Loading...
HomeMy WebLinkAboutA000.3PLOTTED: May 18, 2020 / Kamlesh Bisht / 2596-IN-GENEVA-ET01.DWG A3-ET01 3FB.3English Tudor2 Car Side EntryFront ,Rear ,Side Elevation's and Roof PlanIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2020 Zach Bittner3/30/2015 GARAGE LEFT 2596-Geneva 1836.0000 LOT 19 05/12/2020 1214 8:12 \A1;4'-0"+12"+ 6"\A1;9'-0" + 0"2030 FX2030 FX2030 FX\A1;R5'-9{\H0.750000x;\S1#4;}"4:12 6:12 \A1;16'-9{\H0.750000x;\S1#2;}" 8:12 \A1;R7'-1{\H0.750000x;\S1#4;}" \A1;7'-6"\A1;2'-1" \A1;3'-1" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION SOLDIER COURSE, PER SPEC ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC4" FRIEZE, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC BRICK VENEER, PER SPEC 1214 1214 1214 FYPON# LV12X36 OR APPROVED EQUAL SCALE:FRONT ELEVATION1/4" = 1'-0"- OPT. METAL ROOF, PER SPECFYPON# LV12X36 OR APPROVED EQUAL FYPON BRACKET #DTLB6X6X5 OR APPROVED EQUAL 6" BATTENS @ 18" O.C. O/ HARDIE PANEL (SMOOTH) 6" TRIM BD., PER SPEC 8" TRIM BD., PER SPEC 6" ROUGH TIMBER TRIM BD., PER SPEC4" FRIEZE, PER SPECSTONE CORBEL, PER SPEC BLACKOUT WINDOW, TYP. \A1;2'-1" \A1;4'-0" + 6"+8.5" +8.5"+ 6"\A1;9'-0" \A1;5'-6"+ 0"+ 0" 1214 STONE SILL, PER SPEC 18"x72" SHUTTERS, PER SPECBRICK VENEER, PER SPECSTONE VENEER, PER SPEC 14:12 8:128:12 8:12 \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. "A"3670ROOF AREA:SQ. FT. 14:12 14:12 14:12 \A1;16'-0" \A1;26'-0" 6:12 4:1214:1214:12 \A1;8'-0" 14:12 \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP.14:1214:12 8:12 14:12 14:12 8:128:12 8:128:12 6:12 SCALE:ROOF PLAN1/8" = 1'-0"- ROOF SHINGLES, PER SPEC 1x3 OVER 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPECMASONRY WRAP, PER SPEC TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-7{\H0.750000x;\S1#2;}" SCALE:LEFT ELEVATION1/8" = 1'-0"- 128 128 128 126 \pxt9;STONE VENEER, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPEC 4" FRIEZE, PER SPEC10" FRIEZE, PER SPEC \A1;3'-6"\A1;MIN. 126 128 128 \A1;2'-1" 128 SCALE:RIGHT ELEVATION1/8" = 1'-0"- 126128 126 MASONRY WRAP, PER SPEC 4" CORNER BOARD, PER SPEC8" FASCIA, PER SPECROOF SHINGLES, PER SPEC8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK SOLDIER COURSE, PER SPEC STONE VENEER, PER SPEC\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-7{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;3'-6"\A1;MIN. 10" FRIEZE, PER SPEC124 BRICK VENEER, PER SPECSTONE SILL, PER SPEC\A1;2'-1" \A1;9'-0"\A1;WINDOW HEAD HT.\A1;11'-1{\H0.750000x;\S1#8;}"\A1;PLATE HT. SCALE:REAR ELEVATION1/8" = 1'-0"- TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF SLAB OPT. MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC 8" FASCIA, PER SPECROOF SHINGLES, PER SPEC 121412146:12 1214 \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-1{\H0.7x;\S1#8;}" \A1;2'-0" \A1;8'-7{\H0.750000x;\S1#2;}"\A1;6'-8" ELEVATION ET01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3670 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.89 6.12 6.35 50.41 15 0 AT EAVE 7.34 6.12 6.25 49.59 0 90.00 TOTAL (MIN)12.23 12.23 12.60 100.00 3 HIGH - RIDGE VENT 4.89 6.12 6.25 49.45 0 0 50.00 AT EAVE 7.34 6.12 6.39 50.55 0 92.00 TOTAL (MIN)12.23 12.23 12.64 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 05/28/20 William Hohlt