Loading...
HomeMy WebLinkAboutA-720I � HANGAR WIREATTACHED TOSTRUCTUREA80VE DRVWALLGRID � AXIOM CLIP SCHEDULED GVPSUM BOARD CEILING TAPE AN� FLOAT "ARMSTRONG"(6-INCH�AXIOM — TRIM CUSTOM COLOR RAL 70d0 6 � AXIOM CLIP, TIE BACK TO TEE BEHIND SCHEDULED RXTURE MOUNTING 9/i6 FIANGE SCHE�ULE� LIGHT FIXTURE INFlLLTILEBVARMSTRONG"100001 RALIOhO LINF" e G DETAIL - F2 ENLARGED a� AXIOM EDGE 1 z SCALE 6" = 1'-0' 5 :1 HANGER WIR ABOVE pRYWALL MP AXIOM CLIP SCHEDULED REFER TO R( SCHEDULED CEILING scnEou�Eo REFER TO R( "ARMSTRON( TRIM WST01 AXIOM CLIP HANGER WIRE TO STROCTURE ABOVE SCHEOULED FlkTURE BEHIND INFlLL TILE BV ARMSTRONG .ia000taavoaa_unF• HANGER WIRE TO STRUCTURE ABOVE FI%TURE SAFETV BRACKET ATTACHE� TO TEE GRID TEE BEYON� SCHEDULED"DESIGNSHAPES" BVARMSTRONG SCHE�ULE� LIGHT FI%TURE DETAIL - MC-1 SECTION �a LIGHT (F2/ALT�a. AXIOM � O SCALE: 3" = 1'-0' 3 2 1 RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel �!,,:,�r; ,�;va�n�! DATE: 06��4�20 �.yim� HANGER WIRE TO STRUCTURE ABOVE SCHE�ULED FIXTORE BEHIN� INFILL TILE BV ARMSTRONG 900001 RAVOG� LINF" HANGER WIRE TO STRUCTORE ABOVE FIXTURE SAFETV BRACKET nTTncHEo To TEE GRID TEE BEYOND SCHEDULED "DESIGN SHAPES" BVARMSTRONG SCHEDULED LIGHT FlXTURE DETAIL - MC-1 SECTION a� LIGHT (F2/ALT�a. ACT Q SCALE: 3" = 1'-0' � I F scHEou�Eo FixTuaE eEHiNo HANGAR WIRE TO STRUCTURE ABOVE SCH. FIXTURE SAFETY BRACKET ATTACHE� TO TEE SCHE�ULED MAIN TEE BEYOND SCHE�ULEDTEE SCHE�ULE�'DESIGNSHAPES'9VARMSTRONG SCHEDULED FlXTURE MOUNTING FIANGE 9/16' (OPTION) SCHE�ULED FlXTURE II I TII F RV ARMSTRONR YfI00M RAI ]Odfl I MF' DETAIL - F2 ENLARGED �a ACT EDGE 1 1 SCALE 6" = 1'-0' B.O.STRVCTUREABOVE 20GA 21/2" MTL STUDS SECURED TO STRUCTUREABOVEAN�BRAGE� GW8 PARTITION ABOVE CEILING. AS SCHE�ULE�ONCONSTRUCTIONPLANS SCHEDULED ACOUSTIC CEILING TILE �REFER TO RCP CEILING/SOFFIT HEIGHT CONTINUOUSV2"SHA�OW MOULDING PERIMETER, TVP. GLASS PARTITION AS SCHE�ULE� ON CONSTRUCTION PLANS CEILING - OFFICE FRONT HEADER 8 SCALE: 1 1l2" = 1'-0' E GRI� SUSPENSION AS REQUIRE� TO SUPPORT WEIGHT OF THE CEILING AND TO MEET LOCAL WDES SGHE�ULE� ACOlISTIC CEILING TILE SVSTEM 8 ACCESSORIES CONTINUOU5IR"SHADOW MOUL�ING PERIMETER, TVP. 5/e" GWB BEA�; TAPE. SPACKLE, AND FINISH CORNERS, TYP. LINEARDIFFUSERBEVONDWHERE - APPLICABLE', REFER TO RCP V � n ALIGN CEILING - PERIMETER COVE LIGHT a� GYPSUM BOARD � SCALE: 3" = 1'-0' GRID SUSPENSION AS REQUIRED TO SUPPORT WEIGHT OF THE CEILING AN� ro MEEr �ocn� cooEs SCHEDULED ACOUSTIC CEILING TILE SVSTEM 8 ACCESSORIES S SIB" 1' 6• P 0" C 9.� O.STRUCTUREABOVE - 2�GA21/2"MTLSTU�SSECUREDTO STRl1CTURE ABOVE AN� BRACE� AS RE�'D - EXISTING EXTERIOR WALL CONSTRUCTION — aw�� P�vw000 a�ocKiNc - MOTORIZE�ROLLERTUBE 8 SHADE BAND ASSEMBLY - A W MINOM FASCIA TO MATCH MULLIONS 8.0. WINDOW MULLION 9_�. B 0. WINDOW MULLION 9-2 = EXISTING EXTERIOR WINDOW ASSEMBLV - SIDETRACKSPoRBLACKOUT SHA�ESSHOWN�ASHE�. MOONT TO FACE OF MOLLION CEILING - ACT TO GWB SOFFIT 7 SCALE 1 112" = 1'-0' 0 VARIES REFER TO RGP GRID SUSPENSION AS REpUIRE� TO SUPPORT WEIGHT OF THE CEILING ANO MEET LOCAL CODES 4 -- ti � 0 a � PARTIALLV REMOVE EXISTING FINISHES TO ALLOW INSTALLATION OF BLOCKING AS REQUIRE� SCHEDULED LIGHT FIXTURE REFERTORCP � CEILING HEIG�HT SCHEDULED GVPSUM BOARD CEILING SYSTEM 8 ACCESSORIES 518" GYPSUM BEAD; TAPE, SPACKLE. AND FINISH CORNERS CONTINUE SCHEDULED WALL FlNISH UP TO BASE OF FIXTURE EXISTING PARTITION B.Y O.STRUCTUREABOVE 20GA 21/2' MTL STUDS SEWRED TO STRUCTUREABOVEANDBRACED W NTINUOUS 112" SHADOW MOULDING PERIMETER. TVP. �REFER TO RCP CEILING HEIGHT REFER TO RCP CEILING HEIGHT LIGHT FI%TURE WHERE APPLICABLE; REFER TO RCP PARTITION AS SCHE�ULED ON W NSTRUCTION PLANS 518" GWB BEA�', TAPE, SPACKLE, AN� FINISH CORNERS AS REQUIRED. TYP. CEILING - ACT TO LOWER GWB SOFFIT � SCALE: 1 112" = 1'-0' � � 20GA2V2"MTLSTUDSSECURE�TO STRUCTUREABOVEANDBRACEDAS � I REQ'D u. —_—I-------------- 0 0 0 0 0 0 veve°°evee __________________ CeunG neGnr ,� _____°°eve°e _ REFE�� _ _ SCHEDULED SUSPENDED 5/0" THICK GYPSUM WALLBOARD CEILING ACOUSTIC TILE CEILMGBACCESSORIES ALIGN CONTINUOUSMETALCORNER 1/2" WNTINUOUSSHA�OW MOLDING (TVPICAL) GYPSUM BOARD FLUSH TO ACOUSTIC CEILING TILE CT� SCALE: 3" = 1'-0' B I A UNDERSI�E OF SLAB a/-14�_3• (V.I.F.) SCHE�ULE�SUSPENDE� CBLING ACOUSTIC TILE CEILING & ACCESSORIES CEILING HEIGHT REFER TO RCP 1/P CONTINUOUS SHADOW MOL�ING�TYPICAL) SCHEDULEDOR EXISTING PARTITION TYP. ACT CEILING � PARTITION 4 SCALE: 3" = 1'-0' � v l_/ ______________________________-__ ____________________ ,� o ��� �o o �� o o� o o— I� o o �o 0 0� � IJ �'-2�PoT � \� susaENOEocEwNc ACOl1STICTILE � SCHEDULEDSUSPEN�E�CEILING GRI� SVSTEM j TEST50% OFANCHORS FOR 4d0 LBS IN TENSION AND 50 o FOR 200 LBS GRID SUSPENSION AS REQUIRE� TO SUPPORT WEIGHT OF THE CEILING AN� TO MEET LOCAL CODES REFER TO RCP CEILMG HEIGHT TYP ACT CEILING - TEGULAR FIELD � SCALE: 6" = 1'-0' .aoo nEno oRivE ain �nRaa zsaoa sTee� sTRnP r� wioe x 2' LONG X 12GA MINIMOM 12 GA (UNLE55 NOTED OTHERWISE) VERTICAL HANGARWIRE NOLESSTHAN3TIGHTTURNS WITHIN A DISTANCE OF 1 1/2' 12GA.SPLAVEDSEISMICWIRE. NOLE55 — THAN 4 TIGHT TORNS WITHIN A DISTANCE OF 1 112" — � B.O.STRUCTUREABOVE \� �2.. CEILING - SUSPENSION WIRE �a CONCRETE SLAB (TYP.� 2 SCALE: 6" = 1'-0" 45°MAX.� 45�MAX. iNP� I /I I (T�P) TYPICAC 12 GA. VERTICAL HANGER WIRE @ A'0" EA. WAV W/ MIN. 3 TIGHT TURNS IN 1 12" BOTH EN�S OF WIRE. 12 GA. BRACING WIRE WI MIN.4 TIGHTTURNS IN 1 V2' BOTH ENOS OF WIRETYPICAL PLACE SETS OF BRAQNG WIRES AT NOT MORE THAN 12 FEET BY 12 FEET APART AND NOT MORE THAN 1/2 THE 12 FEET BY 12 FEET SPACING FROM EACH PERIMETER WALL AT THE EDGE OF VERTICAL CEILING OFFSETS MAINRUNNER' PREW�EkL15/i6"E%POSE� TEE,OREQUAL CROSSRUNNER�. PRELU�EXL15116"EXPOSED TEE.OREQUAL 2" (MAX.) FROM BRAQNG WIRES TO CROSS RUNNERS � PROVIDE PRELU�E XL 1511fi" EXPOSED TEE ORAPPROVED EQUAL CEILING - SUSPENSION SYSTEM � SCALE: 3" = 1'-0' J� �vE R Es� EVEREST - CARMEL, IN 11711 NORTH MERIDIAN STREET CITY OF CARMEL, CLAY TOWNSHIP HAMILTON COUNTY, IN 46032 EVERESTREINSURANCEIINSURANCE iP11 NORTH MERIDIAN STREET CARMEL, IN 46032 nvartem hlw 5 PENN PLAZq STH FLOOR, NEW VORK. NV 100�1 APPLIED ENGINEERING SERVICES, INC. 5975 CASTLE CREEK PARKWAV N DRNE. SUITE 300 IN�IANAPOLIS, IN 66250 I:Ii9919P1 rc�0 SIGNATURE \\\\\\O�N p�IG��//////// ,� � .��,s-r�RF ti� %; � : Q- � ���yr1o.�11�p1 •• = STATE OF� % �'•�NUiAN?'.•. \�� /����i��RCH'TEL�������\ NOT FOR CONSTUCTION I41912020 I ISSUE FOR PERMIT !0. DATE ISSUE OR F AWMG TITLE: CEILING DETAILS Asintlicatetl 4I9I2020 . pABP. PROJECTNO. MM SH 19257 ING N0. A-720 � � x�w ���,�a�o�,� �