HomeMy WebLinkAboutE102.6a. oi n � oi c o� e i o: m C C C C RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r ��n��\i l�•va�l,T�. DATE: Qrj�08�20 � �000 I � o0 � � ��'� \\\\\\�/'\ CZ--_ �� ''' ❑ 0 oo� � . i� V, i � \ �i / (N)BOND TO BUILDING STEEL (N)BOND TO EXISTING GROUND LOOP / \ � � _ � \ \ < � �� \� � j �m �_ cRou�do OoOO \ � ���0 00 O�oO � ���0 0 00 o O\ 0000 0� , 0 � C \ (N)BON� 70 EXISTING CONTROL ROOM GROUN� BAR (BELOW RAISE� PLOOR) . �� , � � O� O� \ �O 0 00 �� � ,. , d. � ao �(N)BOND ID EXISTING COMPUTER ROOM GROUND BAR (BELOW RA6ED FLOOR) � � � � 1 � F \ �\ � / �� �. � > � � �'`. � � (N)BOND TO EXISTI�yG ` UPS ROOIA GROUND \ " BAR ��_'''}}}���,,, � < /' � !�A � � ���% �� �QO � G� /�% / ,5� `�.%A✓ �6'.� '��� �� ��� L l�L' (� U� � O� �O O� e� 0 1L 3/32"=1 '-0" �� (N)BOND TO � �BUI�DING STEEL \ \ � (N)BOND TO EXISTING � GROUND LOOP �/< \ '� A � �(NfiPGDC GkD BUS l � � � GRD BUS i � i� \ \ � � BAR �� \ � � � \ \ \ \ \ /\ 9 � ! \ 5 \ V� � `� A _ �� � \ � �� S � � - \ -� \ � �� \ \�>-� � \ � � 1 � � \ � � �� � N \� \, � _. � � � � 1 1 (E)BOND TO GROUND �1�LOOP TO REMAIN N BOND' � ) TO '_li EXISTING DOMESTIC � - WATER MAIN � � ��� � � - � -� �, � � � ❑ �� C �� � � o �� 0 o�r, — �� ?������ (N)BOND TO EXISTING L4B GROUND BAR (BELOW RAISED FLOOR) C�. �� �� �� _ �, — u L � � o0 � c � � � � � � � GENERAL NOTES A. ALL NEW GROUND CONNECTIONS TO BE MADE BEFORE ENERGIZING EOUIPMENT. B. ALL EX6TING GROUND CONNECTIONS MUST REMAIN UNTIL OLD SWITCHGEAR IS DE-ENERGIZED AND DEMOL6HED IN ITS ENTIRETY. C. ELECTRICAL CONTRACTOR TO TRACE EXISTING GROUND CONNECTIONS AND VERIFY ALL EHISTING GROUND BARS AND GROUNDING ELECTRODES ARE BONDED TO NEW ELECTRICAL SERVICE AFTER DEMOLITION OF OLD SWITCHGEAR. D. LOCATIONS OF Ex15TING GROUNDING ELECTRODES AND GROUND BARS ARE TAKEN FROM HISTORICAL DRAWINGS. CONTRACTOR TO VERIFY LOCATION OF SYSTEMS BEFORE INSTALLING NEW. E. ALL ABOVE GROUND GROUNDING ELECTRODE CONDUCTORS TO BE STRANDED COPPER WITH GREEN WSULATION. F. ALL GROUNDING ELECTRODE CONDUCTORS THAT BOND UNDERGROUND SHALL BE BARE STRANDED COPPER. G. ALL GROUNDING ELECTRODE CONDUCTORS MUST BE CONTINUOUS, NO SPLICING ALLOWED. H. REFER TO GROUNDING DIAGRAM ON SHEET E3.0 FOR ADDITIONAL INFORMATION AND GROUNDING ELECTRODE CONDUCTOR SIZING. — CSW 4/16/20 PERMIT SET REV BY DATE �ESCRIPTION 8' 16' 32' 3/32'=P-0' PROJECT MISO 701 SWITCHGEAR REPLACEMENT MISO ,o��.�r��,����. Cartrnrnl. IN 46032 DRAWN BY: ORIGIN DATE: DESIGNED BY: JHB 12/20/19 CSW APPROVED BV: DATE CLIENT N0. JAK 2/10/20 1532 DRAWING NAME: E26-3395.DWG SEAL 5. dbb TechSite Y p rappmved mtssmo t I r rlrry expercs TechSit2 www.techsiteplan.com 8188 Business Way . Plain CiTy, Ohio 43064 t 614.873J800. f 614.873J801 DATE: 2/10/20 JOB N0. 3395 TITLE GROUNDING PLAN LAST EDIT DATE: DRAWING N0. 3/13/20 S�^�E E2.6 3/32" = 1'-0"