Loading...
HomeMy WebLinkAboutC507 - PLAN & PROFILE (STORM)OHU OHU OHU OHU OHUOHU OHU OHU OHU OHU OHU OHUFDC T TP TP T P TPTPTP TP TP TP TP TP C . O . T Y P E II C . O . T Y P E II C .O. T Y P E II 6''SSD 6''SSD6''SSD6 ''SSD 6 ''SSD6''SSD6''SSD 6''SSD6''SSD6''SSD 6''SSD6''SSD6''SSD 6''SSD6''SSD6''S SD 6''S S D6''S S D 4"6"DOMFIRE PRDRDRDRDRD RD RDRD RD RD RD RDNO PARKI NG6''SSD 6''SSD 6''S758 RIM=855.00 752 RIM=854.70 759 RIM=854.50 751 RIM=853.20 748 RIM=854.20 753 RIM=853.10 750 RIM=852.70 749 RIM=852.50 760 RIM=852.25 761 RIM=851.80 64' OF 12" RCP@0.31%1 1 2 ' O F 1 2 " R C P@0. 3 1%30' OF 12" RCP@0.33% 23' OF 15" RCP@0.30%61' OF 18" RCP@0.25%189' OF 24" RCP @0.25%65' OF 12" RCP@0.28% 68' OF 12" RCP@0.55 % 24' OF 15" RCP @0.85% 67' OF 18" RCP @1.05% 26 1 ' OF 8" PV C @ 0 .50 % 68' OF 8" PVC @0.50% 156' OF 8" PVC @0.50%STR. #713 INLET AM; R-3405TC: 851.60INV. OUT 847.00 (15" RCP (E)) 135' 0.37% 30" HDPE STR. #712 DIVERSION MANHOLE, 7' DIA., SEE DETAIL C603; R-1772TC: 856.00INV. IN 844.10 (30" HDPE (S))INV. OUT 844.00 (30" RCP (N))STR. #761 INLET AM; R-3405TC: 851.80INV. OUT 848.03 (12" RCP (SW)) 65' 0.28% 12" RCP STR. #750 MANHOLE, 4' DIA.; R-1772TC: 852.70INV. IN 848.55 (12" RCP (S))INV. IN 847.85 (12" RCP (NE))INV. OUT 847.75 (15" RCP (N))STR. #753 INLET M; R-3010TC: 853.10INV. OUT 849.40 (12" RCP (N)) 64' 0.31% 12" RCP STR. #752 MANHOLE, 4' DIA.; R-1772TC: 854.70INV. IN 849.20 (12" RCP (S))INV. OUT 849.10 (12" RCP (NW)) 112' 0.31% 12" RCP STR. #751 MANHOLE, 4' DIA.; R-1772TC: 853.20INV. IN 848.75 (12" RCP (SE))INV. OUT 848.65 (12" RCP (N)) 30' 0.33% 12" RCP STR. #750 MANHOLE, 4' DIA.; R-1772TC: 852.70INV. IN 848.55 (12" RCP (S))INV. IN 847.85 (12" RCP (NE))INV. OUT 847.75 (15" RCP (N)) 23' 0.30% 15" RCP STR. #749 MH 4' DIA.; R-3010TC: 852.50INV. IN 847.68 (15" RCP (S))INV. OUT 847.58 (18" RCP (N)) 61' 0.25% 18" RCP STRUCTURE 713, 731,712,710 STRUCTURE 761,750 STRUCTURE 753-748STR. #731 MH 5' DIA.;R-1772TC: 855.90INV. IN 844.70 (24" RCP (S))INV. IN 846.50 (15" RCP (W))INV. OUT 844.60 (30" HDPE (N)) 71' 0.71% 15" RCP 12' 0.33% 30" HDPE 10 - YEAR HGL 10 - YEAR HGL 10 - YEAR HGL STR. #748 MANHOLE, 5' DIA.; R-1772TC: 854.20INV. IN 849.50 (18" RCP (NE))INV. IN 847.43 (18" RCP (S))INV. IN 848.03 (12" RCP (W))INV. OUT 847.33 (24" RCP (N))FG EG FG EG FG EGSTR. #710 MH 7' DIA.;R-3405TC: 856.20INV. IN 843.94 (30" RCP (S))INV. IN 843.94 (15" RCP (SW))INV. OUT 843.84 (30" HDPE (N)) 15' 0.40% 30" RCP (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE) G OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUOHUE E E E EETP TPTPDETENTION: 7' CMP FL / INV 843.8 (FLAT: 0% SLOPE) (TOP OF PIPE 850.8) HW100= 850.7 DETENTION: 7'CMP FL / INV 843.8 (FLAT: 0% SLOPE) (TOP OF PIPE 850.8) HW 10-YR= 847.32 HW 100-YR= 850.59 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD6''SSD 6''SSD 6''SSD 6''SSD 6''SSD6''SSD 6''SSD731 RIM=855.90 712 RIM=856.00 772 RIM=854.00 713 RIM=851.60 773 RIM=851.00101' OF 30" HDPE@0.32%11' OF 30" HDPE @0.38% RCP 135' OF 30" HDPE@0.37%12' OF 30" HDPE @0.33% 770 RIM=854.20 15' OF 30" RCP @0.40%771 RIM=854.10 11' OF 15" RCP @0.28% 710 RIM=856.20 711 RIM=856.10 11' OF 15" RCP @0.28% 15' OF 30" RCP @0.40% 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 18094 Rev. #Revision Description Issue Date CONFORMEDSETSTORM SEWER PLAN SCALE: HORZ.: 1"=30' VERT.: 1"=3' GENERAL NOTES LEGEND Existing Grade New Grade Granular Backfill SCALE: 1" = 30' C507 PLAN & PROFILE (STORM) 1 TAC COMMENTS 12/20/2019 The storm sewer system shall be constructed per design specified and as approved by the City of Carmel on the final approved construction plans. Deviations from the approved design shall only be permitted due to special circumstances or difficulty during construction and will require prior field approval from a designated representative of the City of Carmel in addition to supplemental approval by the design engineer. An explanation of any such deviation shall be included as a requirement on as-built/record drawings submitted for release of performance guarantees. Approved design slopes identified as generating velocities of 2.5 fps or less or 10 fps or greater (at full flow capacity) shall require as-built certification at the time of construction, prior to backfilling the pipe. The contractor is instructed to as-built each section of storm pipe as it is being installed to ensure compliance with the design plans and as approved by the City of Carmel. AS-BUILT NOTES 2 TAC COMMENTS 1/3/2020 GRANULAR BACKFILL NOTES ·For RCP storm pipe granular backfill, refer to detail 3, sheet C601. ·For HDPE storm pipe granular backfill, refer to detail 4, sheet C601. · For PVC sanitary sewer, see Carmel Utilities Trench Detail & Trench Schedule on sheet C606. 3 ASI 001 2/14/2020 3 3 3 3 05/27/20