HomeMy WebLinkAboutL001 - Site OverviewFDC
C.O.TYPE II
C
.O.
T
Y
P
E
II
C.O.TYPE II6''SSD6''SSD
6'
'SSD6''SSD6''SSD6''SSD6''SSD6''SSD
6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD
6''SSD6''SSD6''SSD6
'
'SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD6''SSD
6''SSD6''SSD
6''SSD6''SSD
6''SSD6''SSD
6''SSD6''SSD6 ''S S D6''S S D 6''SSD6''SSD6''SSD6''SSD
6''SSDRD
RD RD
RDRDRD RDRD
RDRD
RD RD
RD RDRD RDRDRD
RD
RDRD
RDRDRD
NO PARKINGNO PARKI
NGNO PARKING
C
.
O
.
T
Y
P
E
I
C
.
O
.T
Y
P
E
I
C
.
O
.
T
Y
P
E
I
C
.
O
.T
Y
P
E
I C.O.TYPE I6''SSD6''SSD6''SSD6''SSD6''SSD 6''SSD 6''SSD6''SSD6''SSD6''SSD 6''SSD 6''SSD6''SSD 6''SSDSTOPSTOP
DO NOTENTEROHU OHU OHU OHU OHUOHU OHU OHUOHUOHU OHU OHU OHUOHU OHU OHUOHU OHU OHU OHU OHUOHU OHU OHU OHU OHUOH U OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUOHU OHU OHU OHU OHU OHUOHU OHUOHU OHU OHUOHU OHUOHUOH
U
OHU OHU OHU OHU OHU OHUN89°45'41"E (M) EAST (R) 653.40' N00°00'09"E (M) NORTH (R) 1000.00' N6
2°18'51"W 145
.
88'
CH LEN=111.22'N00°00'09"E (M) NORTH (R) 1000.00' N46°29'09"E 118.03'251.37'S00°00'09"W (M) SOUTH (R) 1000.00'S00°00'09"W (M) SOUTH (R) 1000.00'S90°14'41"W (M) WEST (R) 653.40'
STO
P
STOP
STOPBUSONLYDRIV E T O BE CONSTRUCTED B Y OTHERSWALK TO B E CO NSTRUC TED BY OTHERS30'-0" D Buffer
5'-0" A Buffer
30'-0" D Buffer
30'-0" D Buffer
15'-0" C Buffer
30'-0" D Buffer
20'-0" Electrical Easement
56'-0" Dedicated ROW
Future 4th Ave SE Extension
25'-0" Setback
35'-0" Setback
25'-0" Setback
20'-0" Setback
PROPOSED
BMP &
ACCESS
EASEMENT
30'-0" Sanitary Easement
25'-0" Setback
25'-0" Typ.
10'-0" Walk Typ.
0
Scale 1" = 60'-0"
120'60' 30'
North
Zoned: R2
SETBACK
N - 35'
W - 25'
S - 20'
E - 25'
Required Parking:
1 space per employee (80)+ 2 spaces per
classroom(32) = 144 SPACES
5 ADA SPACES
Proposed Parking:
114 PARKING SPACES and 36 spaces
within overflow lot to north eventually,
agreement to share use of Library Garage.
During peak parking events + 70 spaces if
we double stripe the bus lot for overflow.
5 ADA SPACES
12 BUS SPACES PROVIDED
Stacking:
76 DOUBLE CAR STACKING CAPACITY
10 SINGLE CAR STACKING
Required Bicycles Parking Fixtures:
1 per 20 students(750)= 37 bicycle
fixtures
Proposed Bicycle Parking fixtures: 37
Current Building: 76,470 sqft
Proposed Building:111,802 sqft
Proposed:
Employees: 80
Classes: 32
Max Students: 750
NOTE: This Sheet is for
Information Only. Refer to
L100-L205 for Site Material
Plans and Layouts. Refer to
Civil Series For Detailed
Utility / Utility Information.
18'-0" typ.
9'-0" typ.
25'-0" typ.
Curbed Parking Lot, typ.
Bicycle Parking
Mechanical Room
Refer to Architecture Series
HVAC on top of building
Refer to Architecture Series
BUFFER
NW - A - 5'
NE - D - 30'
WN - D - 30'
WS - C -15'
S - D - 30'
E - D - 30'
Proposed Building
111,802 sq. ft.
FFE: 855.80
3 1.Addendum #03 12-20-2019
5 2. TAC Comments 01-03-2020
6 3. ASI #001 02-17-2020
6
6
05/27/20