HomeMy WebLinkAboutC512 - PLAN & PROFILE (STORM)STR. #785 INLET M; R-3010TC: 851.00INV. OUT 847.00 (12" RCP (E)) 48' 0.41% 12" RCP STR. #784 MH 4' DIA.; R-3010TC: 851.00INV. IN 846.80 (12" RCP (W))INV. OUT 846.70 (12" RCP (E)) 79' 0.58% 12" RCP STR. #781 MH 5' DIA.; R-3010TC: 851.00INV. IN 845.40 (24" RCP (S))INV. IN 846.24 (12" RCP (W))INV. IN 845.40 (12" RCP (SW))INV. OUT 845.30 (24" RCP (NE))STRUCTURE 785-784,781 STRUCTURE 787,782-780,773 FG FG EG FG EG 10 - YEAR HGL 10 - YEAR HGLSTR. #787 INLET M; R-3010TC: 851.50INV. OUT 847.00 (12" RCP (NW))STR. #782 MH 4' DIA.; R-3010TC: 851.00INV. IN 846.60 (12" RCP (SE))INV. OUT 846.50 (12" RCP (NE))STR. #781 MH 5' DIA.; R-3010TC: 851.00INV. IN 845.40 (24" RCP (S))INV. IN 846.24 (12" RCP (W))INV. IN 845.40 (12" RCP (SW))INV. OUT 845.30 (24" RCP (NE))STR. #780 MH 4' DIA; R-3405TC: 851.00INV. IN 845.05 (24" RCP (SW))INV. IN 845.60 (12" RCP (NW))INV. OUT 844.95 (24" RCP (E))STR. #773 MH 5' DIA.;R-3405TC: 851.00INV. IN 844.52 (24" RCP (W))INV. OUT 844.42 (30" HDPE (N)) 80' 0.50% 12" RCP 161' 0.69% 12" RCP 78' 0.32% 24" RCP 106' 0.41% 24" RCP (PRIVATE) (PRIVATE)(PRIVATE) (PRIVATE) (PRIVATE) (PRIVATE)DO NOTENTERSTO P 12 345678 91012 345 678 910Xref .\Xref\FloorPlan-SITEPLANCE-ELECTRICAL 11-18-19.dwg6''SSD 6''SSD6''SSD6''SSD 6''SSD 6''SSDRDNO PARKING6''SSD 6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD6''SS D 6''SSD 6' 'SSD6' 'SSD6' ' S SD 6 '' S SD6''SSD 6''SSD776 RIM=852.55 786 RIM=852.50 787 RIM=851.50 781 RIM=851.00 757 RIM=851.30 784 RIM=851.00 785 RIM=851.00 775 RIM=851.00 782 RIM=851.00 780 RIM=851.00 773 RIM=851.00 RCP 79' OF 18" RCP @0.47%144' OF 24" RCP@0.45%8 0 ' OF 1 2 " RC P@0 . 5 0% 2 7' O F 1 2" R C P@1. 6 5 % 48' OF 12" RCP @0.41% 79' O F 12 " RCP @0 .58 %78' OF 24" RCP@0.32%106' OF 24" RCP @0.41%161' OF 12" RCP @0.69 % P I 0 + 7 9 . 5 3 PI2+40.10PI3+18.41EP 4+24.10 TPTPTPTPTPTP TPTP TPSTOP6''S S D 6 ''SS D 6' 'SSD6''SSD 6''SSD6''SSDFUTURE LIBRARY DRIVE6' ' SSD 6 '' S S6''SSD 6''SSD772 RIM=854.00 781 RIM=851.00 RIM=851.50 783 RIM=851.50 784 RIM=851.00 780 RIM=851.00 773 RIM=851.00165' OF 30" RCP @0.30 %105' OF 30" HDPE@0.30%11' OF 30" HDPE @0.38% CP 7 9' O F 12" RCP @0.58%78' OF 24" RCP@0.32%106' OF 24" RCP @0.41% 9 7' O F 1 2 " R C P@1. 9 5 % @0.53% 770 RIM=854.20 11' OF 30" RCP @0.53%771 RIM=854.10 8' OF 15" RCP @0.38%PI2+40.10PI3+18.41EP 4+24.10 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. C512 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANAFORCARMEL CLAY SCHOOLSNEW ELEMENTARY SCHOOLSDrawing Title: 11-19-19 SO MK 18094 Rev. #Revision Description Issue Date STORM SEWER PLAN SCALE: HORZ.: 1"=30' VERT.: 1"=3' GENERAL NOTES LEGEND Existing Grade New Grade Granular Backfill SCALE: 1" = 30' PLAN & PROFILE (STORM) 1 TAC COMMENTS 12/20/2019 The storm sewer system shall be constructed per design specified and as approved by the City of Carmel on the final approved construction plans. Deviations from the approved design shall only be permitted due to special circumstances or difficulty during construction and will require prior field approval from a designated representative of the City of Carmel in addition to supplemental approval by the design engineer. An explanation of any such deviation shall be included as a requirement on as-built/record drawings submitted for release of performance guarantees. Approved design slopes identified as generating velocities of 2.5 fps or less or 10 fps or greater (at full flow capacity) shall require as-built certification at the time of construction, prior to backfilling the pipe. The contractor is instructed to as-built each section of storm pipe as it is being installed to ensure compliance with the design plans and as approved by the City of Carmel. AS-BUILT NOTES 2 TAC COMMENTS 1/3/2020 2 GRANULAR BACKFILL NOTES ·For RCP storm pipe granular backfill, refer to detail 3, sheet C601. ·For HDPE storm pipe granular backfill, refer to detail 4, sheet C601. · For PVC sanitary sewer, see Carmel Utilities Trench Detail & Trench Schedule on sheet C606. 05/27/20