Loading...
HomeMy WebLinkAboutG-001i l�l N7 � 3 2 1 :I G F I E GENERALNOTES: 1. THE CONTRACTOR SHALL COMPLY WITH THE AUTHORITY HAVING JURISDICTION AND ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES PERTAINING TO THE SAFETY OF PERSONS PROPERTY AND ENVIRONMENTAL PROTECTION. 2. THE CONTRACTOR SHALL REVIEW THE GENERAL CONDITIONS AND THE SUPPLEMENTARY CONDITIONS BEFORE COMMENCWG WORK. 3. REFER TO THE PROJECT MANUAL, INCLUDING THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND GENERAL REQUIREMENTS [DIVISION-1� FOR INFORMATION THAT IS APPLICABLE TO ALL TRADES. REFER TO THE TECHNICAL SPECIFICATIONS. 4. THE CONTRACTOR SHALL COORDINATE THE PERMITTING PROCESS TO SECURE BUILDING PERMITS AND ALL OTHER PERMITS AND LICENSES, PAY ALL FEES AND SHALL OBTAIN FINAL APPROVAL OF ALL JURISDICTIONAL AUTHORITY. 5. THE CONTRACTOR SHALL COORDINATE AND COOPERATE IN OBTAINING ALL REQUIRED INSPECTIONS, CLOSE- OUT, AND CERTIFICATE OF OCCUPANCY. 6. ALL CONSTRUCTION DIMENSIONS AND DETAIL SHALL CONCUR WITH AND BE DETERMINED FROM THESE DRAWINGS ONLY. DRAWINGS SHALL NOT BE SCALED. NOTED DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. CONTRACTOR TO IMMEDIATELY REPORT TO ARCHITECT ANY DISCREPANCIES FOUND IN THE FIELD. 7. REPETITIVE FEATURES NOT COMPLETELY DESCRIBED ANDIOR DETAILED SHALL BE CONSTRUCTED W EXACT ACCORDANCE WITH CORRESPONDING FEATURES WHICH ARE COMPLETELY DESCRIBED OR DETAIL. 8. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND CONDITIONS. CONTRACTOR SHALL NOTIFYTHE ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH ANY WORK. NO CHANGES SHALL 8E MADE TO PLANS WITHOUT PRIOR CONSENT OF THE CLIENT AND THE ARCHITECT. 9. ITEMS DAMAGED AS A RESULT OF ANY CONTRACTOR'S WORK SHALL BE REPLACED OR REPAIRED IN FULL EXTENT BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 10. THE OWNER RESERVES THE RIGHT AT ALL TIMES TO DELNER, PLACE, AND INSTALL EQUIPMENT AND FURNISHINGASTHEWORKPROGRESSES MCOORDINATIONWITHTHECONTRACTOR. 11. TENANT PROTECTION PLAN SHALL BE PROVIDED PER LOCAL JURISDICTION REQUIREMENTS AND INCLUDE PROVISIONS FOR EGRESS, FIRE SAFETY, HEALTH REQUIREMENTS, STRUCTURAL SAFETY AND NOISE RESTRICTIONS. 127HE CONTRACTOR SHALL REVIEW AND FOLLOW THE LOCAL JURISDICTION, STATE, FEDERAL LAW, AND THE OWNER OF THE PROPERTY PRIOR TO THE START OF CONSTRUCTION. 13, CONTRACTOR SHALL CONFIRM AND COORDINATE PHASING OF DEMOLITION WORK WITH THE AUTHORIN HAVING JURISDICTION AND OWNER'SILANDLORD'S PHASING SCENARIO. 14, NOTES APPEAR ON VARIOUS SHEETS FOR VARIOUS SYSTEMS AND MATERIALS. SHEETS SHALL BE REVIEWED AND NOTES ON ANY ONE SHEET SHALL BE APPLIED TO RELATED SYSTEMS AND MATERIALS SHOWN ON OTHER DRAWINGS. 15. THE TERM "FINISHED FLOOR" AS INDICATED ON THE DRAWINGS, REFERS TO THE FINISHED WALKING SURFACE OF THAT FLOOR LEVEL. HEIGHTS NOTED IN SCHEDULES ARE HEIGHTS ABOVE THE FINISH FLOOR, UNLESS OTHERWISE NOTED. 16. INTERIOR PARTITIONS SHALL NOT BE COMPLETED TO FULL HEIGHT UNTIL ALL OVERHEAD TRADES ARE COMPLETE. 17. SUSPENDED ACOUSTICAL CEILING TILE OR PANELS SHALL NOT BE INSTALLED UNTIL ALL OTHER ENGINEERING TRADES AND FIRESTOPPING WORK ABOVE THE CEILWG IS TESTED AND APPROVED. 18. THE CONTRACTOR SHALL PROVIDE ALL CLEANOUTS AND ACCESS PANELS PER SYSTEM REQUIREMENTS. 19. ALL ITEMS RECESSED INTO ONE-HOUR OR TWO-HOUR FIRE RATED PARTITIONS jSUCH AS OUTLET BOXES, PANEL BOXES, ETC.] SHALL HAVE THE OPENINGS PROTECTED WITH BACK-UP MATERIALS SOAS TO RETAIN THE INTEGRITY OF THE FIRE RATING OF THE PARTITION OR BARRIER THROUGHOUT. NO ITEMS SHALL BE RECESSED IN THREE-HOUR FIRE RATED PARTITIONS. 20, ALL DIMENSIONS ARE DIMENSIONED FROM THE FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR" OR "HOLD" TO ALLOW FOR THICKNESS OF FINISHES. 21. ALL INTERIOR GLAZING TO BE SAFETY GLAZING IN ACCORDANCE WITH APPLICABLE CODES. 22. PATCH AND REPAIRALL FIRE RATED ASSEMBLIES AS REQUIRED TO MAINTAIN SPECIFIED FIRE-RESISTANCE RATING, 23. PROVIDE WATER RESISTANT TILE BACKER BOARD AT ALL WALL TILE LOCATIONS. 24. PROVIDE WATER RESISTANT MEMBRANE BELOW ALL FLOORS IN WETAREAS. 25. ALL L4N IDF MDF AND ELECTRIC ROOMSICLOSETS TO RECEIVE 314" FIRE RETARDANT PAINTED PLYWOOD ON WALLS TO RECEIVE EQUIPMENT. PLYWOOD TO BE FROM FINISHED FLOOR T08'-0" ABOVE FINISH FLOOR. FIRE RETARDANT LABELS ARE NOT TO BE PAINTED. 26. PROVIDE NEW INSULATION ON SECTIONSIRUNS OF DUCT AND PIPE WHERE INSULATION WAS PREVIOUSLY DAMAGED, AS RE�UIRED. INSULATION TO BE W LIKE KIND TO EXISTINGIDAMAGED AND TO THE SAME FINISH AND QUALITY, UNLESS OTHERWISE NOTED. 27. SEE MECHANICAL PLANS FOR ADDITIONAL INFORMATION ON SUPPLY DIFFUSERS, RETURN GRILLES, TRANSFER DUCTS, FIRE DAMPERS, DUCTWORK LAYOUTS, ETC. WHERE DISCREPANCIES OCCUR BETWEEN ARCHITECTUR4L AND MECHANICAL DRAWINGS; CONTACTARCHITECT FOR RESOLUTION PRIOR TO SUBMITTING SHOP DRAWINGS. 28, SEE FIRE PROTECTION PLAN FOR ADDITIONAL INFORMATION ON SPRINKLER HEAD LOCATIONS AND HEAD TYPES, PIPING RUNS, ETC. WHERE DISCREPANCIES OCCUR BETWEEN ARCHITECTURAL AND FIRE PROTECTION DRAWINGS, CONTACTARCHITECT FOR RESOLUTION PRIOR TO SUBMITTING SHOP DRAWINGS. 29. SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION ON LIGHT FIXTURE LOCATIONS AND TYPES, EMERGENCYAND NIGHT LIGHTS, SMOKE DETECTORS, ETC. WHERE DISCREPANGES OCCUR BETWEEN ARCHITECTURAL AND ELECTRICAL DRAWWGS, CONTACT ARCHITECT FOR RESOLUTION PRIOR TO SUBMITTWG SHOPDRAWINGS. 30, CONTRACTOR SHALL COORDINATE SECURITY REQUIREMENTS WITH THE OWNER'S SECURITY VENDORS. WHERE DISCREPANCIES OCCUR BETWEEN ARCHITECTURALAND SECURIN DRAWINGS, CONTACTARCHITECT FOR RESOLUTION PRIOR TO SUBMITTING SHOP DRAWINGS. 31. DISCOVERY OF ANY HAZARDOUS MATERIALS ON SITE SHALL BE IMMEDIATELY REPORTED TO THE OWNER. 32. CONTRACTOR SHALL MAINTAIN ACCESS TO EMERGENCY EXISTS AT ALL TIMES. 33. CONTRACTOR TO ISOLATE ALL DISSIMILAR METALS. ABBREVIATIONS: ACT ACOUSTICALTILE LAV. LAVATORY ADD'T ADDITIONAL LBS. POUNDS ADJ ADJACENT,ADJUST(ABLE) LDR. LEADER A.F.F. ABOVE FINISHED FLOOR LINO. LINOLEUM A.F.S. A80VE FINISHED SLAB LKR, LOCKER AGG. AGGREGATE LOC. LOCATION ALT. ALTERNATE,ALTERNATIVE L.P. LOWPOINT ALUM. ALUMINUM LT. LIGHT APPROX. APPROXIMATE LVL. LEVEL ARCH. ARCHITECT(URAL) MACH. MACHINE AUTO. AUTOMATIC(ALLY) MAINT. MAINTENANCE A.V. AUDIOVISUAL MAT. MATERIAL AVG. AVERAGE MAX. MAXIMUM @ AT MECH. MECHANICAL BD. BOARD MED. MEDIUM BLDG. BUILDING M.E.R. MECHANICALEQUIPMENTROOM BLK BLOCK MEZZ. MEZZANINE BLK'G BLOCKING MFG. MANUFACTURQNG)(ER) B.O. BOTTOM OF M.H. MOUNTING HEIGHT B.P. BASE PLATE MIN. MINIMUM CAB. CABMET MISC. MISCELLANEOUS C.G. CORNERGUARD MTD. MOUNTED CIR. CIRCLE, CIRCULAR MTL METAL CIRC. CIRCUMFERENCE M.O. MASONRYOPENING C.J. CONTROLJOINT N.I.C. NOTIN CONTR4CT C.L CENTERLWE N0. NUMBER CL. CLOSET NOM. NOMINAL CLG. CEILING NS.S. NOTTOSCALE CLR. CLEAR,CLEARANCE # NUMBER C.M.U. CONCRETEMASONRYUNIT O.C. ONCENTER COL. COLUMN O.D. OUTSIDE DIAMETER CONC. CONCRETE OFF. OFFICE CONF. CONFERENCE O.H. OVERHEAD, OPPOSITE HAND CONN. CONNECTION,CONNECTOR OPP. OPPOSITE CONST. CONSTRUCTION OPNG. OPENWG CONT. CONTINUOUS PA PUBLICADDRESS CONTR. CONTRACTOR PART. PARTIAL CONV. CONVECTOR P.E. PASSENGERELEVATOR CORR. CORRIDOR PERIM. PERIMETER CPT. CARPET PERP. PERPENDICULAR C.T. CERAMICTILE PL. PLATE C.W. CURTAINWALL P.L PROPERTYLWE DEG. DEGREE P. LAM. PLASTIC LAMINATE DEMO. �EMOLITION, DEMOLISH PLAS. PLASTER DEPT. DEPARTMENT PLY. PLYWOOD DET. DETAIL PNL. PANEL D.F. DRINKING FOUNTAIN POL. POLISHED DIA. DIAMETER PSF. POUNDS PER SQUARE FOOT DIAG. DIAGONAL PSI. POUNDS PER SQUARE INCH DIFF. DIFFUSER PT. PAINT DIM. DIMENSION PTN. PARTITION DISP. DISPENSER Q.T. QUARRYTILE DIV. DIVISION, DIVIDED QTY. QUANTITY DN. DOWN R. RISER DR. DOOR R4 RETURNAIR DW. DRYWALL RAD, RADIUS DWG. DRAWWG RCA RECYCLEDCONCRETEAGGREGATE EA. EACH R.D. ROOF DR41N EL ELEVATION REF. REFRIGERATOR OR REFERENCE ELEC. ELECTRIC(AL) REINF. REINFORCE(D) ELEV. ELEVATION,ELEVATOR REQD. REQUIRED EMER. EMERGENCY RET. RETURN ENCL ENCLOSURE, ENCLOSED REV. REVISION ENTR. ENTRANCE RM. ROOM EQ. EQUAL R.O. ROUGH OPENING EQUIP. EQUIPMENT SCHED. SCHEDULE E.W.C. ELECTRIC WATER COOLER SECT. SECTION EXIST. EXISTING SEP. SEPARATE EXP. EXPANSION S.F. SQUARE FEET EXT. EXTERIOR SHT. SHEET F.A. FIREALARM SIM. SIMILAR F.D. FLOOR DRAIN SLD. SEALED F.E. FIRE EXTINGUISHER S.N.D. SANITARY NAPKIN DISPENSER F.E.C, FIRE EXTINGUISHER CABWET S.N.R, SANITARY NAPKIN RECEPTACLE F.F. FINISHED FLOOR SPEC. SPEGFICATION F.H.C. SIREHOSECABINET SPK. SPEAKER F.H.R. FIRE HOSE RACK SPKLR. SPRINKLER(ED) FIG. FIGURE SQ. SQUARE FIN. FINISH(ED) S.S. STAINLESS STEEL FIXT. FIXTURE STL. STEEL FL FLOOR STC SOUNDTRANSMISSIONCLASSIFICATION FLOUR. FLUORESCENT STD. STANDARD F.O. FACEOF STOR. STORAGE F.P. FIRE PROOF(ED)QNG) STRUC. STRUCTURAL FPSC FIRE PROOF SELF CLOSING SUSP. SUSPENDED F.SP. FIRE STANDPIPE SYM. SYMMETRICAL FT. FOOT,FEET SYS. SYSTEM FURN. FURNISH(ED) T. TREAD FURR. FURRMG, FURRED T.B.D, TO BE DETERMINED GA. GAUGE TEL. TELEPHONE GALV. GALVANIZED TEMP. TEMPOR4RY,TEMPERED G.C. GENERALCONTRACTOR THK. THICK(NESS) GL GLASS, GLAZING THR. THRESHOLD GRND. GROUND TLT. TOILET GYP.BD. GYPSUM BOARD TOL TOLERANCE GWB GYPSUM WALLBOARD T.O.S. TOP OF SLAB H. HIGH T.O.STL. TOP OF STEEL HC HANDICAPPED T.O.W. TOP OF WALL H.D. HEAVY DUN TYP TYPICAL HDR. HEADER U.O.N. UNLESS OTHERWISE NOTED HDWR. HARDWARE UIS UNDERSIDE H.M. HOLLOW METAL VAR. VARIES HORIZ. HORIZONTAL V. BAR. VAPOR BARRIER H.P. HIGHPOINT V.C.L VINYLCOMPOSITETILE HT. HEIGHT VENT. VENTILATION HVAC HEATINGNENTILATING VERT. VERTICAL IAIR CONDITIONING VEST. VESTIBULE IN. WCHES V.I.F. VERIFY IN FIELD L LENGTH,LINEAR V7. VINYLTILE LAM. LAMINATE(ED) GRAPHIC SYMBOLS: Xx BUIL�ING ELEVATION REFERENCE n-xxx 00 0o ao INTERIOR ELEVATION REFERENCE 00 A-XXX xx SECTION REFERENCE A-XHX xx DETAIL REFERENCE A-XXX �AxxX • � DETAILCALLOUTREFERENCE RELEA5E0 FOR CONSTRUCTION i�, Suhjec��ocompliancewithallregula�ions 'ERLINE 04 S�a�e antl Local Codes -„� CityofCarmel y „� y,:,�, ',! ,�;va�1_ DATE: 06��4�20 ZZ �REVISION �f � F�ooa�eve� FINISH FLOOR LEVEL REFERENCE z3a,o. - F�ooe �eve� FLOOR SLAB LEVEL REFERENCE z3a-o XX'-XX" SPOT ELEVATION (TOP OF FINISHED FLOOR) �xx�� XX SPOT ELEVATION (TOP OF SL4B) N xx-xx^ exx'-h xx SPOTCOORDINATE `r y WP {r> WORKPOINT N � NORTHARROW xra O x«ra« NAME mo AREA NAME 100 WALL BASE FiooR x-X, AFF xx DOORTAG FURNITURETAG FURNITURESYSTEM TAG SPECIALTY EQUIPMENT TAG KEYNOTETAG ROOM TAG ROOM FINISH TAG CEILING TAG PARTITION TAG D PLUMBING COUNTS: TABLE 721.1 �. MINIMUM NUMBER OF REQUIRED PLUMBING FI%TURES BUSINE55 B pOFPERSON WATERCLOSETS IAVATORIES O OFFACHSEX MALE FEMALE MALE FEMALE 115 1 1 1 1 is�ea nooi nooi ADDO n000 OVER50 ADD� A��1 ADD1 ADD1 �RINKMGWATER OTHER FAQLITIES 1 PER f00 1 SERVICE SINK � PROJECT PLUMBING COUNTS: BUFSINESSGROUP 'NATERCLOSET LAVATORY ".. Sgo� RE�UIRED PROVI�ED DELTA RE�UIREO PROVIDED DEL MALE 3 3 0 2 2 C �ot56�i=18��� ]8°EP�` FEMALE 3 3 0 2 3 + I I� I� I� I� I� TYPICAL MOUNTING HEIGHTS: FlNISHED CEILING NOTE: ALL LOCATIONS AN� MOUNTING HEIGHTS ARE TYPICAL. PLANS ELEVATIONS AN� �ETAILS MAY SHOW VARIATIONS FOR SPEQFIC coN�iiioNs. F A. z � SPEAKEPoSTROB V E DEVICE -- - -- _ � PULLI BREAK I � ALIGN DEVICES WHERE z 4 GLASS I� POSSIBLE o a STATION (TO I \ p aE�ocnrEo � m � p o WITHINSFTOF m � FIREE%TINGUISHER � � - �OOR) n aa CABMETORFlRE m J E%TINGUISHER II - ¢ m A 6 U �I - / II �I� 6/ I O �' K > � I K m Q o� o e a z II �� o G �i I' � m > V ¢ � m i � o o x qd N w �o i �, w o� w� o � z o w o o �� o d oF " � k v�i � '� m � o � � � � ' � z -_ � e � w e _ � p � FimsnEo F�ooa NPICAL MOUNTING HEIGHTS FOR FIRE ALARM DEVICES AND EQUIPMENT LOCATE6"ABOVE COUNTERTOP OR 2" ABOVE BACKSPLASH. WHENSHOWNUN�ER COUNTER,SEEPLANSOR ELEVATIONS PoR MOUNTING HEIGHT GROMMET(SEEPLANS/ - DETAILS) � FwisHeocewNc NOTE: ALL LOCATIONS AND MOUNTING HEIGHTS ARE TYPICAL o PLANS. ELEVATIONS AN� �ETAILS MAY SHOW VARIATIONS FOR SPECIFIC conoiTioNs o � <� zo � oF � �a 0o F N o ¢ a z w w �z � w a �� a a oui�eis, swiicHes. o � o z F DIMMERS, CONTROLS, AND Q a � a r OTHER�EVICESINCWSTER FQ � w �Q � (SEE PLAN FOR �UANTIN OF o� o 0 0 3 EACHCWSTER�. MODEM O � w � m � � z o - o - � o � N a P o � � U � � Q q o FINISHED FLOOR MISCELLANEOUS E�UIPMENT MOUNTING HEIGHTS Y Ea C I B I PROJECT DESCRIPTION: SHEET LIST: PROJECT LOCATION�. 17717 NORTH MERIDIAN STREET qTV OF CARME anvrowNswP,HnMi�TONcouNTv,iNasoaz SHEETNO. SHEETNAME PROJECT�ESCRIPTION'. INTERIORALTERATION 1PARTIALFLOOR. ( ) APPLICABLE CODES�. INDIANA BUILDING CODE:6]5-IAC-131BC IN�IANA BUIL�ING REHABILITATION STANDAR�'. BISIAC �2A INDIANA PLUMBING CODE 2012 IN�IANA ELECTRICAL GO�E:615-IAC4] IEC INDIANA MECHANICAL CO�H fi]5-IAC-0] IEC PARCELIO 29�0435000-037.002-018 PROPERiV 449(COMMERCIAL) CLASSIFICATION: LOTSRE 34543�Sp.FT. CONSTRUCTION I TVPE IB CLASSIFICATION: TOTALpOFFL00R5�. BFLOORS FLOORAREA: LEVEL8=�5,012SQFL(GROSS) OCCUPANCVNPE: BUSWESS6ROUPB(BUSWESSVSE) G-001 GENERAL NOTES, ABBREVIATIONS, SHEET INDEX. AND PROJECT DESCRIPTION G-011 ADAREQUIREMENTS(REFERENCE) G-012 ADAREQUIREMENTS(REFERENCE) G-100 LIFE SAFTEY PLAN G-500 PARTITION SCHEDULES & DETAILS G-600 DOORSCHEDULE G-900 FINISH, TOILET, EQUIPMENT, AND ACCESSORYSCHEDULES A-100 FLOOR PLAN A-200 REFLECTED CEILING PLAN A-300 POWER PLAN A-000 FINISH PLAN A-600 ENLARGED PLANSIELEVATIONS BY PROGRAM A-710 WALL & TR4NSITION DETAILS r+oTe:nu�ocnnoNs A-720 CEILINGDETAILS AN� MOUNTING HeicHTsnae A-730 CASEWORKIMILLWORKDETAILS TVPICAL. PLANS,ELEVATIONS � wn�� nNo oernas Mnv A-800 FURNITURE PLAN (FOR REFERENCE ONL SHOW VARIATIONS X FORSPECIRC 8" CONDITIONS. X COLUMN x E� EQ � x 000a x 8 TYPICAL PLAN LOCATION FOR ALL EQUIPMENT DEVICES, AND OUTLETS AT WALLS. COLUMNS. �OORS w� � a n W o � $ � {� 0 o W z � � � o p � LL < a � o eui�T-iNcouNTERORCREOENu � FURNITURE COUNTER OR CRE�ENZA TYPICAL LOCATIONS FOR POWERIDATA AT COUNTERS. WALLS. AND FEEDS NOTE: ALL LOCATIONS AN� MOUNTING HEIGHTS ARE TVPICAL PLANS. ELEVATIONS AND DETAILS MAY SHOW VARIATIONS PoR SPEQFlC CONDITIONS. STROBE 8" ORSPEAKEPoSTROBE NON�A�JUSTABLE THERMOSTAT OR CO2 SENSOR SEE PLANS AND ELEVATIONS FOR PROJECT SPECIFIC �EVICE MOUNTING HEIGHTS LIGHT SWITCH, DIMMERS, A�JUSTABLE THERMOSTAT, EGRESSBUTTON,INTERCOM BUTTON.CARDREADER, a ETG CLUSTER (SEE PLAN � PoRQUANTITYOFEACH � � � FwisnEocEwNc EXIT SIGN EXIT1 CEILINGMOUNTE�TYPICALUDN 2 WALL MOONT fi" BELOW CEILING �cooRoinnrE wiTH 000a scHEou�E EQ EQ AN�LOCATIONS) `��000R GOAT HOOK � CLUSTER) � �' J - m Q e � � w a w o o = aowER. voicEionTn nNo AV OUTLETS w STRIKE " HINGE SIDE SIDE FINISHE� FLOOR TYPICAL LOCATIONS FOR DEVICES AROUND DOORS I_1 J� �vE R Es� EVEREST - CARMEL, IN 11711 NORTH MERIDIAN STREET CITY OF CARMEL, CLAY TOWNSHIP HAMILTON COUNTY, IN 46032 EVERESTREINSURANCEIINSURANCE iP11 NORTH MERIDIAN STREET CARMEL, IN 46032 r�cxrtEcr hlw 5 PENN PLAZA STH FLOOR, NEW VORK. NY 10001 APPLIED ENGINEERING SERVICES, INC. 5975 CASTLE CREEK PARKWAV N DRNE. SUITE 300 IN�IANAPOLIS, IN 66250 r.�av�raai ��0 SIGNATURE J����\�N`?I fGE ������i �. o,. • ••.Ri '% \� � ���,ISTc�pF ;y�i %i �/�' o. �t i��'�/!'+7 � '. STATE OF • � ��ii '•�vUTAN?'.•� \�� i��//qRCH ITEG,�\\\\��� NOT FOR CONSTUCTION 419I2020 I ISSUE FOR PERMIT DATE ISSUE OR F GENERAL NOTES, ABBREVIATIONS, SHEET INDEX, AND PROJECT DESCRIPTION Asintlicated 4I9I2020 '. pABY'. PROJECTNO. MM SH 19257 ING N0. G-001 � � x�w ���,�a�o�,� �