GENERAL DEMOLITION NOTES
1. CONTRACTOR SHALL VISIT THE SITE TO VERIFY EXISTING CONDITIONS PRIOR
TO Sl16MI5510N OF BID. NO ADDITIONAL COMPENSATION SHALL BE
CONSIDERED PoR FAIWRE TO OBSERVE THIS REQIIIREMENT.
2 CONTRACTOR SHALL DISCONNECT AND REMOVE ALL ELECTRICAL WIRING AND
EQUIPMENT AS REOUIRED WITHIN ALL AREAS TO BE RENOVATED. THIS SHALL
INCWDE BUT NOT BE LIMITE� TO RXTURES, DEVICES, OUTLETS, SWITCHES,
RECEPTACLES, STARTERS, DISCONNECTS, PANELS, FEE�ERS, ETC.
3. CONTRACTOR SHALL DISCONNECT AND REMOVE ALL EXISTING CIRCUITS TO
MECHANICAL EQUIPMENT BEING REMOVED. REFER TO ALL MECHANICAL
DEMOLITION DRAWINGS OR NOTES.
4. WHERE ELECTRICAL ITEMS ARE REMOVED, ALL BRANCH OEVICE'S WIRING
SHALL BE REMOVED BACK TO PANEL SERVWG THE EQUIPMENT. WHERE
CIRCUITS SERVE AD�ITIONAL DEVICES OR EQUIPMENT REMAINING, WIRING
SHALL BE REMOVED BACK TO THE NEAREST ACTIVE JUNCTION BOX.
5. CONTRACTOR SHALL MAINTAIN CONTINUITY OF EXISTING QRCUITS THAT ARE
TO REMAIN IN OPERATION AND SCHEDULE FOR REFEEDING FROM NEW
PANELS. FORWARD FINDINGS TO ENGWEER FOR REVIEW AND COORDINATION.
6. ALL UNUSED CIRCUITS REMAINING AFTER REMOVALS SHALL BECOME SPARE
IN PANELS, LABELED AS SPARE, AND SwITCHED TO THE OFF POSITION.
7. CONTRACTOR SHALL REFER TO ARCHITECTURAL DEMOLRION DRAWING FOR
ADDITIONAL WFORMATION AND SCOPE OF DEMOLITION.
8. ALL MAiERIALS AND EQUIPMENT REMOVALS SHALL BE DISPOSED OF AS
DIRECTED BY THE OWNER OR THE ARCHITECT.
9. ALL EMPTY WNDUITS MUST HAVE PULLWIRES AND BE TAGGED PROPERLY.
10. ELECiRICAL CONTRACTOR SHALL ilE BACK ALL LOOSE WIRWG QNCWDING
LOW VOLTAGE) IN AN ORDERLY FASHION.
11. CONTRACTOR TO VERIFY ALL EXISTING CIRCUITS AND RELABEL PANEL
SCHEDULES W FlELD AS REQUIRED.
12 CONTRACTOR TO VEPoFY ALL EXISTING PANEL LOADING M RELD AS
RE�UIRED PRIOR TO ANY NEW WORK.
CEILING DEMOLITION LEGEND
ExisnNc cEiuNc I 1 I I ExisnNc acT
TO 6E REMOV � I — � I-- -- I CEILING TO REMAIN
CEILING FIXTURE SCHEDULE
SYI.IBOL UESCRIPPON
� 2X4 LIGHTS
d SURFACE MWN7ED EMERGENCY 11GHT FlX7URE
� SURFACE MWN7E� E%IT FIXNRE LIGiT
� 1%4 LIGHTS
� STRIP LIqiTS
� WALLWASHER 11GHTS
NO LABEL EWS7ING TO REMNN
R E%IS71NG i0 RELOCAIE
D E%IS71NG TO REMO�E - CAP h TAG NON-USE YARING
Oj DISCONNECT AND RELOCATE EXISTING LIGHT FIXTURE. SEE SHEET E3 FOR
PLACEMENT.
ODISCONNECT AND REMOVE ERISTING LIGHT FIHTURE WITH ALL RELATED
CABLING BACK TO NEAREST FIXTURE AND TERMINATE. MAINTAIN E%ISTING
CIRCUIT AND REMAINING LIGHT FI%TURES. RETURN FI%TURE TO OWNER.
�3 GC SHALL BE RESPONSIBLE TO MAINTAIN ALL AURILIARY SYSTEMS (ALARM,
MUSIQ CAMERAS, ETG) IN AREAS OF CEIIJNG REMOVAL�REWORK
IN�EPENDENTLY SUPPORT E�UIPMENT UNiIL CEILING WORK IS COMPLETE Af
REWSTALL COORDINATE WITH CVS PM FOR PLACEMENT.
O4 DISCONNECT AND RELOCATE LIGHT SWITCH TO ACCOMMODATE NEW RECEIVII
DOOR. REFER TO SHEET E3 FOR NEW REPLACEMENT.
� ��
pharmacyry
HUB/SSSI
STORE NUI�BER 08674
1421 RANGELWE ROAD
CARMEL, IN 46032
CAPCODE: (90/88)
CS PRo,IECT NUA�6ER� 138374
ARCHITECT OF RECORD�
C�
CONSULTANT ENGINEER�
CONSULTANT�
SEAL�
REVISIONS:
03-09-2020
DRAWING BY:
CVS PROJECT MANAGER:
DATE:
JOB NUMBER:
TITLE
SHEET NUMBER:
COMMENTS:
PERMIT SET
S. BEBA
E ROSARIO
03-09-2020
JCDT19.0401.00
LIGHTING PLAN
- DEMOLITION
ED1