HomeMy WebLinkAbout16 SITE DETAILSMAY 20, 20208
AB3456712CDEFGH83456712ABCDEFGHDESCRIPTIONDATENO
REVISION RECORD
DATE:
DWG SCALE:
DRAWN BY:
CHECKED BY:
APPROVED BY:
PROJECT NO:SHEETOFDRAWING NO.:STUDIO M ARCHITECTURE
L'ETOILE
833 W. MAIN STREET
CARMEL, INDIANA 530 E. Ohio Street · Suite G - Indianapolis, IN 46204
317-655-7777 · 877-746-0749
www.cecinc.comPERMITNOT FORCONSTRUCTIONPENDING21192-773NOT TO SCALEDETAIL 500 - CLEANOUT DETAILMAXIMUM CLEANOUT SPACINGTO BE NO MORE THAN 100 FEET.FLEXIBLE PIPESLEEVE4' MIN. SEEUTILITY PLANFOR INVERTSFINISH FLOOR3'- 0" MAX.6"(TYP)CONCRETE COLLARHEAVY DUTY LAMPHOLECASTING W/ SOLID LID,NEENAH R-1974 OR EQUALCOMPACTED SOIL BACKFILL#8 COMPACTED STONEWYE45° BEND6"
TOPSOIL
NOTE:O.D. + 1'-0"Min. (Typ.)CONCRETE COLLARCONC. COLLARFLEXIBLE COUPLINGOR ADAPTOROR ADAPTORDUCTILE IRON PIPECLASS 150 MECH. JOINTMIN.WATER MAIN10'10'18"WATER MAINSEWERFLEXIBLE COUPLINGWATER MAIN CROSSING SEWERTYPICAL DEPTH OF WATER MAIN 1/2" TO 8" PIPESHOULD HAVE 4' - 6" OF COVER, 10" AND LARGERPIPE SHOULD HAVE 4' OF COVER.MINIMUM ANGLE OFINTERSECTION = 30°SEWERNOT TO SCALEDETAIL 501 - SEWER / WATER LINE SEPARATIONBEB
ACH
DRAFT
AS NOTED
SITE DETAILS
16C804