NOTE: ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION ON THE DRAWINGS. ALL SYMBOLS NOT NECESSARILY USED ON THIS PROJECT.
VALVES & FITTINGS: GENERAL SYMBOLS: DUCTWORK: DUCTWORK:
SINGLE LINE REPRESENTATION:
S—�—p�i GATEVAWE � POINTOFCONNECTION _�
Y SUPPLVARROW � SUPPLVUP
IW
s--�j--S BALLVALVE �
POINTOFREMOVAL w� RETURN/EXHAUSTARROW
�i f�i BUTTERFLV VALVE �� SUPPLV OOWN
Q THERMOSTAT
s—�\�S CHECKVALVE OO PLANNOTE Q HUMIDISTAT 1�� RETURN/EXHAUSTUP
I�
S--p�i GLOBE VALVE �1 DEMOLITION NOTE Q SENSOR
S--�R�I--S BALANCINGVALVE �� RETURWEXHAUSTDOWN
Qi REVISION � SUPPLY UP /�
5�5 PWGVALVE ��I ROUNDUP
A `�
Q M501 DETAILBUBBLE SUPPLVDOWN
f--�--5 CONTROLVAWE �� ROUNDDOWN
0 1 � � u RETURN/EXHAUST UP
5���. SOLENOIDVALVE MSQ� SECTIONBUBBLE � OVALSUPPLVUP
s-�yJC�s NEEDLEVALVE � RETURNIEXHAUSTDOWN �� OVALSUPPLVDOWN
I�
� THERMAL EXPANSION VALVE /�TT� RECTANGULAR DUCT
A�TOMAT��F�oW�oNTRo� PIPING DESIGNATIONS: rl lI ROUN�UP ~76x7z� WIDTHxHEIGHT
� VALVE
�� NEWPIPING � ROUNDDOWN ��6��0� pOMEDORCT
� BACKROWPREVENTER
EXISTING PIPWG TO REMAIN � FLAT OVAL DUCT
FLATOVAL SUPPLV UP �i6x120� pyIDTH x HEIGHT
�J PRESSUftE RE�UCING, f---------K EXISTING PIPWG TO BE REMOVED
5--�'�i SELFCONTAWEDVALVE � t ti EXISTINGDUCT
�� SANITARV
� PRESSURE REDUQNG, FLATOVAL SUPPLY DOWN
PILOTOPERATEDVALVE 'r----K SANITARVVENT �
RECTANGULARDUCT DUCTTURN9��
� �—� POTABLECOLDWATER 16x12 WIDTHxHEIGHT
RELIEF, PILOT OPERATED
VALVE �--� pOTABLEHOTWATER(TEMPERATUREASNOTED) '�7 DUCTENDCAP
�g„� ROUNDDUCT
� �---� HOTWATERRETURN DIAMETER DUCTTRANSITION-
ANGLE GLOBE VALVE '��
� SLOPED ON BOTH SIDES
�T� PIPE SLOPES IN DIRECTION OF ARROW 16x12� RAT OVAL DUCT
WIDTHxHEIGHT �� DUCTTRANSITION-
� FLAT ON ONE SIOE
PRESSURE RELIEF,
ANGLETVPEVALVE EXISTWGDUCT '�'�^� FLE%IBLEOUCT
5—�—�--5 THREE WAV BALL VALVE
DIFFUSERS & REGISTERS � �--F� "°�"""EB"�A"°E°"""PER
� 9�° MITERED ELBOW WITH
� TURNING VANES
SUPPLV DIFFUSER'. SUPPLV �IFFUSER: �� �� FIRE OAMPER
5--�-5 THREEWAVGLOBEVALVE SHADIN6INDICATESBLANKED-0FF SHADINGINDICATESBLANKED-0FF
y pUADRANTOFDIFFUSIONPATTERN QUAORANTOFDIFFUSIONPATTERN w
SEESCHEDULEFOR SEESCHEDULEFOR r"'� ,�� MOTORREDDAMPER
""" ������, """ RUNOUT SIZE RUNOUT SRE
� THREE WAV PLUG VALVE Q=w)
DIFFUSER TVPE �IFFUSER TVPE ELBOW
�DIFFUSERSIZE �DIFFUSERSRE ��� BACKDRAFTDAMPER
� � r
THREE WAV CONTROL VALVE SD-4 SD-0
]5� �-DIFFUSERCFM �50 �-OIFFUSERCFM
� DUCT END CAP
'+-� RETURN/EXHAUST GRILLE: RETURN/EXHAl15T GRILLE: 1--�
� PIPETURN90°
SEESCHEDULEFOR SEESCHEDULEFOR
RUNOUT SIZE RUNOUT SIZE 15° MAX
� LWEBREAK GRILLETVPE GRILLETVPE
GRILLE SIZE GPoLLE SIZE DUCT TRANSITION -
�s PIPE ELBOW UP (RISER) � / SLOPED BOTH SIDES
� 15° MAX
�� PIPEELBOWDOWN RSp3f—GRILLECFM RQ3�—GRILLECFM
DUCT TRANSITION -
f--ri PIPE TEE DOWN FLAT ON ONE SIDE
LW EAR BAR 8 SLOT DIFFUSER: LMEAR BAR 8 SLOT DIFFUSER:
�� CAP OR PLUG ARROW INDICATES ARROW INDICATES
DIRECTIONOFAIRFLOW DIRECTIONOFAIRFLOW ^/�
S--o—� REDUCER, CONCENTRIC
SEESCHEDULEFOR /SEESCHEDULEFOR
� I I� FLEXIBLE DUCT
f-�-�i RE�UCER,ECCENTRIC RUNOUTSIZE —n / RUNOl1TSIZE
DIFFUSERTVPE II}•Wp/w pIFFIISERTYPE II�-----�FF--���--11
�� V-STRAWER �DIFFUSERSIZE LI /�OIFFUSERSRE 1T II�T VOLUMEDAMPER
�
��S
'�� �4
'����5
S = .
S * .
�
0
0
�
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
r
�un��V l�rcNalM��
DATE: 06�04�20
FLEXIBLE CONNECTION
FLANGES
UNION
PIPE GUIDE
PIPE ANCHOR
FlLTER (INLINE)
GAUGE
THERMOMETER
STEAM TRAP
PRESSURESENSOR
INLINE PUMP
LD-6 LD-6
zZ0 ��DIFFUSERCFM 220 _��IFFUSERCFM
TERMINAL BOXES
SINGLE-DUCT TERMINAL BOX DUAL DUCT TERMINAL BOX:
( W ITH REHEAT COIL)
SEESCHEDULE SEESCHEDULE �i �i
FORRUNOUTSIZE FORRUNOUTSRE i i
� TYPE OF TERMINAL BOX
VAV-0 l TVPE OF TERMINAL BOX
i �CONTROLPANEL i VAV-0
`\ CONTROL PANEL(S)
`MAINTAW CODE RE�UIRED I `I\
QEARANCE M FRONT OF `MAINTAIN CODE REQUIRED
CONTROLPANEL CLEARANCEINFRONTOF
CONTROLPANEL
FO
� FIRE DAMPER
�
� MOTORIZED DAMPER
i
BDD
�BACKDRAFT DAMPER
i
(]A� ACCESSDOOR
MECHANICAL ABBREVIATIONS:
ADA AMERICANSWITHDISABILITIESACT
AFF ABOVE FINISHED FLOOR
AFG ABOVEFINISHEDGRADE
AHU AIRHANOLINGUNIT
AD ACCESSDOOR
BDD BACKORAFTDAMPER
BHP BRAKEHORSEPOWER
BLDG BUIL�ING
BOD BOTTOM OFDUCT
BOS BOTTOM OFSTEEL
BTII BRITISHTHERMALIINIT
CA COMPRESSEDAIR
CD CONDENSATE DRAIN
CHWR CHILLEDWATERRETURN
CHWS CHILLED WATER SUPPLV
W CLEANOUT
CR CONDENSATERETURN
CS CASTSINK
CSS CLINICSERVICESINK
CW DOMESTIC COLD WATER
DB DRVBULB
DCV DOUBLE CHECK VALVE
DIA DIAMETER
DN DOWN
DWH DOMESTIC WATER HEATER
EES EMERGENCV EVE ANO SHOWER WASH
EEW EMERGENCV EVE WASH
EF EXHAUSTFAN
EG E%HAUSTGRILLE
EL ELEVATION
ES EMERGENCVSHOWER
EXIST EXISTING
GL GLVCOL
FCU FANCOILUNIT
FD FIRE DAMPER OR FLOOR DRAIN
FDC FIREDEPARTMENTCONNECTION
FLA FULL LOAD AMPS
FOB FLATONBOTTOM
FOT FLAT ON TOP
HB HOSE BIBB
HKSP HOUSEKEEPWG
HPR HIGH PRESSURE STEAM RETURN
HPS HIGHPRESSURESTEAMSUPPLV
HW DOMESTIC HOT WATER
HWR DOMESTIC HOT WATER RETURN
HWRP HOTWATERRECIRCULATIONPUMP
HHWR HEATING HOT WATER RETURN
HHWS HEATINGHOTWATERSUPPLV
IE INVERTELEVATION
JS JANITORSINK
JT JOINT
LAV LAVATORY
LPR LOW PRESSURE STEAM RETURN
LPS LOW PRESSURE STEAM SUPPLV
MB MOP BASIN
MF MIXING FAUCET
MPR MEDIUM PRESSURE STEAM RETURN
MPS MEDIUM PRESSURE STEAM SUPPLV
NC NORMALLYCLOSED
NO NORMALLYOPEN
PIV POST INDICATING VALVE
PRV PRESSURE RELIEF VALVE
PSIA POUNDS PER SQUARE INCH ABSOLUTE
PSIG POUNDS PER SQUARE INCH GAUGE
RF RETURN FAN
RG RETURNGRILLE
RO REVERSEOSMOSIS
RPBP REDUCED PRESSURE BACKFLOW PREVENTER
SAN SANITARV
SD SUPPLV DIFFl15ER
SF SUPPLV FAN
SG SUPPLV GRILLE
SH SHOWER
51 SEDIMENTINTERCEPTOR
SK SINK
STM STEAM
T� TRENCH DRAIN
TMV THERMOSTATIC MIXING VALVE
TSP TOTAL STATIC PRESSURE
V SANITARV VENT
VD VOLUMEDAMPER
VFD VARIABLE FREQUENCV DRNE
VTR VENTTHROUGHROOF
WB WETBULB
WC WATERCLOSET
WH WALLHVDRANT
GENERAL NOTES:
1. ALL WORK MUST COMPLY WITH CURRENT MECHANICAL CODE.
2 CONTRACTOR TO COORDINATE WITH ALL TRADES TO INSTALL AND MAINTAIN
SYSTEMS WITH CLEARANCE FOR SERVICE AND MAINTENANCE.
3. REPORT DISCREPANCIES BERNEEN DRAWINGS AND EXISTING CONDITIONS TO
ENGMEER PRIOR TO FABRICATING ANY DUCTWORK, PIPMG, OR MECHAMCAL
ASSEMBLIES.
4. PROPERLY SUSPEND ALL EQUIPMENT, DUCTWORK, PIPING, DEVICES,
TRANSFER DUCTS, EfC FROM STRUCTURE.
5. BUILDING IS TO REMAIN OCCUPIED AND FUNCTIONAL THROUGHOUT
CONSTRUCTION PERIOD. COORDINATE ALL DISRUPTIONS IN WORKING
ARFAS WITH OWNER'S DESIGNATED REPRESENTATNE PRIOR TO
COMMENCING. OFF HOURS WORK MAY BE RE�UIRED W SOME INSTANCES.
6. CONTRACTOR SHALL FOLLOW ALL OF THE OWNER'S SAFETY PROTOCOLS
AND GUIDELMES.
7. CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL SYSTEM SHUTDOWNS
WITH OWNER MINIMUM 5 WORKING DAYS PRIOR.
8. CONTRACTOR IS RESPONSIBLE FOR ALL CUTfMG AND PATCHMG OF
FLOORS, WALLS, AND CEILINGS. PATCH ALL ARFAS WHERE DEVICES
OR SERVICES HAVE BEEN REMOVED AND ANY NEW OPENWGS TO MATCH
EXISTING SURFACES AND AS REQUIRED TO ACCEPT NEW FlNISH.
9. CONTRACTOR SHALL FURNISH ALL TOOLS, MATERIALS, AN� EQUIPMENT
NECESSARY TO COMPLETE THE CONTRACT. CONTRACTOR SHALL NOT USE
OWNER"S E�UIPMENT OR TOOLS MCWDING LADDERS OR SCAFFOLDS.
CONTRACTOR SHALL COORDINATE STORAGE, LAYDOWN AREAS, AND WORKING
ARFAS WITH OWNER'S DESIGNATED REPRESENTATNE TO AVOID IMPEDING
THE OWNER'S WORK.
10. NEW EQUIPMENT SHALL REMAIN THE RESPONSIBILIiV OF THE CONTRACTOR
UNTIL SUBSTANTIAL COMPLETION. CONTRACTOR SHALL MAINTAW EQUIPMENT
IN GOOD WORKING ORDER THROUGHOUT CONSTRUCTION. FlLTERS,
STRAMERS, ETC SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
DURING THIS PERIOD. EQUIPMENT SHALL BE TURNED OVER TO OWNER IN
CLEAN, FULLY FUNCTIONAL CONDITION WITH NEW OR CLEANE� RLTERS.
ATTIC STOCK MATERIALS, INCLUDING FlLTERS, TO BE PROVIDE� TO OWNER
AT PROJECT TURNOVER.
i
1"F
�vE R Es�.
cuc�i
EVERESTREINSURANCEIINSURANCE
11I11 NORTH MERI�IAN STREET
CARMEL IN 46032
5 PENN PLAZA, STH FLOOR. NEW YORK, NV 10001
� �
Appl ied
Engineering Services
5975CastleCreekParkwayNDrive,5uite3W • Indianapolis,Indiana46250
TeP, 317.8ID.4141 • FaX:317.810.414� • www.applied-e-s.mm
13Y19C1J
SIGNATIIRE
5T
SiATE OF
4�24�2020
r�0
MECHANICAL SYMBOLS
AND ABBREVIATIONS
MM I SH
M-001
a