Loading...
HomeMy WebLinkAboutALB30- Truss LayoutsA1A2A2AA2BA2CA3 A4A5 A5A A4AA4BA4BA4CA4DA4EA6 A6 A3A A3B A3C A3C A7 A7 A7 A7 A8 A9A9A9A9A9A9A9A9A9A9A9A9A9A9A9A9A9AA8A A8B A8C A8D A8D A8D A8E A10 A10A A10A A10A A10A A10A A10A A10A A11 A11 A11 A11 A11 A11 A11A A11A A11C A11D A11D A12 A12 A12 A12A A12B A12D A12E A12FA13A13A13AA13AA13AA13AA13AA13AA13AA13BA13CA13CA13CA13CA13CA13DA13FA13GA13HA14A15A16A16AA16AA16AA16AA16AA16AA16AA16AA17A17A17A17A17A17A17A17 A10C P1 P1 P1 P1 P1 P1 P1A P1A P1A P1A P1A P2 P2 P2 P2A P2B V1BV1CV1DV1EV1FV1GV1HV2 V2A V2B V1V1AV1 V1A P3P3AP3AP3AP3AP3AP3AP3AP3AP3AP3AP3AP3AP3AP3AP3AP3AP4 IMPORTANT THISDRAWING ISFOR FIELD PLACEMENT OF INDIVIDUAL COMPONENTSONLY,ANDDOESNOT CONSTITUTEAN ENGINEERED DOCUMENT. NOTE PROPER BEARING AND BEARING DESIGN INCLUDING ANCHORAGE,ISTHERESPONSIBILITY OFTHEBUILDING DESIGNER,ARCHITECT AND/OR BUILDINGENGINEER. REFER TO INDIVIDUAL TRUSSDESIGNSFOR REACTIONS,MINIMUM REQUIREDBEARINGSIZE,UPLIFT,ANDADDITIONAL LOADS. 84 COMPONENTSDOESNOT ASSUME RESPONSIBILITY IN THESE AREASOF CONCERN. BRACING ERECTION,TEMPORARY,ANDPERMANENT BRACINGISTHE RESPONSIBILITY OF THE CONTRACTOR AND / OR BUILDING DESIGNER. REFER TO INDIVIDUAL TRUSSDESIGNSFOR ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1 SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS ASSOCIATION COMMENTARY,ANDRECOMMENDATIONSFOR HANDLING,INSTALLING&BRACINGMETAL PLATECONNECTED WOOD TRUSSES. www.sbcindustry.com INSTALLATION DO NOT CUT,DRILL,OR ALTER TRUSSES. ANY QUESTIONS CALL 84COMPONENTS. PROPER INSTALLATION,AND HANDLING OF COMPONENTSISTHE RESPONSIBILITY OF THE ERECTING CONTRACTOR. 84 COMPONENTSMUST BE NOTIFIEDOFANY PROBLEMS,ANDAFFORDEDTHE OPPORTUNITY TO REVIEW,ANDMAKENECESSARY CORRECTIONS,OR NO BACK CHARGESWILL BEACCEPTED OR APPROVED. WARNING WARNINGS,ANDINSTRUCTIONSFOR ERECTION OF COMPONENTSARE INCLUDED IN THE DELIVERY PACKAGE. KEEP THISINFORMATION ON THE JOB SITE. THESE DOCUMENTSWILL ALSO BE NEEDED FOR JOB SITE INSPECTION. MISUSE AND IMPROPER INSTALLATION OF COMPONENTSMAY RESULT IN FAILURE,BODILY INJURY,LOSS OFPROPERTY,AND/OR LIFE. RoofArea: Overhang Length: Eave Length: HipLength: ValleyLength: Ridge Length: SHEETNUMBER: R1.1 RoofTruss Placement Plan SCALE: NTS Job#: PO#: Date: 2/5/2020 Drawn By: KLD Designed By: KLD Checked By: ROOF LOADS: TCLL: 20.000 lb/ft² TCDL: 10.000 lb/ft² BCLL: 0.000 lb/ft² BCDL:10.000 lb/ft² Building Code: IRC 2009 Wind Speed: 90.0 mph On-Center Spacing: 24" U.N.O. 5202.96 SF 261.95 LF 147.35 LF 148.77 LF 74.78 LF 79.76 LF ROOF DATA THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDING CONSTRUCTION., ,ROOF TRUSS PLACEMENTPLANOffice:Fax:06/01/20 Adam Schriner