HomeMy WebLinkAboutM001� � � J 2 1 H i G i F i E i � C i 0 i 0 NOTE: ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION ON THE DRAWINGS. ALL SYMBOLS NOT NECESSARILY USED ON THIS PROJECT. VALVES & FITTINGS: GENERAL SYMBOLS: DUCTWORK: DUCTWORK: SINGLE LINE REPRESENTATION: S—�—p�i GATEVAWE � POINTOFCONNECTION _� Y SUPPLVARROW � SUPPLVUP IW s--�j--S BALLVALVE � POINTOFREMOVAL w� RETURN/EXHAUSTARROW �i f�i BUTTERFLV VALVE �� SUPPLV OOWN Q THERMOSTAT s—�\�S CHECKVALVE OO PLANNOTE Q HUMIDISTAT 1�� RETURN/EXHAUSTUP I� S--p�i GLOBE VALVE �1 DEMOLITION NOTE Q SENSOR S--�R�I--S BALANCINGVALVE �� RETURWEXHAUSTDOWN Qi REVISION � SUPPLY UP /� 5�5 PWGVALVE ��I ROUNDUP A `� Q M501 DETAILBUBBLE SUPPLVDOWN f--�--5 CONTROLVAWE �� ROUNDDOWN 0 1 � � u RETURN/EXHAUST UP 5���. SOLENOIDVALVE MSQ� SECTIONBUBBLE � OVALSUPPLVUP s-�yJC�s NEEDLEVALVE � RETURNIEXHAUSTDOWN �� OVALSUPPLVDOWN I� � THERMAL EXPANSION VALVE /�TT� RECTANGULAR DUCT A�TOMAT��F�oW�oNTRo� PIPING DESIGNATIONS: rl lI ROUN�UP ~76x7z� WIDTHxHEIGHT � VALVE �� NEWPIPING � ROUNDDOWN ��6��0� pOMEDORCT � BACKROWPREVENTER EXISTING PIPWG TO REMAIN � FLAT OVAL DUCT FLATOVAL SUPPLV UP �i6x120� pyIDTH x HEIGHT �J PRESSUftE RE�UCING, f---------K EXISTING PIPWG TO BE REMOVED 5--�'�i SELFCONTAWEDVALVE � t ti EXISTINGDUCT �� SANITARV � PRESSURE REDUQNG, FLATOVAL SUPPLY DOWN PILOTOPERATEDVALVE 'r----K SANITARVVENT � RECTANGULARDUCT DUCTTURN9�� � �—� POTABLECOLDWATER 16x12 WIDTHxHEIGHT RELIEF, PILOT OPERATED VALVE �--� pOTABLEHOTWATER(TEMPERATUREASNOTED) '�7 DUCTENDCAP �g„� ROUNDDUCT � �---� HOTWATERRETURN DIAMETER DUCTTRANSITION- ANGLE GLOBE VALVE '�� � SLOPED ON BOTH SIDES �T� PIPE SLOPES IN DIRECTION OF ARROW 16x12� RAT OVAL DUCT WIDTHxHEIGHT �� DUCTTRANSITION- � FLAT ON ONE SIOE PRESSURE RELIEF, ANGLETVPEVALVE EXISTWGDUCT '�'�^� FLE%IBLEOUCT 5—�—�--5 THREE WAV BALL VALVE DIFFUSERS & REGISTERS � �--F� "°�"""EB"�A"°E°"""PER � 9�° MITERED ELBOW WITH � TURNING VANES SUPPLV DIFFUSER'. SUPPLV �IFFUSER: �� �� FIRE OAMPER 5--�-5 THREEWAVGLOBEVALVE SHADIN6INDICATESBLANKED-0FF SHADINGINDICATESBLANKED-0FF y pUADRANTOFDIFFUSIONPATTERN QUAORANTOFDIFFUSIONPATTERN w SEESCHEDULEFOR SEESCHEDULEFOR r"'� ,�� MOTORREDDAMPER """ ������, """ RUNOUT SIZE RUNOUT SRE � THREE WAV PLUG VALVE Q=w) DIFFUSER TVPE �IFFUSER TVPE ELBOW �DIFFUSERSIZE �DIFFUSERSRE ��� BACKDRAFTDAMPER � � r THREE WAV CONTROL VALVE SD-4 SD-0 ]5� �-DIFFUSERCFM �50 �-OIFFUSERCFM � DUCT END CAP '+-� RETURN/EXHAUST GRILLE: RETURN/EXHAl15T GRILLE: 1--� � PIPETURN90° SEESCHEDULEFOR SEESCHEDULEFOR RUNOUT SIZE RUNOUT SIZE 15° MAX � LWEBREAK GRILLETVPE GRILLETVPE GRILLE SIZE GPoLLE SIZE DUCT TRANSITION - �s PIPE ELBOW UP (RISER) � / SLOPED BOTH SIDES � 15° MAX �� PIPEELBOWDOWN RSp3f—GRILLECFM RQ3�—GRILLECFM DUCT TRANSITION - f--ri PIPE TEE DOWN FLAT ON ONE SIDE LW EAR BAR 8 SLOT DIFFUSER: LMEAR BAR 8 SLOT DIFFUSER: �� CAP OR PLUG ARROW INDICATES ARROW INDICATES DIRECTIONOFAIRFLOW DIRECTIONOFAIRFLOW ^/� S--o—� REDUCER, CONCENTRIC SEESCHEDULEFOR /SEESCHEDULEFOR � I I� FLEXIBLE DUCT f-�-�i RE�UCER,ECCENTRIC RUNOUTSIZE —n / RUNOl1TSIZE DIFFUSERTVPE II}•Wp/w pIFFIISERTYPE II�-----�FF--���--11 �� V-STRAWER �DIFFUSERSIZE LI /�OIFFUSERSRE 1T II�T VOLUMEDAMPER � ��S '�� �4 '����5 S = . S * . � 0 0 � RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel r �un��V l�rcNalM�� DATE: 06�04�20 FLEXIBLE CONNECTION FLANGES UNION PIPE GUIDE PIPE ANCHOR FlLTER (INLINE) GAUGE THERMOMETER STEAM TRAP PRESSURESENSOR INLINE PUMP LD-6 LD-6 zZ0 ��DIFFUSERCFM 220 _��IFFUSERCFM TERMINAL BOXES SINGLE-DUCT TERMINAL BOX DUAL DUCT TERMINAL BOX: ( W ITH REHEAT COIL) SEESCHEDULE SEESCHEDULE �i �i FORRUNOUTSIZE FORRUNOUTSRE i i � TYPE OF TERMINAL BOX VAV-0 l TVPE OF TERMINAL BOX i �CONTROLPANEL i VAV-0 `\ CONTROL PANEL(S) `MAINTAW CODE RE�UIRED I `I\ QEARANCE M FRONT OF `MAINTAIN CODE REQUIRED CONTROLPANEL CLEARANCEINFRONTOF CONTROLPANEL FO � FIRE DAMPER � � MOTORIZED DAMPER i BDD �BACKDRAFT DAMPER i (]A� ACCESSDOOR MECHANICAL ABBREVIATIONS: ADA AMERICANSWITHDISABILITIESACT AFF ABOVE FINISHED FLOOR AFG ABOVEFINISHEDGRADE AHU AIRHANOLINGUNIT AD ACCESSDOOR BDD BACKORAFTDAMPER BHP BRAKEHORSEPOWER BLDG BUIL�ING BOD BOTTOM OFDUCT BOS BOTTOM OFSTEEL BTII BRITISHTHERMALIINIT CA COMPRESSEDAIR CD CONDENSATE DRAIN CHWR CHILLEDWATERRETURN CHWS CHILLED WATER SUPPLV W CLEANOUT CR CONDENSATERETURN CS CASTSINK CSS CLINICSERVICESINK CW DOMESTIC COLD WATER DB DRVBULB DCV DOUBLE CHECK VALVE DIA DIAMETER DN DOWN DWH DOMESTIC WATER HEATER EES EMERGENCV EVE ANO SHOWER WASH EEW EMERGENCV EVE WASH EF EXHAUSTFAN EG E%HAUSTGRILLE EL ELEVATION ES EMERGENCVSHOWER EXIST EXISTING GL GLVCOL FCU FANCOILUNIT FD FIRE DAMPER OR FLOOR DRAIN FDC FIREDEPARTMENTCONNECTION FLA FULL LOAD AMPS FOB FLATONBOTTOM FOT FLAT ON TOP HB HOSE BIBB HKSP HOUSEKEEPWG HPR HIGH PRESSURE STEAM RETURN HPS HIGHPRESSURESTEAMSUPPLV HW DOMESTIC HOT WATER HWR DOMESTIC HOT WATER RETURN HWRP HOTWATERRECIRCULATIONPUMP HHWR HEATING HOT WATER RETURN HHWS HEATINGHOTWATERSUPPLV IE INVERTELEVATION JS JANITORSINK JT JOINT LAV LAVATORY LPR LOW PRESSURE STEAM RETURN LPS LOW PRESSURE STEAM SUPPLV MB MOP BASIN MF MIXING FAUCET MPR MEDIUM PRESSURE STEAM RETURN MPS MEDIUM PRESSURE STEAM SUPPLV NC NORMALLYCLOSED NO NORMALLYOPEN PIV POST INDICATING VALVE PRV PRESSURE RELIEF VALVE PSIA POUNDS PER SQUARE INCH ABSOLUTE PSIG POUNDS PER SQUARE INCH GAUGE RF RETURN FAN RG RETURNGRILLE RO REVERSEOSMOSIS RPBP REDUCED PRESSURE BACKFLOW PREVENTER SAN SANITARV SD SUPPLV DIFFl15ER SF SUPPLV FAN SG SUPPLV GRILLE SH SHOWER 51 SEDIMENTINTERCEPTOR SK SINK STM STEAM T� TRENCH DRAIN TMV THERMOSTATIC MIXING VALVE TSP TOTAL STATIC PRESSURE V SANITARV VENT VD VOLUMEDAMPER VFD VARIABLE FREQUENCV DRNE VTR VENTTHROUGHROOF WB WETBULB WC WATERCLOSET WH WALLHVDRANT GENERAL NOTES: 1. ALL WORK MUST COMPLY WITH CURRENT MECHANICAL CODE. 2 CONTRACTOR TO COORDINATE WITH ALL TRADES TO INSTALL AND MAINTAIN SYSTEMS WITH CLEARANCE FOR SERVICE AND MAINTENANCE. 3. REPORT DISCREPANCIES BERNEEN DRAWINGS AND EXISTING CONDITIONS TO ENGMEER PRIOR TO FABRICATING ANY DUCTWORK, PIPMG, OR MECHAMCAL ASSEMBLIES. 4. PROPERLY SUSPEND ALL EQUIPMENT, DUCTWORK, PIPING, DEVICES, TRANSFER DUCTS, EfC FROM STRUCTURE. 5. BUILDING IS TO REMAIN OCCUPIED AND FUNCTIONAL THROUGHOUT CONSTRUCTION PERIOD. COORDINATE ALL DISRUPTIONS IN WORKING ARFAS WITH OWNER'S DESIGNATED REPRESENTATNE PRIOR TO COMMENCING. OFF HOURS WORK MAY BE RE�UIRED W SOME INSTANCES. 6. CONTRACTOR SHALL FOLLOW ALL OF THE OWNER'S SAFETY PROTOCOLS AND GUIDELMES. 7. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL SYSTEM SHUTDOWNS WITH OWNER MINIMUM 5 WORKING DAYS PRIOR. 8. CONTRACTOR IS RESPONSIBLE FOR ALL CUTfMG AND PATCHMG OF FLOORS, WALLS, AND CEILINGS. PATCH ALL ARFAS WHERE DEVICES OR SERVICES HAVE BEEN REMOVED AND ANY NEW OPENWGS TO MATCH EXISTING SURFACES AND AS REQUIRED TO ACCEPT NEW FlNISH. 9. CONTRACTOR SHALL FURNISH ALL TOOLS, MATERIALS, AN� EQUIPMENT NECESSARY TO COMPLETE THE CONTRACT. CONTRACTOR SHALL NOT USE OWNER"S E�UIPMENT OR TOOLS MCWDING LADDERS OR SCAFFOLDS. CONTRACTOR SHALL COORDINATE STORAGE, LAYDOWN AREAS, AND WORKING ARFAS WITH OWNER'S DESIGNATED REPRESENTATNE TO AVOID IMPEDING THE OWNER'S WORK. 10. NEW EQUIPMENT SHALL REMAIN THE RESPONSIBILIiV OF THE CONTRACTOR UNTIL SUBSTANTIAL COMPLETION. CONTRACTOR SHALL MAINTAW EQUIPMENT IN GOOD WORKING ORDER THROUGHOUT CONSTRUCTION. FlLTERS, STRAMERS, ETC SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR DURING THIS PERIOD. EQUIPMENT SHALL BE TURNED OVER TO OWNER IN CLEAN, FULLY FUNCTIONAL CONDITION WITH NEW OR CLEANE� RLTERS. ATTIC STOCK MATERIALS, INCLUDING FlLTERS, TO BE PROVIDE� TO OWNER AT PROJECT TURNOVER. i 1"F �vE R Es�. cuc�i EVERESTREINSURANCEIINSURANCE 11I11 NORTH MERI�IAN STREET CARMEL IN 46032 5 PENN PLAZA, STH FLOOR. NEW YORK, NV 10001 � � Appl ied Engineering Services 5975CastleCreekParkwayNDrive,5uite3W • Indianapolis,Indiana46250 TeP, 317.8ID.4141 • FaX:317.810.414� • www.applied-e-s.mm 13Y19C1J SIGNATIIRE 5T SiATE OF 4�24�2020 r�0 MECHANICAL SYMBOLS AND ABBREVIATIONS MM I SH M-001 a