HomeMy WebLinkAboutG102 Code Summary( f,fN�f x��t ) . RETAIL CODE SUMMARY ... . • . Applicable Codes�. 20141ndiana Building Cotle 20141ntliana Fire Cotle 20091ndiana Elecincal Code 20141ntliana Mechanical Cotle 20121ndiana Plumbing Cotle 2010 Intliana Energy Gonservation Gotle 2011 Indiana Elevator Sa(ery Code Scope of ProjecC T�e conslmction of retail areas within ihe 1"level of the previousty designed parking ga2ge_ euiltling Component 20141ntliana Builtling Gotle Occupancy Retail-Undelermined Classification: - Potential Tenanis A-2, A3, B, M Occupancies [303.3, 303.4, 304.1, 309.1] Service Garage -S-0 Occupancy �3112] Parking Garage, Open antl Enclosetl - S-2 Occupancy �311.3� Conshudion TyOe� Type IB (Non-combustible, 2-hour reted) ConsVuclion requiretl basetl upon ns�mc�ion �ype of paMing garage [fable 5W� Allowable Area 54 TabularArea CB,000 sf Occupancy: Allowable per Floor'. 48,000 s! [Ta�le 503� Acwal Area Gmuntl Flooc 2,860 sf Allowable Area S2 TabularArea ]9,000 sf Occupancy: Allowable per Floor'. ]9,000 s! [Table 503� ACWaI Area Gmuntl Flooc 30,689 sf Allowable Area A-2, A3, TM1e refall areas are permi�tetl �o be unlimi�etl in area basetl upon separa�ed mixetl B, M Occupancies: uses. ACWaI Area Gmund Flooc 20,318 s( Allowable HeighC 11 Stories, 160' �Table 503] Retail antl Service Garage- 1 story acWal Parking Garege - 5 stories with rooi top parking aclual BuildingElements-Flre SimcWrel(rame'. 2-hourrated Resis�ive Requiremenis' Bearing Walls 2-0our ra�etl Floorassemblies 2-hourraled Roofassemblies_ �-M1ourratetl �Tablefi0l� • ExteriorWalls-Fire NonbearingexteriorwallsM1avingatleast30feetofflreseparationtllstancepermitled Resistive Requiremenls�. lo be of nonrated, noncombuslible consVuclion, 1-hour mnslmction required for less �han 30 fee� of fre separation tlisGnce. �Table fi02] Maximum Area of unpmmctetl Openings- Flre Separatloa � 5 fee4 none perminetl Exterior Wall Openings�. �5 < 10 feeb 10 % >10<15faeR15% �1$ a 20 feeb 2$ % >zo <ze reas a5 i >25 < 30 teel- ]0 % >3�feet-Unlimi�etl [Table]058� Occupancy Separa[ion'. 1-hourfire barners will be pmvitletl ro separa�e �he A-2. A3. B, M, antl S Occupancies for separaled mixed uses and lo permit changes in occupancies in Ihe fuWre within �he tenan� spaces. [5�8 0� SepaaletlMixetlUses 28fi4+30fi89+ 20318 =045<1 48,000 ]9,000 Unlimi�ed Incidenlal Use The (ollowing rooms are requiretl to be provitled witM1 a nonra[etl se0aretion consisling SeparaHons: of walls lerminating at tM1e tleck, witM1 sel4closing tloors: - Furnace moms with equipment over 4000.000 BW/hour inpul - Was�e wllec�ion moms over 100 square fee� �Table 5�9� EIBL�fILdl IYtl05�0lTBf fOOT6lBQWfBI� l0 b¢ 6BP82�B(I Wllh 1-hOOI COO61NGI100 �If con[aining oil-insula�etl Vansformers over ]SkVA, or tlry-lype Vansformers over 1125kVA; and ihe transformers are less than a Class 1551nsulation rystem rating. �45042, 45021(b), IEC� Shafl Enclosures' Ducts ihat connect no� more Nan iwo stories are not requiretl lo �e enclosed in a shafl when a fire damper is installed at the floor line. �]i] 6.1] Vehical shafls are requiretl lo be enclosetl wilh 2M1our mnstmc�ion where mnnevling 3 or more slories []13 4� Fire antl Smoke Fire tlampers are reQuired at tlmt peneVations of shatts and 1-hourtire �arriers. Dampers: Smoke dampers not required �]1 ].5] Corridors: Egmss wrritlors, if pmvitle4 mus� be a minimum 44 inches in clear antl unobstmcmd width, a minimum of 36 inches is permilled where serving an occupanl load less Ihan 50. �Table 1018 2� Egress corritlors, i� pmvitleQ mus� be 1-M1our ra�etl fire patli�ions antl canno� have tlead-end wrritlors�ha�exceed 20feel �Table 1018.1,1018.4� The service corridor is not used as a means of egress. Doors: Doore musl nol be less Ihan 32 inches in clear widlh. Doors musl swing in �he direc�ion of egress Iravel when serving an occupan� load oi 50 or more. Exit tloors are required to be side-hinged swinging type, exceptfor oHice or storage areas wi�h an occupant load of less [han 10. Manually opera[etl horizontal slitling tloors permi¢etl from rooms with an occupant loatl tha[ does not exceetl 10. �1008.1.1, 1008.1 2] Panic Hartlware: Panic hardware is required fortloors �ha� la�ch in A Occupancies wi�h an occupant oad of 50 or more, not requiretl for 6, M, antl S Occupancies. [1008.1.10] �-.-. . --. . , . Means of Egress: Two means of egress must be pmvitlad fmm any space wFere tM1e occupant load exceetls 49 for A, B, and M Occupancies and 29 for S Ocwpancies or where �he common pa�M1 of havel exceetls ]5 feet �Table 1015.1, Table 1014.3� Travel to an Exi[ Trevel distance to an exRlmm any point must not exceetl 200leetlorA, B, M, and S- 1 Occupancies. [Table 10162] Exite�. A minimum of 2 exits muet be pmvlded per story. �10212] An exit capaciry of 02 in/occupanl musl be providetl tor horizontal Vavel such as tloors, ramps, e�u [Table 1�05.1] Occupan[ Loatl Faclors' Business areas: 100 sq ft/occ. Mercantile'. 30 sq.fl./occ. Unwncenhatetl assembly use� is sq tt bcc. Slorage: 300 sq.(t/occ. [Ta�le 1004.12� Automa[ic Sprinklers'. An automatic sprinkler system per NFPA 13 will be provided in [he retail areas and service garage �o permi� any �enan� space lo po�en�ially be an A-20cwpancy. Slandpipes: Class I Standpipes reQuired �ased upon hig�est floor level loca�ed more Ihan 30 feel above Me lowest level of fire depatlment vehide access. System Is permitled to be a manual-tlry sys[em. Being provitletl in tlesign of parking garage �9053.1] Fire Alarm System'. A fre alarm system is required for A Occupancy lenanl spaces wiN an ocmpanl load of 300 or more, B antl M Occupancy tenant spaces wi�h an occupant load of 500 or more. 19W 2.1. 90]22. 9W 2.]] Smoke �electors'. Smoke detectors musl be installed in supply air systems wilh a design capaciry greateriM1an2000cfm,'mtM1esupplyairtluct �6062,IMG] Illumina[ion of Means of Illumination mus� be provided for required means ofegress as well as [he exit Egress�. discharge that leads to a public way at all times the building space semed by tM1e means of egress is occupied �1006.1� Emergency Lighting�. Emergency lighling is required in all corridors, rooms, antl spaces Ihat require more [M1an one means of egress or exit antl a� ex[erior lantlings in builtlings �ha� require more Nan one exit �1006.3] Exit Signs: Exit signs requiretl to indicate tM1e direction oi egress travel for rooms and areas ihal require more [han one exi� access. �1011.1� Inlerior Finishes: A-2 8 A-3 Occupancies: Class B Mishes are permiltetl Ihroughoul. Class C finishes re permi�tetl in corritlors, mom antl enclosetl spaces. B, M, 8 5 Occupancies: Class C finishes are permiVed Nroughoul �Table 803.9� PEOCOR DESIGN GROUP LLC AmhitecNre / Prqect ManagemeN�. 355 Gi�y CenterDrive Wrmel, Intliana 46032 3177057979 (phone) 3177057980 ((ax) Amhitect 00033126 \ Sr4i[ OF i � � � � � KEY PLAN � HAMILTON WEST SCAI£Ni9 vuurvoem Developec P E D C O R �:� �e� DEVELOPMENT CO. Project: �A ^v /, W � � O �� •� � _ � JM W W W �(� V Z O C � � � N M ��/� �1/ � � c � � � � � � U Construction Documents Setlssue Date Sheellssue Dale Drawn By Checketl By ast � ewsion ate�eu,� 0100% Cons�mc[lon Documen�s 12118/19 Projec� Number Sheet TiHe: Code Summary Sheet Number RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel �!,,:,�r; ,�;va� DATE: 06�� $�ZO �i 1O2