ELECTRICAL ABBREVIATIONS:
i
�
i
0
NOTE: ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION ON THE DRAWINGS. ALL SYMBOLS NOT NECESSARILY USED ON THIS PROJECT.
RACEWAY SYMBOLS: FIRE ALARM SYMBOLS: GENERAL SYMBOLS:
CONDUIT FACP FIREALARMCONTROLPANEL NEW
WNDUIT WNCEALED UNDER ROOR OR BELOW GRAOE FAAP FIREALARM ANNUNCIATOR PANEL EXISTING
� UNDERGROUNDCONDUITSTUBBEDOUTS-0"FROMBUILDINGORWALKWAVLINE, qC NOTIFICATIONALARMCIRCUIT DEMOLITION
CAPPEDAND MARKED �
�� F� FIRE ALARM MANUAL PULL STATION, 48" AFF FUTURE
HOME RUN TO PANEL "B" FOR QRCUITS #5 8] WITH COMMON NEUTRAL AND GROUND
RRE ALARM MANUAL PULL STATION, AUDIO-VISUAL INDICATING DEVICE
• CONDUIT UPIDOWN � CENTEREO ABOVE THE PULL STATION, 48" AFF AND ♦80" AFF � POINT OF CONNECTION
LIGHT OUTPUT ]5 cd UNLESS OTHERW ISE NOTED �
+O JUNCTIONBOXCONCEALEDABOVEACCESSIBLECEILINGAREA � FIREALARMVISUALONLVINDICATINGDEVICE,+gp"AFF ,.y
L"—�`� LIGHT OUTPUT �5 cd UNLESS OTHERWISE NOTED irr POINT OF REMOVAL
RECEPTACLE SYMBOLS: Y
� 2�AMPDUPLEXGROUNDINGRECEPTAQE+20"AFFUNLESSOTHERWISENOTED
� 20AMP DUPLEX 6ROUNDING RECEPTAQE, EMERGENCV POWER
� 20 AMP DUPLEM GROUNDING RECEPTACLE, SPLIT WIRED
� 2� AMP DUPLEX GROUNDING RECEPTAQE, GROUND FAULT INTERRUPTING QRCUIT
� 20 AMP DUPLE%GROUNDING RECEPTACLE, EMERGENCV POWER,
GROUND FAULT INTERRUPTING CIRCUIT
� 20 AMP DOUBLE pUPLEX GROUNDING RECEPTACLE IN TWO GANG OUTLET BO%
� 20AMPDOUBLEDUPLEXGROUNDIN6RECEPTACLEEMER6ENCVPOWER
� 20AMP DOUBLE DUPLEX GROUNDING RECEPTACLE GROUND FAULT IMERRUPTING CIRCUIT
3y 20AMPDOUBLEDUPLEXGROUNDINGRECEPTACLE,EMERGENCVPOWER,
�� GROUNDFAULTINTERRUPTINGCIRCUIT
� FLOOR�UPLEXRECEPTACLEOUTLET. SEEDRAWINGFORTVPE
LIGHTING CONTROL SYMBOLS:
$' 20 AMP POLE TOGGLE SWITCH 48" AFF. INSTALL MULTIPLE SWITCHES UNDER COMMON
COVERPLATE SUBSCRIPTATSWITCHSVMBOLINDICATESTHEFOLLOWING:
TOP: 2- DOIIBLE POLE 4- FOUR WAV M- MOMENTARV
3-THREEWAV P-PILOTLIGHT K-KEVOPERATED
D-DIMMER LFLIGHTCONTROLLER BLANK-SINGLEPOLE
BOTTOM: a,b,qd, ETC-- IDENTIFICATION OF CONTROLLED DEVICE
� OCCUPANCVSENSORSWITCH,CEILINGMOUMED
1� OCCUPANCVSENSORSWITCH,WALLMOUNTED
LC 8-ZONELIGHTINGCONTROLLER
OR ZONEOVERRIDESWITCH
POWER/MOTOR CONTROL SYMBOLS:
� PANELBOARD OR EpUIPMENT CABINET AS INDICATED
� MOTOR, NUMBER INDICATES HP
$> MANUAL MOTOR STARTER WITH THERMAL OVERLOADS AND PILOT LIGHT, 48" AFF
SAFETY(DISCONNECT�SWITCH,INSTALLAT60"AFF, "F"INDICATESFUSESIZE,
�X BLANKINDICATESNON-FUSED,"X"IN�ICATESAMPERAGER4TING
� COMBINATIONSTARTER: SEESCHEDULE.
LIGHTING SYMBOLS:
F# EM
�LIGHTING FIXTURE. "x" INDICATESZONE. "Fk" INDICATESTVPE. EM INDICATES
EMERGENCV FIXTURE WITH EMERGENCV BATTERV DRNER, NL - INOICATES NIGHT
LIGHT FIXTURE (ALWAVS ON)
" NL
a
ROUND LIGHTIN6 FlXTURE "a" INDICATES SWITCH WG, "F#" INDICATES TYPE
F#
� CEILINGMOUNTE�SINGLEFACEEXITSIGN.ARROWINDICATESOIRECTIONAL
f ARROW ON EXIT SIGN FACE
I—� EXITSIGN,WALLMOUNTEDS'-0"AFFUNLESSOTHERWISENOTED
CEILWG WALL
��� FIRE ALARM AUDIO/VISl1AL INDICATING OEVICE, WALL MOUNT+80" AFF
✓`J"`� LIGHTOUTPUP5cdUNLESSOTHERWISENOTED
F,Tn FGIn FIRE ALARM SPEAKER/VISUAL INDICATING DEVICE, WALL MOUNT+80" AFF
�I�� J�� LIGHTOUTPUP5cdUNLESSOTHERWISENOTED
5�' S�' FIREALARMSPEAKERONLVINDICATINGDEVICE,WALLMOUNT+80"AFF
�� FIRE ALARM VISUAL ONLV INDICATING DEVICE, WALL MOUNT +80" AFF
L"—�`� LIGHTOUTPUT75cdUNLESSOTHERWISENOTED
� � FIREALARMCHIMEONLVINDICATING�EVICE,WALLMOUNT+80"AFF
� � FIREALARMAUDIOHORNIN�ICATINGDEVICE,WALLMOUNT+80"AFF
� BELL
S� AREASMOKE�ETECTOR
H� AREA HEAT DETECTOR
FS FLOWSWITCH,FIREALARM
TS TAMPERSWITCH,FIREALARM
DS DOORSWITCH,FIREALARM
AS AIR DUCT SMOKE DETECTOR MOUNTED ON AIR DUCT
LA LOW AIR
PS PRESSURESWITCH
TELECOMMUNICATION SYMBOLS:
Q x DATA OUTLET IN TWO GANG BOX WITH SINGLE GANG
OPENING, "X"INDICATESNUMBEROFVOICEIDATAJACKS
, x HDMI OUTLET IN TWO GANG BOX WITH SINGLE GANG
OPENING, "X"INDICATESNUMBEROFVOICEJACKS
�%IX RUSHROORVOICE/DATAOUTLET,
"X/X" INDICATES NUMBER OF VOICE/DATA JACKS
FLOOR PIQ DATA OUTLET CONSISTS OF (2) DATA OUTLETS
�X UNLESSOTHERWISENOTED,EACHALPHACHARACTER"X"
INDICATES NUMBER OF UNIQUE DATA JACKS
CEILING MOUNTED PIC, DATA OUTLET CONSISTS OF (2) OATA
� AGX OUTLETS, UNLESS OTHERWISE NOTED, EACH ALPHA
CHARACTER "X" INDICATES NUMBER OF UNIQUE DATA JACKS
CBLWG MOUMED WIRELESS ACCESS POINT PIC, �ATA OUTLET
AP-X CONSISTS OF (2) DATA OUTLETS, UNLESS OTHERWISE NOTED, EACH
ALPHA CHARACTER "X" INDICATES NUMBER OF UNIQl1E OATA JACKS
� TELEVISIONNIDEOOUTLETINTWOGANGBOX.PROVIDE
WITH 1 COAX CABLE ROUTED BACK TO IDF ROOM.
PROVIDE M EACH CAN WALL BOX.
SECURITY/ACCESS CONTROL SYMBOLS
�R CARDREADER
� DOOR RELEASE
N/C
1/C
20AF
3P
A. AMP
ACCU
AFF
AHU
CH
E
EF
FCU
GFI
GND
HP
IG
KVA
KW
NL
OL
PROVIDE
RTU
TVP
UON
V
WC
WG
WP
C
MULT6CONDUCTORCABLE
SINGLE CONDUCTOR CABLE
20 AMP FUSES
3 POLE
AMPERE
AIR COOLED CONDENSING UNIT
ABOVEFINISHEDFLOOR. MOUNTINGHEIGHTS
FROM FINISHED FLOOR TO TOP OF BOX.
AIR HANDLWG UNIT
CABINET HEATER
E%ISTING EQUIPMENTTO BE REUSED
EXHAUSTFAN
FAN COIL UNIT
GROUND FAULT MTERRUPTER
GROUN�
HORSEPOWER
ISOLATED GROUN�
KILOVOLT AMPERES
KILOWATT
NIGHT LIGHT ON UNSW ITCHED CIRCUIT
OVERLOAD
FURNISH, INSTALL AND CONNECT.
ROOF TOP UNIT
TVPICAL
UNLESS OTHERWISE NOTED
VOLTS
WATERCOOLER
W IRE GUARD
WEATHERPROOF
GENERAL FIRE ALARM NOTES:
1. FIRE ALARM OESIGN SHALL CONTAIN NO MORE THAN ]0 % LOAD ON EACH PANEL
AND LOOP LEAVING 30% AVAILABLE FOR FUTURE CAPACITV PER qRCUIT.
CONTRACTOR SHALL PROVIDE A COMPLETE FIRE ALARM LAVOUT CERTIFIED BV A
PROFESSIONALENGWEER. CONTRACTORSHALLPROVIpEALLMATERIAL
NECESSARV FOR A FULLV FUNCTION SVSTEM. CONTRACTOR SHALL PROVIDE ALL
ADDITIONAL BUILDING MATERIAL (NAC PANELS, POWER SUPPLIES, ETC.).
2 CONTRACTOR MAV UTILIZE OPEN FIRE ALARM CABLING OR ARMORED FIRE ALARM
CABLING W HEN INSTALLING CONDUCTORS ABOVE ACCESSIBLE CEILINGS AND
BEHIN� ACCESSIBLE CHASES. FIRE ALARM CABL W G SHALL 8E INSTALLED IN
RACEWAV ABOVE INACCESSIBLE CEILINGS AND BEHIND INACCESSIBLE CHASES
ANp WALLS. IN ALL OPEN PUBLIC SPACES. FlRE ALARM CABLING SHALL BE
INSTALLED IN RACEWAV (SURFACE RACEWAV) AND RACEWAV SHALL BE PAINTED
TO MATCH WALLSICEILING SURFACE ON WHICH THE RACEWAV IS INSTALLED.
3. OPEN FIRE ALARM CABLING NOT WSTALLEO IN RACEWAV SHALL BE PLENUM
RATED, NO EXCEPTION.
6. CONTRACTOR SHALL ADJUST DEVICE LOCATIONS BV 11P TO 30" FROM WHAT IS
SHOWN TO AVOID OBSTRUCTIONS.
GENERAL ELECTRICAL NOTES:
1. ALL WORK SHOWN IS NEW AND BV THE ELECTRICAL TRADES, UNLE55OTHERWISE
NOTED
2. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE (NFPA �0) AND NATIONAL FlRE ALARM CODE (NFPA
]2) AS ADOPTED BV THE STATE INCLUDING ALL AMEN�MENTS.
3. THISCONTRACTORSHALLREVIEWTHECOMPLETESETOFDRAWINGSAND
SPEqFICATIONS AND INCLUDE WORK FROM OTHER DIVISIONS THAT AFFECT HIS
WORK IN HIS BI�.
4. CONTRACTOR SHALL VISIT PROJECT SITE, PRIOR TO BIDOING, TO REVIEW
EXISTING ELECTRICAL, SECURITY, AND FlRE ALARM CONDITIONS. NOT ALL
EXISTING ELECTRICAL EQl11PMENT, WIRING DEVICES AND RACEWAVS ARE
SHOWN.
5. EACH CONTRACTOR SHALL FIELD VERIFV ALL EXISTING APPLICABLE CONDITIONS
AND DIMENSIONS SHOWN ON THE DRAWINGS, AS PERTAINS TO THE INTENT OF
THESE DRAWINGS. CONTRACTOR SHALL BR WG TO THE ATTENTION OF THE
ENGINEER AND DESIGNER ANY DISCREPANQES PRIOR TO THE COMMENCEMENT
OF ANV WORK AFFECTED BV OR RELATED TO SUCH DISCREPANCV. EACH
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH OR
CAUSED BY THAT CONTRACTOR'S FAILURE TO COMPLV WITH THIS REQUIREMENT.
6. POWER,SECURITV,ANDFIREALARMINTERRUPTIONSMUSTBEPROPERLV
PURSUED TO REDUCE INCONVEMENCE TO THE NORMAL BUILDING ACTIVITV TO A
MINIMUM. ARRANGEMENTS FOR INTERRUPTION OF ELECTRICAL SERVICE TO
BUILDING MUST BE MADE IN WRITING WITH THE SUPERINTENDENT AND PROJECT
MANAGER AT LEAST ONE WEEK BEFORE THE PROPOSED INTERRUPTIONS.
1. INTERRUPTIONS OF SERVICE IN AREAS WHERE BUILDING PERSONNELARE
WORKING WILL BE MADE BETWEEN THE HOURS OF 11:00 P M. AND 6:00 A.M.
UNLESS APPROVEO BY SUPERINTENDENT, OWNER'S SECURITY PERSONNEL, AND
OW NER'S FIRE ALARM PERSONNEL.
8. DEMOLITION SHALL BE PERFORME� TO MINIMIZE DAMAGE TO ADJACENT
RETAWED WORK. WHERE SUCH DAMAGE OCCURS, PATCH, REPAIR OR
OTHERWISE RESTORE TO ITS ORIGINAL CONDITION.
9. WHEREDEMOLITIONWORKLEAVESHOLESANDDAMAGE�SURFACETHATWILL
BE EXPOSED IN FINISHED WORK OR THROUGH A FIftE SEPARATION, THESE HOLES
AND DAMAGED SURFACES SHALL BE PATCHED AND REPAIRED TO MATCH
ADJACENT FINISHED SURFACE.
10. CONTRACTOR SHALL INCLUDE IN HIS BID THE REMOVAL AND PROPER DISPOSAL
OF ALL EXISTING ELECTRICAL EQUIPMENT INDICATED TO BE REMOVED.
HOW EVER, THE OWNER HAS THE FIRST RIGHT TO REFUSAL OF ALL EXISTING
ELECTRICAL EpUIPMENT.
11. FOR ALL REMOVED FIRE ALARM DEVICES, REMOVE ALL EXISTING RACEWAV AND
WIRING TO SOURCE OR FlRST ACTIVE TO REMAIN JUNCTION BOX.
12. MAINTAIN SERVICE CONTINUITV TO ALL EXISTING LOADS THAT ARE TO REMAIN BV
MO�IFVINGAN�IOREXTENDINGCONDUITANDWIRINGASRE�UIRED. FlEL�
VERIFICATION OF EXISTING CONDUIT RUNS AN� CIRCUITRY IS TO BE OONE AS
REQUIRED. THISINCLUDES.BUTISNOTLIMITEDTORECEPTACLES,OVERHEAD
POWER DROPS, DISCONNECTS, LIGHTING, AND MECHANICAL EpUIPMENT.
13. UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL CUTTMG AND PATCHING
REQUIRED FOR THE ELECTRICAL, SECURITV, AND FIRE ALARM INSTALLATION
SHALL BE PERFORMED BY THE APPROPRIATE TRADE AND PAID FOR BV THIS
CONTRACTOR. ALL CUTTWG AND PATCHING SHALL BE IN ACCORDANCE WITH THE
APPLICABLE ARCHITECTURAL DETAILSINOTES.
14. ALL FIRESTOPPING SHALL BE PROVIDED UNDER DIVISION 0], "FIRESTOPPWG'.
15. VERIFY EXACT LOCATION OF OUTLETS ABOVE COUNTERS, IN CASEWORK OR
EQUIPMENT PRIOR TO ROUGH M.
i6. COOR�INATE INSTALLATION OF �EVICES AND WIRING WITH LIGHTING, HVAC,
PIPING, AND STRUCTURAL MEMBERS.
1]. EMERGENCVLIGHTINGFIXTURES-TESTSWITCHANDINDICATORLAMPARETOBE
LOCATED IN A READILV VISIBLE LOCATION. IF INSTALLATION INSTRUCTIONS BV
MANUFACTURERDONOTALLOWFORTHIS. MOUNTSWITCHANDLAMPINSINGLE
GANGBOXFLUSHMOUMEDINCEILINGTILEADJACENTTORXTURE BODME
SELLS A COVER-PLATE FOR THIS PURPOSE. FLE%CONDUIT CAN BE 115ED
BETWEEN RXTURE AND BOX.
18. GFCI qRCUIT SHALL BE WSTALLED SUCH THATGFCI RECEPTACLE SHALL ONLV
TRIP ITSELF AND DOES NOT TRIP OR DISCONNECT PO WER ON ANV OTHER
RECEPTACLE.
19. LOW-VOLTAGE CONDUIT SHALL NOT CONTAIN MORE THAN 2]�� IN BENDS
BETWEEN FLOOR BOMES, A/V EQUIPMENT RACKS, FlRE ALARM DEVICE BOXES,
FIRE ALARM PANELS, SECURITV DEVICE BOXES, ANO SECURITV PANELS. PROVIDE
PULL BOXES IN RACEWAVS THAT CONTAIN MORE THAN 2�0° IN BEN�S. PROVIDE A
MINIMUM OF ONE (i ) PULL BOX FOR EVERY 100 FEET OF RACEWAV.
20. CONTRACTOR SHALL PROVIDE MINIMUM 200 LB TENSION PULL STRING IN ALL
EMPTV/FUTIIRE 115E RACEWAVS.
21. ALLCONDUITROUTEDINANDTHROUGHWNCRETEAND/ORBUILDING
STRl1CTURAL WALLS SHALL BE RIGID METAL CONDUIT, UNLESS OTHERWISE
NOTED.
22 TURN OVER ALL KEVS TO OWNER AT COMPLETION OF PROJECT.
23 RRE STOP ALL WALL AND ROOR PENETRATIONS WHETHER SURFACE IS RATED
ORNOT
24. DEVICELOCATIONSSHOWNAREDIAGRAMMATIC. CONTRACTORSHALLVERIFV
ALL CONDITIONS PRIOR TO STARTING CONSTRUCTION.
i
1�
�vE R Es-�.
cuc�i
EVEREST REINSURANCE I INSURANCE
11]11 NORTH MERIDIAN STREET
CARMEL IN 46032
nuxn�cr
5 PENN PLAZA, STH FLOOR. NEW YORK, NV 10001
� �
Applied
Engineering Services
5975CastleCreekParkwayNDrive,Suite300 • Intllanapolis,Indiana46tS0
Te1:317.810.4141 • Faz:317.810.4140 •www.applied-e-s.com
I\Y19C1d1
S16NATURE
����NSDT�E ORq�G
: �F'G RF-�....
fNo. PE11100325�'-.
4!24/202D
r�0
ELECTRICAL SYMBOLS
AND ABBREVIATIONS
u
NDL I LDH
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
r
�un��V l�rcNalM��
DATE: 06�04�20
E-001