 13-9-3 6-10-10 0-0-45-8-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.15 0.10 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-8-10. (lb) - Max Horz 1=-105(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-127(LC 12), 6=-127(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=324(LC 19), 6=324(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-251/168, 4-6=-251/168 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=127, 6=127. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V3D Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135563 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:34 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-LpN5XpjbpFfmYdMq?MuPWavD8h0QLicGVsjSEpzLu0V Scale = 1:45.1 1 2 3 4 5 9 8 7 610113x4 4x4 3x4 3x6 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-5 0-0-5 16-11-10 16-11-5 8-5-13 8-5-13 16-11-10 8-5-13 0-0-47-0-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.19 0.15 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-11-0. (lb) - Max Horz 1=130(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-153(LC 12), 6=-153(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=351(LC 22), 9=444(LC 19), 6=444(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-302/200, 4-6=-302/200 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=153, 6=153. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V3E Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135564 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:36 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-HBVryUkrLswUoxWD7nwtb?_Z_VinpbFZyACZIizLu0T Scale = 1:52.8 1 2 3 4 5 6 7 13 12 11 10 9 83x4 4x4 3x4 3x6 0-0-5 0-0-5 20-2-0 20-1-11 10-1-0 10-1-0 20-2-0 10-1-0 0-0-48-4-130-0-410.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.17 0.16 0.19 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-1-6. (lb) - Max Horz 1=-156(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 13, 8 except 12=-140(LC 12), 9=-140(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=382(LC 22), 12=424(LC 19), 13=263(LC 19), 9=424(LC 20), 8=263(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-282/189, 5-9=-282/189 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 13, 8 except (jt=lb) 12=140, 9=140. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V3F Truss Type GABLE Qty 1 Ply 1 Yardley Job Reference (optional) I41135565 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:37 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-lO3EAqlT6A2LP45PhUR67DXlpv3PY2HiBqy6r8zLu0S Scale = 1:58.7 1 2 3 4 5 6 7 8 9 10 11 21 20 19 18 17 16 15 14 13 12 4x4 3x4 4x6 5x6 3x4 5x6 23-4-6 23-4-6 11-8-3 11-8-3 23-4-6 11-8-3 0-0-49-8-130-0-410.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-3-0], [9:0-3-0,0-3-0], [17:0-1-12,0-0-0], [18:0-3-0,0-1-4], [18:0-0-0,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-S 0.10 0.07 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.01 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 116 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud *Except* 6-16,5-17,7-15: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-16 REACTIONS.All bearings 23-4-6. (lb) - Max Horz 1=182(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 17, 19, 20, 15, 14, 13 except 21=-101(LC 12), 12=-101(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 16, 17, 19, 20, 11, 15, 14, 13 except 21=278(LC 19), 12=278(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 17, 19, 20, 15, 14, 13 except (jt=lb) 21=101, 12=101. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V4 Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135566 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:38 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-DadcNAm5tUAC1EfcECyLgQ4sMIN6HXirQUhgNazLu0R Scale = 1:21.3 1 2 3 2x4 1.5x4 1.5x4 5-4-3 5-4-3 0-0-43-6-138.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.37 0.23 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-3-13, 3=5-3-13 Max Horz 1=93(LC 9) Max Uplift 1=-7(LC 12), 3=-39(LC 12) Max Grav 1=189(LC 1), 3=199(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V4A Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135567 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:39 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-imB_bWnkenI3fOEoovTaDec?piiY0_y?f8RDv0zLu0Q Scale = 1:23.0 1 2 32x4 1.5x4 1.5x4 5-9-11 5-9-11 0-0-43-10-78.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.45 0.28 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-9-5, 3=5-9-5 Max Horz 1=102(LC 9) Max Uplift 1=-8(LC 12), 3=-43(LC 12) Max Grav 1=207(LC 1), 3=218(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V5 Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135568 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:40 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-AykMosoMP5QwGYp_Md?plr9Ez64clRG8toAmRTzLu0P Scale = 1:28.6 1 2 3 5 42x4 1.5x4 1.5x4 1.5x4 1.5x4 7-4-3 7-4-3 0-0-44-10-138.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.24 0.10 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-3-13, 4=7-3-13, 5=7-3-13 Max Horz 1=132(LC 11) Max Uplift 1=-9(LC 8), 4=-25(LC 9), 5=-99(LC 12) Max Grav 1=98(LC 20), 4=134(LC 23), 5=349(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-264/162 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V5A Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135569 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:40 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-AykMosoMP5QwGYp_Md?plr9DS64TlQB8toAmRTzLu0P Scale = 1:30.3 1 2 3 5 42x4 1.5x4 1.5x4 1.5x4 1.5x4 7-9-11 7-9-11 0-0-45-2-78.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.27 0.11 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-9-5, 4=7-9-5, 5=7-9-5 Max Horz 1=141(LC 9) Max Uplift 1=-5(LC 8), 4=-26(LC 9), 5=-105(LC 12) Max Grav 1=117(LC 20), 4=132(LC 19), 5=368(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-278/169 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb) 5=105. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V6 Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135570 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:41 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-e9Ik?Co_APYnuiOAwKW2I3iM3WPpUtxI6SwK_vzLu0O Scale = 1:36.6 1 2 3 5 462x4 1.5x4 1.5x4 1.5x4 1.5x4 9-4-3 9-4-3 0-0-46-2-138.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.41 0.17 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-3-13, 4=9-3-13, 5=9-3-13 Max Horz 1=172(LC 9) Max Uplift 4=-30(LC 9), 5=-128(LC 12) Max Grav 1=168(LC 20), 4=165(LC 19), 5=495(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-340/201 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=128. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V6A Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135571 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:42 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-6Ls7DYpcxigeWszNT21HqGEW5wkXDKxRL6ftWLzLu0N Scale = 1:38.3 1 2 3 5 462x4 1.5x4 1.5x4 1.5x4 1.5x4 9-9-11 9-9-11 0-0-46-6-78.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.45 0.20 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-9-5, 4=9-9-5, 5=9-9-5 Max Horz 1=181(LC 9) Max Uplift 4=-30(LC 9), 5=-136(LC 12) Max Grav 1=184(LC 20), 4=160(LC 19), 5=535(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-362/212 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=136. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V7 Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135572 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:43 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-aXQVQuqEi0oU7?YZ1lYWNUnf5J5Ryn0aZmPR2ozLu0M Scale = 1:43.1 1 2 3 4 7 6 53x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 11-4-3 11-4-3 0-0-47-6-138.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.63 0.16 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-3-13. (lb) - Max Horz 1=211(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 6=-104(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=441(LC 19), 7=296(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-277/158 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except (jt=lb) 6=104. April 29,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 2000824-2000824A Truss V7A Truss Type Valley Qty 1 Ply 1 Yardley Job Reference (optional) I41135573 8.330 s Mar 23 2020 MiTek Industries, Inc. Wed Apr 29 10:29:44 2020 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:xsM9xzKsFJAMJF8sac0w?5zO9LZ-2k_teErsSKwLl97lbS3lwhJtKjRfhD3koQ8_aEzLu0L Scale = 1:44.8 1 2 3 4 7 6 53x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 11-9-11 11-9-11 0-0-47-10-78.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2012/TPI2007 CSI. TC BC WB Matrix-P 0.40 0.16 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-9-5. (lb) - Max Horz 1=220(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 6=-102(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=436(LC 19), 7=318(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-273/156 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except (jt=lb) 6=102. April 29,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths