Loading...
HomeMy WebLinkAboutED1-LIGHTING-PLAN---DEMOLITIONRELEA5E0 FOR CONSTRIlCTION Su6jec��o compliance with allregula�ions ofS�a�eantlLocalCodes �LAN City of Carmel r �un��\i lo•rvalM��. _ DATE: 06�QZ�2O � � — � \ � I _� ---� i�------------- GENERAL DEMOLITION NOTES 1. CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING CONDITIONS PRIOR TO Sl16MI5510N OF BID. NO ADDITIONAL COMPENSATION SHALL BE CONSIDERED PoR FAIWRE TO OBSERVE THIS REQIIIREMENT. 2 CONTRACTOR SHALL DISCONNECT AND REMOVE ALL ELECTRICAL WIRING AND EQUIPMENT AS REOUIRED WITHIN ALL AREAS TO BE RENOVATED. THIS SHALL INCWDE BUT NOT BE LIMITE� TO RXTURES, DEVICES, OUTLETS, SWITCHES, RECEPTACLES, STARTERS, DISCONNECTS, PANELS, FEE�ERS, ETC. 3. CONTRACTOR SHALL DISCONNECT AND REMOVE ALL EXISTING CIRCUITS TO MECHANICAL EQUIPMENT BEING REMOVED. REFER TO ALL MECHANICAL DEMOLITION DRAWINGS OR NOTES. 4. WHERE ELECTRICAL ITEMS ARE REMOVED, ALL BRANCH OEVICE'S WIRING SHALL BE REMOVED BACK TO PANEL SERVWG THE EQUIPMENT. WHERE CIRCUITS SERVE AD�ITIONAL DEVICES OR EQUIPMENT REMAINING, WIRING SHALL BE REMOVED BACK TO THE NEAREST ACTIVE JUNCTION BOX. 5. CONTRACTOR SHALL MAINTAIN CONTINUITY OF EXISTING QRCUITS THAT ARE TO REMAIN IN OPERATION AND SCHEDULE FOR REFEEDING FROM NEW PANELS. FORWARD FINDINGS TO ENGWEER FOR REVIEW AND COORDINATION. 6. ALL UNUSED CIRCUITS REMAINING AFTER REMOVALS SHALL BECOME SPARE IN PANELS, LABELED AS SPARE, AND SwITCHED TO THE OFF POSITION. 7. CONTRACTOR SHALL REFER TO ARCHITECTURAL DEMOLRION DRAWING FOR ADDITIONAL WFORMATION AND SCOPE OF DEMOLITION. 8. ALL MAiERIALS AND EQUIPMENT REMOVALS SHALL BE DISPOSED OF AS DIRECTED BY THE OWNER OR THE ARCHITECT. 9. ALL EMPTY WNDUITS MUST HAVE PULLWIRES AND BE TAGGED PROPERLY. 10. ELECiRICAL CONTRACTOR SHALL ilE BACK ALL LOOSE WIRWG QNCWDING LOW VOLTAGE) IN AN ORDERLY FASHION. 11. CONTRACTOR TO VERIFY ALL EXISTING CIRCUITS AND RELABEL PANEL SCHEDULES W FlELD AS REQUIRED. 12 CONTRACTOR TO VEPoFY ALL EXISTING PANEL LOADING M RELD AS RE�UIRED PRIOR TO ANY NEW WORK. CEILING DEMOLITION LEGEND ExisnNc cEiuNc I 1 I I ExisnNc acT TO 6E REMOV � I — � I-- -- I CEILING TO REMAIN CEILING FIXTURE SCHEDULE SYI.IBOL UESCRIPPON � 2X4 LIGHTS d SURFACE MWN7ED EMERGENCY 11GHT FlX7URE � SURFACE MWN7E� E%IT FIXNRE LIGiT � 1%4 LIGHTS � STRIP LIqiTS � WALLWASHER 11GHTS NO LABEL EWS7ING TO REMNN R E%IS71NG i0 RELOCAIE D E%IS71NG TO REMO�E - CAP h TAG NON-USE YARING Oj DISCONNECT AND RELOCATE EXISTING LIGHT FIXTURE. SEE SHEET E3 FOR PLACEMENT. ODISCONNECT AND REMOVE ERISTING LIGHT FIHTURE WITH ALL RELATED CABLING BACK TO NEAREST FIXTURE AND TERMINATE. MAINTAIN E%ISTING CIRCUIT AND REMAINING LIGHT FI%TURES. RETURN FI%TURE TO OWNER. �3 GC SHALL BE RESPONSIBLE TO MAINTAIN ALL AURILIARY SYSTEMS (ALARM, MUSIQ CAMERAS, ETG) IN AREAS OF CEIIJNG REMOVAL�REWORK IN�EPENDENTLY SUPPORT E�UIPMENT UNiIL CEILING WORK IS COMPLETE Af REWSTALL COORDINATE WITH CVS PM FOR PLACEMENT. O4 DISCONNECT AND RELOCATE LIGHT SWITCH TO ACCOMMODATE NEW RECEIVII DOOR. REFER TO SHEET E3 FOR NEW REPLACEMENT. � �� pharmacyry HUB/SSSI STORE NUI�BER 08674 1421 RANGELWE ROAD CARMEL, IN 46032 CAPCODE: (90/88) CS PRo,IECT NUA�6ER� 138374 ARCHITECT OF RECORD� C� CONSULTANT ENGINEER� CONSULTANT� SEAL� REVISIONS: 03-09-2020 DRAWING BY: CVS PROJECT MANAGER: DATE: JOB NUMBER: TITLE SHEET NUMBER: COMMENTS: PERMIT SET S. BEBA E ROSARIO 03-09-2020 JCDT19.0401.00 LIGHTING PLAN - DEMOLITION ED1