HomeMy WebLinkAboutM3-MECHANICAL-SCHEDULES-AND-DETAILSGRILLE, REGISTER, DIFFUSER SCHEDULE
TAG SERVICE CFM NECK FRAME pqTTERN DAMPER MAIERIAL FINISH MANOFACTURER & MODEL
SIZE TYPE N0.
RG-1 RETURN SEE PLANS SEE NOiE 1,2 NONE NO STEEL OFF—WHITE METALAIRE CC1 CUBE
PLANS CORE RET./EXHAUST
NOIE: 1. MOOEL NUMBERS ARE METALAIRE UNLESS O7HERWISE NOIED.
2 PROVIDE TRANSITION TO �IFFUSER WHERE REOUIRE�.
INSULATED RIGID
METAL DUCT
AND ELBOW
cM�N�
DRAW—BAND CLAMP —
TYPICAL EACH END
SPIN—IN
INSULATED
FLEX DUCT MAX OFFSET ALLOWABLE:
�2—INCHES PER FOOT OF
REXIBLE DUCT LENGTH
SEISMIC INSULATE TOP OF DIFFUSER (MAY
RESTRAINT. BE OMITTED WHERE CEILING
MIN. 2 ON CAVITY IS USED AS A RETURN
OPPOSITE �L AIR PLENUM — TYPICAL
CORNE45.
��CEILING AIR �EVICE — CBLING
TYPICAL
LONG RUN, SIDE TAP INSTALLATION
INSULATED SUPPLY AIR
TRUNK DUCT — REFER
TO PLAN
INSULATED SPIN—IN
FITTING WITH MANUAL
DAMPER AND ACCESSIBLE
INDICATING HANDLE —
TYPICAL
GRILLE CONNECTION DETAIL NOTES
1. TWO INSTALLATION OPTIONS ARE SHOWN. PROVIDE 7HE MOST SUITABLE
OPTION BASE� UPON ACIDAL DUCT LAYOUT, �IFFUSER LOCATION, AN� FlELD
CONOITIONS. WHERE FLEXIBLE Dl1CT RUN EXCEEOS THE MAXIMUM ALLOWABLE
LENGTH, PROVIOE THE LONG RUN, SIDE TAP INSTALLATION.
2 FLEXIBLE Dl1CT: LLL LIS7ED CLASS 1 AIR DUCT, TESTE� IN ACCORDANCE
WITH LLL 181. MAXIMUM LENGTH ALLOWED IS 5 FEET.
3. SPIN—W FITTWG FLARED TYPE WITH BUT7ERFLY �AMPER AND INDICATING
HANDLE. PROVI�E STRAIGHT—IN TYPE SPIN—W FITTING ONLY WHERE 7RUNK
DUCT SIZE WILL NOT ALLOW THE INSTALLATION OF A FLARE� TWE FITTING.
INSTALL DUCT MSULAPON SO THAT DAMPER HANDLE IS ACCESSIBLE AND
VISIBLE ON THE BOTTOM OR SI�E OF THE SPIN—M RTPNG.
4. PROVIDE ACCESS TO �AMPERS LOCATEO IN CEILWGS O7HER THAN LAY—IN
TYPE CEIIJNGS.
5. PROVIDE MINIMUM LENG7H OF FLEXIBLE DUCT WITH NO EHCESS LENGTH
BE7INEEN CONNECTION POINTS. INSTALL FULLY EH7ENDED, NOT COMPRESSE�.
6. EXTEN� FLEXIBLE Dl1CT A MINIMUM LENG7H OF ONE �UCT DIAMETER
STRAIGHT FROM CONNECTION POINTS BEFORE BEN�ING. MAKE SMOO7H
BENDS WI7HOUT OEFORMING �UCT CROSS—SECTION.
7. PROVIDE ROUN�—TO—RECTANGULAR INSULAIED SHEET METAL 7RANSITION AT
THE NECK OF 7HE CEILING AIR �EVICE AS NECESSARY FOR RECTANGOLAR
NECK DIFFUSERS/GRILLES.
B- SUPPORT RE%IBLE DUCi AS RECOMMENDED BY MANUFACTURER USING A
MINIMUM OF 1-1/2 INCH WI�E BAND CLAMP. MAXIMUM HANGER SPACING IS
4 FEET WITH A MAXIIAUM PERMISSIBLE SAG OF 1/2—INCH PER FOOT
BE7INEEN SUPPORTS. HANGERS MUST MAINTAIN ROUN� �UCT SHAPE.
LEGEND
TO AHU REMOIE CONTROLLER
EIAS SENSOR: EMERSON CLIMAIE TECH SOWPONS.
Q CONiACi�, (800) 829-2724
� SUPPLY AIR DIFFUSERS:
(METALAIRE SERIES 5500 FIN6H OFF—WHI7E.
PROVIDE FRAME SUITABLE PoR LAY—IN CEIIJNG)
� RENRN AIR DIFFUSERS:
(METALAIRE SERIES CC1 FINISH OFF—WHITE
PROVIDE FRAME SUITABLE FOR LAY—IN CEILING)
lO NOTES BY SYIABOL
CFM CUBIC FEET NK NECK
PER MINUIE AFF ABOVE FIMSHED
DN. DOWN FLOOR
CD CONDENSAI- I]anW E%H. E%HAUsi
SA SUPPLY AIR REQ'D REOl11RED
RA REiURN AIR DMPR DAMP_R
FD FlRE �AMPER
GENERAL NOTES
L GENERAL NOIES ARE APPLICABLE TO ALL HVAC
DRAWINGS.
2 PERFORM WORK IN ACCOROANCE WITH THE LATEST
EOITIONS, REVISIONS, AMEN�MENTS, OR SUPPLEMENTS
OF APPLICABLE STATUTES, OR�INANCES, CO�ES OR
REGULATIONS OF FE�ERAL, STATE, AND LOCAL
AUTHORITIES HAVING JURISDICTION M EFFECT ON 1HE
DATE BI�S ARE RECEIVED.
3. WHERE APPROVE� STANDAR�S HAVE BEEN
ESTABLISHED BY OSHA, UN�ERWRITERS LABORATORIE$
AMERICAN CODES, ASA, ASHRAE, ARI, NEQ STATE FIRE
INSURANCE REGULATION BO�Y, NFPA OR OTHERS.
THESE STANDARDS SHALL BE FOLLOWEO WHETHER OR
Nor woicnTEo oN THE oRnvnNc nNo sPcciricanoNs.
4. ALL DUCT i0 BE OF 2" PRESSURE CLASS, UNLESS
NOTE� O7HERWISE.
5. LIGHT FlXTURE LOCATIONS TAKE PRECE�ENCE OVER
DIFFOSER AND GRILLE LOCATIONS. LOCAIE �IFFOSERS
AND GRILLES TO ACCOMMODAIE LIGHTING LAYOUT.
6. DUCT S2E5 SHOWN ARE NET FREE AREA.
7. DUC7WORK SHALL NOT BE SUPPORTE� FROM BRIDGING.
DO NOi USE FAS7ENER5 7HAT PENETRATE ROOF �ECN.
8. REFER i0 DETAIL 1/M} FOR DIFFUSER/GRILLE
WSTALLATION.
9. CVS/PHARMACY HAS EN7ERED INTO A NATIONAL
ACCOUNT AGREEMENT WI1H CPC FOR FURNISHING THE
ENERGY MANAGEMENT SYSTEM. FOR FURTHER
WFORMATION, CALL CPC AT (80�J 829-2724.
INSTALLATION OF SENSORS BY 7HE EMS CON7RACTOR.
INSULATED _ DRAW—BAND CLAMP —
FLEX DUCT
TYPICAL EACH EN�
SEISMIC RESTRAINT.
MIN. 2 ON OPPOSITE
CORNERS.
MAX OFFSET ALLOWABLE:
2—INCHES PER FOOT OF
FLEXIBLE DUCT LENGTH
BOTTOM TAP INSTALLATION
CEILING DIFFUSER/RETURN
i GRILLE CONNECTION DETAIL
M3 NOT TO SCALE
2"X2,�X� �8"
6• ANGLE OR
UNISTRUT
TWO SHEET METAL
SELF TAPPING
SCREWS
ROUND
DUCTWORK
DUCT SUPPORT PARALLEL TO TRUSSES
TWO SHE
SELF TAF
SCREWS
ROUND
DUCTWOF
NOTES:
1. ALL DUCT & SUPPORTS PER UMC.
ROOF
JOIST
fi" .
MAIN SUPPLY �UCT
OR SUB—MAIN
RECTANGULAR
DUCTWORK
�� DUCT HANGER DETAIL
M3 NOT TO SCALE
�� BRANCH TAKE—OFF DETAILS
M3 NOT TO SCALE
MAW SUPPLY
DUCT (OR
SUB—MAIN)
RECTANGULAR
TO ROUND SIDE
DUCT
TAKE—OFF
18 GAUGE
VOLUME
DAMPER WITH
LOCKING
QUADRANT SET
(TYP. FOR ALL
SUPPLY/RETURN/
EXHAUST AIR
BRANCH DUCT)
NOTES:
L COORDINATE ALTERNATIVE ELECTRICAL VOLTAGE AND WIRING/BREAKER REQUIREMENTS WITH ELECTRICAL CONTRACTOR.INSTALL PER
UANUFACTURERS INSTRUCilONS COMPLETE WIiH REFRIGERANT PIPING, FULL REFRIGERANT CHARGE AND PROPER STARTUP PROCEDURES.
2. PROVIDE CONDENSATE DRAIN PUMP WITH SINGLE POINT POWER CONNECTION TO AHU. PROVIDE CONDENSATE DRAIN PAN AND DRAIN UND=R THE
UNIT COIL PROVI�E DRAW LEVEL SWITCH (DPLS1�, CONNECTE� TO CONTROL PANEL, TO PREVENT CONDENSATE FROM OVERFLOWING.
3. SLP-15AAUW GRILLE ASSEMBLY.
4. PAC—YT53CRAU SIMPLE MA CONTROLLER.
5. MAC-3331F—E M—NET ADAPTOR.
6. USE SOLI� COPPER CONDUCTOR MIN. AWG14 FROM CU-1 TO EACH AHU.
7. USE SOLID COPPER CONDUCTOR MIN. AWG8 TO POWER THE CONDENSING UNIT.
8. PROVIDE ULTRA LIGHT CONDENSING UNIT PAD ON ROOF.
�c�
pharmacyry
HUBISSSI
sro� NUMeea 08674
1421 RANGELME ROAD
CARMEL, IN 46032
GAPCODE: (90�88�
CS PROJECT NUMBER 138374 I
ARCHITECT OF RECORD�
ri
LI
CONSULTANT ENGINEER�
CONSULTANT�
SEAL�
REVISIONS:
03-09-2020 PERMIT SET
DRAWING BY: M. MIZWA
CVS PROJECT MANAGER: E. ROSARIO
DATE 03-09-2020
JOB NUMBER: JCDT19.0401.0(
TI TLE
MECHANICAL SCHEDULES
AND DEfAILS
RELEA5E0 FOR CONSTRIICTI�N
Su6jec��o compliance with allregula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM��_
DATE: 06�QZ�2O
MINI SPLIT SYSTEM SCHEDULE
AIRFLOW ELECTRICAL
TAG MANUFACTURER MODEL NUTABER CFM MCA MOCP EER�SEER FSPF REMARKS
LOW�MED�HIGH VOLi/PHASE
AHU—� PANASONIC CS—E12RB4UW 260/310/370 208/1/60 02J --- --- -- 1,2,3,4,5
CU-1 PANASONIC CU—E12RB4U -- 208/1/60 12 15 10.3/18.0 9.0 1,6,7
1/4 W. q
MIN.
BRANCH
PROVIDE VOLUME
DAMPER (OBMW)
SUPPLY AIR DUCT
r VOLUME DAMPER
I
I 11
I
CONICAL TAP � ROUND
BRANCH
MAM SUPPLY
DUCT (OR
SUB—MAIN)
THE DRAWINGS AND SPEQFlCATIONS ARE PRODUCED REPRESENTING
WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL,
STATE AND LOCAL CODES. THE LOCAL CODE AUTHORITY HAS THE
AUTHORITY TO INTERPRET CODE REQUIREMENTS IN THEIR JURISDICTION.
THESE INTERPRETATIONS MAY VARY FROM WFORMATION PRESENTED IN
THE DOCUMENTS. THE CONTRACTOR SHALLINFORM THE OWNER'S
REPRESENTATNE AND THE ARCHITECT—ENGINEEER, OF RECORD, OF
THE DIFFERENCES AND SHA_L PROCEED WIT— THE WORK UPON
FECEVNG 'HEIR AGREEME�T WI—H T—E LOCAL CODE AUTHORITY
INTERPRETATION.
SHEET NUMBER:
M3
COMMEVTS
DUCT SUPPORT PERPENDICULAF TO TRUSSES