HomeMy WebLinkAboutA1.3 - REFLECTED CEILING PLANPI'
�
— — — I � I
— — — �. — — — — — — — — — . — — — — — — — — — — — — — —. — — —. — — —. — — —. — . — — —
� I
_ _ — �� — — — — — — — — — — — — — — — — . � . — — — — — — — — — — — — — — — — + — _
I CPl CP3 CP6 CP]
I I � � O O
I I Ei � Ei � I Ei ei I
/ �, '�, 9=5
�I I � P� � I �p � I �
I i II I �"'i O "
QI2 RI1 R2 RI3 Ri6
J � � J
I �� I � ��
I � � I I � � I
— — — — — — — — — — — — — — —i— — — — — — — — — — — — — — — —.— — —i— —I —.— — — — — —I — — —.— — — — — — —I — —I — — — — —.— .f — 23.1
�
�
�
O
� i�� � � �ii � � � � �� �
il � i � i �^
�� I u
I I � n li � II
I � . II � �� � II
I I, ./��, �llul I t� I I �lluJ
i � � �� � i
I I li v-' i u
� i u
i I I II � I II
I
I I � � I
I III � II
I �I ea I eo
I CPl CP3 CP6 CP] I
II � I � I
� II �I
J CP9 � I � I
� � � O �
II K �� , I E� II
iEo � Eo y Eo , Ea y
----III—I /
I�I
REFLECTED CEILING PLAN
sca�e va. = i,o.
�
R,
CGI CG3 CP6 CP]
���OEz
I \
Rz
-.-�T-�PE� ��
'O �
a + — — — — — — — + — — —
iz�',
., .�'. '., I
..��y' �C' .•'.. I
o � ', �I�, ��� I I
� i \
� I �
� y �,a�° � I C rt — —
�
� ��` ' ��� � ���; � ^ 0�_ i i
i i
i ` i
�
� R1 __ __ �, I I
I --- —_— J--�--�
I _ --__L_1'
j� � , � — � ,
I �' I I
I \ I
i � = i
II R1 I I
� PEN
O
�__ �,.9
ORz
CPR
GENERAL CEILING NOTES:
1. MECHANICALANDELECTRICALISDESIGN-BUIL�.DESIGN-BUILDCONTRACTOR&ENGINEERTO
VERIFY EXISTMG CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW
�IFFUSERS, SPRMKLER HEA�S, FIRE PROTECTION DEVICES, E%IT LIGHTS. EMERGENCY NIGHT
LIGHTS, AND THERMOSTATS. �ESIGN-BUIL� CONTRACTOR TO COOR�INATE HIS WORK WITH
THE LIGHTING PLAN. ALL �UESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL DRAWMGS FOR RELOCATION OF
THERMOSTATS.CONTRACTOR TOVERIFVWITHTENANTTHERMOSTATLOCATIONSFOR
FURNITURE LOCATION CONFLICTS BEFORE PROCEEDING.
2 ELECTRICALCONTRACTOR&ENGWEERISRESPONSIBLEFORDESIGN-BUILDOFALLSAFETY
SYSTEMS. ENGINEER IS TO VERIFV QUANTITYAND PLACEMENT OF IN�ICATED SAFETY
DEVICES (E%IT SIGNS. ALARMS. ETC.J AND VERIFY CONFORMANCE WITH LOCAL AND STATE
CODES. DESIGN BW�o CONTRACTOR IS RESPONSBLE FOR SUBMITTING NECESSARV
DRAWINGS & ENGWEERED CERTIFlCATION CALCl1LATI0N5 AN� SPECIFICATIONS FOR REVIEW
AN� OBTAINING PERMITS. CONTRACTOR IS RESPONSBLE FOR SUBMITTING DRAWINGS TO
ARCHITECT FOR REVIEW AND COOR�INATION OF LOCATION OF DEVICES.
3. ALLWALLS GOTO DECKABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR
OTHER WALL TYPE INFORMATION.
G. CONTRACTORTOVERIFVERISTINGWN�ITIONSTOLAYOUTANDREPORTANY
DISCREPANQES TO DESIGNER BEFORE PROCEE�ING WITH CONSTRUCTION.
5. CEILINGHEIGHTISINDICATE�BYBENCHMARKUNLESSNOTEDOTHERWISE.
6. PROVIDEFIRERATEDDAMPERSREQUIREDATFIRERATEDWALLS.
7. ALLEMERGENGYDEVICESTOBECOLORWHITE.
8. LIGHTFIXTURESARETOBECONTROLLE�BYTIMERSYSTEMASREQUIRE�BYELECTRICAL
CODE. OVERRIDE SWITCHES OR DIMMERS ARE TO BE PROVIDE� AS NOTED FOR EACH ROOM.
WHERE MULTIPLE SWITCHES OR CONTROLS ARE IN CLOSE PROXIMITY, THEYARE TO BE
CONSOLI�ATED TO A GANG PLATE GONDITION.
9. ALL LIGHT FIXTURES TO BE 3500N UNLESS NOTEo OTHERWISE.
:
.
:�
.�
:
--- z,4
CEILING PLAN NOTES:
OEXISTINGOPENCEILINGTOREMAIN.TOUCHUPPAINTASNEEDE�DUETONEW
CONSTRUCTION.
OEXISTINGCEILINGTOREMAIN.REPLACEANVDAMAGEDORSTAWEDTILES.
cv3 EXISTING LIGHTS TO BE REUSEDAS NOTED M LEGEND. REPLACE MISSING OR NON-
WORKING LAMPS.
caa PROVIDECONTROLSFORTHESHOWROOMATTHISLOCATION.
O PROVIDEOCCUPANCYSENSORS.
OPROVI�ELIFESAFENITEMSASREQUIRED.
°P SPLITTHEEXISTINGHVACSVSTEMBETWEENTHETWOSUITES.MOVEORADDUNITSAND
DUCTINORK AS NEE�Eo FOR THE NEW LAYOUT TIE IN POWER FROM THE TENANT-S NEW
PANEL. USE SPIRAL oUCT IN OPEN CEILING AREA. ALL EXPOSED MECHANICAL AN�
ELECTRICAL ITEMS ARE TO BE PAIMED TO MATCH THE CEILING. INCLUDE REMOVAL FROM
THE BUILDINGS FRESH AIR SUPPLY AND ADD �EDICATED FRESH AIR. INC W DE THIS AS A
VANILLABOX WST.
OPAINTSTARANDMOONLIGHTFlXTUREP7.INCLUDEHEMWAYGLITTERPAINTAD�ITNE-
W LOR TB�. BUFFAFTER SURFACE IS DRV
v PROVI�ENEWSUSPENDEDCEILINGTOBE'.ARMSTRONG,DUNE,2X2ANGLEDTEGULAR
WITH PRELUDE XL 15/i6` GRID.
OPROVIDEEXHAUSNENTDIRECTLYTOTHEEXTERIOR.
�P�� REMOVELIGHTSFROMADJACENTTIMERAN�PROVI�ENEWLIGHTINGCONTROLTIMER
� SYSTEMFORTHISSUITEWITH�6)ZONES.PROVIDE�i)ZONEFOREXTERIORSIGNAGE.
O
— — III— It —
i �� � ��
��� I I�
�+ � I
I I
� veu III III
t
n I
— — — — rt
REFLECTED CEILING LEGEND:
E��R� EXISTING(Ei)ORRELOCATED(Ri)LINEARFLUORESCENTFIXTURESARE:FOCALPOINT,
EVOLUTION, FEVS-PLdTB-0GXXX-EC96-TS-8'. FIMURE IS TO 8E MOUNTED AT 72' AFF
O0 EXISTING�E2)ORRELOCATE�(R2�PEN�ANTMOUNTEDLIGHTFIXTUREARE:FOCAL
Ei,Ez POINT, GROOVE E, FGR-E-2L2TT-S-X%k-C144-WD-NA. LIGHT FIXTURESARE
MOUNTED AT 12' AFF TO THE BOTTOM OF THE FIkTURE.
� EXISTINGTRACK LIGHTING I5: CONTECH LIGHTING, LED TRACN LIGHT FIXTURE,
° CTL8071M3D-B. MOUNTAT 70'AFF TO BOTTOM OF TRACK.
NEW 2' X 2' LED TROFFER FIXTURE TO BE: CREE, ZR2232L35L-10V, 35W LIGHT TO
OCCUPANCYSENSOR.
O "
O
�
g(
/� \ �
I�
ffi
FlXTURE.
TENANT SUPPLIED STAR AN� MOON FI%TURE.
TRACKLIGHTINGRELOCATEDFROMTENANTSCURRENTLOCATION. HEIGHTTOMATCH
ADJACEM EXISTING FlXTURES.
CHANDELIER PROVIDED BY TENANT.
EXISTING CEILMG FAN TO BE: REGENCV, INDUSTRIAL, IND-WH. MOUNT AT iT TO THE
BOTTOM OF THE FAN. PROVI�E MULTIPLE FAN SPEE� CONTROLLER.
NEW CEILING MOUNTE� EXIT LIGHT W/ �IRECTION
EATON. SURELITES E�GELIT EXIT SIGN, EU551R OR EQUAL.
NEW �UAL HFAD EMERGENCV LIGHTTO BE:
EATON, SURELITES EMERGENCV LIGHT, APELH2W OR EpUAL.
I_�
-0
■ EXISTINGEXHAUSTGRILLEINCEILINGFORUSEWITHBUILDING'SEXHAUSTSYSTEM.
� EXISTING2'X2'SUSPENDEDCEILINGTOBE'.ARMSTRONG,RANDOMFISSUREDW/15/16PRELUDE
XL GRID. CONTACT PHILIP CAITO, 317.5192829.
�EXISTING�ECORATNESUSPENDEDCEILINGTOBE:ARMSTRONG�CAPZOPTIMA3933WH.SL�
4'XB' PANEL WITH SILVER CAPS. MOUNTAT 10' AFfi CONTACT PHILIP CAIT0.3P.5192829.
❑ GYPSUMBOAR�CEILINGTOBEPAINTE�PS.
g Two wnv swiTcr+.
�p oiMMERswiTCH.
NL NIGHTLIGHTLOCATIONWITHEMERGENCYBATfERVPACK.
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
�!,,:,�r; ,�;va�n�!
���
CARMEL
CITY CENTF.R
PEDCOR DESIGN GROUP
Archi�ec[ure I Projec� Managment
355 City Center Drive
Carmel, Indiana 46032
31�]05�9�9 (phone)
3177057980 (fex)
Amhi�ect:
723 HANOVER PL
724 RANGELINE
PLAZA LEVEL T'—`
KEY PLAN r,
NTS /�1
W
�eveloper:
P� pE�D C O R
DEV�(OPME���.
Pmjec[:
��/
L.L
W �
J W �'
OQ��
�� ��M
m�U��
Q -J �+ NA Z
Y � }r 1 _
_ �,
��U��
W � a �
� � � �, �
� L p
� (� c
Y U=
�
N
�
Issue Date Drawn By Checketl By
ovzazozo r� xc
Revisions:
State Release Set: 012420
S�ate Release Addendum: 03.3� 20
ProjecWumber:
Sheet Ti�le:
REFLECTED
CEILING PLAN
Sheet Number:
��l •e�
DATE: Q�j�Z8�2O