Loading...
HomeMy WebLinkAboutL206 - Layout Plan23'-3" (4 eq) 13'-1" (2 eq) 2'-4" 25'-9" (5 eq) 2'-4" 16'-8" (3 eq)4'-6"8'-7" (2 eq) 10'-0" (2 eq) 8'-7" (2 eq)4'-6" R5'-0"R5'-0"R5'-0"R5'-0 "8'-0" 8'-0"2'-4"2'-4" ejejejejej 12'-0" (2 eq)3'-0"7'-10"5'-0" 26'-6" (5 eq) 5'-0" 5'-5"17'-11" (3 eq)7'-11" 10'-0"7'-11" 17'-11" (3 eq)ej ejejej 11'-11" (2 eq) 5'-2" 3'-3" 5'-2" 3'-3"10'-0" (2 eq)R4 5 ' - 0"17'-11" (3 eq)R5'-0"8'-0" 7'-11" (3 eq)10'-0" (2 eq) 8'-0"26'-6" (5 eq)ejejejejej ej ej ej 16'-8" (3 eq) 2'-4" 10'-4" (2 eq) 15'-5" (3 eq) 2'-4" 13'-1" (2 eq) 1'-7" 3'-3" 5'-2"2'-8"2'-4"8'-7" (2 eq)10'-0" (2 eq) 8'-7" (2 eq)2'-4"2'-8"R5'-0"R5'-0"5'-0" 5'-0" R5' - 0"17'-11" (3 eq) 8'-0" (2 eq)4'-2"20'-7"5'-8" 5'-6" 25'-0" (5 eq)R15'-0"10'-0" (2 eq)7'-11" (2 eq)ej16'-4" (4 eq)15'-11" (4 eq) 4'-7" 12'-0" (2 eq) 4'-4" 12'-0" (2 eq) 12'-0" (2 eq) 4'-4" 6'-9"4'-9" 4'-9" 10'-0" (2 eq) 6'-1"3'-4"4'-8"2'-4"8'-0" (8 eq) 4'-7"2'-1"39'-3"68'-1" (13 eq) 18'-1"39'-3"16'-4"R2 5 ' -0" R25'-0"39'-3"39'-3"18'-1" 29'-1" 43'-4"4'-0" R25'-0"R25'-0"5'-5"6'-6"41'-4" (8 eq)10'-0"10'-0" 4'-9"4'-9" 68'-4" (13 eq) 4'-9" 11'-11" (2 eq)ejejejejej ej ej ej ej ej 11'-11" (2 eq)3'-4"6'-1"4'-9"10'-0" (2 eq)4'-9" 6'-9" 15'-10" (4 eq) ej ej 57'-10" (11 eq)15'-11" (4 eq) 16'-4" (4 eq) 16'-4" (4 eq)19'-6" (4 eq)6'-0"3'-11"6'-0"4'-0" 20'-0" (4 eq) ej ej ejej17'-10" (3 eq)29'-10" (6 eq) 54'-5" (11 eq) R5'-0"R3' -0 " R5' - 0 "R3'-0"4'-10"10'-0" (2 eq) 4'-10" 4'-10"4'-10"7'-0" 9'-0" 12'-8" (2 eq) 8'-0" 4'-2" 4'-2" 8'-0" 4'-11"8'-0" ej10'-0" (2 eq)1. Dimensions are shown to Face of Curb unless otherwise noted. 2. Contractor shall coordinate final joint locations in the field with the Landscape Architect. Align to existing conditions when practical, including at building and wall corners, connections to existing work, and to centerlines of doors. 3. Space control joints evenly between all bands and expansion joints as shown, unless otherwise dimensioned. Space interim joints equally whenever possible. 4. Digital AutoCAD files will be provided to the successful bidder as a courtesy to assist with field layout. The Contractor maintains all responsibility for the use, accuracy, and confirmation of such data. 5. All pavement striping shown shall adhere to Specifications. The Contractor shall include in their bid any miscellaneous copy, striping, or curb painting that may be requested by the Fire Marshal. 6. All disturbed areas not proposed to receive pavements shall be dressed with topsoil and seeded per Specifications. 7. All angles are 90 degrees unless otherwise noted LAYOUT NOTES 1 2 3 4 0 Scale 1" = 10'-0" 20'10' 5' North Proposed Building 111,802 sq. ft. FFE 855.80 Proposed Building 111,802 sq. ft. FFE 855.80 Proposed Building 111,802 sq. ft. FFE 855.80 Proposed Building 111,802 sq. ft. FFE 855.80 05/27/20