Loading...
HomeMy WebLinkAboutP001� � � 3 2 1 H G I F I E I D I C I NOTE: ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION ON THE DRAWINGS. ALL SYMBOLS NOT NECESSARILY USED ON THIS PROJECT. GENERAL SYMBOLS: PIPING DESIGNATIONS: PLUMBING ABBREVIATIONS: ih POINTOF CONNECTION �� NEW PIPING AFF ABOVE FlNISHED ROOR Y }, s EXISTINGPIPINGTOREMAIN AFG ABOVEFINISHEDGRADE �..` POINT OF REMOVAL AHU AIR HANDLING UNIT Y F i EXISTING PIPING TO BE REMOVED AD ACCESSDOOR Oi PLAN NOTE �� PIPE SLOPES IN DIRECTION OF ARROW AV ACID VENT AW ACID WASTE �---. DOMESTICCOLDWATER �1 DEMOLITION NOTE BDD BACK DRAFT DAMPER �--� DOMESTICHOTWATER BHP BRAKEHORSEPOWER 1� REVISION �----. DOMESTICHOTWATERRETURN BLDG BUILDWG BOD BOTTOM OF DUCT �----140�F—f DOMESTICHOTWATER140`F BOP BOTTOMOFPIPE A �ETAIL BUBBLE BOS BOTTOM OF STEEL MWi �----140�F—f DOMESTICHOTWATER140`FRETURN BTU BRITISHTHERMALUNIT S W� WASTEPIPING CO QEANOUT 1 M501 SECTION BUBBLE S ST� STORM PIPING CS CUP SINK CSS CLINICSERVICESINK �--------� SANITARVVENT CW DOMESTIC COLD WATER S D� INDIRECTDRAIN D CONDENSATEIDRAIN DB DRY BULB S AW � ACID WASTE DCV DOUBLECHECKVALVE Y------- AV ----- i AQD VENT DIA DIAMETER VALVES & FITTINGS: s DE� DEIONIZEDWATER DN DOWN DWH DOMESTICWATERHEATER �j GATE VALVE S DI� DISTILLED WATER FD FLOOR DRAIN �j BALL VALVE S RODI—. REVERSE OSMOSIS DEIONRED WATER ESEW EMERGENCV SHOWER AND FACE/EYE WASH EW EMERGENGV EVHFACE WASH '� —I/�—s BUTTERFLVVALVE S LS—. LAWNSPRWKLER EL ELEVATION S G� 6AS ES EMERGENCVSHOWER s—��s CHECK VALVE EXIST EXISTING S F05—. FUEL OIL SUPPLY �j GLOBEVAWE FCO FLOORCLEANOUT S FOR—. FUEL OIL RETURN FLA FULL LOAD AMPS �� VALVE IN VERTICAL PIPE HB HOSE BIBB � S FOV—. FUELOILVENT CONTROLVALVE HKSP HOUSEKEEPING S VAC—. VACUUM HW DOMESTIC HOT WATER � REDUCED PRESSURE BACK FLOW PREVENTER HWR DOMESTIC HOT WATER RETURN �A� COMPRESSEDAIR HWCP HOT WATER RECIRCULATION PUMP � . INDICATED FLOW DIRECTION IE INVERTELEVATION � PIPETURN90° JS JANITORSINK LAV LAVATORV SPECIALTY PIPING MB MOPBAs�N � LINE BREAK �MV� MEDICALVACUUM NC NORMALLVCLOSED �e PIPE ELBOW UP (RISER) NO NORMALLV OPEN �SV� SURGICAL VACUUM PIV POST INDICATING VALVE �� PIPEELBOWDOWN PSIA POUNDSPERSQUAREINCHABSOLUTE �LV� LABVACUUM �� PIPE TEE DOWN PSIG POUN�S PER SQl1ARE INCH GAl1GE �N2� NITROGEN RO REVERSE OSMOSIS �� CAP OR PLUG �N20� NITROUSOXIDE RPBP REDUCEDPRESSUREBACKFLOWPREVENTER � REDUCER, CONCENTRIC SAN SANITARV �CO2� CARBON DIOXIDE `� —��, REDUCER, ECCENTRIC SH SHOWER �AG� ARGON SI SEDIMENTINTERCEPTOR ���� FLANGES SK SINK �MA� MEDICALAIR SS STAINLESSSTEEL ��I�s UNION �LA� LABAIR ST STORM WATER `� —o-� METER TD TRENCH DRAIN V SANITARY VENT �p FO FLOOR DRAIN VTR VENTTHROUGH ROOF FIRE PROTECTION PIPING SYMBOLS W WASTE � GAUGE WC WATERCLOSET S F FIRE PROTECTION 4 WH WALLHV�RANT ❑T 0 � THERMOMETER STEAM TRAP PRESSURE SENSOR INLINE PUMP PA PRE-ACTION F�P FIRE DRV PIPE nun �Y� � TS �I:i� �I:i� CONNECTION (FREE STANDING) CONNECTION (WALL MOUNTED) 0 GENERAL NOTES: 1. VERIFY EXISTING CONOITIONS IN THE FIELD PRIOR TO BUILDING AND BEFORE BEGINNING WORK. 2 REVIEWTHEWORKOFOTHERTRAOES,COOR�INATEAND-PLANWORKWITHTHE OTHER TRADES AND OWNER. ADJUST AS A RESULT OF COORDINATION. 3. STORE EQUIPMENT ANO COMPONENTS IN A CLEAN, DRV LOCATION UNTIL REA�V FOR INSTALLATION. PROTECT FROM WEATHER, OIRT, WATER, AND CONSTRUCTION DEBRIS, ETG AT ALL TIMES. ANV DAMAGED EpUIPMENT OR COMPONENTS SHALL BE RESTORED AS NEW OR REPLACED. 4. ALL MATERIALS REMOVED AND NOT RELOCATED BECOME THE PROPERTV OF THE CONTRACTOR. REMOVE MATERIALS FROM THE PROJECT SITE UNLE55 NOTEO OTHERWISE. 5. PATCH WALLS, FLOORS, CEILINGS, COW MNS, ROOF PENETRATIONS, ETC. WHERE ITEMS ARE REMOVEO TO MATCH AOJACENT SURFACES. 6. DRAWINGS SHOW THE INTENDEO ARRANGEMENT AND ROUTING OF ALL PIPING, EQUIPMENT, AND APPURTENANCES. THEV SHALL BE FOLLOWED AS CLOSELV AS ACTUAL BUILOING CONSTRUCTION AND WORK OF OTHER TRAOES WILL PERMIT. ]. CLEAN ALL EQl11PMENT TO PRESENT A"LIKE NEW" CONOITION AT PROJECT COMPLETION. 8. OFFSET PIPING AROUND ELECTRICAL PANELS TO PROVIDE CLFARANCES AS REpUIRED BV THE NATIONAL ELECTRICAL CODE. FLOW SWITCH ZONE CONTROL VALVE WITH TAMPER SWITCH FIRE PROTECTION GENERAL NOTES: 1. SVSTEM DESIGN IS PER NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SVSTEMS. 2 ALL WORK AND MATERIALS SHALL CONFORM TO NFPA 13, AND STATE RULES AND REGULATIONS. 3. ALL MATERIALS, WHERE APPLICABLE SHALL BE U.L LISTED AND FACTORY MUTUAL APPROVED FOR THE USE IN AUTOMATIC SPRINKLER SVSTEMS. 4. PROVIDEAMINIMUMOF]2HOURNOTICETOTHEOWNERPRIORTOSPRINKLER PIPE TESTING OR LINE PRESSURIZATION. 5. FIRE PROTECTION CONTRACTOR SHALL PREPARE ALL DRAWINGS AND APPLICATIONS REpUIRED TO OBTAIN APPROVAL OF THE SVSTEM BV OWNERS INSURANCE UNDERWRITER, STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. ALL�RAWINGSTOBESUBMITTEDDURINGCONSTRUCTION. 6. FIREPROTECTIONCONTRACTORSHALLSUBMITDRAWINGSWITHALLSPRINKLER HEAD LOCATIONS. ALL SPRINKLER HEADS TO BE LAID OUT NEATLV WITHIN THE CEILWG SVSTEMS AND BE COORDINATED WITH ALL DISCIPLINES, BULKHEADS, CEILWGS AND STRUCTURE. 0 1"F �vE R Es�. cueni EVERESTREINSURANCEIINSURANCE 11I11 NORTH MERI�IAN STREET CARMEL IN 46032 5 PENN PLAZA, STH FLOOR. NEW YORK, NV 10001 � � Appl ied Engineering Services 5975CastleCreekParkwayNDrive,5uite3W • Indianapolis,Indiana46250 TeP, 317.8ID.4141 • FaX:317.810.414� • www.applied-e-s.mm 13Y19C1J SIGNATIIRE 5T SiATE OF 4�24�2020 r�0 PLUMBING SYMBOLS AND ABBREVIATIONS RLW I MBW RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel r �un��V l�rcNalM�� DATE: 06�04�20 P-001 a