Loading...
HomeMy WebLinkAboutL100 LIFE SAFETYCODE SUMMARY 1 I SCOPEOFWORK 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PREVIOUS USEOFSPACE OCCUPANCY CLAS9FlCAilON CHANGE OF OCCUPANCY CLASS? TOiAL BUILDING AREA TOiALPROJECTAREA OCCUPANCY CALCULATIONS NUMBER OF EXITS SPRWKLERSYSiEM IYES/NOf TOiAL ABEA OF ACCESSORY USES TOiAL ABEA ON iHE FLOOR ACCESSORY AREA EXCEEDS 10% FIRE W ALLS, AND/OR OCCUPANCY SEPARATIONS �IF REQUIRED� ASHRAE 90J SUMMARV :1111�C1iS�l:iiL9F.Y� :11111nI�RIKHl611:LBIIPIT��Y9i OFFlCE REMODEL OF PREVIOUSLY BUILi-OUi OFFlCE SPACE B USINESS 1 I B�USINESS� NO 19.359 SF/FLOOR X 8 STORIES = 154,8]2 SF 4436 SF SPACEiYPE I AREA I SFPEROCCUPAM I OCCUPLOAD TOiAL OCCUPANiS IN PROJECi ARE4 REOUIRED:I PROVIDED:2 YES - EXISTING i0 REMAIN 0 SF 19,359 SF NO N/A EXEMPT (SEE REFLECTED CEILING PLAN� NO IB LEGEND Ep EXISTING ELECTRICAL PANEL IOCAiION EX EXISTING EXIT- BUILDING STAIR LOCATION elre FIREEXTINGUISHER � EXIT SIGN � EMERGENCY LIGHT — — — TRAVEL DISTANCE 45 LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN iENANi SPACE AS REQUIRED PER NEMA AND IBG EMERGENCY BATfERY PACKS OR IJGHTS CONNEQED i0 AN EMERGENCY POwER SOURCE ARE REQUIRED IF THE SPACE CONiAMS 50 PERSONS OR MORE FIXTURES SHO W N ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOiIFICAiION APPLIANCES IHORNS/SiROBES�, EMERGENCY SPEAKERS, SMOKE DHECTORS RRE PULLS, AND ANY OTHER REQUIRED AURM & DETECTION SYSiEMS AS NECESSARY TO MEEi ALL APPLICABLE CODES (INiERNAiIONAL BUILDING CODE, IMERNATIONAL FlRE CODE NFPA�. IN RECEPiION AREAS. CONFERENCE ROOMS AND OiHER HIGH PROFILE AREAS WIiHIN SUIiE, ALL LOCATIONS OF SUCH DEVICES MUSi BE APPROVED 8Y SDI OR TENANT PRIOR TO WSTALLATION. FAI W RE TO DO SO MAY RESULT IN CONTRACiOR RELOCATING iHESE IiEMS AiTHEIR EXPENSE_ 3. FIRE EXiINGU15HERS: CONiRAQOR i0 ENSURE ALL NEW AND EXISTING FlRE EXTINGUISHERS ARE INSTALLED ACCORDINGTO NFPA 10. COORDINATE WIiH OW NER/LANDLORD ON EXTWGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEEi FROM ANY POINi TO A VISIBLE EXTINGUISHER. 4. FlRE PROiECTION WORK IS i0 BE PROVIDED BY DESIGN/Bl11LD SERVICESUNDERTHEGENERALCONiRACi. PROVIDEACOMPLEiE, WORKINGSYSTEM. SCHOiiDESIGN.ING,ISNOTRESPONSIBLEFOR THE DESIGN, WSTALLAiION.OR RENOVATION OF THE FlRE SPRWKLER SYSiEM. 5. THE FIRE PROTECiION CONiRACTOR SHALL GENERAiE ALL REOUIRED DRA W INGS, AN� SHALL FLE iHOSE DRA W INGS, AND REL4iED DONMENiS, W IiH iHE SiAiE AND LOCAL AUTHORITIES HAVING JURISDICiION OVER THE PROJECi. F'IU � � � � V'w _ I o � 0 � Q O � � m � ? � �O .p - M � P QnL w a M N O c va�-3 c 3 iHIS DRA W ING. AND iHE IDEAS. DESIGNS AND CONCEPb CONiA W ED HEREIN.AREiHEE%CLUSNE IMELLEQUAL PROPERiY OFSCHOII DESIGN. WG. AND ARE NOi i0 BE USED OR REPFODUCED IN WHOLE.OR IN PARi, W IiHOUi iHE W RIIIEN CONSENi OF SCHOII DESIGN. N (� Z � � W � >�oz —o- � � M � y � F W ZJ�� W O" � 2H�� �Z�Z � Z � � � W � � w �Wz� V�oz H � W �' � � � ISSUE DATE DESCRIPTION 01.07.2020 REVIEW SET 04.13.R020 PERMITSET 04.]1.10]0 CONSiRUCTION SEf REVISIONS MAR DATE DB DESCRIPiION PROJECT NUMBER 2019.327 PROJ. MGR DRAWN BY AS CRB 3RD FLOOR LIFE SAFETY RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM.�� . oarE: 05/15/20 � AREA NOi IN CONiRACi ❑ AREAOFWORK GENERAL NOTES LI. REFER i0 ARCHIiEQURAL PLAN FOR WALL iYPE AND CONSiRUCiION DETAILS. L2 EXISTING E%IiSIGNi FlRE PULLS. FRE EXTINGUISHERS. ALARM NOiIFlCAiION APPLIANCES i0 REMAIN. RELOCAiE EXISTING EXIi SIGNS FlRE PULLS, FlRE EXiINGUISHERS AND ALARM NOTIFlCATIONS AS REQUIRED TO MEEi ALL LOCAL AND SiAiE CODES. LIFE SAFETY PLAN 0 4' 8' 16' � �N � � 00