HomeMy WebLinkAboutGN010.22x6 x 41" Header (2)2x6 x 41" Header (2)
A7
OWNER:GUILFORD TRAILSECTION
DETAILS
INTEGRA BUILDERS
PROJECT NUMBER:
20001
DRAWN BY:
CC
DRAWING DATE:
4/29/2020
REVISION & DATE:
SCALE:
AS SHOWN
UL U350 2 HOUR
RATED FIRE
RATED LOAD
BEARING WALL
MIN. 1" AIR GAP
BETWEEN
ASSEMBLIES
FIREBLOCKED
2X4 STUDS @
MAX. 16" O.C.
MIN. 3.5" THK
MINERAL
WOOL INSUL.
5/8" TYPE X GYP BD.
APPLIED HORIZONTALLY
OR VERTICALLY. BOTH
ASSEMBLIES
SLAB ON
GRADE
THIRD FLOOR CLG.
UNDERSIDE OF
ROOF
GROUND FLOOR CLG.
SECOND FLOOR
CLG.
BUILDING SECTION
SCALE: 1/4"=1'
1
A7
1
A7
EXTEND FIREWALL
BLOCKING TO
UNDERSIDE OF ROOF
FIREWALL SECTION
SCALE: 1/2"=1' 22 BUILDING 8CARMEL, IN 46032SLAB ON
GRADE
16" FOOTER
BELOW FROST,
PER CODE
2X6" BRICK
EXTERIOR
WALL
TJI PER
SPECIFICATIONS
WALL SECTION
SCALE: 1/2"=1'33
TJI PER
SPECIFICATIONS
2X6" WOOD CLAD
EXTERIOR WALL
THICKENED SLAB,
PER CODE
MIN. 4" LEDGE ON FIRE
WALL FOUNDATION
(TYP.)
2X6 FRAMING ON
LOWEST LEVEL
2X4 FRAMING
2X4 FRAMING
2x4 WALL SHALL
BE CENTERED ON
2X6 WALL BELOW
SECTION & FIREWALL NOTES
1)NO FLOOR SHEATHING SHALL CONTINUE ACROSS A 2 HOUR RATED FIRE WALL.
2)5/8" TYPE X GYP. BD. IN GARAGE CEILINGS, AND WALLS.
3)5/8" TYPE X GYP. BD. INSIDE CAVITY OF BOTH FIRE WALL SIDES, FROM F.F.L. TO UNDERSIDE OF ROOF.
4)2 HOUR WALL AT ALL ROOF EVES SHALL BE FRAMED AND FIRE BLOCKED.
5)PENETRATIONS INTO FIRE SHALL BE MINIMIZED. WHERE PENETRATIONS DO EXIST, VOID SHALL BE FILLED WITH FIRE CAULK PER CODE.
FIREWALL SECTION AT EVE
SCALE: 1/2"=1'
2
A7
2
A7
2X FIREBLOCKING AT ALL
INTERSECTIONS WHERE FIREWALL
MEETS ROOF & EVE
2x RAFTER
5/8 TYPE X GYP. BD. ON
BOTH FACES OF 2
HOUR WALL
2X6" EXTERIOR
WALL
ROOF MATERIAL & SHEATHING
2x6 x 41" Header (2)
2
A7
2
A7
GARAGE
KITCHEN KITCHEN KITCHEN KITCHEN
GARAGE GARAGE GARAGE
3
A7
3
A7
2x6 x 41" Header (2)
5/8" TYPE X GYP BD.
APPLIED HORIZONTALLY
OR VERTICALLY. BOTH
ASSEMBLIES
5/8" TYPE X GYP BD.
APPLIED
HORIZONTALLY OR
VERTICALLY. BOTH
ASSEMBLIES
5/8" TYPE X GYP BD.
APPLIED HORIZONTALLY
OR VERTICALLY. BOTH
ASSEMBLIES
05/12/20