Loading...
HomeMy WebLinkAboutEL101 - LIGHTING PLANSM P M P CAM CAM CR 1 2 33 3 3 2 3 A 4 1 B 'L1'HOLLAND BUILDINGPARK EAST PARKING GARAGE8 8 GENERAL SHEET NOTES A. SEE SHEET E-000 FOR SYMBOLS AND ABBREVIATIONS. B. REFER TO E-500 SHEETS FOR ELECTRICAL SCHEDULES. C. REFER TO E-600 SHEETS FOR ELECTRICAL DETAILS. D. COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS, ARCHITECTURAL ELEVATIONS, MECHANICAL EQUIPMENT, DIFFUSERS, SUPPORTS, PIPING, DUCTWORK AND STRUCTURAL PLANS PRIOR TO ROUGH-IN AND INSTALLATION OF LIGHTS. E. ALL MOUNTING HEIGHTS NOTED ON THE PLANS ARE TO THE BOTTOM OF THE FIXTURES UNLESS NOTED OTHERWISE. F. LOCATE CEILING MOUNTED OCCUPANCY SENSORS TO PROVIDE COMPLETE AREA COVERAGE OF THE SPACE THEY ARE INSTALLED IN. SELECT PROPER SENSOR COVERAGE PATTERN FROM MANUFACTURER'S PRODUCT DATA TO DETERMINE COVERAGE. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND THE MANUFACTURER. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND RELAYS NECESSARY FOR PROPER OPERATION. G. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. H. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR DESIGNER. I. LABEL ALL RELAYS AND POWER SUPPLIES (ON THE DEVICE OR ON THE BOX THEY ARE CONNECTED TO) WITH THE AREA THE DEVICES SERVES, THE BRANCH CIRCUIT IT CONTROLS AND THE DEVICE ADDRESS (IF APPLICABLE). J. EMERGENCY LIGHTING SHOWN ON THIS DRAWING INDICATES CODE REQUIRED EMERGENCY LIGHTING FED FROM THE 'EMERGENCY BRANCH' OF THE ESSENTIAL ELECTRICAL SYSTEM. K. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE-RATED PARTITIONS, CABINET AND CASEWORK AND BUILT-IN DETAILS. L. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. M. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. N. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. O. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. 2 3 A 4 1 B 'L2''L2''L2''L2''L2''L2''L2'HOLLAND BUILDINGPARK EAST PARKING GARAGECIVIL, LIGHTING AND ELECTRICAL DESIGN CONSULTANTS HEATING, VENTILATION, AIR CONDITIONING, PLUMBING, FIRE PROTECTION, 9229 DELEGATES ROW SUITE 150 INDIANAPOLIS, IN 46240 (317) 781-6200 CIRCLE DESIGN GROUP 19092 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateHolland / Playfair BuildingsCarmel, IN 46032Construction Documents120 West Monon Green Blvd.EL101 LIGHTING PLANS 09/23/201909/23/2019 Barry SimpsonMelissa Laviolette 1/4" = 1'-0" SECOND FLOOR LIGHTING PLAN208'4'2' SHEET PLAN NOTES 1 CORNER MOUNT LINEAR DOWNLIGHT BETWEEN CEILING AND STEEL TUBE STRUCTURE WITH LUMINOUS SURFACES FACING OUT. FIXTURES TO BE MOUNTED END TO END WITH MINIMAL JOINTS. 2 CONNECT LIGHTING WITHIN SKYBRIDGE TO AN AVAILABLE 20A/1P CIRCUIT WITH IN PANELBOARD "2HA1" IN HOLLAND BUILDING. VERIFY AVAILABLE CIRCUITS PRIOR TO WORK. 3 LIGHT FIXTURES INSTALLED WITH REMOTE EMERGENCY BATTERY PACK AS INDICATED PER DRAWING. 4 JBOX MOUNTED FIXTURE RECESSED INTO UNDERSIDE OF BRIDGE. 5 EXISTING FIXTURE SHOWN FOR REFERENCE. 6 CONNECT LIGHTING UNDER SKYBRIDGE TO AN AVAILABLE 20A/1P CIRCUIT WITH IN PANELBOARD "2HA1" IN HOLLAND BUILDING. VERIFY AVAILABLE CIRCUITS PRIOR TO WORK. 7 BELOW CONNECTOR LIGHTING TO BE CONTROLLED WITH BUILDING MOUNTED LIGHTING ON HOLLAND BUILDING WITH PHOTOCELL AND TIMECLOCK BY WAY OF CONTACTOR. 8 SURFACE MOUNT SENSOR TO STRUCTURE/CEILING. LIGHTING FIXTURE SCHEDULE FIXTURE TYPE BASE MANUFACTURER EQUAL MANUFACTURER WATTAGE LAMP TYPE VOLTS MOUNT DESCRIPTION L1 AXIS: ED2S-800LM-80-30K-UB-S79-X-SC O-UNV-DP-1-SC-FL-B#4 ALW: NOVENTA, LUMIUM: NB3, LUMENWERX: CUBITO 7W/LF LED 800LM/FT 3000K 120 SURFACE 79' LINEAR LED DOWNLIGHT WITH ALUMINUM EXTRUSION & DIFFUSE LENS. MINIMIZE NUMBER OF FIXTURE JOINTS. CORNER MOUNT WITH (2) LUMINOUS SURFACES POINTED DOWN AND OUT. 80 CRI MIN. 0-10V DIMMING TO 10%. REMOTE EMERGENCY BATTERY PACK MOUNTED EVERY 18'-0" ON CENTER. 800LM/FT MIN. (SKYBRIDGE) L2 HALO: SMD6S-12-930-X-X PROVIDE ALLOWANCE OF $50 PER FIXTURE. 16 LED 1200LM 3000K 120 JBOX 6" JBOX MOUNTED LED DOWNLIGHT WITH DAMP LOCATION. TRIM FINISH PER ARCHITECT. FIXTURE TO MATCH HOLLAND BUILDING. (UNDERSIDE OF BRIDGE) NOTES: 1. FIXTURES LISTED IN THE EQUAL MANUFACTURER COLUMN TO BE PROVIDED WTIH COMPONENTS, PERFORMANCE, AESTHETIC, FABRICATION, AND CONSTRUCTION EQUAL TO OR BETTER THAN BASE BID. 2. MANUFACTURER TO PROVIDE ALL NECESSARY POWER SUPPLIES, MOUNTING ACCESSORIES, AND COMPONENTS TO FOR LIGHT FIXTURE TO OPERATE NORMALLY. 3. REFER TO ARCHITECTURAL/INTERIOR/SITE DRAWINGS FOR EXACT MOUNTING LOCATIONS, DETAILS, AND CONFIGURATION OF LIGHT FIXTURES. IF DRAWINGS DO NOT CLARIFY EXACT DETAILS, CONTRACTOR TO ISSUE RFI TO CLARIFY PRIOR TO FIXTURE ROUGH-IN. ELECTRICAL DRAWINGS SHALL NOT BE USED TO VERIFY LIGHT FIXTURE PLACEMENT. 4. CONTRACTOR TO VERIFY COMPATIBILITY OF LIGHT FIXTURES WITH CEILING MATERIALS, ADJACENT FINISHES, CONSTRUCTION AND MATERIALS PRIOR TO SHOP DRAWING SUBMITTAL. NOTIFY ARCHITECT OF ANY CONFLICTS WITH INSTALLATION. 5. CONTRACTOR RESPONSIBLE FOR ALL NECESSARY HARDWARE AND COMPONENTS REQUIRED TO INSTALL LIGHT FIXTURES. 6. SEISMIC PROTECTION OF ALL LIGHT FIXTURES SHALL COMPLY WITH SPECIFICATION SECTIOSN AND LOCAL CODES AND ORDINANCES. 1/4" = 1'-0" FIRST FLOOR LIGHTING PLAN108'4'2' 4 4 4 4 4 4 4 5 5 5 6 6 6 6 6 6 6 N N 7