HomeMy WebLinkAboutS101 Foundation Plans and DetailsGFCIFOUNDATION NOTES
1. FOUNDATION NOTES: STEP FOUNDATION AT EAST EDGE OF
PROPERTY DOWN TO EXISTING FOUNDATION. MAXIMUM SLOPE
IS 2 HORIZ., 1 VERT. BETWEEN FOOTINGS AT DIFFERENT
ELEVATIONS.
2. ALL FOOTINGS TO REST ON CLEAN, FIRM UNDISTURBED SOIL.
STEP FOOTINGS A REQUIRED TO MAINTAIN REQUIRED DEPTH
BELOW FINISH GRADES.
3. CONCRETE STRENGTH, 3,000 PSI AT 28 DAYS FOR ALL SLABS.
(FOUNDATION DESIGN BASED ON 2,500 PSI). 3,000 PSI AT 28
DAYS FOR ALL OTHER CONDITION. MAXIMUM SLUMP, 4"
4. USE ASTM A-615 GRADE 60 DEFORMED REINFORCING BARS
UNLESS NOTED OTHERWISE
5. CONCRETE EXPASION ANCHORS SHALL BE 'SIMPSON WEDGE-
ALL STUD ANCHORS' OR ENGINEER APPROVED EQUAL. EPOXY
TO BE SIMPSON "SET" ADHESIVE OR APPROVED EQUAL.
6. INFILTRATION, ALL OPENINGS IN THE EXT. BLDG. ENVELOPE
SHALL BE SEALED AGAINST AIR INFILTRATION. THE FOLLOWING
AREAS MUST BE SEALED. * JOINTS AROUND WINDOW AND
DOOR FRAMES * JOINTS BETWEEN WALL CAVITY AND
WINDOW/DR. FME. * JOINTS BETWEEN WALL AND FOUNDATION
* JOINTS BETWEEN WALL AND ROOF * JOINTS BETWEEN WALL
PANELS * UTILITY PENETRATIONS THROUGH EXTERIOR WALLS
A. FLOOR/ROOF FRAMING / TRUSS NOTES: FRAMING DRAWING IS FOR
ILLUSTRATION ONLY. ALL FRAMING SHALL BE INSTALLED & BRACED TO
MANUFACTURERS DRAWINGS & SPECIFICATIONS.
B. ANY ENGINEERED WOOD PRODUCT SHALL CARRY MANUFACTURERS
STAMP.
C. ANY ENGINEERED WOOD PRODUCT WILL NOT BE FIELD ALTERED
WITHOUT PRIOR BUILDING DEPT. APPROVAL OF ENGINEERING
CALCULATIONS.
D. ANY ENGINEERED WOOD PRODUCT SHALL HAVE DESIGN DETAILS &
DRAWINGS ON SITE FOR FRAMING INSPECTION.
E. ALL CONNECTIONS OF RAFTERS, JACK OR HIP TRUSSES TO MAIN
GIRDER TO BE PROVIDED BY LUMBER COMPANY / MANUFACTURER.
F. ALL ROOF FRAMING 16" O.C. UNLESS NOTED OTHERWISE.
G. INSTALL SPRAY FOAM TYPE INSULATION AT FLOOR AND PLATE LINES,
OPENINGS IN PLATES, CORNER STUD CAVITIES AND AROUND DOOR
AND WINDOW ROUGH OPENING CAVITIES.
H. MIN. SNOW LOAD 50 LBS PER SQUARE FOOT.
I. ALL EXPOSED INSULATION IS TO HAVE A FLAME SPREAD RATING OF
LESS THEN 25 AND A SMOKE DENSITY RATING OF LESS THAN 450.
J. SPECIFIC MANUFACTURES AND MODEL NUMBERS SHOWN ON THE
PLANS ARE INDICATIONS OF QUALITY ONLY. THE OWNER/BUILDER
SHALL NOT BE PROHIBITED FROM SUBSTITUTING MATERIALS AND/OR
APPLIANCES OF EQUAL QUALITY/STRENGTHS FROM NON-SPECIFIED
MANUFACTURERS.
K. THE OWNER/BUILDER SHALL NOT BE SUBSTITUTING MATERIALS
PROVIDED THEY MEET CURRENT BLDG. CODE, AND ARE APPROVED
FOR THAT SPECIFIC USE BY THE BUILDING OFFICIAL.
L. ALL WOOD JOISTS, POSTS, LAP SIDING, STRINGERS, PLATES, ARE TO BE
OF TREATED WOOD PRODUCTS WITHIN 12" OR LESS OF CONTACT OF
GRADE OR WITH DIRECT CONTACT TO CONCRETE. WOOD OVER
CRAWLSPACE OTHER THAN WOOD PLATES IN CONTACT WITH
CONCRETE ARE TO BE ENGINEERED WOOD PRODUCTS WITHIN A
CONDITIONED CRAWLSPACE ENVIRONMENT.
FRAMING NOTES
4
A501
2
A502
1
A502
5
A50122' - 3"PANEL3'x3'ACCESSCONDITIONED CRAWLSPACE
10 MIL VAPOR RETARDER
OVER 4" COMPACTED
GRANULAR FILL
29' - 10"17' - 4"15' - 11 1/4" 19' - 0 3/4" 3' - 10" 11' - 4" 5' - 10 1/2" 12' - 7 1/2"
29' - 10"
EXISTING
CRAWLSPACE
EXISTING GARAGE SLAB
INFILL WINDOW WITH
CONSTRUCTION MATCHING
EXISTING WALL
EXISTING BASEMENT8' - 8" 8' - 8"11' - 7 13/16"
16"X16" CMU OR POURED CONCRETE
PIER, REINFORCED WITH (4) #4 BENT
REBAR AND 36"X36"x8" SPREAD
FOOTING WITH (3) #4 REBARS EA. WAY
8" REINFORCED CONCRETE
FOUNDATION WITH #4 REBARS AT
24" O.C. EACH WAY AND 16"x8"
CONTINUOUS SPREAD FOOTING
WITH (2) #4 REBARS CONTINUOUS.
2
S101
2
S101
SUMP
EJECT
EJECT
1ST FLOOR
0' - 0"
EXTEND CEMENT BOARD TRIM
TO COVER BASE PLATE
8" REINFORCED CONCRETE
FOUNDATION WALL WITH #4 REBARS
AT 24" O.C. EA. WAY
16"W x 8"H CONTINUOUS FOOTING WITH
(2) #4 REBARS CONTINUOUS TO A DEPTH
OF 30" BELOW GRADE (MIN.)
10 MIL VAPOR RETARDER FULL
AREA OF CRAWL - TAPE / SEAL ALL
JOINTS
SPRAY FOAM INSULATION, R-10
(INCREASE TO R-21 AT RIM JOIST)
FLOOR JOISTS - SEE FRAMING PLAN
WASHED PERIMETER FOUNDATION
GRANULAR FILL AND PERIMETER DRAIN
TIED TO SUMP
#4 BENT REBAR AT 24" O.C.
2X4 TREATED SILL ON SILL GASKET
AND METAL FLASHING WITH DRIP
RIM JOIST - SEE FRAMING PLAN
1/2" ANCHOR BOLT AT 32" O.C.,
MIN. EMBEDMENT OF 7"
AIR BARRIER, "TYVEK" OR
EQUAL, ON 7/16" EXT. SHEATHING
LP SMARTSIDE BOARD & BATTEN
SIDING AND TRIM
3/4" APA-RATED T&G PLYWOOD
SUBFLOOR
2X4 SILL PLATE
COMPACTED GRANULAR FILL, MIN. 4"
STATE OF
No.
AR11700002JOSEPHE.LE
SERE G I STERE
DREGI
ST
ERED A R C H ITECTINDIA N A
SHEET NUMBER
SHEET TITLE
DRAWN BY:
REVIEWED BY:
PROJECT NUMBER
NO. DATE DESCRIPTION
CERTIFICATION
PREPARED FOR
PROJECT
©2018 All Rights Reserved. No part of this publication may be reproduced or
transmitted in any form or by any means, electronic or mechanical, including
photocopying, recording, or by any information retrieval system, without the
permission of the copyright owner. Any unauthorized users will be prosecuted to
the fullest extent of the law including any legal fees incurred by the copyright owner.
IN ASSOCIATION WITH
PROGRESS STUDIO, LLC
5915 N. College Ave., Suite 213
Indianapolis, IN 46220
317-978-1100
www.theprogressstudio.com
- 4/9/2019 EXISTING PLANS REVIEW
- 4/19/2019 REVIEW SET
- 4/28/2019 REVIEW SET
- 5/6/2019 BID SET
- 04/30/2020 PERMIT SET
- 05/18/2020 CARMEL COMMENTS #1
Brad & Carol Catlin
Catlin Residence
Reno & Addition
10100 Shelborne Road
Carmel, IN 46032
Author
Checker
19027
S101
FOUNDATION
PLANS AND
DETAILS
10100 Shelborne Road
Carmel, IN 46032
1/4" = 1'-0"
FOUNDATION PLAN11" = 1'-0"
TYPICAL FOUNDATION WALL2
05/29/20
David Rutti