Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A104 First Floor Construction Plan
UP UP DN WasherDryer DWMicrowave Ref. Range U.C. Refr. A4011 A402 A402 A401 2 1 2 29' - 10" CLR. 3' - 0"17' - 4"35' - 0" 3' - 10" 3' - 4 1/2"3' - 4 1/2" ø 5' - 0"2' - 0" 4' - 0 7/8" 0' - 4 1/2" 5' - 0" 1' - 4" Crate 30"x42" Crate 30"x42" Crate 30"x42" Crate 30"x42" Cupboard by Owner2' - 6 3/8"5' - 3" 5' - 3" 2' - 10 7/8" 3' - 11 3/4" 9' - 7 1/4" 5' - 5 3/4" Cubbies & Storage Closet12' - 0 5/16"1' - 0" 4' - 2" HVAC LOCATION (SERVES 2ND FLOOR) Possible future elevator location. Aligns with office closet on 2nd floor. Putting elevator here is an option but requires relocation of the HVAC system to the right, and a platform and reconfiguration of garage door to keep floor level the same as main level of house. ENTRY 101 ART ROOM 102DINING 103 THEATER 104 KITCHEN 105 PANTRY 106 CUBBIES 107 BATH 108 HALL 109 LAUNDRY 110 DOG WASH 112 LIVING ROOM 113 GARAGE 114102A102B 104A104B 106105A110112A 112B 105B 102A10' - 1 1/2" 2' - 6" 17' - 2 1/2" 12' - 7 1/2" 35' - 10"EQ EQ11' - 7 1/2"4' - 3 3/4" 2' - 2 3/4" 7' - 2" 10' - 0"EQEQ5' - 10 1/2" 8' - 6 1/2"4' - 1"56' - 2"59' - 6"10314' - 10" 5' - 0" 5' - 0" 5' - 0" B B A601 1 2 3 4 A601 6 5 7 A601 8 A6024 A602 3 2 1 A601 9 10 1 A501 4 A501 2 A502 1 A502 5 A5015' - 9 3/8" 4' - 0"2 A501 F F R 2' - 0"ALIGN HEADER B B 113BLACK STEEL DOOR AND WINDOW FRAME, BY CRITTALL OR PORTELLA. SUBSTITUTION REQUESTS MUST BE PROVIDED IN WRITING TO ARCHITECT FOR REVIEW. FRZ. 0' - 6" 2' - 6" 2' - 0" 1' - 3"1' - 3" 2' - 0" 0' - 1" 3' - 0" 0' - 1" 1' - 6"102CNEW SINK 30"X66" DH 30"X66" DH 24"X24" TRNSM 52"X82" FRENCH DOORS FULL GLASS (2) 36"X80" POCKET DOORS W/ FULL GLASS (2) 36"X80" POCKET DOORS W/ FULL GLASS 36"X80" 36"X80" W/ 18"Ø PORTHOLE (PR.) 36"X96" FULL GLASS 36"X82" 1/2 LITE WITH DOG DOOR 36"X80" 36"X80" 8'-0" X 7'-6" 36"X80"36"X82" FULL LITE H H 30"X54" DH 30"X54" DH 001 Dogwash, Forever S.S. AR48HT B 30"X66" DH WITH OBSCURED GLASS 30"X66" DH 30"X66" DH 42"X78" FX 42"X78" FX A A 73"W BANQUETTE PROVIDED BY OWNER A602 5 F BUILT-IN BOOKSHELVES -REFER TO INTERIOR ELEVATION CONSTRUCTION LEGEND GENERAL CONSTRUCTION NOTES DENOTES AREA NOT IN CONTRACT 1. DOORS NOT INDICATED BY A DOOR NUMBER DESIGNATION ARE EXISTING. 2. PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES. PATCH AND REPAIR AS REQUIRED. 3. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT. 4. REMOVE EXISTING SWITCHES THAT ARE NOT REUSED. REMOVE CONDUIT AND WIRING BACK TO NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH. 5. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK. 6. CEILING HEIGHT THROUGHOUT THE SPACE IS 9 FT (NOMINAL) A.F.F., EXCEPT IN DOG WASH WHERE IT IS 7'-6" (NOMINAL). 7. ALL CEILINGS THROUGHOUT SHALL BE SKIMMED AND PAINTED A SMOOTH FINISH WITH NO TEXTURE. 8. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE. MOUNT +48" A.F.F. TO CENTER OF DEVICE. 9. COLOR OF LIGHT SWITCH DEVICES AND COVERPLATE TO BE BUILDING STANDARD, UNLESS NOTED OTHERWISE. 10. ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE DEVICE COVERPLATE. 11. THERMOSTATS SHALL BE LOCATED DIRECTLY ABOVE OR ADJACENT TO LIGHT SWITCH. ALL THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE PLACEMENT. 12. ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE. 13. IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE DESIGNER PRIOR TO INSTALLATION. 14. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DUCTWORK, SUPPLY AND RETURN AIR AND THERMOSTATS. COORDINATE ALL ELEMENTS OF THE HVAC SYSTEM TO PROVIDE A COMPLETELY BALANCED AND EFFICIENT HEATING AND COOLING SYSTEM. 15. VERIFY AND REWORK EXISTING DUCTWORK AND THERMOSTATS AS REQUIRED. 16. MECHANICAL CONTRACTOR SHALL VERIFY WORKING CONDITION OF ALL EXITING THERMOSTATS, EXHAUST FANS, AND ANY OTHER DEVICE DIRECTLY RELATED TO THE HVAC SYSTEM. CONTRACTOR TO NOTIFY ENGINEER/DESIGNER IMMEDIATELY UPON DISCOVERY OF DEFECTIVE DEVICE. NEW WALL CONSTRUCTION EXISTING WALL OBJECT TO BE DEMOLISHED STATE OF No. AR11700002JOSEPHE.LE S ERE G I STERE DREGI S T ERED A R C H ITECTINDIA N A SHEET NUMBER SHEET TITLE DRAWN BY: REVIEWED BY: PROJECT NUMBER NO. DATE DESCRIPTION CERTIFICATION PREPARED FOR PROJECT ©2018 All Rights Reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information retrieval system, without the permission of the copyright owner. Any unauthorized users will be prosecuted to the fullest extent of the law including any legal fees incurred by the copyright owner. IN ASSOCIATION WITH PROGRESS STUDIO, LLC 5915 N. College Ave., Suite 213 Indianapolis, IN 46220 317-978-1100 www.theprogressstudio.com - 4/9/2019 EXISTING PLANS REVIEW - 4/19/2019 REVIEW SET - 4/28/2019 REVIEW SET - 5/6/2019 BID SET - 04/30/2020 PERMIT SET - 05/18/2020 CARMEL COMMENTS #1 Brad & Carol Catlin Catlin Residence Reno & Addition 10100 Shelborne Road Carmel, IN 46032 Author Checker 19027 A104 FIRST FLOOR CONSTRUCTION PLAN 10100 Shelborne Road Carmel, IN 46032 1/4" = 1'-0" FIRST FLOOR CONSTRUCTION PLAN1 05/29/20 David Rutti