NOTE: ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION ON THE DRAWINGS. ALL SYMBOLS NOT NECESSARILY USED ON THIS PROJECT.
GENERAL SYMBOLS: PIPING DESIGNATIONS: PLUMBING ABBREVIATIONS:
ih POINTOF CONNECTION �� NEW PIPING AFF ABOVE FlNISHED ROOR
Y
}, s EXISTINGPIPINGTOREMAIN AFG ABOVEFINISHEDGRADE
�..` POINT OF REMOVAL AHU AIR HANDLING UNIT
Y F i EXISTING PIPING TO BE REMOVED
AD ACCESSDOOR
Oi PLAN NOTE �� PIPE SLOPES IN DIRECTION OF ARROW AV ACID VENT
AW ACID WASTE
�---. DOMESTICCOLDWATER
�1 DEMOLITION NOTE BDD BACK DRAFT DAMPER
�--� DOMESTICHOTWATER BHP BRAKEHORSEPOWER
1� REVISION �----. DOMESTICHOTWATERRETURN BLDG BUILDWG
BOD BOTTOM OF DUCT
�----140�F—f DOMESTICHOTWATER140`F BOP BOTTOMOFPIPE
A
�ETAIL BUBBLE BOS BOTTOM OF STEEL
MWi �----140�F—f DOMESTICHOTWATER140`FRETURN
BTU BRITISHTHERMALUNIT
S W� WASTEPIPING CO QEANOUT
1
M501 SECTION BUBBLE S ST� STORM PIPING CS CUP SINK
CSS CLINICSERVICESINK
�--------� SANITARVVENT
CW DOMESTIC COLD WATER
S D� INDIRECTDRAIN D CONDENSATEIDRAIN
DB DRY BULB
S AW � ACID WASTE
DCV DOUBLECHECKVALVE
Y------- AV ----- i AQD VENT DIA DIAMETER
VALVES & FITTINGS: s DE� DEIONIZEDWATER DN DOWN
DWH DOMESTICWATERHEATER
�j GATE VALVE S DI� DISTILLED WATER FD FLOOR DRAIN
�j BALL VALVE S RODI—. REVERSE OSMOSIS DEIONRED WATER ESEW EMERGENCV SHOWER AND FACE/EYE WASH
EW EMERGENGV EVHFACE WASH
'� —I/�—s BUTTERFLVVALVE S LS—. LAWNSPRWKLER
EL ELEVATION
S G� 6AS ES EMERGENCVSHOWER
s—��s CHECK VALVE
EXIST EXISTING
S F05—. FUEL OIL SUPPLY
�j GLOBEVAWE FCO FLOORCLEANOUT
S FOR—. FUEL OIL RETURN FLA FULL LOAD AMPS
�� VALVE IN VERTICAL PIPE HB HOSE BIBB
� S FOV—. FUELOILVENT
CONTROLVALVE HKSP HOUSEKEEPING
S VAC—. VACUUM HW DOMESTIC HOT WATER
� REDUCED PRESSURE BACK FLOW PREVENTER HWR DOMESTIC HOT WATER RETURN
�A� COMPRESSEDAIR
HWCP HOT WATER RECIRCULATION PUMP
� . INDICATED FLOW DIRECTION
IE INVERTELEVATION
� PIPETURN90° JS JANITORSINK
LAV LAVATORV
SPECIALTY PIPING MB MOPBAs�N
� LINE BREAK
�MV� MEDICALVACUUM NC NORMALLVCLOSED
�e PIPE ELBOW UP (RISER) NO NORMALLV OPEN
�SV� SURGICAL VACUUM PIV POST INDICATING VALVE
�� PIPEELBOWDOWN PSIA POUNDSPERSQUAREINCHABSOLUTE
�LV� LABVACUUM
�� PIPE TEE DOWN PSIG POUN�S PER SQl1ARE INCH GAl1GE
�N2� NITROGEN
RO REVERSE OSMOSIS
�� CAP OR PLUG
�N20� NITROUSOXIDE RPBP REDUCEDPRESSUREBACKFLOWPREVENTER
� REDUCER, CONCENTRIC
SAN SANITARV
�CO2� CARBON DIOXIDE
`� —��, REDUCER, ECCENTRIC SH SHOWER
�AG� ARGON SI SEDIMENTINTERCEPTOR
���� FLANGES SK SINK
�MA� MEDICALAIR
SS STAINLESSSTEEL
��I�s UNION �LA� LABAIR ST STORM WATER
`� —o-� METER TD TRENCH DRAIN
V SANITARY VENT
�p FO FLOOR DRAIN VTR VENTTHROUGH ROOF
FIRE PROTECTION PIPING SYMBOLS W WASTE
� GAUGE WC WATERCLOSET
S F FIRE PROTECTION
4 WH WALLHV�RANT
❑T
0
�
THERMOMETER
STEAM TRAP
PRESSURE SENSOR
INLINE PUMP
PA PRE-ACTION
F�P FIRE DRV PIPE
nun
�Y�
�
TS
�I:i�
�I:i�
CONNECTION (FREE STANDING)
CONNECTION (WALL MOUNTED)
0
GENERAL NOTES:
1. VERIFY EXISTING CONOITIONS IN THE FIELD PRIOR TO BUILDING AND BEFORE
BEGINNING WORK.
2 REVIEWTHEWORKOFOTHERTRAOES,COOR�INATEAND-PLANWORKWITHTHE
OTHER TRADES AND OWNER. ADJUST AS A RESULT OF COORDINATION.
3. STORE EQUIPMENT ANO COMPONENTS IN A CLEAN, DRV LOCATION UNTIL REA�V
FOR INSTALLATION. PROTECT FROM WEATHER, OIRT, WATER, AND CONSTRUCTION
DEBRIS, ETG AT ALL TIMES. ANV DAMAGED EpUIPMENT OR COMPONENTS SHALL
BE RESTORED AS NEW OR REPLACED.
4. ALL MATERIALS REMOVED AND NOT RELOCATED BECOME THE PROPERTV OF THE
CONTRACTOR. REMOVE MATERIALS FROM THE PROJECT SITE UNLE55 NOTEO
OTHERWISE.
5. PATCH WALLS, FLOORS, CEILINGS, COW MNS, ROOF PENETRATIONS, ETC. WHERE
ITEMS ARE REMOVEO TO MATCH AOJACENT SURFACES.
6. DRAWINGS SHOW THE INTENDEO ARRANGEMENT AND ROUTING OF ALL PIPING,
EQUIPMENT, AND APPURTENANCES. THEV SHALL BE FOLLOWED AS CLOSELV AS
ACTUAL BUILOING CONSTRUCTION AND WORK OF OTHER TRAOES WILL PERMIT.
]. CLEAN ALL EQl11PMENT TO PRESENT A"LIKE NEW" CONOITION AT PROJECT
COMPLETION.
8. OFFSET PIPING AROUND ELECTRICAL PANELS TO PROVIDE CLFARANCES AS
REpUIRED BV THE NATIONAL ELECTRICAL CODE.
FLOW SWITCH
ZONE CONTROL VALVE WITH TAMPER SWITCH
FIRE PROTECTION GENERAL NOTES:
1. SVSTEM DESIGN IS PER NFPA 13, STANDARD FOR THE INSTALLATION OF
SPRINKLER SVSTEMS.
2 ALL WORK AND MATERIALS SHALL CONFORM TO NFPA 13, AND STATE RULES AND
REGULATIONS.
3. ALL MATERIALS, WHERE APPLICABLE SHALL BE U.L LISTED AND FACTORY MUTUAL
APPROVED FOR THE USE IN AUTOMATIC SPRINKLER SVSTEMS.
4. PROVIDEAMINIMUMOF]2HOURNOTICETOTHEOWNERPRIORTOSPRINKLER
PIPE TESTING OR LINE PRESSURIZATION.
5. FIRE PROTECTION CONTRACTOR SHALL PREPARE ALL DRAWINGS AND
APPLICATIONS REpUIRED TO OBTAIN APPROVAL OF THE SVSTEM BV OWNERS
INSURANCE UNDERWRITER, STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION. ALL�RAWINGSTOBESUBMITTEDDURINGCONSTRUCTION.
6. FIREPROTECTIONCONTRACTORSHALLSUBMITDRAWINGSWITHALLSPRINKLER
HEAD LOCATIONS. ALL SPRINKLER HEADS TO BE LAID OUT NEATLV WITHIN THE
CEILWG SVSTEMS AND BE COORDINATED WITH ALL DISCIPLINES, BULKHEADS,
CEILWGS AND STRUCTURE.
0
1"F
�vE R Es�.
cueni
EVERESTREINSURANCEIINSURANCE
11I11 NORTH MERI�IAN STREET
CARMEL IN 46032
5 PENN PLAZA, STH FLOOR. NEW YORK, NV 10001
� �
Appl ied
Engineering Services
5975CastleCreekParkwayNDrive,5uite3W • Indianapolis,Indiana46250
TeP, 317.8ID.4141 • FaX:317.810.414� • www.applied-e-s.mm
13Y19C1J
SIGNATIIRE
5T
SiATE OF
4�24�2020
r�0
PLUMBING SYMBOLS AND
ABBREVIATIONS