HomeMy WebLinkAboutHUB2-HEALTH-HUB-ENLARGED-CEILING-PLAN� iz,_4„ RHC1 im B_p� � � � � I � A � �� � ����� � <o ����� � � — �� TW I r._._— I� 1 10 r 1 �' 1 4,_0„ � - — — � �� II RHC 2 im 8._0. 1 � � , � � 1 � �� � • ' � CI � .1� O RELEA5E0 FOR CONSTRIICTI�N Su6jec��ocompliancewithallregula�ions PLI'1N of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��. DATE: 06�QZ�2O `_J 4,_0. � '::.�.::._�� ---- 'r.'.�r.'r.'r.'r. TYP '.':J:.':.':.':. O �:t?:�?:�?:�?: � °.� �i .:. :.:. ..':.'.'.'.'.':. ' z � ti 1 1 1 � � I� � � � � � I� RETAIL AREA —� O n'-s" 4 5 7 8 I � J UNISTRUT SUPPORTS ATfACHE� TO JOISTS; UNISTRUT TO BE PURCHASED IF NOT SUPPLIED, RE STRUCTURAL AIRCRAFT CABLE Kli PROVIDED BY MILLER ZELL TO BE CRINPED OR WRAPPED PROVIDE 1" HOLE IN T-BAR CEILING AIRCRAFT CABLE KIT PROVIDED BY MILLER ZELL EYEBOLT FOR SUSPENSION (NOT DIRECTLY OVER BEAMS) siNc�c: DROP IN BEAIAS HANGERS 3°X3" PURLIN RETAIL CEILING HEIGH�T ELEV = 11' -5" NOTES 1. INSiALL NEW/RELOCATE POWER POLES. PRON�E A��IPONAL SHEET METAL, F�% REFERENCE ELEC7RICAL DWGS. �UCT, HANGERS AN� ACCESS7RIES AS 2 EXISIING PERIMEIER 9GNAGE TO BE REOUIRE� TO RELOCATE AIR IERMINAL CONSISiENT WiH CURRENT CVS SiAN�ARDS. �ENCES. HVAC AIR IERMINAL �EWCES TO BE GC AND CVS CPA1 TO COORDINAiE DEMO, MO�IFlE� SHALL CONFORM TO SMACNA RELOCAiION, AND�OR RE-USE OF ALL STAN�AR�S. UPON PROJECT COMPLEiION, AIR EXISIING GRAPHICS. IERMINAL DEVICES AND MININUM 5 OF 3. RELOCA➢ON OF E%ISiINC SEWRRY CAMERAS, ASSOCIAiED BRANCH �l1CTWORK SHALL BE MO110N DETECTORS, AND SECURITY CLEANE� FREE OF D115T AND DEBRIS. EQUIPMENi BY CVS VENDOR. GC SHALL �ODIFlCAiION i0 EXISPNG VENTILATION AIR COORDINAiE INSTALLAlION W11H VENDOR. FLOW SHALL NOi 6E PERMITfE�. 4. REPLACE ANY SiAMED OR DAMAGED CEILING 9� GC SHAl1 RELOCATE SPRINKLER HEADS AS TIIE 1HROUGHOUT ENiIRE STORE AS REOUIRED TO FACILITATE CEILING GRID DEiERMMED DURING PRE-BID WALKhiROUGH. MODIFICAilONS AND/OR RELOCAiION OF 5. REPAIR OR REPLACE ANY DAMAGED OR LIGHT FI%iURES. PROVIDE ADDIiIONAL PIPING, INOPERABLE LIGHT Fl%iURES AS REQUIRED. HANGERS, AND AWESSOPoES AS REOUIRED 6. RELO�INSTALL NEW AISLE MARKERS PER CVS TO FAqLRAiE SPRINKLER PIPING SET-UP MANAGER. MODIFICAilONS. FIRE PROiECiION SPRINKLER 7. CLEAN ALL EXISPNG HVAC �IFFUSERS AND SYSiEM MODIFICAilONS SHALL CONFORN TO LIGHT FIRNRE LENSES 1HROUGHOUT THE NFPA 13 WSTALLAiION AND OPERAiION EN11RE STORE. SiANDAR�S. FIRE SUPPRESSION SYSTEM 8. GENERAL CONIRACTOR SHALL COOR�INAIE DRAWINGS SHALL BE PREPARED BY A RENSE� CEILING GRID AND LIGHIING FIkTURE LICENSED FIRE PROiECiION CONiRACiOR AS LOCATIONS W11H ERISIING CEILING DIFFUSERS REOUIRED BY THE AUiHORlilES HAVING AN� REGISTERS. GC SHALL RELOCAIE JURISDICiION. �IFFUSERS AN� REGISTERS AS REQUIRED TO FACILIiAIE CEILING GRI� MO�IFICAlI0N5 nNo/oR RE�ocnnoN oF ucHT FlZNREs. LEGEND T.O. TRELL�IS ELEV =11'-2�' BEAM 2" BIN�ER POSTS EXISTING PAR➢➢ON TO REMAIN +-� > �:+jq;y".� NEW GIPSUM WALLBOAR� CEILING NEW PARTITION `t'�"�" �. NEW ACOUSTICAL CEILING ➢LE ^O KEY NOIE �ESIGNATION ;� AND CEILING GRID E%ISTING ACOUSPCAL CEILING TILE A TO REMAIN � COWMN GRID FlXTURE DE9GNATIONS ��� EXISPNG CEILING J06T TO E E%ISiING TO REMAIN REMAIN N NEW ��� NEW CEILING J015T RE RELOCATE FOLLOW 9�-10° AWAY FROM FINISH F�ooR cnoENCE Ta nucN w�N AISLE MARKERS, UNLESS 18" MINIIAUM RE�UIREIAENT FROM BOTfOM OF TREws ro cEwNc is Nor snnsFiEo. RE STRUC7URAL SHEET S2 � b i � Ns � - � B_0. TRELLI$ h E�Ev = s'-io' v 3 SUSPENSION AT PERLIN SECTION HU62 a' = r-o" cnNOPr FEEo ro TRACK ���� io'-o" �TRACK LIGHT FIXNRE (TIPICAL OF 9) RE: ELEC7RICAL — — — — — � — CEILING PICK POINTS. �� ��� — � � � F C_ J _____ _____ J L_ J auN wiRc nNo coNouir FROM oNc macK J J L J CONNECTOR TO 7HE NEXT BY RUNNWG ALONG _ Q I TOP SIDE OF PERLINS. _ I I I I I i— I I YARE AN� CON�UIT SHALL BE NEATLY INSTALLED TO BE OUT OF THE V1EW OF 7HE PUBLIC. N � �-�,�-----��-----�'�-� I 3 I�/ I�I IT�/ I I TRACK CONNECTOR HUB2 M � (TIPICAL OF 3) �_� �----_��__===��k= � — — ��� — _ I � � �_J L-===-�L-----J�L_� I �� �� � � r I SINGLE CIRCUIT iRACK I I I I I� I I I (TYPICAL OF 3) RE: ELEC '��-� �-----��-----�iK-� k�, I•I ,k�, I �-�---- �� �+� � I � C � � � � ��� � � � I I HOLES ARE PRE-�RILLED 7HROUGH W000 (NOT _ LAMINAIE) FOR IJGH7S. HOWEVER, LIGHTS MAY � C — � � — _ — — — — — — — — � � — I MOVE FROM PREDRILLE� HOLES. ��\ I°I (�e \ I I FIELD AN� CANOBEnATfACHED TO 7HEIPERLINS ns NCEOEo. � � _ �_ _ _ _ _ �_ _ _ _ _ �_ � ELEC7RICAL CONTRACTOR TO INSTALL 7RACN I I I I LIGHTS. �. 5. 2 ENLARGED TRELLIS PLAN VIEW HU62 3/a° = i'-o' Y 2" ,._5. CEILING FIXTURE SCHEDULE cxisnNc/ocMo/ncw sn�eo� ocscRiPnoN � � � 1 �O 7x4 IJGHTS L�J - [�] � 1x41JGHTS . . . MONOPOIM LIGHTS ��- �� s,��P ��rs . � �—� �� smiP uvwrs A' � 1A( �( B( �Q EXIT SIGNS �� t � D o a EMERGENCYIJGHTS = • • POWER DROP z ■ e POWER POLE _" '�' OO SPEAKER Q �y � SECURITY CAMERA BUBBLE /•� /•� n SECURITY MOTION $ENSOR L � f�% SPRINKLER HEAD � � � �� � HVAC SUPPLY � r� � HVAC REIDRN ICJ � � � HVAC EXHAUST CEILING NEW NOTES BY SYMBOL O1 INSTALL NEW�RELOCATED LIGHT FIXIDRES Og INSTALL NEW TRELLIS, CEN7ERED W17HIN AS SHOWN/SCHE�ULED. RE ELEC7RICAL RHC WAIiING. RE 2/HUB2 O AS SHOWN/SCHEDULEDC REGELECTRICALS � RE'TELECTR CARACK LIGHTING AS SHOWN. O3 WSTALL NEW ACi GRID, HANGERS, AND �� SYS7EM AS SHOWN RE:MECHANICALIT ALL NEW ACT TIES AS SHOWN/ SCHEDULED. Oq GC TO COORDINATE WITH CVS VENDOR 12 SHOWNLREMECH�A ICAL & 6/p71NG AS FOR RELOCAPON/INSPLLATION OF ALL SECURITY EOUIPMENT,INCWDING �3 INSTALL NEW/RELOCATED CAA�ERAS AN� MOPON DEIECTORS. SUPPLY�RETURN DIFFUSERS AS SHOWN RE:MECHANICAL O GC SHALL COOR�INATE FIRE ALARM SYS7EM MODIFlCATIONS lM7H 7HE CVS VENDOR AND RELOCATE EXIS7ING STROBES AS REQUIRE�. O iNSTa�� NEw PowER oRoa ns sHowN. RE ELECIRICAL O7 GC TO PURCHASE AND INSTALL (3) CASES OF CEILING TILES AS SCHEDULED TO REPLACE DAMAGED/STAINED 71LE5 THROUCHOUT. Og CLEAN E%IS➢NG HVAC DIFFUSERS �'�� pharmacy" HUBISSSI STORE NUMB6� 08674 1421 RANGELWE ROAD CARMEL, IN 46032 CAPCODE: (90/88) CS PROJECT NUMBER 138374 I ARCHITECT OF RECORD� � CONSULTANT ENGINEER� CONSULTANT� SEAL� REVISIONS: 03-09-2020 PERMIT SET DRAWING BY: JAW CVS PROJECT MANAGER E ROSARIO DATE: 03-09-2020 JOB NUMBER: JCDT19.0401.00 TIT�E: HEALTH HUB ENLARGED CEILING PLAN SHEET NUMBER: HUB2 COMMENTS: