HomeMy WebLinkAboutA-200�
N7
�
3
2
:I
Q
REFLECTED CEILING NOTES:
1. COOR�INATEWITHALLTRA�ES-MEP�FA�AV+SECURIiVETC.WHERE�ISCREPANCIE50CCUR.
W NTACT PROJECT ENGINEER FOR RESOLUTION PRIOR TO INSTALLING DEVICES/FlXTURES.
2. WNTACTPROJECTENGINEERBARCHITECTFORRESOLUTIONWHERE�ESIGNATEDCEILING
HEIGHTS CANNOT BE ACHIEVED DUE TO FlELD W NDITIONS.
3. ALLDIMENSIONSAREIN�ICATE�ABOVETHEFINISHE�FLOORU.N.O.
6. SEEMECHANICALPLANSFORA��ITIONALINFORMATIONONSUPPLV�IFFUSERS,RETURN
GRILLES, TRANSFER �UCTS. FIRE �AMPERS, �UCTWORK LAVOUTS, ETC.
1 5 SEE FIRE PROTECTION PLANS FORADDITIONAL INFORMATION ON SPRINKLER HEA� LOCATION
AN� HEA� TYPES, PIPING RUNS, ETG WOR�INATE WITH ELECTRICAL PLANS FORA��ITIONAL
INFORMATION ON LIGHT FlkTURE LOCATION AN� TVPES EMERGENCV AND NIGHT LIGHTS,
SMOKEDETECTORS,ETC.
6. SEESECURINPLANSFORAOOITIONALWFORMATIONONCAMERAS.MOTIONDETECTORS,ETC.
RELEASEOFORCONSTRIlCTION cENrEREoiNEacniNoiviouniRooMExcEar
�`FRs�4�, Suhjec��ocompliancewithallregula�ions
04 S�a�e antl Local Codes
�, „� CityofCarmel
I "_ ;k
o :yc,��,'.�'� ,�:;valol,r�_
1,1100.R��� ,
� ' DATE: 06��4�20
G
Q
�
F
9. NOCEILINGBREAKSSHALLBEPERMITTEDWITHINASINGLEROOMUNLESSNOTED
OTHERWISE.
10. LOCATE HVAC DIFFUSERS, REGISTERS AND LIGHTING FlXTURES WITHIN GRID LMES, UNLESS
OTHERWISE NOTED. LOCATE SPRINKLER HEA�S, SPEAKERS, RECESSE� LIGHT FlXTURES,
AN� OTHER CEILING �EVICES IN THE CENTER OF AWUSTICAL CEILING UNITS UNLESS
OTHERWISE NOTED.
11. FINISHOFHVAC�IFFUSERS.REGISTERSAN�LIGHTINGFIXTURETRIM.DRAPERYPOCKETS,
SPEAKER GRILLES AND OTHER CEILING MOUME� �EVICES SHALL MATCH CEILING GRID
FINISH UNLESS OTHERWISE NOTE�.
12. SOUND INSULATION BLANKETS WITH EXPOSED OPEN CELL FlBERS ARE NOTALLOWED IN THE
GEILING RETURN AIR PLENUM. INSUlATION IN THE CEILMG PLENUM TO BE CLOSE�-CELL
NPE.
13. PROVI�EACCESSPANELSFORANVE�UIPMENTIDEVICEABOVETHECEILMGQE.JUNCTION
BOXES AN� �AMPERS�. ACCESS PANEL IS REpUIRE� TO BE LARGE ENOUGH TO REMOVE
EdUIPMENT IF REQUIRED. LOCATION OF ACCESS PANEL TO BE FlELD VERIFlED.
E
Q
REFLECTED CEILING LEGEND:
� GB NEW GYPSUM BOARD
� ACT NEWCEILINGTILES
(ALL GRI�S TO BE CENTERE� IN ROOM
NEW WALL OR WALL INRLL,
� COORDINATE WITH PARTITION TYPE
AREANOTINCONTRACT
O J-BOX-CEILINGFWSHMOUNTE�
�Q� EXITSIGN
RX=RELOCATE�
EX= EXISTING TO REMAIN
OPEN CEILING SPRAY; REFER TO RNISH SCHEDULE
I�]
I
LIGHTING LEGEND:
v F1 A" RECESSED LINEAR LE� SLOT
— F2 RECESSEDGEOMETRICLEDMICROPROFlLE
� F3 RECESSE�2X2LEDTROFFER
� F4 4"PERIMETERSLOTCOVELIGHT
� F5 4.5"LEDROUNDDOWNLIGHT
m FX EXITSIGN
I
C
I
G?
I
I.1
,
_�
_�
_ �
REFLECTED CEILING PLAN �
SCALE: 1I8" =1'-0"
J'�
�vE R Es�
EVEREST - CARMEL, IN
11711 NORTH MERIDIAN STREET
CITY OF CARMEL, CLAY TOWNSHIP
HAMILTON COUNTY, IN 46032
=�,E".
EVERESTREINSURANCEIINSURANCE
11711 NORTH MERIDIAN STREET
CARMEL, IN 46032
r�cxrtEcr
hlw
5 PENN PLAZA STH FLOOR, NEW VORK, NV 10001
APPLIED ENGINEERING SERVICES, INC.
5975 CASTLE CREEK PARKWAV N DRNE. SUITE 300
IN�IANAPOLIS, IN 66250
r.�av�raai
��0
SIGNATURE
�``�\\`N� p I�F �� �,
��.��p� ......, Ri,� %,
,, .��,sz�RF • � ';
; :� ,
�=o,�o.�„p� =
' STATE OF�
��i� '•iiyUTANP'•'. \��
/����i��RCH ITE `%����`���
NOT FOR CONSTUCTION
I41912020 I ISSUE FOR PERMIT
!0. DATE ISSUE OR REVI;
AWMG TITLE:
REFLECTED CEILING
PLAN
Asintlicatetl 4I9I2020
'. pABY'. PROJECTNO.
MM SH 19257
ING N0.
A-200
� 7➢1ll HLW Imemauonai W