HomeMy WebLinkAboutBell Techlogix 2nd Flr Electrical E112-
LEGEND
NEW CONSTRUCTION
� POWEROUTLEf.DUPLEX
�POWEROUiLEi.
QUADRUPLEk
J� JUNCiION BOX
O CEILING MOUNTED
JUNCiION BOX
(81 BOX, BLANK COVER PLAiE
L 80X,OPEN
� PROVIDE JUNCTION BO%
ABOVE CEILING FOR
POWER POLE
CONNECTION. POWER
POLE BY OiHERS.
FLOOR BOX WITH POWER
�p AND DAiA. FLUSH
MOUNiED
FLOOR BOX WITH
�q JUNCilONeO%AND
DATA.FLUSH MOUNiED
DAiA/COMMUNICAiION
✓J OUTLET�PROVIDEBOX
AND PULLSTRING ONLY�
DED DEDICATEDQRCUIi
GFCI GROUNDFAULTCIRGUIT
IMERRUPi OUiLEi
+4T' HEIGHiOFELECiRICAL
OR DAiA DEVICE
EXISTING TO REMAIN
� POWEROUiLELDUPLEX
� POWEROUiLEi.
QUADRUPLEk
� JUNCiION 80X
O CEILING MOUNTED
JUNCiION BOX
Q BOX.BLANKCOVERPLAiE
DO BOX.OPEN
0 POWERANDDAiAPOLE
FLOOR BOX WITH POWER
�I'� AND DATA, FLUSH
MOUNiED
FLOOR BOk WITH
�J I� JUNCiIONBOXAND
DAiA,FLUSH MOUNiED
b DATA/COMMUNICAiION
OUTLEi
GENERAL NOTES
1. iENANi'S FURNIil1RE VENDOR IS RESPONSIBLE FOR WSiALLATION OF
FURNIiURE AND FIELD VERIFICAiION OF ALL CRITICAL DIMENSIONS.
2 ALLOUiLEfSARETOINSTALLEDIB"MIN.AFFTOTHEGEMEROF
iHE DEVICE PER ADA GUIDELWES UNLESS NOTED OTHERWISE ALL
NEw DEVICES AND FACE PLAiES i0 MAiCH EXISiING.
3. REFERiODOORSCHEDULEANDCOORDINAiEWIiH
iENANT/O W NER REGARDING PO W ER LOCATIONS TO
ACCOMMODAiE ELECiRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS CAkDREADEkSAREiYPICALLYINSTALLED9YTHE
iENANT'S SEGURITY CONTRACTOR AND NOT SPECIFlED BY SDI.
4 ELECiRICAL W ORK 6 LIMIiED i0 A DESIGN-BUILD SCOPE AND IS
OUiLINED IN iHESE DRAwINGS. ALL ELECiRICAL WORK IS LIMIiED
i0 ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVIGES
AND LIGHTW G THAT DO NOT EXCEED THE CAPACIiV OF THE
E%ISiING ELECiRICAL SERVICE IN iHE BUILDING. ELEQRICAL
CONiRACiOR b i0 NOTIFY APPLICABLE PARiIES IF ADDIiIONAL
WORK IS REQUIRED SO THAT ADDIiIONAL PLANS CAN BE FlLED AND
MUSi COMPLV W IiH ALL APPIJCABLE CODE$_
5. COORDINAiE POWER AND DAiA FOR NEW wORKSiATIONS wliH
iENANTAND FURNIiURE VENDOR.
PLAN NOTES
E01 COORDINATEE%ACiPOWERANDDAiEREQl11REMENTSWITH
TENANT.
E02 PROVIDE POWER Ai iHIS LOCAiION FOR iENANi'S DISHwASHER
AND/OR GARBAGE DISPOSAL.
E03 NO ELECiRICAL WORK NEEDED IN iH6 LOCATION,
iHIS DRA W ING. AND iHE IDEAS.
DESIGNS AND CONCEPb CONiAwED
HEREIN.AREiHEE%CLUSNE
IMELLEQUAL PROPERiY OFSCHOII
DESIGN. WG. AND ARE NOi i0 BE
USED OR REPRODUCED IN WHOLE OR
IN PARi, W IiHOUi iHE W RIIIEN
CONSENi OF SCHOII DESIGN.
/
/
/
/
/�
/
/
/
/
0
AREA NOT IN CONTRAQ
RELEA5E0 FOR CONSTRIICTI�N
oarE: 05/13/20
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM.�� .
AREA OF WORK
� ��
� � ➢ --- ._. . . .
ELECTRICAL PLAN
0 2' 4' 8' 16'
� � -
/
/
��� -
ENCLAVE ENCLAVE FNC.AVF
LC9 .91�] .211
0
/
�
�
/
/
/
/
�
�
�
Vw
_ I
O �
O
� Q O �
� m
� ? � �O
.p - M �
P QnL
w a M N
o c
va�-3
c 3
N
�
O
O
� J
I.L
��
Z N
N
O��
JQ�t
=FZ
N
V�J
w
W -�
� N �
��U
J
W �
o•
m �
0
0
�
�
�ERENCE
212
�////// /
/
/
ISSUE
DATE DESCRIPTION
03.1P.P0 REVIEWSET
03.13.20 PERMITSET
REVISIONS
MARI DATE DB DESCRIPiION
� li�
=A� AR10700017 ��
p C,ti STATE OF � �
? �ST �h' I ANP �'����
,,��"'� q ni U��"•
�--� ��
PROJECT NUMBER
2018.514
PROJ. MGR DRAWN BY
SDH/EH NP
2ND FLOOR
ELECTRICAL PLAN
� E112