Loading...
HomeMy WebLinkAboutC501 - OVERALL UTILITY PLANWWWWOHU OHUOHUOHU OHUOHU OHU OHUOHU OHU OHU OHUOHU OHU OHU OHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHUG OHU OHU OHUOHU OHUOHUOHUOHU OHU OHUOHU OHUOHU OHU OHU OHUOHUOHUOHUOHU OHU OHU OHU OHUOHU E E E E EEE E EG G WW WWW WWW4TH A V E N U E 6''SSD6''S SD 6''SSD6''SSD 6''SSD6''SSD6''SSD 6 ''SSD6''SSD 6''SSD6''SSD6''SSD 6''SSD 6 ''SSD 6''SSD 6''SSD6''SSD 6''SSD6''SSD6''SSD6''SSD 6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD6''SSD6''SSD6''SSD 6''SSD 6''SSD6''SSD6''SSD6''SSD 6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD6'' SSD6''SSD6''SSD6''SSD 6''SSD 6''SSD6''SSD6''SSD 6''SSD6''SSD6''SSD 6''SSD6''SSD6''SSD6''SSDFDC TSTOPSTOP DO NOTENTERSTO P 12 345678 91012 345 678 910STO P STOPBUSONLYDRIVE TO BE CONSTRUCTED BY OTHERSUNDERGROUND DETENTION WALK TO BE CONSTRUCTED BY OTHERSPROPOSED BMP & ACCESS EASEMENT P R O P O S E D B M P & A C C E S S E A S E M E N T C . O . TY PE I I C . O . TYP E I I C. O . T Y P E II DETENTION: 7' CMP FL / INV 843.8 (FLAT: 0% SLOPE) (TOP OF PIPE 850.8) HW 10-YR= 847.32 HW 100-YR= 850.59 4"6" DOMFIREP RD RDRDRD RDRDRDRDRDRDRDRDRD RDRDPROPOSED ACCE S S EA S E MENT NO PARKINGNO PARKI NGNO PARKING C . O . TY PE I C.O.TYPE I C. O . T Y PE I C.O.TYPE I C.O.TYPE IH.Pt. PROPOSED BMP & ACCESS EASEMENT C.O . C.O .C.O.C. O . C.O.C. O .C. O .C.O . C.O .C. O .C. O . C. O .C.O . 15' ELEC ESMT SUBSURFACE DRAINS (SEE LANDSCAPE PLAN) 199' OF 8" PVC SDR 26 @1.97% 156' OF 8" PVC SDR 26 @0.50% 68' OF 8" PVC SDR 26 @0.50% 261' OF 8" PVC SDR 26 @0.50% B RIM=853.93 A RIM=853.13 C RIM=853.22 D RIM=854.55 E RIM=853.45 F RIM=853.68 731 RIM=855.90 730 RIM=855.10 726 RIM=855.10 788 RIM=855.10 712 RIM=856.00 758 RIM=855.00 772 RIM=854.00 722 RIM=854.80 725 RIM=854.75 752 RIM=854.70 742 RIM=854.50 735 RIM=854.40 759 RIM=854.50 748 RIM=854.20 734 RIM=854.20 729 RIM=854.30 719 RIM=854.20 779 RIM=854.10 721 RIM=854.10 727 RIM=854.00 736 RIM=854.00 728 RIM=854.00 723 RIM=853.50 751 RIM=853.20 745 RIM=852.25 753 RIM=853.10 747 RIM=851.75 717 RIM=853.00 724 RIM=853.00 716 RIM=853.00 720 RIM=852.90 718 RIM=852.90 750 RIM=852.70 776 RIM=852.55 749 RIM=852.50 786 RIM=852.50 778 RIM=852.40 760 RIM=852.25 746 RIM=852.20 744 RIM=852.35 777 RIM=851.90 761 RIM=851.80 743 RIM=851.50 715 RIM=851.50 714 RIM=851.50 787 RIM=851.50 781 RIM=851.00 783 RIM=851.50 756 RIM=851.30 757 RIM=851.30 713 RIM=851.60785 RIM=851.00 784 RIM=851.00 775 RIM=851.00 782 RIM=851.00 780 RIM=851.00 773 RIM=851.00 64' OF 12" RCP @0.31% 112' OF 12" RCP @0.31% 30' OF 12" RCP @0.33% 23' OF 15" RCP @0.30%61' OF 18" RCP@0.25%189' OF 24" RCP@0.25%95' OF 24" RCP@0.25%10 6' OF 24 " RC P @0.49%165' OF 30" RCP @0.30 % 8' OF 30" HDPE @0.37% 65' OF 12" RCP @0.28% 66' OF 12" RCP @0.56% 24' OF 15" RCP @0.85% 67' OF 18 " RCP @1.05% 10' OF 12" RCP @1.52% 63' OF 12" HDPE @2.70% 60' OF 12" RCP @0.84% 36' OF 15" RCP @0.63%79' OF 18" RCP @0.47%144' OF 24" RCP@0.45%101' OF 30" HDPE@0.32%11' OF 30" HDPE @0.38% 1 2 8 ' O F 1 2 " HDP E@1 . 9 9% 8 0 ' OF 1 2 " R CP@0 . 5 0% 27' OF 12" RCP @1.65% 48' OF 12" RCP @0.41%79' OF 12" RCP @0.58%78' OF 24" RCP @0.32%106' OF 24" RCP @0.41%161' OF 12" RCP @0.69% 9 7 ' O F 1 2 " R CP@1.9 5 % 73' OF 12" RCP @0.55% 75' O F 1 2 " R C P @ 0 . 53 %106' OF 18" RCP @0.38%105' OF 24" RCP @0.29%116' OF 24" RCP@0.30%52' OF 24" RCP @0.39%142' OF 24" RCP@0.46%60' OF 24" RCP@0.50%205' OF 24" RCP@0.54%135' OF 30" HDPE@0.37%12' OF 30" HDPE @0.33% 74' OF 12" HDPE @0.81% 54' OF 12" HDPE @0.56% 9 8 ' O F 1 2 " R CP@0 . 6 1 %53' OF 12" HDPE @1.13% 67' OF 12" HDPE @1.79% 52' OF 12" RCP @0.97% 5 2 ' O F 1 2 " R CP@0 . 5 7% 66' OF 1 2 " RCP @1 .62% 64' OF 12" RCP @1.95% 9' OF 12" RCP @1.71% 32' OF 30" HDPE @0.31% 71' OF 15" RCP @0.71%259' OF 24" RCP@0.36%36' OF 12" RCP @0.41% 47' OF 12" RCP @1.92% 15' OF 30" RCP @0.40% 732 RIM=854.60 11' OF 15" RCP @0.28% 733 RIM=854.20 770 RIM=854.20 15' OF 30" RCP @0.40% 11' OF 15" RCP @0.28% 771 RIM=854.10 710 RIM=856.20 15' OF 30" RCP @0.40% 11' OF 15" RCP @0.28% 711 RIM=856.10 427' OF 8" PVC S D R 26@0.50%791 RIM=854.54 792 RIM=854.50 8 " HDPE @ 0 . 8% 8 " HDP E @ 0 . 8% 8 " HDPE @ 0 . 6%10" HDPE@ 1.0% MIN8" HDP E @ 1.0 % MI N 4" HPDE @ 1.0% MIN 8 " HDPE @ 0 . 8% 8 " HDPE @ 0 . 8 %8 " HDPE @ 1 . 0% M IN 8 " HDPE @ 1 . 0% M I N8 " HDPE @ 0 . 8% 8 " HDPE @ 0 . 8% 8 " HDPE @ 0 . 8% 8 " HDP E @ 0 . 8%8" HDPE @ 0.8%8" HD P E @ 1.0 % M I N 8 " HDPE @ 1 . 0% M IN TERMINATE MANHOLE (SEE SHEET C606) 26' OF 12" RCP @0.39% 795 RIM=852.35 26' OF 12" RCP @0.38% 796 RIM=852.20 24' OF 12" RCP @0.42% 797 RIM=852.25 PROPOSED SAN MH BY CARMEL UTILITES. RIM=854.70 RELOCATE / REPLACE EX 6" WATER MAIN 1.5' (18") LOWER ROTATE STRUCTURE & ADJUST CASTING SO THAT IT WILL NOT BE IN CURB LINE 1. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING PLANS FOR CONTINUATION OF UTILITIES WITHIN 5 FEET OF STRUCTURES. 2. PRESSURE UTILITY MAINS AND SERVICE LINES MAY NEED TO BE INSTALLED AT A DEPTH GREATER THAN THAT SPECIFIED OR SHOWN ON THE DRAWINGS TO CLEAR EXISTING AND PROPOSED CROSSING UTILITIES. IN SUCH CASES, THE CONTRACTOR SHALL INSTALL VERTICAL BENDS AS REQUIRED TO ACHIEVE APPROPRIATE CLEARANCE BETWEEN THE CROSSING UTILITIES. 3. A MINIMUM HORIZONTAL SEPARATION OF 10 FEET BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT ALL TIMES. A MINIMUM VERTICAL SEPARATION OF 18 INCHES BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT CROSSINGS. IN THE EVENT THAT MINIMUM SEPARATION REQUIREMENTS CANNOT BE MET, THE CONTRACTOR SHALL UTILIZE PRESSURE-TYPE WATER PIPE FOR THE SEWER PER CITY OF CARMEL STANDARDS. 4. WATER MAINS SHALL BE INSTALLED WITH A MINIMUM OF 54 INCHES OF COVER AS MEASURED FROM THE TOP OF THE PIPE TO THE FINAL FINISH GRADE ABOVE THE PIPE. 5. THRUST BLOCKS OR JOINT RESTRAINTS SHALL BE INSTALLED ON ALL WATER LINES AT ALL BENDS, TEES AND HYDRANTS PER THE DETAILS. 6. WHERE WATER FITTINGS ARE REQUIRED, DUCTILE IRON (DI) FITTINGS SHALL BE USED. FITTING JOINTS SHALL BE OF STANDARD MJ TYPE (ANSI/AWWA C111/A21.11) OR PJ TYPE (ANSI/AWWA C111/A21.11). 7. DI FITTINGS SHALL CONFORM TO ANSI/AWWA C110/A21.10, 350 PSI AND SHALL BE CEMENT MORTAR LINED PER ANSI/AWWA C104/A21.4 AND SHALL BE OUTSIDE COATED WITH A BITUMINOUS COATING. 8. PIPE LENGTHS SHOWN ARE MEASURED FROM CENTER TO CENTER OF STRUCTURES ROUNDED TO THE NEAREST FOOT. 9. PIPE LENGTHS SHOWN FOR STORM SEWERS ARE MEASURED TO THE DOWNSTREAM END OF END SECTIONS. 10. WHERE GRADE MODIFICATIONS (CUT OR FILL) ARE SHOWN ADJACENT TO EXISTING VALVE BOX COVERS AND MANHOLE CASTINGS, THE VALVE BOX COVERS AND MANHOLE CASTINGS SHALL BE ADJUSTED FLUSH WITH THE PROPOSED GRADE. 11. ADJUSTMENTS OF EXISTING MANHOLE CASTINGS TO GRADE TO A MAXIMUM OF 12 INCHES SHALL BE MADE USING PRECAST CONCRETE ADJUSTING RINGS PROVIDED THE TOTAL HEIGHT OF EXISTING AND NEW ADJUSTING RINGS DOES NOT EXCEED 12 INCHES. 12. ADJUSTMENTS OF CASTINGS WHERE THE TOTAL HEIGHT OF ADJUSTING RINGS WOULD EXCEED 12 INCHES SHALL BE MADE BY REPLACING THE CONE AND/OR BARREL SECTION OF THE STRUCTURE. 13. PAVEMENTS, WALKS, CURBS AND OTHER SURFACE IMPROVEMENTS REQUIRING REMOVAL FOR INSTALLATION OF UNDERGROUND UTILITIES SHALL BE RESTORED TO THEIR PRESENT CONDITION UNLESS OTHERWISE SHOWN. 14. ALL INLET CASTINGS LOCATED WITHIN ASPHALT PAVEMENT AREAS SHALL INCLUDE A CONCRETE PAVED COLLAR EXTENDING A MINIMUM OF 24 INCHES IN ALL DIRECTIONS FROM THE EDGE OF THE CASTING PER THE DETAILS. 15. THE CONTRACTOR SHALL MAINTAIN ALL FLOWS AND UTILITY CONNECTIONS TO EXISTING BUILDINGS, ETC. WITHOUT INTERRUPTION UNLESS/UNTIL AUTHORIZED TO DISCONNECT BY THE OWNER, UTILITY COMPANIES, AND GOVERNING AUTHORITIES. THE CONTRACTOR SHALL INSTALL AS NECESSARY, TEMPORARY SITE LIGHTING, GAS, SANITARY, WATER, STORM, ELECTRIC, TELEPHONE, AND CABLE SERVICES TO SERVICE BUILDING(S) TO REMAIN OPEN. 16. CONTRACTOR TO PROVIDE SLEEVES UNDER FOOTINGS OR THROUGH FOUNDATIONS FOR UTILITY CONNECTIONS. 17. CONTRACTOR SHALL PROVIDE ALL BENDS, FITTINGS, ADAPTERS, ETC. AS REQUIRED FOR PIPE CONNECTIONS TO BUILDING/CANOPY STUB OUTS. INCLUDING ROOF/FOOTING DRAIN CONNECTIONS TO ROOF LEADERS AND TO STORM DRAINAGE SYSTEM. 18. CONTRACTOR TO PROVIDE AND INSTALL CONDUIT FOR SITE LIGHTING PER SITE LIGHTING PLAN (BY OTHERS). 19. CONTRACTOR TO PROVIDE AND INSTALL CONDUIT FOR IRRIGATION PER IRRIGATION PLAN (BY OTHERS). 20. CONTRACTOR WILL BE RESPONSIBLE TO REPAIR, REPLACE, AND/OR RECONNECT ANY EXISTING DRAINAGE TILES NOT SHOWN ON THE PLANS, WHICH CROSS THROUGH EXCAVATED TRENCHES. ANY DRAINAGE TILE ENCOUNTERED IS TO BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND A MEASUREMENT TAKEN FROM THE NEAREST MANHOLE OR INLET STRUCTURE TO THE CENTERLINE OF THE TILE. 21. CONTRACTOR SHALL COORDINATE DEMO, RETIREMENT OF EXISTING LINE, NEW SERVICE LINE & METER. CONTACT 1-800-990-1930 AND / OR NEW SERVICE @ VECTREN.COM 22. ALL INLETS WITHIN PAVED AREAS SHALL INCLUDE AT LEAST TWO 20-FOOT SUBSURFACE DRAINS SET 1.5 FEET BELOW THE TOP OF CASTING. UTILITY NOTES W - WATER / FIRE PROTECTION S - SANITARY SEWER 6" PVC SANITARY LATERAL @ 1.04% MIN. SLOPE. CLEANOUTS ARE REQUIRED EVERY 100-FEET. GREASE INTERCEPTOR MODEL # SCHIER GB-1000 PER MANUFACTURER SPECIFICATIONS 6" DIP WATER MAIN FIRE HYDRANT W/ 6" MJ GATE VALVE 6" DIP WATER MAIN TO FIRE DEPARTMENT CONNECTION (FDC) 4" WATER MAIN DOMESTIC SERVICE CONNECTION (COORDINATE FINAL SIZING W/ MEP PLANS) POST INDICATOR VALVE FIRE DEPARTMENT CONNECTION PER CARMEL FIRE STANDARDS CONNECT TO EXISTING 6" WATER MAIN W/ 6" X 6" X 6" MJ TEE W/ THRUST BLOCK 6" DIP FIRE SERVICE LINE 4" MJ GATE VALVE 6" X 6" X 6" MJ TEE W/ THRUST BLOCK 6" X 6" X 4" MJ TEE W/ THRUST BLOCK 6" MJ 45° BEND W/ THRUST BLOCK 4" MJ 45° BEND W/ THRUST BLOCK 6" MJ GATE VALVE W1 W2 W3 S1 D - DRAINAGE / STORM SEWER 6''SSD 6''SSD XCELERATOR XC-6 (SEE DETAIL SHEET C603) XCELERATOR XC-7 (SEE DETAIL SHEET C603) PROPOSED UNDERGROUND DETENTION BASIN. CONTECH 7' DIA. POLYMER COATED PERFORATED CMP (SEE DETAILS SHEET C607). RESTRICTOR AND OVERFLOW STRUCTURE REMOVE AND REPLACE EXISTING STORM STRUCTURE (SEE DETAIL, SHEET C601). CONCRETE COLLAR (NOT TO SCALE, SEE DETAIL, SHEET C603) TRENCH DRAIN (SEE DETAIL SHEET C602) CONNECT UNDERGROUND DETENTION SYSTEM TO EXISTING STORM SYSTEM (SEE DETAIL, C607) 6-INCH PERFORATED HDPE SUBSURFACE DRAIN UTILITY KEY NOTE LEGEND W4 W5 W6 W7 W8 D1 D2 D3 D4 D1A D5 D6 S2 W9 W10 W11 W12 W13 W14 D7 T - TELECOM FIBER OPTIC & CABLE LINES (BY OWNER)T1 G - GAS GAS CONNECTION. COORDINATE WITH UTILITY OWNER.G1 E - ELECTRIC ELECTRIC SERVICE LINE. CONTRACTOR TO PROVIDE 4-INCH PVC SCHEDULE 40 CONDUIT TO TRANSFORMER TRANSFORMER TO BE INSTALLED BY THE UTILITY PROVIDER TRANSFORMER PAD TO BE PRE-CAST CONCRETE IN ACCORDANCE WITH UTILITY PROVIDER SPECIFICATIONS. E1 E2 STORM SEWER PIPE STORM SEWER CLEANOUTC.O. SANITARY LATERAL SANITARY CLEANOUTC.O. PROPOSED LINETYPES LEGEND GAS LINE ROOF DRAIN WATER LINE SWALE UNDERGROUND CABLE SUBSURFACE DRAINS (STRUCTURES) E3 TREE PROTECTION FENCE RD Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 18094 Rev. #Revision Description Issue Date CONFORMEDSETSCALE: 1" = 60' C501 OVERALL UTILITY PLAN 1 TAC COMMENTS 12/20/2019 2 TAC COMMENTS 1/3/2020 3 ASI 001 02/14/2020 4 ASI 002 03/06/2020 5 ASI 006 03/30/2020 6 ASI 007 03/30/2020 7 ASI 009 04/16/2020 8 ASI 010 04/27/2020 8 8 8 05/27/20