Loading...
HomeMy WebLinkAboutEP101 - POWER PLANSCAM CAM J CR CAM CAM J CR FCU-1 FCU-2 2#8, #10GND-3/4"C 2#8, #10GND-3/4"C 2 1 21 3 3 2 3 A 4 1 B 5 5 6 7 7 A. SEE SHEET E-001 FOR SYMBOLS AND ABBREVIATIONS. B. SEE SHEET E-604 FOR KITCHEN EQUIPMENT SCHEDULE. C. SEE SHEET E-604 FOR MECHANICAL EQUIPMENT POWER SCHEDULE. D. SEE SHEETS E-601 THROUGH E-603 FOR PANEL SCHEDULES. E. SEE SHEETS E-501, E-502 AND E-503 FOR ELECTRICAL DETAILS. F. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. G. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR DESIGNER. H. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. I. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. J. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. K. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. L. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL INTERCONNECT WIRING FOR MECHANICAL AND PLUMBING EQUIPMENT FURNISHED BY OTHERS. GENERAL SHEET NOTES 2 3 A 4 1 B EWH-1EWH-1EWH-1 EWH-1 EWH-1 EWH-1 4 4 4 4 4 4 2#12, #12GND-3/4"C 2#12, #12GND-3/4"C 2#12, #12GND-3/4"C 2#12, #12GND-3/4"C 2#12, #12GND-3/4"C 2#12, #12GND-3/4"C CIVIL, LIGHTING AND ELECTRICAL DESIGN CONSULTANTS HEATING, VENTILATION, AIR CONDITIONING, PLUMBING, FIRE PROTECTION, 9229 DELEGATES ROW SUITE 150 INDIANAPOLIS, IN 46240 (317) 781-6200 CIRCLE DESIGN GROUP 19092 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateHolland / Playfair BuildingsCarmel, IN 46032Construction Documents120 West Monon Green Blvd.EP101 POWER PLANS 09/23/201909/23/2019 Barry SimpsonCarlston Elliott 1/4" = 1'-0" SECOND FLOOR POWER PLAN108'4'2' SHEET PLAN NOTES 1 PROVIDE A 60A DISCONNECT FOR FAN COIL UNITS FCU-1 AND FCU-2. CONNECT FAN COIL UNITS TO A 45A/2P CIRCUIT BREAKER WITH IN PANELBOARD "2HA1" LOCATED ON THE 2ND FLOOR OF THE HOLLAND BUILDING. 2 PROVIDE A 30A WEATHERPROOF DISCONNECT FOR CONDENSING UNITS CU-1 AND CU-2 LOCATED ON THE ROOF. CONNECT THE CONDENSING UNITS TO A 20A/2P CIRCUIT BREAKER WITH A WIRE SIZE OF 2#12,#12GND-3/4"C FED FROM PANELBOARD "4HA1" LOCATED ON THE 2ND FLOOR OF HOLLAND BUILDING. 3 PROVIDE A WEATHERPROOF (GFCI) RECEPTACLE ON CONDENSING UNIT LOCATED ON ROOF. CONNECT RECEPTACLES TO THE SAME 20A CIRCUIT AS RECEPTACLES WITH IN THE AREA FEDFROM PANEL "4HA1" LOCATED ON THE 4TH FLOOR OF HOLLAND BUILDING. 4 PROVIDE A 20A DISCONNECT FOR ELECTRIC WALL HEATERS "EWH-1". CONNECT ELECTRIC WALL HEATERS TO A 20A/2P CIRCUIT BREAKER WITH IN PANELBOARD "2HB1" LOCATED ON THE 2ND FLOOR OF THE HOLLAND BUILDING. 5 PROVIDE A WEATHERPROOF (GFCI) RECEPTACLE MOUNTED ON STEEL COLUMN. CONNECT RECEPTACLES TO THE SAME 20A CIRCUIT FED FROM PANEL "2HA1" LOCATED ON THE 2ND FLOOR OF HOLLAND BUILDING. 6 SKYBRIDGE PASSAGE/DOOR SECURED THROUGH ACCESS CONTROL SYSTEM FED FROM HOLLAND BUILDING. 7 ROUTE (1) CAT6 CABLE FROM HOLLAND BUILDING IDF ROOM LOCATED ON THE 2ND FLOOR AREA A TO SECURITY CAMERA. VERIFY LOCATION AND MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION. 1/4" = 1'-0" SECOND FLOOR POWER PLAN - ALTERNATE20 8'4'2'