HomeMy WebLinkAboutE001 - 36AA33 3 CS FURNACE SUMPEJECT PREWIRE FOR FAN w/LIGHT ONLY CS GFI GFI TV CS CS TO LIGHT ABOVE BEDROOM #2 W.I.C. UNFINISHED STORAGE/ MECHANICAL MEDIA ROOM BATH 3 WET BAR UNFINISHED STORAGE UNFINISHED STORAGE BEDROOM #3 W.I.C. PREWIRE FOR FAN w/LIGHT ONLY TV GFI GFIGFI GFI W.S.R.I. CS CS DROPPED MECHANICAL BULKHEAD DROPPED MECHANICAL BULKHEADDROPPEDMECHANICALBULKHEAD TANKLESS W.H. LED LED LED GFI GFIGFI GAME AREA LIGHT FAN TV SINGLE POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH CARBON / SMOKE DETECTOR TELEPHONE JACK TV/ DATA EXHAUST FAN DUPLEX OUTLET WEATHER PROOF OUTLET GROUND FAULT OUTLET 220V OUTLET RECESSED EYEBALL LIGHTEYE CEILING FIXTURE WALL MOUNT FIXTURE FLUORESCENT FIXTURE RECESSED FIXTURE TRACK FIXTURET UNDER CABINET FIXTURE EXTERIOR FLOOD LIGHT WIRE FOR PADDLE FAN WIRE FOR PADDLE FAN AND LIGHT KIT CS34 WP GFI 220V FLUSH MOUNT LED FIXTURE CUSTOMER:PROJECT NAME:LOCATION:DRAWING TITLE: DRAWN BY:WedgewoodBuilding Co., LLC317.669.630032 First Street NECarmel, IN 46032www.wedgewoodbc.comCopyright c 2015 Wedgewood Building Co. LLC. 4/23/2020 9:39:58 AM E1Wedgewood Building Co. LLCBellamy -Custom Plan/Elevation320 -Shoshone Drive, CarmelBASEMENT ELECTRICAL ABL1/4" = 1'-0"1 BASEMENT ELECTRICAL PLAN Rev.No. Date DescriptionELECTRICAL PLAN NOTES: 1. REFER TO COVER PAGE FOR SPANISH TRANSLATIONS = REFERIRSE A LA PORTADA DE LAS TRADUCCIONES AL ESPAÑOL. By Andrew Lund at 9:43 am, Apr 23, 2020 05/26/20 Mike Sheeks