Loading...
HomeMy WebLinkAboutS001.1H. G. McCULLOUGH DESIGNERS, INC- 2146 Glenview Drive, Evansville, IN 47720- Email: designers@hgmccullough.com- Telephone: 812 . 428 . 0174 - www.hgmccullough.comDesigned For:NVL 307 - Kennedy 2x4 STUDS 12" AIRSPACE 12" POURED CONC. WALL * STUD WALLS ALONG THE MASONRY FOUNDATION WALLS * INTERIOR DIMENSIONS TO FACE OF STUD WALLS * EXTERIOR DIMENSIONS TO FACE OF SHEATHING CONCRETE BLOCK WALLS CONSTRUCTION LEGEND FRAME WALLS 1. MATERIALS LEGEND BEARING WALLS CONCRETE WALLS 2. GENERAL NOTES * ZONED HVAC CHILDREN'S PLAY ROOM WALK UP BARMEDIA/FAMILY ROOM UNFINISHED STORAGE UNFINISHED & HVAC UP 17 EQUAL RISERS BEDROOM/FITNESS BATHROOM CLOSETCLOSETSERVING BAR CLOSET W.C. L. FIBERGLASS SHOWER UNIT UNEXCAVATED UNEXCAVATED UNEXCAVATED UNEXCAVATED UNEXCAVATED UP 15 EQUAL RISERS NOTE: ZONED HVAC CMT3046-3 CMT3046-2 CMT3046-23'0"x6'8" 3 '0"x 6 '8 "2'6"x6'8"3'0"x6'8"3'0 "x6'8"3 '0"x 6 '8 "3'6"x6'8" DRYWALL WRAPPED OPENING 3'0"x6'8" PAIR DOORS 2'0"x6'8"PAIR DOORS2'0"x6'8"PAIR DOORSW12x26# STEEL BEAM W10x19# STEEL BEAM W10x19# STEEL BEAM W10x19# STEEL BEAM 312x31 2x14" STL. COL. 312x312x14" STL. COL. 31 2x312x 14" STL. COL. 312x312x14" STL. COL. 2-PLYx16 FLUSH LVL HEADER W/ JST HANGERS 16" FLOOR JST.16" O.C. DIRECTION16" FLOOR JST.16" O.C. DIRECTION16" FLOOR JST.16" O.C. DIRECTION"X" INDICATES 4" DROP FLOOR SYSTEM FOR MASTER SHOWER FLOOR 2 8 1 8 4 8 2 8 3 8 4 8 1 8 4" 14'-81 2" 31 2" 7'-21 4" 3 1 2"5'-2 3 4 " 19'-4 1 2" 7'-11 2"312" 5'-01 4" 312" 2'-0" 4" 13'-1114"312"2'-534"312" 5'-11 2 " 312"36'-0" 4"8'-10"14'-21 4" 312" 6'-634" 10'-634"6'-101 4" 17'-5"31 2"3'-3"31 2"24'-41 2"4" 3'-612"6'-111 4"1'-0" 9'-41 4" 1'-0" 6'-1"5'-11"312" 6'-81 2" 312" 9'-15 8"512" 10'-17 8"512"6'-2" 512" 10'-6"3 12 "5'-7"512 "8'-212"3'-112"4" 16'-7"512" 11'-418"312"10'-258"1'-0"16'-214" 4"6'-4"312 "4'-1"5'-518" 6'-212"912"10'-2"5'-1"512"16" FLOOR JST.16" O.C. DIRECTION16" FLOOR JST.16" O.C. DIRECTION3 82" MINIMUM SLOPEDCONCRETE SLAB2" MINIMUM SLOPED CONCRETE SLAB 9'-334" 14'-1516" 10'-9116"412" 412" 412" 412"SINK SUMP w/ BATTERY BACKUP EJECTOR PIT & PUMP GAS FURNACE AWH AWH TILE FLOOR HOLD THIS AREA AT SLAB HEIGHT FOR DOOR TO SET ON 2'0"x6'8"PAIR DOORS2SCALE: 1/4"=1'-0"LOWER LEVEL FLOOR PLAN Drawings & blueprints are intended solely as a plan layout& basis for materialestimate. H.G. McCullough Designers Inc.assumes no responsibility for structuralor material adequacy of drawings nor for compliance with appropriate building codes.H.G. McCullough Designers Inc. is not liable for, nor does it guarantee or controlcontractor or subcontractor's performance, nor their errors or omission. Customersshould have qualified engineer or architect review construction detailsSHEET NUMBER"C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction of this work, its technical aspects or creative content without the express written consent of H. G. McCullough Designers, Inc. This work is fully protected by copyright under U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc." 05/13/20 Adam Schriner