HomeMy WebLinkAboutM3-MECHANICAL-SCHEDULES-AND-DETAILSGRILLE, REGISTER, DIFFUSER SCHEDULE TAG SERVICE CFM NECK FRAME pqTTERN DAMPER MAIERIAL FINISH MANOFACTURER & MODEL SIZE TYPE N0. RG-1 RETURN SEE PLANS SEE NOiE 1,2 NONE NO STEEL OFF—WHITE METALAIRE CC1 CUBE PLANS CORE RET./EXHAUST NOIE: 1. MOOEL NUMBERS ARE METALAIRE UNLESS O7HERWISE NOIED. 2 PROVIDE TRANSITION TO �IFFUSER WHERE REOUIRE�. INSULATED RIGID METAL DUCT AND ELBOW cM�N� DRAW—BAND CLAMP — TYPICAL EACH END SPIN—IN INSULATED FLEX DUCT MAX OFFSET ALLOWABLE: �2—INCHES PER FOOT OF REXIBLE DUCT LENGTH SEISMIC INSULATE TOP OF DIFFUSER (MAY RESTRAINT. BE OMITTED WHERE CEILING MIN. 2 ON CAVITY IS USED AS A RETURN OPPOSITE �L AIR PLENUM — TYPICAL CORNE45. ��CEILING AIR �EVICE — CBLING TYPICAL LONG RUN, SIDE TAP INSTALLATION INSULATED SUPPLY AIR TRUNK DUCT — REFER TO PLAN INSULATED SPIN—IN FITTING WITH MANUAL DAMPER AND ACCESSIBLE INDICATING HANDLE — TYPICAL GRILLE CONNECTION DETAIL NOTES 1. TWO INSTALLATION OPTIONS ARE SHOWN. PROVIDE 7HE MOST SUITABLE OPTION BASE� UPON ACIDAL DUCT LAYOUT, �IFFUSER LOCATION, AN� FlELD CONOITIONS. WHERE FLEXIBLE Dl1CT RUN EXCEEOS THE MAXIMUM ALLOWABLE LENGTH, PROVIOE THE LONG RUN, SIDE TAP INSTALLATION. 2 FLEXIBLE Dl1CT: LLL LIS7ED CLASS 1 AIR DUCT, TESTE� IN ACCORDANCE WITH LLL 181. MAXIMUM LENGTH ALLOWED IS 5 FEET. 3. SPIN—W FITTWG FLARED TYPE WITH BUT7ERFLY �AMPER AND INDICATING HANDLE. PROVI�E STRAIGHT—IN TYPE SPIN—W FITTING ONLY WHERE 7RUNK DUCT SIZE WILL NOT ALLOW THE INSTALLATION OF A FLARE� TWE FITTING. INSTALL DUCT MSULAPON SO THAT DAMPER HANDLE IS ACCESSIBLE AND VISIBLE ON THE BOTTOM OR SI�E OF THE SPIN—M RTPNG. 4. PROVIDE ACCESS TO �AMPERS LOCATEO IN CEILWGS O7HER THAN LAY—IN TYPE CEIIJNGS. 5. PROVIDE MINIMUM LENG7H OF FLEXIBLE DUCT WITH NO EHCESS LENGTH BE7INEEN CONNECTION POINTS. INSTALL FULLY EH7ENDED, NOT COMPRESSE�. 6. EXTEN� FLEXIBLE Dl1CT A MINIMUM LENG7H OF ONE �UCT DIAMETER STRAIGHT FROM CONNECTION POINTS BEFORE BEN�ING. MAKE SMOO7H BENDS WI7HOUT OEFORMING �UCT CROSS—SECTION. 7. PROVIDE ROUN�—TO—RECTANGULAR INSULAIED SHEET METAL 7RANSITION AT THE NECK OF 7HE CEILING AIR �EVICE AS NECESSARY FOR RECTANGOLAR NECK DIFFUSERS/GRILLES. B- SUPPORT RE%IBLE DUCi AS RECOMMENDED BY MANUFACTURER USING A MINIMUM OF 1-1/2 INCH WI�E BAND CLAMP. MAXIMUM HANGER SPACING IS 4 FEET WITH A MAXIIAUM PERMISSIBLE SAG OF 1/2—INCH PER FOOT BE7INEEN SUPPORTS. HANGERS MUST MAINTAIN ROUN� �UCT SHAPE. LEGEND TO AHU REMOIE CONTROLLER EIAS SENSOR: EMERSON CLIMAIE TECH SOWPONS. Q CONiACi�, (800) 829-2724 � SUPPLY AIR DIFFUSERS: (METALAIRE SERIES 5500 FIN6H OFF—WHI7E. PROVIDE FRAME SUITABLE PoR LAY—IN CEIIJNG) � RENRN AIR DIFFUSERS: (METALAIRE SERIES CC1 FINISH OFF—WHITE PROVIDE FRAME SUITABLE FOR LAY—IN CEILING) lO NOTES BY SYIABOL CFM CUBIC FEET NK NECK PER MINUIE AFF ABOVE FIMSHED DN. DOWN FLOOR CD CONDENSAI- I]anW E%H. E%HAUsi SA SUPPLY AIR REQ'D REOl11RED RA REiURN AIR DMPR DAMP_R FD FlRE �AMPER GENERAL NOTES L GENERAL NOIES ARE APPLICABLE TO ALL HVAC DRAWINGS. 2 PERFORM WORK IN ACCOROANCE WITH THE LATEST EOITIONS, REVISIONS, AMEN�MENTS, OR SUPPLEMENTS OF APPLICABLE STATUTES, OR�INANCES, CO�ES OR REGULATIONS OF FE�ERAL, STATE, AND LOCAL AUTHORITIES HAVING JURISDICTION M EFFECT ON 1HE DATE BI�S ARE RECEIVED. 3. WHERE APPROVE� STANDAR�S HAVE BEEN ESTABLISHED BY OSHA, UN�ERWRITERS LABORATORIE$ AMERICAN CODES, ASA, ASHRAE, ARI, NEQ STATE FIRE INSURANCE REGULATION BO�Y, NFPA OR OTHERS. THESE STANDARDS SHALL BE FOLLOWEO WHETHER OR Nor woicnTEo oN THE oRnvnNc nNo sPcciricanoNs. 4. ALL DUCT i0 BE OF 2" PRESSURE CLASS, UNLESS NOTE� O7HERWISE. 5. LIGHT FlXTURE LOCATIONS TAKE PRECE�ENCE OVER DIFFOSER AND GRILLE LOCATIONS. LOCAIE �IFFOSERS AND GRILLES TO ACCOMMODAIE LIGHTING LAYOUT. 6. DUCT S2E5 SHOWN ARE NET FREE AREA. 7. DUC7WORK SHALL NOT BE SUPPORTE� FROM BRIDGING. DO NOi USE FAS7ENER5 7HAT PENETRATE ROOF �ECN. 8. REFER i0 DETAIL 1/M} FOR DIFFUSER/GRILLE WSTALLATION. 9. CVS/PHARMACY HAS EN7ERED INTO A NATIONAL ACCOUNT AGREEMENT WI1H CPC FOR FURNISHING THE ENERGY MANAGEMENT SYSTEM. FOR FURTHER WFORMATION, CALL CPC AT (80�J 829-2724. INSTALLATION OF SENSORS BY 7HE EMS CON7RACTOR. INSULATED _ DRAW—BAND CLAMP — FLEX DUCT TYPICAL EACH EN� SEISMIC RESTRAINT. MIN. 2 ON OPPOSITE CORNERS. MAX OFFSET ALLOWABLE: 2—INCHES PER FOOT OF FLEXIBLE DUCT LENGTH BOTTOM TAP INSTALLATION CEILING DIFFUSER/RETURN i GRILLE CONNECTION DETAIL M3 NOT TO SCALE 2"X2,�X� �8" 6• ANGLE OR UNISTRUT TWO SHEET METAL SELF TAPPING SCREWS ROUND DUCTWORK DUCT SUPPORT PARALLEL TO TRUSSES TWO SHE SELF TAF SCREWS ROUND DUCTWOF NOTES: 1. ALL DUCT & SUPPORTS PER UMC. ROOF JOIST fi" . MAIN SUPPLY �UCT OR SUB—MAIN RECTANGULAR DUCTWORK �� DUCT HANGER DETAIL M3 NOT TO SCALE �� BRANCH TAKE—OFF DETAILS M3 NOT TO SCALE MAW SUPPLY DUCT (OR SUB—MAIN) RECTANGULAR TO ROUND SIDE DUCT TAKE—OFF 18 GAUGE VOLUME DAMPER WITH LOCKING QUADRANT SET (TYP. FOR ALL SUPPLY/RETURN/ EXHAUST AIR BRANCH DUCT) NOTES: L COORDINATE ALTERNATIVE ELECTRICAL VOLTAGE AND WIRING/BREAKER REQUIREMENTS WITH ELECTRICAL CONTRACTOR.INSTALL PER UANUFACTURERS INSTRUCilONS COMPLETE WIiH REFRIGERANT PIPING, FULL REFRIGERANT CHARGE AND PROPER STARTUP PROCEDURES. 2. PROVIDE CONDENSATE DRAIN PUMP WITH SINGLE POINT POWER CONNECTION TO AHU. PROVIDE CONDENSATE DRAIN PAN AND DRAIN UND=R THE UNIT COIL PROVI�E DRAW LEVEL SWITCH (DPLS1�, CONNECTE� TO CONTROL PANEL, TO PREVENT CONDENSATE FROM OVERFLOWING. 3. SLP-15AAUW GRILLE ASSEMBLY. 4. PAC—YT53CRAU SIMPLE MA CONTROLLER. 5. MAC-3331F—E M—NET ADAPTOR. 6. USE SOLI� COPPER CONDUCTOR MIN. AWG14 FROM CU-1 TO EACH AHU. 7. USE SOLID COPPER CONDUCTOR MIN. AWG8 TO POWER THE CONDENSING UNIT. 8. PROVIDE ULTRA LIGHT CONDENSING UNIT PAD ON ROOF. �c� pharmacyry HUBISSSI sro� NUMeea 08674 1421 RANGELME ROAD CARMEL, IN 46032 GAPCODE: (90�88� CS PROJECT NUMBER 138374 I ARCHITECT OF RECORD� ri LI CONSULTANT ENGINEER� CONSULTANT� SEAL� REVISIONS: 03-09-2020 PERMIT SET DRAWING BY: M. MIZWA CVS PROJECT MANAGER: E. ROSARIO DATE 03-09-2020 JOB NUMBER: JCDT19.0401.0( TI TLE MECHANICAL SCHEDULES AND DEfAILS RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: 06�QZ�2O MINI SPLIT SYSTEM SCHEDULE AIRFLOW ELECTRICAL TAG MANUFACTURER MODEL NUTABER CFM MCA MOCP EER�SEER FSPF REMARKS LOW�MED�HIGH VOLi/PHASE AHU—� PANASONIC CS—E12RB4UW 260/310/370 208/1/60 02J --- --- -- 1,2,3,4,5 CU-1 PANASONIC CU—E12RB4U -- 208/1/60 12 15 10.3/18.0 9.0 1,6,7 1/4 W. q MIN. BRANCH PROVIDE VOLUME DAMPER (OBMW) SUPPLY AIR DUCT r VOLUME DAMPER I I 11 I CONICAL TAP � ROUND BRANCH MAM SUPPLY DUCT (OR SUB—MAIN) THE DRAWINGS AND SPEQFlCATIONS ARE PRODUCED REPRESENTING WORK TO BE DONE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. THE LOCAL CODE AUTHORITY HAS THE AUTHORITY TO INTERPRET CODE REQUIREMENTS IN THEIR JURISDICTION. THESE INTERPRETATIONS MAY VARY FROM WFORMATION PRESENTED IN THE DOCUMENTS. THE CONTRACTOR SHALLINFORM THE OWNER'S REPRESENTATNE AND THE ARCHITECT—ENGINEEER, OF RECORD, OF THE DIFFERENCES AND SHA_L PROCEED WIT— THE WORK UPON FECEVNG 'HEIR AGREEME�T WI—H T—E LOCAL CODE AUTHORITY INTERPRETATION. SHEET NUMBER: M3 COMMEVTS DUCT SUPPORT PERPENDICULAF TO TRUSSES