Loading...
HomeMy WebLinkAboutA7-DOOR-SCHEDULE-NOTES-&-DETAILSEA SIDE AME 3 SCHED ��� TYPICAL HOLLOW METAL DOOR IN GWB CONS1RlIC110N i HEAD DETAIL A� SCALE: 1 1/2" = 1'-0" TOP OF METAL DECK BOTTOM OF MiL OECN VERTIIRACK VID 362-16 BY STEEL NETWORK, INC. INSTALL PER MFR RECOMMEN�AlIONS. USE (2) $10 TEK SCREWS � 16" O.G ID EXIS7ING FLOOR �ECK 5/8" G&B METAL STUD PER SCHEDULE PERPENDICULAR TO METAL �ECK - 1" DEFLECTION a SLIP JOINT A% SCALE: 1 1/2" = I'-�" EA SI�E 4ME � SCHED ��j" TIPICAL HOLLOW METAL �OOR IN GWB CONSIRUCTION 2 JAMB DETAIL A% SCALE: 1 1/2' = 1'-0" NOTE: PROVI�E MOISIURE RESISTANT GW BD � ALL WET AREAS NOIE: PROVIDE ANCHORAGE AS SHOWN FOR ALL NEW NTERIOR WALL PARTITIONS. 5/8" GWB BOTH SI�E, FlNISH PER SCHEUDLE MEiAL STUDS PER SCHEDULE METAL TRACK WITH 2-�10 lEKS ATTACHE� � EA 1fi" OC AS REQ WALL BASE EACH SIOE AS SCHEOULE� PROVIDE SEALANT BOhi - /1 SIDES AT BASE OF + �PARTITION AS SHOWN �� x!\ PRON�E MLTI X-U 32 �P8515 � 3'_0" OC CC-ES REPORT ESR-2269 CONC SLAB s WALL ANCHOR DETAIL A� SCALE: 1 1/2° = 1'-0' DOOR, AS SCHED DOOR FRAME BEYOND FIMSH AS SCHED rimsH ns scHco RE�. SHEET A7.1 3 THRESH DETAIL A7 SCALE: 1 1/2' = 1'-0" MINI SPLIT HEAT PUMP SYSIEM TO BE iNSTn��o nccaeoiNc Ta a�� APPLICABLE NAPONAL AN� LOCAL ELECTRICAL, MECHANICAL AN� � BUILDING CO�ES. 30'H SUPPORT ON 1/4'x18"x18" �. � CONDENSING ONIT BOLIED TO ONISIRUT CHANNELS. CLAMP � CHANNELS TOGETHER AND CLAMP TO PIPE Sl1P�RTS. CAP OFF EACH PIPE WAIER-PGHT —REFER TO MANUFACTURER FOft �EFRIGERANT LME lENG7H. RE 4/%N rWEA1HERPRWF FUSEO �ISCONNECT PER NEC �✓`� PIPE SUPPORT ATTACHED TO ROOF �smuc�uRc, Trrica� roR (a) 4� SUPPORTS. FLASHING TO MATCH ROOF MANl1FAC� REOUIREMENiS SEE 3/%%. ROOF-MOUNTED CONDENSING UNIT NoIE: ALL RooF PENE1RAlION WORN To BE PERFORME� BY ORIGINAL ROOFER TO MAINiAM EXISTING WARRANiY. G.C. W COORDINATE W11H CPA1 i0 OBiAIN ROOFERS CONTACT WFORMAPON. �s� CONDENSING UNIT MOUNTING DETAIL ,QJ SCALE: NTS DOOR AND FRAME SCHEDULE 000R FRnME FlRE RA71NG HAR�WARE TYP SIZE LOWER MAn DETAR LABEL SET N0. NOTES MATL GLAZING W� HGT 7ryK W� HGT HEA� JAMB SILL L A 3• 0" 6,_8� 1�•• HM HM 1�A7 2�A7 3/A7 — HWS-02 3 2. B 4'-0" Y-0° 7�j" MFG HM 1/A7 2�A7 3�A7 — HWS-03 S,fi,7 3. C 3' 0•' 6, 8" 1�j" SOLI� WD HM 1/A7 2/A7 3/A7 — HWS-01 1,2,4,8 4. C 3'-0" fi'-8° 1�" gpLl� WD HM 1/A7 2/A7 3/A7 — HWS-01 1,2,4,8 5. C 3'-0" fi'-8" 1'�" SOLI� WD HM 1/A] 2/A7 3/A7 — HWS-01 1,2,4.8 REMARKS. 1. DOOR TO HAVE 1" UNDERCUT 6. FACTORY FINISH 2. PAINi BOTH SIDES OF DOOR AND FRAME PT 7. PAINT DOOR FRAME �PROVIDE KICK PLATES ON 3. PAINi DOOR AND FRAA�E BOTH SIDES OF THE DOOR 4. SOLID CORE WOOD, PRIMED FOR PAINi, KNOCK DOWN HMF 8. STORE ROOIA LOCKSET 5. DOUBLE ACTING iRAFFlC DOORS BY ELAISON W1TH CVS HARDWARE OPTIONS. HARDWARE SCHEDULE HWS-01 HWS-02 HWS-03 HINGES • • LOCKSET • • Pnwc oEvicE c�osER • DOOR STOP • • KICK PLAIE iHRESHOL� SILENCERS • • WEATHER STRIPPING DOOR SWEEP AS7RAGAL RAIN GUAR� FWSH BOLTS NOTES � � � ALL �OOR HARDWARE IS PRONDED BY DOOR MFR HEAO AND JAMB • • SMOKE SEALS VIEWER • GENERAL DOOR HAR�WARE NOlES: 1. �OORS, FRAMES, HARDWARE, AND LOCKING SYS7EM5 SHALL BE PURCHASED FROM 7HE CVS NATIONAL ACCOUNT SUPPLIER 2 DOOR THRESHOL�S AN� 7RANSIPONS SHALL NOT EXCEED 1/7' IN HEIGHT 3. ALL DOOR KNOBS SHALL BE LEVER TWE AND ADA AWESSIBLE 4. DOOR CLOSERS SHALL BE ADJUSTABLE AN� SET TO COMPLY WITH ACCESSIBLE CRIIERIA FOR OPENING IENSION AND CL09NG SPEE�S. 5. FOR CYLIN�ERS AN� KEYING, PROVIDE AS STANDAR� lM7H 7HE MANUFACTURER FOR THE OWNER FOR THE TELESCOPING DOOR SPEQFlED. 6. FOR CONS7RUCTION KEYWG, PROVI�E CONS7RUCTION WRES 7HAT ARE REPLACEABLE BY PERMANENT WRES. PROVIOE QUANPTY AS DIRECTED BY OWNER AND FURNISH PERMANENT CORES TO OWNER FOR INSTALLATION. 7. FOR KEYWG SYS7EM, PROVI�E A FACTORY-REGISTERED KEtlNG SYS7EM AS �IRECiE� BY OWNER. fl FOR KEYS, PRONDE NICKEL-SILVER. STAMPING MUST BE PERA�ANENRY INSCRIBED R77H A VISUAL KEY CON7ROL NUMBER AN� INCLUDE iHE NOTA➢ON "DO NOi DUPLICATE". OUANTITY DETERMMED BY OWNER DOOR TYPES �'�� pharmacy" HUBISSSI STORE NUI�BER 08674 1421 RANGELME ROAD CARMEL, IN 46032 CAPCADE: (90�88) CS PROJECT NUMBHi� 138374 ARCHITECT OF RECORD� l J CONSULTANT ENGINEER� CONSULTANT� SEAL� VIEWER 0, � PER � � HARDWARE SCHED i > i i A B C REVISIONS: 03-09-2020 PERMIT SET � � �� iM ENO PANEL TO BE CUT TO MATCH HEIGHi OF WALL FlXiURE FIxiURE POSi S7RAPPING NOT TO E%iEN� BEYOND TOP OF FIkTURE - COORDINATE WIiH FlXTURE HEIGHTS ON FlNAL MERCHANDISE PLAN END PANEL BEYOND 1x3 WOOD SiRAPPING, FASIENED TO WALL FOR FlXIDRE SUPPORT w� 1 I 2" LONG SCRE w/ WASHERS (INSTALLED BY CONiRACTOR) rizTURE eASE EN� PANEL TO EH1EN� Y BEYON� Fl%IDRE BASE RELEA5E0 FOR CONSTRIlCTION Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��. — DATE: 06�QZ�2O � s � � � END PANEL TO BE CUT TO MATCH HEIGHT OF FIXNRE HEADER SIRAPPING NOT TO ERIEND BEYOND TOP OF FI%iURE SIDEWALL FIxNRE HEA�ER Ix3 WOOD SIRAPPING, FAS7ENE� TO WALL FOR Fl%iURE SUPPORT SCREWS w/LWASHERS QNSTALLED BY CONiRACiORJ FIXTURE POSi END PANEL BEYOND Ix3 W00� SIRAPPING, FASiENED i0 WALL FOR FlRNRE SUPPORT w/ 1 1/2' LONG SCREWS w/ WASHERS QNSiALLED BY coNmacTOR) FlXTURE BASE 0 � EN� PANEL TO E%IEN� 7' BEYON� FlXIURE BASE STRAPPING NOi TO E%TEN� BEYON� TOP oF rixTuac NORELL FIRNRE HEADER 1x3 W00� STRAPPING, FASiENED TO WALL FOR FIXTURE SUPPORT SCREWS w/LWASHERS QNSTALLE� BY CON7RACTOR) FIHIDRE POST END PANEL BEYOND ix3 WOOD SiRAPPING, FASTENE� TO WALL PoR FI%IURE SUPPORi SCREW.S w/LWASHERS QNSTALLE� BY CONTRACTOR) FI%NRE BASE EN� PANEL TO EXTEN� 2" BEYOND FI%Tl1RE BASE DRAWING BY: JAW CVS PROJECT MANAGER E ROSARIO DATE: 03-09-2020 JOB NUMBER: JCDT19.0401.00 TIT�E: DOOR SCHEDULE NOTES & DETAILS SHEET NUMBER: A7 COMMENTS: