HomeMy WebLinkAboutGN010.2A7
OWNER:GUILFORD TRAILSECTION
DETAILS
INTEGRA BUILDERS
PROJECT NUMBER:
20001
DRAWN BY:
CC
DRAWING DATE:
3/11/2020
REVISION & DATE:
SCALE:
AS SHOWN
UL U350 2 HOUR
RATED FIRE
RATED LOAD
BEARING WALL
MIN. 1" AIR GAP
BETWEEN
ASSEMBLIES
FIREBLOCKED
2X4 STUDS @
MAX. 16" O.C.
MIN. 3.5" THK
MINERAL
WOOL INSUL.
5/8" TYPE X GYP BD.
APPLIED HORIZONTALLY
OR VERTICALLY. BOTH
ASSEMBLIES
SLAB ON
GRADE
THIRD FLOOR CLG.
UNDERSIDE OF
ROOF
GROUND FLOOR CLG.
SECOND FLOOR
CLG.
BUILDING SECTION
SCALE: 1/4"=1'
1
A7
1
A7
EXTEND FIREWALL
BLOCKING TO
UNDERSIDE OF ROOF
FIREWALL SECTION
SCALE: 1/2"=1' 22 BUILDING 8CARMEL, IN 46032SLAB ON
GRADE
16" FOOTER
BELOW FROST,
PER CODE
2X6" BRICK
EXTERIOR
WALL
TJI PER
SPECIFICATIONS
WALL SECTION
SCALE: 1/2"=1'33
TJI PER
SPECIFICATIONS
2X6" WOOD CLAD
EXTERIOR WALL
THICKENED SLAB,
PER CODE
MIN. 4" LEDGE ON FIRE
WALL FOUNDATION
(TYP.)
2X6 FRAMING ON
LOWEST LEVEL
2X4 FRAMING
2X4 FRAMING
2x4 WALL SHALL
BE CENTERED ON
2X6 WALL BELOW
2
A7
2
A7
GARAGE
KITCHEN KITCHEN KITCHEN KITCHEN
GARAGE GARAGE GARAGE
3
A7
3
A7
05/12/20
Mike Sheeks