Loading...
HomeMy WebLinkAboutL500 - Site Details1 1/2" 2 1 2" Compacted Subgrade Bituminous Binder #8 Tack Coat Bituminuous Surface #11 Compacted Aggregate #53 8"STANDARD ASPHALT PAVEMENT Not to Scale 1 1/2" 2 1/2" INDOT 1C or 1B Chemically Treated Subgrade HMA Intermediate 19mm (Bituminous Binder #8) Tack Coat Bituminous Surface #11 Compacted Aggregate #53 6" HEAVY DUTY ASPHALT PAVEMENT Not to Scale HMA Base 25mm 14" 3" STANDARD CONCRETE PAVEMENT Not to scale 4,000 psi Fiber Reinforced Concrete, See Specifications Varies (See Plan Sheets) NOTES: 1. Control joints, expansion joints and edges of sidewalks indicated as hand-tooled shall be dressed after each finishing operation. 2. Provide expansion joints at intersection with another sidewalk, beween walks and building slabs, and at other points as indicated on the drawings. 3. Refer to plan drawings for locations of control and expansion joints. Compacted Subgrade 4" Compacted Crushed Stone Finish Grade 4"CONCRETE JOINTING Not to Scale Straight, true sawn joint #5 smooth bar, 12" long, 18" o.c., centered in slab, grease one end SAWN CONTROL JOINT EXPANSION JOINT 3/8" deep, typ Heel-grade sealant, Refer to Specs. 1/8" r. TOOLED CONTROL JOINT As indicated on plan drawings. Place expansion joints where concrete pours meet and anywhere concrete patching is required. As indicated on plan drawings. Continue to wall face in all applicable conditions. Brush out marks from trowel on either side of joint, leaving only the joint scored smooth. NOTE: Expansion joint material shall be "Zip-Strip" expansion material with removable cap by Greenstreak or approved equal. 3/8" tooled joint 1/4" 3/8" 1" 1/3 slab thickness 1/4" max.NOTE: Turn down concrete and dowel at all threshold conditions, where new concrete abuts existing slabs, and at proposed stairs and walls. 4,000 p.s.i. concrete w/limestone aggregate & 5% air entrapment, reinforced with synthetic fibers. Refer to Specifications. Transverse medium broom finish. 1 2" dia. smooth dowel, 12" long, 18" o.c., centered in slab, sleeve one end. 1/2" wide sealed expansion joint Adjacent building slab or face of wall Drill 6" into existing slab; grout solid.4"3" 4" 1'-0" DOWELS IN CONCRETE @ THRESHOLD Scale: 1"=1'-0" 6"6"1'-0" 45°6" 6"4" 1" Rad. Control Joint 1 4"/Ft. Slope Top of Pavement Concrete with Fiber Additive Compacted Aggregate #534" Compacted Subgrade NOTES: 1. Curb shall have 12" expansion joints at 40'-0" max, control joints at 8'-0" max. unless otherwise noted. 2. Control joints shall be cut 14" depth of total thickness of slab. 3. Fiber additive: Virgin nylon fibers, 3 4" length, Nycon by Nycon Inc., or Forta Nylon by Forta Corporation, added at the batch plant at 1 lb. per cu. yd. of concrete. INTEGRAL CONCRETE CURB & WALK Scale: 1"=1'-0" 1 3 4 5 9 8 7 10 1 1/2" 4" Compacted Subgrade Bituminous Binder #8 Tack Coat Bituminuous Surface #11 Compacted Aggregate #53 8" MEDIUM DUTY ASPHALT PAVEMENT Not to Scale2 MEDIUM DUTY CONCRETE PAVEMENT Not to scale 4,000 psi Fiber Reinforced Concrete, See Specifications Varies (See Plan Sheets) NOTES: 1. Control joints, expansion joints and edges of sidewalks indicated as hand-tooled shall be dressed after each finishing operation. 2. Provide expansion joints at intersection with another sidewalk, beween walks and building slabs, and at other points as indicated on the drawings. 3. Refer to plan drawings for locations of control and expansion joints. Compacted Subgrade 6" Compacted Crushed Stone Finish Grade 6"Varies (See Layout Plan) Compacted Subgrade Compacted #53 Aggregate 4,000 psi Fiber Reinforced CIP Concrete 8"HEAVY DUTY CONCRETE PAVEMENT Not to Scale8" 6 6"1'-0"45°6" 6"4"Control Joint 1 4"/Ft. Slope Top of Asphalt, flush condition. Refer to Standard Asphalt Detail 1/L500 and Specifications Concrete with Fiber Additive Compacted Aggregate #534" Compacted Subgrade NOTES: 1. Curb shall have 12" expansion joints at 40'-0" max, control joints at 8'-0" max. unless otherwise noted. 2. Control joints shall be cut 14" depth of total thickness of slab. 3. Fiber additive: Virgin nylon fibers, 3 4" length, Nycon by Nycon Inc., or Forta Nylon by Forta Corporation, added at the batch plant at 1 lb. per cu. yd. of concrete. FLUSH TURNDOWN CURB Scale: 1"=1'-0" 3 1.Addendum #03 12-20-2019 4'-0" 6"6" 3'-6"EXISTING PAVEMENT OR GRADE 1/4" CROWNED WASH, TYP.6" 8" GALVANIZED SCHEDULE 40 STEEL PIPE (1/4" WALL THICKNESS). FILL WITH CONCRETE. TNEMEC PRIMER & PAINT OR EQUAL. COLOR: SAFETY YELLOW. 4,000 PSI C.I.P. CONCRETE, TYP. STEEL PIPE BOLLARD - 8" Scale: 3/4" = 1'-0" 1/2" EXPANSION JOINT DOME THE CONCRETE FILL AT TOP OF STEEL PIPE 11 5 2. TAC Comments 01-03-2020 Note: All Heavy Duty Asphalt within dedicated ROW to be completed in one paving season.CONFORMEDSETCONCRETE POST CURB / FLUSH CURB TRANSITION Scale: Not to Scale 6"4'-0" (min.) Transition Flush Curb Width varies, refer to plan. 4'-0" (min.) Transition Post Curb Post Curb 12 6 2. ASI #001 02-14-2020 6 05/27/20